What it means
F40895 is issued on the G130, G150, S120 and S150 when a DRIVE-CLiQ communications error occurs on the link from the CX32 controller extension involved to the Control Unit. The fault is raised at the DRIVE-CLiQ Hub Module (Hub). The fault cause recorded for this code is 11 (= 0B hex): a synchronization error during alternating cyclic data transfer. The manuals of all four families describe the code identically, so the same meaning and the same remedy apply on every one of them.
Why it appears
- A DRIVE-CLiQ communications error has occurred from the controller extension involved (the CX32) to the Control Unit.
- The fault cause reported in this case is 11 (= 0B hex): a synchronization error during alternating cyclic data transfer.
What to check
- Carry out a POWER ON (switch-off/switch-on) of the drive.
- If the fault recurs, the remedy for this code cross-references p9915 (DRIVE-CLiQ data transfer error shutdown threshold master).
Reading the message value
- The drive stores the component number and the fault cause in the message value, which can be read at r0949 (fault value) or r2124 (alarm value).
- Coding: 0000yyxx hex, where yy = component number and xx = error cause.
- For this code the error cause reads 11 — synchronization error during alternating cyclic data transfer.
Parameters the manual names
- r0949 (fault value): shows the coded message value 0000yyxx hex for this fault, i.e. the component number and the error cause.
- r2124 (alarm value): the second location where the same coded message value is stored.
- p9915 (DRIVE-CLiQ data transfer error shutdown threshold master): the threshold the manual names in the remedy cross-reference for this DRIVE-CLiQ data transfer error.
Acknowledging and restarting
The fault must be acknowledged immediately; while it is active the drive coasts down (OFF2) and does not restart until it has been cleared. The remedy the manual gives is a POWER ON: switch the drive off and then on again. No further reset or repair steps are described for this code.
The same on every family
Every manual that describes F40895 gives it the same reaction, acknowledgement and message class.
| Drive family | Reaction | Acknowledge | Message class | Component | Manual |
|---|---|---|---|---|---|
| G130, G150 | OFF2 | IMMEDIATELY | Internal (DRIVE-CLiQ) communication error (12) | DRIVE-CLiQ Hub Module (Hub) | SINAMICS G130, G150 List Manual · p. 1931 |
| S120, S150 | OFF2 | IMMEDIATELY | Internal (DRIVE-CLiQ) communication error (12) | DRIVE-CLiQ Hub Module (Hub) | SINAMICS S120, S150 List Manual · p. 3287 |
The drives this code lives on
F40895 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.
Questions technicians ask
What does SINAMICS fault F40895 mean?
It reports a DRIVE-CLiQ communications error from the CX32 controller extension involved to the Control Unit. The fault cause is 11 (= 0B hex): a synchronization error during alternating cyclic data transfer.
How do I clear fault F40895?
Acknowledge the fault immediately and carry out a POWER ON (switch-off/switch-on). This POWER ON is the only remedy the manual describes.
Where can I read the message value of F40895?
At r0949 (fault value) or r2124 (alarm value). It is coded 0000yyxx hex, where yy is the component number and xx the error cause.
Which component reports F40895?
The DRIVE-CLiQ Hub Module (Hub), on G130, G150, S120 and S150 drives.
Codes next to this one
Source
Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.