WIKA · Pressure measurement · Family DPT
Differential pressure transmitter
Differential pressure transmitter with high accuracy and multiple output signals, suitable for industrial applications including process, chemical, and petrochemical industries.
Range
-16…16 bar
Output
4-20 mA · 4-20 mA HART
Accuracy
See specifications by range
Protection
IP65
CENACEintrinsic safetyflameproof enclosure
Price
On request
Depends on configuration
Description
The model DPT-20, with its 4 ... 20 mA, 4 ... 20 mA HART ® , FOUNDATION™ Fieldbus or PROFIBUS ® PA output signals, combined with the intrinsic safety or flameproof enclosure ignition protection type, is ideally suited for application in appropriate systems. The development of the transmitter in accordance with the demands of SIL (Safety Integrated Level) IEC 61508 also makes it applicable for plants with special safety requirements.
Special features
- High measurement accuracy
- Freely scalable measuring ranges
- Developed in accordance with the SIL 2 requirements
- Seven different case variants
- Configuration via DTM (Device Type Manager) in accordance with the FDT (Field Device Tool) concept (e.g. PACTware™)
Identification
| Model | DPT-20 |
| Product family | DPT |
| Subcategory | Differential pressure transmitter |
Measuring range
| Pressure ranges | -0.01…0.01 bar · -0.03…0.03 bar · -0.1…0.1 bar · -0.5…0.5 bar · -3…3 bar · -16…16 bar · -0.15…0.15 psi · -1.5…1.5 psi · -7.5…7.5 psi · -45…45 psi · -240…240 psi |
Accuracy
| Accuracy class | See specifications by range |
| Accuracy standard | IEC 62828, IEC 61298 |
| Safety integrity level (SIL) | SIL 2 (IEC 61508) |
Process conditions
| Process connection | ½ NPT¼ NPTG 1/2M20x1.5 |
| Process temperature | −40…+85 °C |
Electrical characteristics
| Output signal | 4-20 mA · 4-20 mA HART · FOUNDATION™ Fieldbus · PROFIBUS® PA |
| Power supply | 10...30 V DC |
| Electrical connection | M20 x 1.5 |
Materials
| Case material | plastic, aluminium, stainless steel (316L) |
| Wetted parts material | 316L, Hastelloy |
| Sealing material | FKM, EPDM, FPM, NBR |
Operating environment
| Ambient temperature | −40…+85 °C |
| IP rating | IP65 |
| Weight | 1.5 kg |
Certifications and approvals
| Certifications | CENACE |
| Explosion protection | intrinsic safetyflameproof enclosure |
Additional details
| Datasheet languages | EN, DE, ES, FR |
Tables from datasheet
Accuracy specifications
| Measuring deviation determined using the limit point method IEC 62828/IEC 61298 1) | ||
|---|---|---|
| Differential pressure | Measuring ranges 10 and 30 mbar [0.15 and 0.45 psi] | ■ TD ≤ 5:1 ±0.1 %of span ■ TD > 5:1 ±0.02%xTD |
| Measuring range 100 and 500 mbar [1.5 and 7.5 psi] | ■ ToTD 10:1 ±0.065 %of span ■ TD > 10:1 ±0.035 %+0.01%xTD | |
| Measuring range 3 bar [45 psi] | ■ ToTD 10:1 ±0.065 %of span ■ >TD 10:1 ±0.015 %+0.005%xTD | |
| Measuring range 16 bar [240 psi] | ■ ToTD 10:1 ±0.065 %of span ■ >TD 10:1 ±0.035 %+0.01%xTD | |
| Static pressure | < ±0.1 %(scaling with static pressure is not possible) | |
| Adjustability, differential pressure | ||
| Pressure value of zero point | -120 ...+120 %of the nominal measuring range (with -100 ...+100 mbar [-1.5 ... +1.5 psi] measuring range, 100 mbar [1.5 psi] is the nominal measuring range) | |
| Pressure value of span | Zero point + (-240 …+240 %) | |
| Adjustability, level | ||
| Percentage value | -10…+100% | |
| Pressure value | -120…+120% | |
| Adjustability, flow | ||
| Pressure value of zero point | -120…+120% | |
| Pressure value of span | -120…+120% | |
| Influence of mounting position | < 0.35 mbar [0.003 psi] per 10° inclination from the vertical | |
| Influence of the medium and ambient temperature | ||
| -10 ...+60 °C [14 ... 140 °F] | Measuring range 10 mbar [0.15 psi] | < ±0.15%+0.2%xTD |
| Measuring range 30 mbar [ 0.45 psi] | < ±0.15%+0.1%xTD | |
| Measuring range 100 mbar [1.5 psi] | < ±0.15 %+0.15%xTD | |
| Measuring range 500 mbar [7.5 psi] | < ±0.15 %+0.05%xTD | |
| Measuring range 3 bar [45 psi] | < ±0.15 %+0.05%xTD | |
| Measuring range 16 bar [240 psi] | < ±0.15 %+0.15%xTD | |
| -40 …-10 °C [-40 ...+14 °F] / 60 …85°C[140 ... 185 °F] | Measuring range 10 mbar [0.15 psi] | < ±0.4%+0.3%xTD |
| Measuring range 30 mbar [ 0.45 psi] | < ±0.2 %+0.15%xTD | |
| Measuring range 100 mbar [1.5 psi] | < ±0.15%+0.2%xTD | |
| Measuring range 500 mbar [7.5 psi] | < ±0.2 %+0.06%xTD | |
| Measuring range 3 bar [45 psi] | < ±0.2 %+0.06%xTD | |
| Measuring range 16 bar [240 psi] | < ±0.15%+0.2%xTD | |
| Long-term stability | ||
| Differential pressure | ■ < 0.065 %xTD(1 year) ■ < 0.1 %xTD(5 years) ■ < 0.15 %xTD(10 years) | |
| Static pressure | ■ < ±0.065 %(1 year) ■ < ±0.1 %(5 years) ■ < ±0.15 %(10 years) | |
| Thermal change of zero point and output span depending on the static pressure | ||
| Measuring ranges 10 and 30 mbar [0.15 and 0.45 psi] | To nominal pressure | 40 bar [600 psi] |
| Influence on the zero point | < ±0.1%xTD | |
| Influence on the span | < ±0.1% | |
| Measuring ranges 100 and 500 mbar [1.5 and 7.5 psi] | To nominal pressure | 160 bar [2,400 psi] |
| Influence on the zero point | < ±0.1%xTD | |
| Influence on the span | < ±0.1% |
Accuracy specifications
| Measuring ranges 3 and 16 bar [45 and 240 psi] | To nominal pressure | 400 bar [5,800 psi] |
|---|---|---|
| Influence on the zero point | < ±0.25%xTD | |
| Influence on the span | < ±0.25% | |
| Thermal change | Change of the current output with 4 ...20 mAsignals: 0.05 %per 10 K based on 20 °C [68 (maximum 0.15 %at set measuring span) in the ambient temperature range -40 …+80 °C [-40 …+176 °F] | |
| Reference conditions per IEC 61298-1 | ||
| Temperature | +18 ...+30 °C [64 ... 86 °F] | |
| Air pressure | 860 ... 1,060 mbar [86 ... 106 kPa, 12.5 ... 15.4 psig] | |
| Air humidity | 45 ... 75 %r.h. | |
| Characteristic curve determination | Terminal method per IEC 61298-2 | |
| Curve characteristics | Linear | |
| Reference mounting position | Vertical, i.e. vertical process assembly (connections are on the side) |
Measuring range
| Measuring range 1) | -10 mbar ... +10 mbar [-0.15 ... +0.15 psi] | -30 mbar ... +30 mbar [-0.45 ... +0.45 psi] | -100 mbar ... +100 mbar [-1.5 ...+1.5 psi] | -500 mbar ... +500 mbar [-7.5 ...+7.5 psi] | -3 bar ...+3 bar [-45 ...+45 psi] | -16 bar ... +16 bar [-240 ... +240 psi] |
|---|---|---|---|---|---|---|
| Maximum operating pressure | 40 bar [600 psi] | 160 bar [2,400 psi] (option: 400 bar [5,800 psi]) | ||||
| Lowest static pressure 2) | 1 mbar abs.[0.015 psi], with application for oxygen the static pressure should not be lower than 10 mbar abs. [0.15 psi] | |||||
| Turndown ratio | Maximum permissible turndown is unlimited (max. 20:1 is recommended) | |||||
| Overload, on one side | 40 bar [600 psi] | 160 bar [2,400 psi] (option: 400 bar [5,800 psi]) | ||||
| Overload, on both sides | 60 bar [900 psi] | 240 bar [6,300 psi] (option: 630 bar [9,100 psi]) |
| Connection | Mounting | Material | Equipment |
|---|---|---|---|
| ¼-18 NPT IEC 61518 | 7/16-20 UNF | AISI 316L (1.4404) | 2 vent valves 1) |
| ¼-18 NPT IEC 61518 | 7/16-20 UNF | Hastelloy C276 (2.4819) | 2 vent valves 1) |
View all (14)
| Connection | Mounting | Material | Equipment |
|---|---|---|---|
| ¼-18 NPT IEC 61518 | 7/16-20 UNF | AISI 316L (1.4404) | 2 vent valves, 4 plug screws 1) |
| ¼-18 NPT IEC 61518 | 7/16-20 UNF | Hastelloy C276 (2.4819) | 2 vent valves, 4 plug screws 1) |
Output signal
| Signal type | 4 …20mA, 2-wire, (option: 4 ... 20 mA, 2-wire with superimposed communication signal HART ® , FOUNDATION™ Fieldbus, PROFIBUS ® PA) | ||
|---|---|---|---|
| Permissible max. load | R A = (U B - U Bmin )/0.023 A | ||
| Dead time | ■ 160 ms (10 and 30 mbar [0.15 and 0.45 psi]) ■ 130 ms (remaining measuring ranges) | ||
| Time constant (90 %) | ■ 115 ms (10 and 30 mbar [0.15 and 0.45 psi]) ■ 95 ms (100 mbar [1.5 psi]) ■ 75 ms (500 mbar [7.5 psi]) ■ 60 ms (3 bar [45 psi] and 16 bar [240 psi]) | ||
| Damping (63 %of the input variable) | 0 …999 s, adjustable | ||
| Deviation through interference | Strong, high-frequency fields can influence the current output with 4 …20mA, within the scope of EN 61326-1, by up to ±80 µA. | ||
| Voltage supply | |||
| Supply voltage | 4 ...20mA | Inactive backlighting | DC 11 ...35V |
| Active backlighting | DC 16 ...35V | ||
| 4 ... 20 mAwith a superimposed HART ® communication signal | Inactive backlighting | DC 11 ...35V | |
| Active backlighting | DC 16 ...35V | ||
| PROFIBUS ® PA (max. 32 BUS instruments) | Inactive backlighting | DC 9 ...32V | |
| Active backlighting | DC 13.5…32V | ||
| FOUNDATION™ Fieldbus (max. 32 BUS instruments) | Inactive backlighting | DC 9 ...32V | |
| Active backlighting | DC 13.5…32V | ||
| Electrical safety | Overvoltage category III, protection class II |
Electrical connection
| Spring-loaded terminals | Wire cross-section | ■ Wire or strand: 0.2 ... 2.5 mm² (AWG 24 ... 14) ■ Strand with end splice: 0.2 ... 1.5 mm² (AWG 24 ... 16) |
|---|---|---|
| Cable glands M20 x 1.5 | ||
| Sealed with blind plug | ||
| Plastic, PA | Sealing | NBR |
| Cable diameter | ■ 5 ... 9 mm[0.2 ... 0.35 in] ■ 6 ... 12 mm[0.24 ... 0.47 in] ■ 10 ... 14 mm[0.39 ... 0.55 in] | |
| Brass, nickel-plated | Sealing | NBR |
| Cable diameter | ■ 5 ... 9 mm[0.2 ... 0.35 in] ■ 6 ... 12 mm[0.24 ... 0.47 in] | |
| Stainless steel | Sealing | NBR |
| Cable diameter | 7 ... 12 mm[0.28 x 0.47 in] | |
| Cable glands ½ NPT | ||
| Sealed with blind plug | ||
| Plastic, PA | Cable diameter | ■ 5 ... 9 mm[0.2 x 0.35 in] ■ 6 ... 12 mm[0.24 ... 0.47 in] ■ 10 ... 14 mm[0.39 ... 0.55 in] |
| Brass, nickel-plated | Cable diameter | ■ 5 ... 9 mm[0.2 ... 0.35 in] ■ 6 ... 12 mm[0.24 ... 0.47 in] |
| Electrical safety | Reverse polarity protection |
Material
| Material (wetted) | |
|---|---|
| Process connection | 316L (1.4404) (option: Hastelloy C276 (2.4819)) |
| Diaphragm | 316L (1.4435) (option: Hastelloy C276 (2.4819) |
| Sealing | FKM (option:EPDM, copper) |
| Case material | |
| Single chamber case, plastic | PBT, polyester |
| Single chamber case, aluminium | Die-casting AlSi10Mg, powder-coated on PE basis |
| Single chamber case, cast stainless steel | Stainless steel 316L |
| Single chamber case, electropolished stainless steel, deep-drawn | Stainless steel 316L |
| Double chamber case, plastic | PBT, polyester |
| Double chamber case, aluminium | Die-casting AlSi10Mg, powder-coated on PE basis |
| Double chamber case, cast stainless steel | Stainless steel 316L |
| Pressure transmission medium 1) | Silicone oil (halocarbon oil for oxygen applications) |
Display and operating unit (option)
| Backlighting | Yes | ||
|---|---|---|---|
| Background | Grey, black digits | ||
| Upgradable | Yes (for order numbers, see 'Accessories') | ||
| Menu languages | German English French Spanish | Polish Italian Dutch Japanese | Turkish |
| Display size | 5-digit measured value display, adjustable (option: bar graph display) Max. 5 digits, size 7 x 13 mm[0.28 x 0.51 in] | ||
| Ingress protection (IP code) per IEC 60529 | ■ IP20 (loose) ■ IP40 (built-in without cover) | ||
| Material | Case from ABS, window from polyester film |
Operating conditions
| Permissible temperature ranges | ||
|---|---|---|
| Ambient | ■ -40 …+80 °C [-40 ...+176 °F] (without display) ■ -20 …+70 °C [-4 ...+158 °F] (with display) | |
| Storage and transport | -60 …+80 °C [-40 ...+176 °F] | |
| Restrictions to medium temperature due to the sealing material | ||
| FKM | -20 …+85 °C [-4 ...+185 °F] | |
| EPDM, copper | -40 …+85 °C [-40 ...+185 °F] | |
| FKM, oil- and grease-free | -10 …+85 °C [14 ... 185 °F] | |
| For oxygen applications (max. static pressure: 160 bar [2,400 psi]) | Copper | -20 …+60 °C [-4 ...+140 °F] |
| EPDM | -10 …+60 °C [-4 …+140 °F] | |
| FKM | -10 …+60 °C [14 ... 140 °F] | |
| Temperature limits | With differential pressure lines longer than 100 mm:-40 …+120 ° [-40 ... 248 °F] | |
| Vibration resistance per IEC 60068-2-6 1) | 4 g (5 …200 Hz), vibration under resonance | |
| Shock resistance per IEC 60068-2-27 | 50 g for 2.3 ms, mechanical shock | |
| Ingress protection (IP code) per IEC 60529 | IP66/67 (standard case) | |
| Weight | Approx. 4.2 …4.5 kg [9.26 ... 9.92 lbs] depending on the process connection and case variant |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity | European Union | |
| EMCdirective, interference emission (group 1, class B) and immunity per EN 61326-1:2013 (industrial application), EN 61326-2-3:2013 1) | ||
| Pressure equipment directive | ||
| RoHS directive |
| Logo | Description |
|---|---|
| SIL IEC 61508 / IEC 6151 | SIL 2 (option) Functional safety ■ 1-channel operation up to SIL 2 |
| - | NAMUR recommendations NE 021 - Electrical compatibility of equipment NE 043 - Signal level for failure information NE 053 - Compatibility of field instruments |
Certificates
| Certificates | ■ 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, material proof, indication accuracy) ■ 3.1 inspection certificate per EN 10204 (e.g. material proof for wetted metal parts, indication accuracy, calibration certificate) |
|---|---|
| Calibration | DAkkS calibration certificate (traceable and accredited in accordance with ISO/IEC 17025) |
| Description | Order number | |
|---|---|---|
| Display module, model DIH52-F 5-digit display, 20-segment bar graph, without separate power supply, with additional HART ® functionality. Automatic adjustment of measuring range and span. Secondary-master functionality: Setting the measuring range and unit of the connected transmitter possible using HART ® standard commands. Optional: Explosion protection per ATEX | On request | |
| HART ® modem for USB interface, specifically designed for use with notebooks (model 010031) | 11025166 | |
| HART ® modem for RS-232 interface (model 010001) | 7957522 | |
| HART ® modem for Bluetooth interface Ex ia IIC (model 010041) | 11364254 | |
| PowerXpress HART ® modem, with optional power supply (model 010031P) | 14133234 | |
| 3-valve manifold, form A, ½NPTfemale (IEC 61518-A) Stainless steel, PN 420, form A, NACE-compliant, 3.1 material certificate | 13382498 | |
| 3-valve manifold, form A, 1/4 NPT female (IEC 61518-A) Stainless steel, PN 420, form A, NACE-compliant, 3.1 material certificate | 13382510 | |
| 5-valve manifold, form A, ½NPTfemale (IEC 61518-A) Stainless steel, PN 420, form A, NACE-compliant, 3.1 material certificate | 13382552 | |
| 5-valve manifold, form A, 1/4 NPT female (IEC 61518-A) Stainless steel, PN 420, form A, NACE-compliant, 3.1 material certificate | 13382561 | |
| Oval flange, 1/4 NPT, stainless steel (2 pieces) Stainless steel, PN 420, form A, NACE-compliant, 3.1 material certificate | 13382609 | |
| Oval flange, ½NPT, stainless steel (2 pieces) Stainless steel, PN 420, form A, NACE-compliant, 3.1 material certificate | 13382595 | |
| Set of sealing plugs, 1/4 NPT, 316L (2 pieces) For the vents at the differential pressure sensor Included in delivery with lateral venting, except for process connection from Hastelloy | 14035620 | |
| Set of vent valves, 1/4 NPT, 316L (2 pieces) For the vents at the differential pressure sensor Included in delivery, except for process connection from Hastelloy | 14368975 | |
| Instrument mounting bracket for wall or pipe mounting with mounting bracket and screws, stainless steel | 11553945 | |
| Overvoltage protection For transmitters, 4 ... 20 mA, M20 x 1.5, series connection | 14002489 | |
| For transmitters, PROFIBUS ® PA, M20 x 1.5, series connection | 14013659 | |
| Model DI-PT-R display and operating module, case cover aluminium with window | 12298884 | |
| Model DI-PT-R display and operating module, case cover electropolished cast stainless steel with window | 13315269 | |
| Model DI-PT-R display and operating module, case cover plastic with window | 13315277 | |
| Model DI-PT-R display and operating module, case cover cast stainless steel with window for single chamber case | 12298906 | |
| Model DI-PT-R display and operating module, case cover cast stainless steel with window for double chamber case | 14045598 | |
| Model DI-PT-E external display and operating module, aluminium case | 12354954 | |
| Model DI-PT-E external display and operating module, cast stainless steel case | 12355101 | |
| Model DI-PT-E external display and operating module, plastic case | 14134247 |
Industry
Oil & Gas
Petrochemical industry
Industry
Chemistry / Pharma
Process engineering · Chemical industry
Industry
Machinery
Machine building and plant construction
Industry
Food industry
Food and beverage industry
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →All variants · Article table
1 standard articles of family DPT
If you know the code — pick directly. If not — use the configurator in mode “01”.
Stock:
SKUConfigurationPriceStockAction