Alarm · SINAMICS S120, S150

A35807TM: Sequence control time monitoring

What it means

A35807 is reported by a Terminal Module (TM) — for example a TM15, TM17 or TM41 — on a SINAMICS S120 or S150. The drive monitors the time in which the sequence control on the Terminal Module runs, and the module has signalled an error: a timeout in this sequence control. Depending on how the drive is configured, the same condition can also be output as a fault or as a message that triggers no reaction.

Why it appears

  • A timeout has occurred in the sequence control on the Terminal Module; the module reports this as an error.

What to check

The manual describes no intermediate checks — its only remedy is:

  1. Replace the Terminal Module.

Acknowledging and restarting

As an alarm the message requires no acknowledgement and the drive does not perform an automatic stop; the message clears once the faulty Terminal Module has been replaced. If the drive is configured to output the same condition as a fault, the fault is acknowledged IMMEDIATELY (POWER ON). In the variant that triggers no reaction, no acknowledgement is required either.

The same on every family

Every manual that describes A35807 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONENONEHardware/software error (1)Terminal Module (TM)SINAMICS S120, S150 List Manual · p. 3234

The drives this code lives on

A35807 is described for S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does alarm A35807 mean on a SINAMICS S120 or S150?

It is reported by a Terminal Module (for example TM15, TM17 or TM41): a timeout has occurred in the sequence control on the module. The drive monitors this sequence control time and raises the message when the module signals the error.

How do I clear alarm A35807?

The manual gives a single remedy: replace the Terminal Module. No parameters or other checks are described for this message.

Does A35807 stop the drive, and must it be acknowledged?

No. As an alarm it needs no acknowledgement. If your configuration outputs the same condition as a fault instead, it is acknowledged IMMEDIATELY (POWER ON).

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the A35xxx group · SINAMICS manuals · Siemens manuals