Message without a reaction · SINAMICS G130, G150, S120, S150

N35800TM: Group signal

What it means

N35800 (TM: Group signal) is a group message raised by a Terminal Module (TM) — depending on the drive object, for example a TM120, TM15, TM150, TM17, TM31 or TM41. The Terminal Module has detected at least one fault, and this message gathers that condition without naming the individual fault itself. The same condition can also be issued as fault F35800; which form the drive outputs is decided by its configuration.

Why it appears

  • The Terminal Module has detected at least one fault. The code is only a group signal and does not identify which fault it is.

What to check

  1. The manual's remedy for this code is a single step: Evaluates other actual messages. So open the list of currently active faults and alarms on the operator panel or in the commissioning tool and identify the message that is really present.
  2. Follow the cause and remedy given on the page for that other message — this group signal only points to it.

Acknowledging and restarting

The message form of this code needs no acknowledgement and no special reset. If the drive is configured to raise the same condition as fault F35800 instead, the drive carries out the reaction configured for that fault and the fault must be acknowledged IMMEDIATELY before the drive will start again.

What differs between the drive families

Straight from the manuals' own fields — N35800 is not described identically everywhere.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150Infeed: OFF2 (NONE, OFF1) Servo: OFF2 (IASC/DCBRK, NONE, OFF1, OFF3, STOP2) Vector: OFF2 (IASC/DCBRK, NONE, OFF1, OFF3, STOP2) Hla: OFF2 (NONE, OFF1, OFF3, STOP2)NONEGeneral drive fault (19)NoneSINAMICS S120, S150 List Manual · p. 3232
G130, G150Vector: OFF2 (IASC/DCBRK, NONE, OFF1, OFF3, STOP2) Infeed: OFF2 (NONE, OFF1)NONEGeneral drive fault (19)NoneSINAMICS G130, G150 List Manual · p. 1895

The drives this code lives on

N35800 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does N35800 mean on a SINAMICS drive?

It is a group signal from a Terminal Module: the module has detected at least one fault. The message itself does not say which fault — the actual fault or alarm is among the other currently active messages.

How do I acknowledge or reset N35800?

As a message it requires no acknowledgement at all. If your configuration outputs the same condition as fault F35800, that fault must be acknowledged IMMEDIATELY before the drive restarts.

What is the difference between N35800 and F35800?

They are the same condition from the Terminal Module. The drive configuration decides whether it appears as a message without a reaction (N35800) or as a fault with a reaction and IMMEDIATELY acknowledgement (F35800).

Which Terminal Modules can report N35800?

Any Terminal Module present in the configuration, for example TM120, TM15, TM150, TM17, TM31 or TM41, depending on the drive object.

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the N35xxx group · SINAMICS manuals · Siemens manuals