AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
CPA8001 1
CPA8001
On order
WIKA · Calibration technology · Family CPA

Pressure controller

Air data test set for automated calibration of altimeters, airspeed indicators, and air data computers with high accuracy and touchscreen interface.
Range
-34…3725 mbar
Output
mA · V
Protection
IP20
CERoHS
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Special features

  • Ps/Qc or Ps/Pt removable transducer that can be changed via the front
  • Control stability 0.001 % of span
  • Accuracy up to 0.009 % IS-50 (IntelliScale)
  • Uncertainty: ±2.5 ft, ±0.06 knots
  • RVSM-compliant and automated zero point adjustment
Identification
ModelCPA8001
Product familyCPA
SubcategoryPressure controller air data test set
Measuring range
Pressure ranges-34…3386 mbar · 0…950 mbar abs. · 0…1253 mbar abs. · 0…1355 mbar abs. · 0…3725 mbar abs. · -34…100 mbar · 552…1172 mbar abs. · 100…1000 mtorr abs. · 0…950 mbar · 0…1253 mbar · 0…1355 mbar · 0…3725 mbar · 0…37 inHg abs. at 0℃ · 0…110 inHg abs. at 0℃ · -1…3 inHg D at 0℃ · -1…100 inHg D at 0℃ · 552…1172 hPa abs. · 8…17 psi abs.
Temperature ranges+15…+45 °C · +0…+70 °C
Accuracy
Uncertainty0.009 % IS-50
Process conditions
Mediumclean dry air, nitrogen
Calibration typesignal
Electrical characteristics
Output signalmA · V · Ps · Pt · Qc · Ps/Qc · Pt/Pt
Operating environment
Ambient temperature+15…+35 °C
IP ratingIP20
Weight23.6 kg
Certifications and approvals
Certifications
CERoHS
TraceabilityA2LA · DAkkS
Additional details
PortableNo
Datasheet languagesEN
Tables from datasheet
As barometric reference
Measuring range■ 552 ... 1.172 mbar abs. ■ 8 ... 17 psi abs. ■ 552 ... 1.172 hPa abs.
Accuracy 1)0.01 %of reading
FunctionThe barometric reference can be used to switch pressure types 2) , absolute <=> gauge. With gauge pressure sensors, the measuring range of the sensors must begin with -1 bar [-15 psi] in order to carry out an absolute pressure emulation.
Uncertainty specifications / repeatability
Ps pressure range0.009 %IS-50 0 …32inHg abs.0.009 %IS-50 0 …34inHg abs.
AltitudeSea level ±2.5 ft 29,000 ft ±3.4 ft 41,000 ft ±5.7 ftSea level ±2.5 ft 29,000 ft ±3.6 ft 41,000 ft ±6 ft
Pressure32 inHg ±0.0027 inHg 15 inHg ±0.0014 inHg 5 inHg ±0.0014 inHg34 inHg ±0.003 inHg 15 inHg ±0.0015 inHg 5 inHg ±0.0015 inHg
Qc pressure range0.01%FS -1 …32inHg0.01%FS -1 …80inHg
Airspeed250 kn ±0.12 kn 500 kn ±0.05 kn 661 kn ±0.03 kn250 kn ±0.31 kn 500 kn ±0.13 kn 661 kn ±0.08 kn 1,000 kn ±0.03 kn
Control parameter
Control stability of pressure units0.002 %of span
Control stability of aviation units→ See table &#x27;Control stability of aviation units&#x27;
Control speed10 s to stable flag for a 10 %pressure change into 150 ml [cc] volume. Larger volumes can lengthen this time. Controlling to pressures less than 30 mbar abs. [0.5 psi abs.] will lengthen this time.
Control range0 ...100%FS
Rate control0 ... 6,000 ft/min
Stability of the rate control±0.8 %of the set rate ±10 ft/min
Minimum control pressure0.0017 bar [0.025 psi] over exhaust pressure or 0.05%FS → Whichever is greater
Test volume50 ... 1,000 ccm [3 ... 60 in³]
Further details on: control stability of aviation units
AltitudeAirspeed
in ftStability (± ft)KnotsStability (± Knots)
Stability-1,8700.5604.684
00.59101.042
5,0000.69200.540
10,0000.80300.363
20,0001.11400.273
30,0001.58500.218
40,0002.39600.182
50,0003.88700.156
60,0006.28800.136
65,0007.99900.121
--1000.108
--2000.052
--3000.033
--4000.023
--5000.017
--6000.013
--7100.009
View all (13)
Pressure connections
Connections■ 6 ports with 7/16"-20 F SAE female ■ 2 ports with barb fitting
Filter elementsAll pressure ports have a 20-micron filters except the barometer and Qc reference.
Pressure adapters■ 7/16"-20 SAE male to 6 mmtube fitting ■ 7/16"-20 SAE male to ¼" tube fitting ■ 7/16"-20 SAE male to ¼NPT, female thread ■ 7/16"-20 SAE male to ⅛NPT, female thread ■ 7/16"-20 SAE male to ⅛BSP, female thread ■ AN4 fitting ■ AN6 fitting
Barometer adaptersBarb fitting
Qc referenceBarb fitting
Overpressure protectionSafety relief valve scaled to 120 %of full scale of each sensor.
Pressure connections
Permissible pressure
Supply port (Ps, Pt/Qc)Approx.110%FS
Measure/Control port (Ps, Pt/Qc)Max.105%FS
Communication
Interface■ Ethernet ■ IEEE-488 ■ USB ■ RS-232 (null modem cable not required)
Baud rate■ 9600 ■ 19200 ■ 38400 ■ 57600 ■ 115200
Command sets■ Mensor ■ WIKA SCPI ■ Others on request
Response time< 100 ms
Voltage supply and performance data
Operating voltage■ AC 100 ... 120 V, 50/60 Hz ■ AC 200 ... 240 V, 50/60 Hz
Power consumptionMax.140VA
Supply voltage fluctuation±10 %(AC 90 ...132V / 180 ... 264 V)
Overvoltage resistanceCategory II
Fuse2.5 A, 250V;SLO-BLO5x20mm
Power cord■ For Europa ■ For USA/Canada ■ For UK ■ For India ■ For China
Operating conditions
Place of useIndoor Not for wet locations
Altitude per ISA (International Standard Atmosphere)■ Up to 19,800 m[65,000 ft] for software ■ Up to 2,000 m[6,562 ft] for instruments
Operating temperature15 ... 35 °C [59 ... 95 °F]
Compensated temperature range15 ... 45 °C [59 ... 113 °F]
Storage temperature range0 ... 70 °C [32 ... 158 °F]
Relative humidity, condensation35 ... 85 %relative humidity (non-condensing)
Permissible pressure media10 %over the range of the channel&#x27;s transducer ■ Clean dry air (class 3 instrument air per ISO 8753) ■ Nitrogen (ISO 8573-1:2010 class 5.5.4 or better)
Mounting position of transducerHorizontal or slightly tilted
Permissible pollution degreeDegree 2
EMC (HF field)EN 61326-1 emission (group 1, class A) and immunity (industrial application)
LogoDescriptionRegion
EU declaration of conformityEuropean Union
Certificates
Calibration 1)
Barometric reference■ Without ■ A2LA calibration certificate (traceable and accredited in accordance with ISO/IEC 17025) ■ DAkkS calibration certificate for barometric reference (traceable and accredited in accordance with ISO/IEC 17025)
Reference pressure sensor model CPR8001■ A2LA calibration certificate (traceable and accredited in accordance with ISO/IEC 17025) ■ DAkkS calibration certificate - for two measuring ranges (traceable and accredited in accordance with ISO/IEC 17025)
Recommended calibration interval1 year (dependent on conditions of use)
Description 1)Order code CPX-A-A8
-19" rack-mount case With side pieces, EU With side pieces,NAM-R- -U-
Barometric reference Measuring range: 552 ... 1,172 mbar abs. Accuracy to 0.01 %of reading-1-
Measuring range: 552 ... 1,172 hPa abs. Accuracy to 0.01 %of reading-2-
Measuring range: 8 ... 17 psi abs. Accuracy to 0.01 %of reading-3-
Calibration adapter For reference pressure sensor, voltage supply and software-4-
Calibration adapter For barometric reference, voltage supply and software-5-
Calibration adapter For vacuum sensor, voltage supply and software-F-
-Dual differential pressure relief valve-G-
-Spare vacuum sensor-H-
RS-232 interface cable-9-
Adapter set 6 mmSwagelok ® male thread (4 adapters) Max. 137 bar [2,000 psi]-M-
Material: brass
Max. 137 bar [2,000 psi] Material: brass Adapter set ⅛BSPG, female thread (4 adapters)-B-
Max. 137 bar [2,000 psi] Material: brass
Adapter set ¼NPT, female thread (4 adapters) Max. 137 bar [2,000 psi] Material: brass-N-
Description 1)Order code
CPX-A-A8
Adapter ⅛NPT, Max. 137 Material:set female thread (4 adapters) bar [2,000 psi] brass-S-
-Adapter set Consisting of: 2 x AN4 fittings 4 x AN6 fittings Max. 137 bar [2,000 psi] Material: brass-C-
-Adapter set Consisting of 4 x AN4 fittings Max. 137 bar [2,000 psi] Material: brass-D-
-Adapter set Consisting of 4 x AN6 fittings Max. 137 bar [2,000 psi] Material: brass-E-
Ordering information for your enquiry:
1. Order code: CPX-A-A8 2. Option:⇓ [ ]