Analogue cable amplifier
Description
The B1940 analogue cable amplifier is used to adapt the output signal of strain gauge force transducers to indicators or to a downstream controller.
Through the compact form of its case, it can be fastened almost anywhere with a simple screw clamp. The case corresponds to IP67 ingress protection and is thus suitable for use in harsh environments.
All strain gauge force transducers that can be operated with a DC voltage can be connected. With the combination of the cable amplifier with a force transducer, this force unit can be adjusted in line with customer wishes.
Analogue cable amplifier, model B1940
The supply voltage of DC 18 ... 30 V ensures a direct connection to a PLC. This usually features a 24-volt supply voltage. The analogue output enables the direct signal processing in the PLC.
Special features
- High accuracy
- Input signal: strain gauge measuring bridge; Output signal: 0/4 ... 20 mA or DC 0 ... 10 V
- Cable length between amplifier and read-out unit: up to 100 m are possible
- Compact design
- Ingress protection IP67
| Model | B1940 |
| Subcategory | Signal amplifier |
| Accuracy class | < 0.01 % FS |
| Process temperature | +10…+50 °C |
| Output signal | 0/4 ... 20 mA or DC 0 ... 10 V |
| Ambient temperature | +0…+60 °C |
| IP rating | IP67 |
| Weight | 0.1 kg |
| Certifications | EN 61326-1:2013EN 61236-2-1:2013CISPR 11:2009 + A1:2010CEEN61236-2:1:2013 |
| Cable length | 3 m |
| Datasheet languages | EN, DE |
| Model B1940 | Version 0/4 ... 20 mA | Version DC 0 ... 10 V |
|---|---|---|
| Input signal | 4 x 350 Ωsensor, 4- or 6-wire | |
| Sensitivity | 0.35 ... 3 mV/V | |
| Linearity | < 0.01%FS | |
| Output signal | 0/4 ... 20 mA, 3-wire | DC ±5V / ±10 V, 3-wire |
| Residual ripple | < 10 mVat 400Ω | < 10mV |
| Max. load | Load < 400Ω | - |
| Output resistance | - | <1Ω |
| Sensor supply | Short-circuit-proof to DC 10V (max. 20 mA) | |
| Temperature effect on supply voltage | < 25 ppm / K | |
| Temperature effect on zero signalTK 0 | ±0.1 μV / °C | |
| Temperature effect on characteristic value TK c | ±5 ppm / °C | |
| Rated temperature range | 10 ... 50 °C | |
| Service temperature range | 0 ... 60 ° C | |
| Storage temperature range | -30 ...+80 °C | |
| Insulation resistance | DC 100V,1GΩ | |
| Supply voltage | DC 18 ...30V | |
| Residual ripple | ≤ 100mVRMS | |
| Current supply | < 70mA | |
| Limit frequency | 1 kHz - 3 dB others on request | |
| Ingress protection | IP67 | |
| Electromagnetic compatibility | EN 61326-1:2013 EN 61236-2-1:2013 CISPR 11:2009 + A1:2010 | |
| Dimensions (Ø x L) | 28 x 118 mm(incl. threaded connection) | |
| Cable length | ||
| Sensor side | 1 m(max.3 m) | |
| Output side | 3 m(max.100 m) | 3 m(max.10 m) |
| Weight | approx. 100 g |