Differential pressure sensor
Description
The model A2G-500 is used to measure differential pressure, gauge pressure and vacuum in air and also in non-aggressive and non-flammable gases in ventilation and air-conditioning systems.
The piezoresistive measuring element is temperature-compensated and particularly stable over the long term. It records even the smallest pressure differences and thus ensures high reliability and the highest measurement accuracy. The measured values are available as analogue voltage and current signals, digitally via the RS-485 interface using Modbus ® RTU or via LoRaWAN ® . Integration into any control system or directly into cloud solutions is therefore easily possible.
With relay outputs, the instrument becomes a cost-saving differential pressure switch or 2-point controller.
Differential pressure sensor, model A2G-500
The A2G-500 has freely adjustable measuring ranges. The instrument can be set using the WIKA app and NFC and, depending on the version, using buttons and LEDs or buttons and a display. Efficient project documentation is possible using instrument parameter file readout via NFC and smartphone. The indication of up to four measured values and two relay states can be read from all viewing angles thanks to 2" TFT colour display with traffic light function and individualised measurement parameter lettering.
The construction of the A2G-500 is robust and weather-proof (IP65). The case can be opened without tools thanks to the snap-on cover. The graphics of the cover sheet insert can be customised. The instruments can thus be optimally integrated into any system design.
Special features
- IIoT-ready and future-proof thanks to analogue and digital signal transmission (Modbus ® ) as well as wireless (LoRaWAN ® )
- Time-saving instrument configuration and display of current measured values on the smartphone via NFC or WIKA app
- No cabling effort for retrofit projects thanks to battery operation and LoRaWAN ®
- Decentralised data node − up to four input signals − reduces cabling effort and installation costs
- Reduction of installation costs due to simple wall or DIN rail mounting in a control cabinet
Build a A2G-500 for your task
The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.
- kind of measurementdp-sensor
- UnitPa
- operating Range—
- measuring range—
- signal output0...10 V, 3-wire
- Digital displaywithout
- zero point settingwithout
- analog out 2without
- Relayohne
- input signalwithout
- Special cable connectionwithout
- Accessorieswithout
- Certificateswithout
- Approvalswithout
- Additional ordering informationWithout
Finish your configuration
Select every option to submit the request.
| Model | A2G-500 |
| Product family | A2G |
| Subcategory | Differential pressure sensor |
| Pressure ranges | 0…250 Pa · 0…1000 Pa · 0…1500 Pa · 0…2000 Pa · 0…2500 Pa · 0…5000 Pa · 0…7000 Pa · -250…250 Pa · -2500…2500 Pa · -7000…7000 Pa · -12000…12000 Pa · -25…25 Pa · -50…50 Pa · -100…100 Pa · -150…150 Pa · 0…25 Pa · 0…50 Pa · 0…100 Pa · -500…500 Pa · -1000…1000 Pa · 0…500 Pa · 0…3000 Pa · 0…4000 Pa · 0…6000 Pa · 0…7500 Pa · 0…8000 Pa · 0…9000 Pa · 0…10000 Pa · 0…12000 Pa |
| Accuracy class | 0.50 % FS |
| Accuracy standard | EN 837 |
| Process connection | 2 x connecting nozzle Ø 5 mm2 x connecting nozzle Ø 7 mmFor hoses with inner diameter 4 ... 6 mm2x connecting nozzle Ø5 mm / Ø7 mm |
| Process temperature | −40…+120 °C |
| Output signal | Modbus® RTU · LoRaWAN® · Relay · 0 ... 10 V · 0 ... 5 V · 2 ... 10 V · 4 ... 20 mA · Modbus RTU · LoRaWAN |
| Power supply | 24 V ±10 % AC/DC |
| Electrical connection | Spring-clip terminals |
| Switching function | NO, NC, Force open, force closed |
| Switching contacts | 2 |
| Case material | PC GF20, PC, ABS |
| Wetted parts material | PC, ABS, PC GF20 |
| Ambient temperature | −40…+60 °C |
| IP rating | IP65 |
| Weight | 0.32 kg |
| Certifications | RoHSWEEEEN 837EN 10204 |
| Datasheet languages | EN |
| Specifications | 1 x analogue output 2-wire or 3-wire (single range) 1) | 1 x analogue out- put 3-wire (multi range) | Modbus ® RTU (multi range) | 1 x wireless (battery power) |
|---|---|---|---|---|
| Display | | O | O | |
| Additional analogue output | | O | O | |
| Signal inputs | | O | O | |
| Relay | | O | O | |
| Automatic zero point setting | | O | O | |
| Wireless signal (LoRaWAN ® ) | | O | O | ü |
| NFC | ||||
| Configure | ü | ü | ü | ü |
| Read | ü | ü | ü | ü |
| Case dimensions | → See dimensions on page 6 |
|---|---|
| Process connection 1) | |
| 2 x connecting nozzle | Ø 5 mm[0.19 in] /Ø 7 mm[0.27 in] |
| For hoses | With inner diameter 4 ... 6 mm[0.15 ... 0.23 in] |
| Case 1) | PC GF20 |
| Cover with insert sheet 1) | PC, transparent; ABS, RAL 9010 |
| Mounting plate 1) | PC, RAL 7035 |
| Weight (dependig on version) | 260 ... 320 g [0,57 ... 0,70 lb] |
| ±250 Pa | ±1 inWC |
|---|---|
| -25 …+25 | -0.1 ... +0.1 |
| -50 …+50 | -0.2 ... +0.2 |
| -100 …+100 | -0.4 ... +0.4 |
| -150 …+150 | -0.6 ... +0.6 |
| 0…25 | 0 ... 0.1 |
| 0…50 | 0 ... 0.2 |
| 0 …100 | 0 ... 0.4 |
| 0 …250 | 0 ... 1 |
| ±2,500 Pa | ±10 inWC |
|---|---|
| -500 …+500 | -2 ...+2 |
| -1,000 …+1,000 | -4 ...+4 |
| 0 …250 | 0 ... 1 |
| 0 …500 | 0 ... 2 |
| 0 …1,000 | 0 ... 4 |
| 0 …1,500 | 0 ... 6 |
| 0 …2,000 | 0 ... 8 |
| 0 …2,500 | 0 ... 10 |
View all (13)
| ±7,000 Pa | ±28 inWC |
|---|---|
| 0 …1,000 | 0 ... 4 |
| 0 …1,500 | 0 ... 6 |
| 0 …2,000 | 0 ... 8 |
| 0 …2,500 | 0 ... 10 |
| 0 …3,000 | 0 ... 12 |
| 0 …4,000 | 0 ... 16 |
| 0 …5,000 | 0 ... 20 |
| 0 …7,000 | 0 ... 28 |
| ±12,000 Pa | ±48 inWC |
|---|---|
| 0 …5,000 | 0 ... 20 |
| 0 …6,000 | 0 ... 24 |
| 0 …7,000 | 0 ... 28 |
| 0 …7,500 | 0 ... 30 |
| 0 …8,000 | 0 ... 32 |
| 0 …9,000 | 0 ... 36 |
| 0 …10,000 | 0 ... 40 |
| 0 …12,000 | 0 ... 48 |
| Pressure type | Differential pressure |
|---|---|
| Unit | ■ Pa ■ kPa ■ mbar ■ mmWC ■ inWC |
| Operating pressure | ■ ±250 ... ±2.500 Pa [±1 ...±10 inWC]: 10 kPa [40 inWC] ■ ±7.000 ... ±12.000 Pa [±28 ...±48 inWC]: 100 kPa [400 inWC] |
| Measuring element | Piezo measuring cell |
| Digital display | |
| Display resolution | 240 x 320 dpi |
| Type of display | 2"TFT colour display |
| Dashboard function | Indication of up to four measured values and two relay states possible; automatic size scaling depending on the number of measured values displayed. Indicated values can be given any alphanumeric designation. |
| Colour configuration | Range of setting possibilities; colours definable via RGB code. |
| Alarm function | Definition of two limit values possible; on reaching these limit values, a colour change can be defined for each (e.g.'Warning' and 'Alarm') |
| Accuracy 1) | 0.50%FS 2) | |||
|---|---|---|---|---|
| Operating range | ±250 Pa [ ±1 inWC] | ± 2,500 Pa [ ± 10 inWC] | ± 7,000 Pa [ ± 28 inWC] | ± 12,000 Pa [ ± 48 inWC] |
| Temperature range | ||||
| Compensated 3) TC 4) offset (% FS/K) | 0.015% | 0.01% | 0.008% | 0.005% |
| Uncompensated 5) TC 4) offset (% FS/K) | 0.025% | 0.02% | 0.02% | 0.01% |
| Compensated 3) TC 4) span (% FS/K) | 0.02% | 0.02% | 0.01% | 0.01% |
| Uncompensated 5) TC 4) span (% FS/K) | 0.03% | 0.02% | 0.02% | 0.02% |
| Zero point setting | ■ Manually via push button on the PCB ■ 'myWIKA wireless device' app ■ Automatic 6) |
| Output signals | ■ 0 ... 10 V, 0 ...5V or 2 ... 10 V, 3-wire ■ 4 ... 20 mA, 2- or 3-wire ■ Relay ■ Modbus ® ■ LoRaWAN ® |
|---|---|
| Number of analogue outputs | ■ 1 x ■ 2 x |
| Load | |
| Current output | Max.500Ω |
| Voltage output | Typ. 1 kΩ, min.700Ω |
| On-site interface | NFC (near field communication) |
|---|---|
| Standard | ISO/IEC 15693 |
| Modulation | 13.56 MHz |
| Protocol | Modbus ® via serial interface |
|---|---|
| Transfer mode | RTU |
| Interface | RS-485 |
| Max. voltage | ■ ± 10V without terminating resistor ■ ± 6V with terminating resistor |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity | European Union | |
| EMCdirective | ||
| RED - Radio Equipment Directive | ||
| RoHS directive | ||
| WEEE directive |
| Model | Description | Order number |
|---|---|---|
| Measuring hoses | ||
| PVC hose, inner diameter 4 mm[0.16 in], roll at 25 m[82.02 ft] | 40217841 | |
| PVC hose, inner diameter 6 mm[0.24 in], roll at 25 m[82.02 ft] | 40217850 | |
| Silicone hose, inner diameter 4 mm[0.16 in], roll at 25 m[82.02 ft] | 40217906 | |
| Silicone hose, inner diameter 6 mm[0.24 in], roll at 25 m[82.02 ft] | 40217914 | |
| Duct connector for measuring hoses Ø4…6mm[0.16 …0.24 in] | 40217507 | |
| Multiple sealing inserts (for M20 cable gland) Sealing insert with 2 bores at Ø4mm[0.16 in];PU 10 x | 40444284 | |
| Sealing insert with 2 bores at Ø6mm[0.24 in];PU 10 x | 40444285 | |
| Sealing insert with 4 bores at Ø5mm[0.20 in];PU 10 x | 40444286 | |
| Sealing plug for sealing insert with 4 bores, each with Ø5mm[0.20 in]; PU 50 x | 40454873 | |
| Battery AA 3.6 V, 2.6 Ah (only with battery version);PU 2 x | 40443947 | |
| - | LoRaWAN ® gateway, preconfigured for WIKA network server Gateway for indoor use | On request |
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →57 standard articles of family A2G
If you know the code — pick directly. If not — use the configurator in mode “01”.