Message without a reaction · SINAMICS G130, G150, S120, S150

N32800Encoder 2: Group signal

What it means

N32800 is the group signal of Encoder 2. It names no individual fault: the drive raises it because the motor encoder has detected at least one fault, i.e. because another message of this encoder is currently active. The manuals for SINAMICS G130/G150 and for S120/S150 describe the message identically. Depending on the drive configuration, the same condition can also be issued as a fault.

Why it appears

  • The motor encoder has detected at least one fault; N32800 only announces that at least one individual message of Encoder 2 is present.

What to check

  1. Evaluate the other messages that are active at the same time: the individual Encoder 2 messages show which actual fault the group signal is reporting.

Acknowledging and restarting

The message form needs no acknowledgement. When the drive raises the condition as a fault, it is acknowledged immediately.

What differs between the drive families

Straight from the manuals' own fields — N32800 is not described identically everywhere.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150Servo: OFF1 (IASC/DCBRK, NONE, OFF2, OFF3) Vector: OFF1 (IASC/DCBRK, NONE, OFF2, OFF3) Hla: OFF1 (NONE, OFF2, OFF3)NONEActual position/speed value incorrect or not available (11)NoneSINAMICS S120, S150 List Manual · p. 3114
G130, G150OFF1 (IASC/DCBRK, NONE, OFF2, OFF3)NONEActual position/speed value incorrect or not available (11)NoneSINAMICS G130, G150 List Manual · p. 1791

The drives this code lives on

N32800 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does N32800 mean on a SINAMICS drive?

It is the group signal of Encoder 2: the motor encoder has detected at least one fault, and the message announces that an individual Encoder 2 message is active.

Why does N32800 name no cause?

The message is a summary signal. Its remedy is to evaluate the other messages that are active at the same time, and those carry the actual fault information.

Can N32800 also appear as a fault?

Yes. Depending on the drive configuration, the same condition is issued as a fault as well.

How is N32800 cleared?

The message form needs no acknowledgement. In its fault form it is acknowledged immediately.