SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

Планирование запасных частей

Планирование запасных частей - ULTRAMAT/OXYMAT 6

Дальнейшая информация

Description 7MB2023 7MB2024 2 years (qty) 5 years (qty) Order No.
Analyzer section
Analyzer section, ULTRAMAT channel
- O-ring for hose cell x x 1 2 C75121-Z101-C1
- O-ring for chopper x x 1 2 C75121-Z101-C2
- O-ring for reflector x x 1 2 C75121-Z101-C3
- O-ring for cover (window, front side) x x 2 2 C75121-Z101-C4
- O-ring for cooler element x x 1 1 C75121-Z101-C5
- O-ring for cover (window, rear side) x x 2 2 C79121-Z100-A24
- IR source x x 1 1 C79451-A3462-B12
- Cover (cell length 20 mm … 180 mm) x x 2 2 C79451-A3462-B151
- Cover (cell length 0.2 mm … 6 mm) x x 2 2 C79451-A3462-B152
- O-rings, set x x 1 C79451-A3462-D501
Analyzer section, OXYMAT channel
- O-ring x x 1 2 C74121-Z100-A6
- O-ring (measuring head) x x 2 4 C79121-Z100-A32
- Spacer x x 1 C79451-A3277-B22
- Sample cell, V4A 1.4571, non-flow-type compensation branch x x 1 C79451-A3277-B535
- Sample cell, tantalum, non-flow-type compensation branch x x 1 C79451-A3277-B536
- Sample cell, V4A 1.4571, flow-type compensation branch x x 1 C79451-A3277-B537
- Sample cell, tantalum, flow-type compensation branch x x 1 C79451-A3277-B538
- Measuring head, non-flow-type compensation branch x x 1 1 C79451-A3460-B525
- Measuring head, flow-type compensation branch x x 1 1 C79451-A3460-B526
Sample gas path
O-ring (stubs) x x 2 4 C71121-Z100-A159
Pressure switch x x 1 2 C79302-Z1210-A2
Flowmeter (only version with pump) x x 1 1 C79402-Z560-T1
Sample gas path, ULTRAMAT channel
- O-ring (chopper) x x 1 2 C75121-Z100-C3
- Stubs x x 1 C79451-A3478-C9
Sample gas path, OXYMAT channel
- Restriction, SS type No. 1.4571, pipe gas path x 2 2 C79451-A3480-C10
- Restriction, titanium, pipe gas path x x 2 2 C79451-A3480-C37
- Reference gas path, 3000 hPa x x 1 1 C79451-A3480-D518
- Capillary tube, 100 hPa, connection set x x 1 1 C79451-A3480-D519
- Restriction, SS type No. 1.4571, pipe gas path x x 1 1 C79451-A3250-C5
Electronics
Front panel with keyboard x x 1 1 C79165-A3042-B506
Adapter board, LCD/ keyboard x x 1 1 C79451-A3474-B605
LC display x x 1 1 W75025-B5001-B1
Connector filter x x 1 W75041-E5602-K2
Fuse-link, T 0.63/250 V x x 2 3 W75054-L1010-T630
Fuse-link, 1 A, 110/220 V x x 2 3 W75054-L1011-T100
Fuse-link, 2.5 A, 250 V x x 2 3 W75054-L1011-T250
Electronics, ULTRAMAT channel
- Base plate, without firmware x x 1 C79451-A3474-B620
- Fuse-link, 1.6 A, 250 V x x 2 3 W75054-L1011-T160
Electronics, OXYMAT channel
- Base plate, without firmware x x 1 C79451-A3474-B601
- Temperature fuse x 1 W75054-T1001-A150

If the unit was delivered with specially cleaned gas path for high oxygen content (so-called „Cleaned for O2 service“), please absolutely specify it for a spare part order. This is the only way to guarantee that the gas path furthermore corresponds to the special requirements for this variant.

Заказные данные

Заказной № Описание Вес (кг) Доставка Мин. зак. (шт)
C75121-Z100-C3 O-RING 0.005 6 - 8 недель (C) 10
C79451-A3277-B535 ИЗМЕРИТЕЛЬНАЯ ЯЧЕЙКА V4A FOR OXYMAT 5 OXYMAT 6 / 61 0.1 3 - 5 недель (A) 1
C79451-A3277-B536 ИЗМЕРИТЕЛЬНАЯ ЯЧЕЙКА, TANTALUM, FOR OXYMAT 5/6 0.23 3 - 5 недель (A) 1
C79451-A3277-B537 ИЗМЕРИТЕЛЬНАЯ ЯЧЕЙКА 1.4571, FOR OXYMAT 5/6 0.12 3 - 5 недель (A) 1
C79451-A3277-B538 ИЗМЕРИТЕЛЬНАЯ ЯЧЕЙКА, TANTALUM, FOR OXYMAT 6 0.215 по запросу (X) 1
C79451-A3460-B525 MEASURING HEAD FOR OXYMAT 6 AND OXYMAT 61 0.33 6 - 8 недель (C) 1
C79451-A3460-B526 MEASURING HAED FOR OXYMAT 6 AND OXYMAT 61 0.33 6 - 8 недель (C) 1
C79451-A3520-C5 RESTRICTOR (STAINLESS STEEL 1.4571) 0.099 6 - 8 недель (C) 1
W79054-L1011-T250 FUSE, T 2,5A / 250V 0.005 4 - 6 недель (B) 10

Заказные данные [PDF]

.

Для просмотра информации в формате PDF необходимо установить Adobe Acrobat Reader. Adobe Acrobat Reader