SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

Технічний документ JCI — GLAS Installation Instructions

Вид документаТехнічний документ
ВиробникJCI
Код документаGLAS
Сторінок46
Мова документаанглійська
Розмір файлу1.9 МБ

Текст документа

GLAS
Installation Instructions
Support
If at any point you need assistance, we’re here to help.
Visit www.glas.johnsoncontrols.com/support for how-to videos and frequently asked
questions.

Can’t find what you’re looking for? Give us a call at 1-833-297-4527(GLAS) and our
technical team can walk you through it.

Before you start, download the GLAS app for easy installation.

Google Play and the Google Play Logo are marks and/or registered marks of Google LLC. Apple, the Apple Logo and App Store are
marks and/or registered marks of Apple Inc.

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                                                       1
Included in the box
                                                      2x 1-1/2" Pan-head Phillips screws
            GLAS smart thermostat
                                                      2x 1" Pan-head Phillips screws
            Air seal
                                                      2x 1" Flat-head Phillips screws
            Wall plate                                4x Drywall anchors

            C-wire adapter                            Wiring stickers

            Quick start guide

Tools required
            Screwdriver                 Drill with 1/4" bit                                    Level
2                                   GLAS smart thermostat installation instructions - © 2018 Johnson Controls
Compatibility
GLAS is compatible with most 24 VAC heating and cooling systems.
Use the compatibility checker to ensure your system will work with GLAS by going to
www.glas.johnsoncontrols.com/compatibilitychecker.

 Heating                      One or two stages
 Cooling                      One or two stages
 Heat Pump                    One or two stages with one or two stages auxiliary heat
 Fan                          Single-speed fan
 Auxiliary                    Humidifier, dehumidifier, or ventilator (including HRV or ERV)

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                      3
Terminal descriptions
Note: If you have only one R wire, connect to RC.
Note: If you are removing an existing thermostat, remove any jumper wires between R and
      RH or RC and RH. You will not need these for GLAS.

Y1    First stage of cooling or first stage heat pump
Y2    Second stage of cooling or second stage heat pump
W1 First stage of conventional heating or first stage auxiliary heat for heat pump systems
W2 Second stage of conventional heating or second stage of auxiliary heat for heat
   pump systems
G     Fan

4                                           GLAS smart thermostat installation instructions - © 2018 Johnson Controls
Terminal descriptions

 O/B        Heat pump reversing valve (supports both O type and B type)
 AUX        Auxiliary - humidifier, dehumidifier, or ventilator
 Rc         24 VAC Cool
 Rh         24 VAC Heat
 C          24 VAC Common

GLAS smart thermostat installation instructions - © 2018 Johnson Controls   5
    IMPORTANT: If your thermostat is built into the wall and connected to
    thick wires with wire nuts, or if it is labeled 110, 120, or 240 volts, you have
    a high voltage system that is not compatible with the GLAS Thermostat.
    Do not connect your thermostat to these high voltage wires. GLAS is only
    compatible with 24 VAC systems.

6                                 GLAS smart thermostat installation instructions - © 2018 Johnson Controls
To begin installation, turn off system power
1. Turn off all power to your heating or cooling system at the HVAC unit’s
   electrical switch or the breaker box for the building to avoid electrocution or shock.

Note: If you are not replacing an existing thermostat, skip to Step 6.

2. If you want to check your system power, adjust the temperature on your current thermostat
   and wait a few minutes to ensure that your heating or cooling does not power on.

                       WARNING: Risk of Electric Shock.
                       Turn off the power supply before making electrical connections. Contact
                       with components carrying hazardous voltage can cause electric shock and
                       may result in severe personal injury or death. If you have any doubts about
                       properly installing the device, please contact a professional installer.

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                            7
Check old wiring
3. If you are replacing an existing thermostat, remove the front plate of your old
   thermostat and take a picture of the current wire colors and connections.
   This picture will come in handy when connecting your new thermostat.

8                                           GLAS smart thermostat installation instructions - © 2018 Johnson Controls
Removing your old thermostat
4. Before removing the wires from your thermostat terminals, use the included wiring
   stickers to label your wires.

5. Disconnect your old thermostat and remove the backplate.

Note: While disconnecting your old thermostat, use drywall-safe tape to secure the
      wires and keep them from falling back into the wall.

GLAS smart thermostat installation instructions - © 2018 Johnson Controls              9
Installing your GLAS
6. Remove the front plate by pulling the
   center of the silver cover toward you from
   the bottom.

Note: Do not pull on the black sensor bar
     while removing the front plate as this
     could damage the device.

7. Use a level and the included wall plate to
   mark the wall where you plan to hang the
   thermostat. Then drill the holes using
   the 1/4” drill bit and push in the drywall
   anchors.

10                                          GLAS smart thermostat installation instructions - © 2018 Johnson Controls
Installing your GLAS
8. Remove the liner over the air seal
   adhesive and align the seal with the drill
   holes on the back side of the GLAS
   device. Lightly press to secure.

Note: If you are using the optional back
  plate, secure between the wall and the
  GLAS before screwing in the device.

9. Pull all of the wires through both the air
   seal and terminal opening in the GLAS
   smart thermostat. Press firmly on the
   wires to push them through the air seal.

GLAS smart thermostat installation instructions - © 2018 Johnson Controls   11
Attaching your GLAS
10. Loosely attach your GLAS to the anchors
    installed in the wall using the included
    screws.

11. Use a level to straighten the
    thermostat and tighten the screws until
    snug. Do not overtighten.

12                                            GLAS smart thermostat installation instructions - © 2018 Johnson Controls
Connect optional C-wire adapter
Note: If you have a C-wire at your thermostat, skip
to Step 16. If you do not have a C-wire to power
your thermostat, use the included C-wire adapter to
provide power.

12. Remove the cover of your furnace or air handling
    unit to access the control board and take a picture
    of the current wiring for reference.

13. In your HVAC equipment, disconnect the
    Y, W, R, or G thermostat wires that are currently
    connected to the control board. Do not
    disconnect any of the other wires.

GLAS smart thermostat installation instructions - © 2018 Johnson Controls   13
Connect the C-wire adapter
14. Remove the adapter cover and connect the
    now disconnected Y, W, R, or G wires to
    the corresponding terminal on the C-wire
    adapter.

15. Connect the five labeled wires on the                       Y (1)

    adapter to the corresponding terminals on                   W(2)

    the control board.                                         R (3)
                                                               G (4)

Note: See pages 20-22 for wiring configurations.

Note: Connections for the G, Y, and R wires
      are required to support the adapter.

14                                           GLAS smart thermostat installation instructions - © 2018 Johnson Controls
Wiring your GLAS
16. Use the picture you took of your old wiring and the wiring stickers as a reference and
    connect the wires to the corresponding terminals on your new GLAS.
    See pages 23-43 for wiring examples.

Note: Depending on the features of your furnace or air handler, you may not have a
      connection for every terminal.

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                15
Attach the front plate
17. Before replacing the cover, remove the
    red tab to the right of the wiring
    terminals by pulling straight out. This
    will enable the backup battery in your
    device.

18. Make sure any excess wire is flush
    against the device and press the front
    plate until you hear a click.

16                                            GLAS smart thermostat installation instructions - © 2018 Johnson Controls
Powering on your heating and cooling system
19. Return to your heating and cooling system switch or breaker box to turn the power back on.

20. Once power has been switched on, wait for the welcome screen with the GLAS logo and
    select Tap to continue. After continuing, you will be prompted to accept the End User
    License Agreement and then the Privacy Notice and Terms of Service to access
    Internet-enabled features.

21. You will be prompted to confirm your wiring. If any wires were incorrectly detected, tap to
    correct them.

22. Follow the instructions on the device screen to complete the setup for your heating and
    cooling system.

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                     17
                  WIRING
                 DIAGRAMS
NOTE: Wire colors are for reference only. Not every installation will have wires of the same
color. If you are unsure of how to properly install the unit, please contact a licensed
electrician or a professional HVAC installer before attempting the installation.

18                                          GLAS smart thermostat installation instructions - © 2018 Johnson Controls
GLAS smart thermostat installation instructions - © 2018 Johnson Controls   19
     Heating and Cooling without C-wire (Optional AUX)
               GLAS
                                                                                  Air Handler Control Board

         C                     AUX

         RC                     G

         W1                     Y1
                                                            C-wire adapter
          W2                   Y2                                                Y       W   O   R       G       C AUX
          RH                   O

                                                                                     Y   W           R       G    C

                                            Y1      Y (1)

                  WIRES IN WALL             W1      W(2)
                 TO GLAS DEVICE             RC      R (3)
                                             G      G (4)

                                        To GLAS

               *Any additional wires should
               bypass the C-wire adapter    AUX

20                                                GLAS smart thermostat installation instructions - © 2018 Johnson Controls
                   Cooling Only without a C-wire (Optional AUX)
                                     GLAS                                                        Air Handler Control Board

                           C                         AUX

                          RC                          G

                          W1                          Y1
                                                                                C-wire adapter
                                                                                                 Y       W       O   R       G       C AUX
                           W2                        Y2

                            RH                       O

                                                                                                     Y       W           R       G    C

                                                                  Y1    Y (1)
                                                                        W(2)
                                       WIRES IN WALL
                                      TO GLAS DEVICE             RC     R (3)
                                                                  G     G (4)

                                                             To GLAS

                                    *Any additional wires should
                                    bypass the C-wire adapter    AUX

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                                                                    21
Heat Pump with Auxiliary Heat without C-wire (Optional AUX)
               GLAS                                                                   Air Handler Control Board

        C                        AUX

        RC                         G

        W1                        Y1
                                                               C-wire adapter
                                                                                    Y       W   O   R       G       C AUX
         W2                      Y2

         RH                      O

                                                                                        Y   W           R       G    C

                                               Y1      Y (1)
                                               W1      W(2)
                    WIRES IN WALL
                   TO GLAS DEVICE              RC      R (3)
                                                G      G (4)

                                             To GLAS

              *Any additional wires should     O
              bypass the C-wire adapter      AUX
22                                                     GLAS smart thermostat installation instructions - © 2018 Johnson Controls
                                                       Traditional AC and Heat
                                                                                  HVAC System Control Board
                                                                                             Heat            Cool
                                                                                  C    RC   Stage 1   Fan   Stage 1

                                                 red
                                                       Furnace
                                                                                  C    RC    W1       G       Y1
                                              we
                                         e Povice n
                                     rnac De Ru
                                   Fu AUX R
                                    C

                                                                 C          AUX

           Outdoor AC Unit                                       RC          G

                                                                 W1          Y1

                                                                  W2        Y2

                                                                  RH        O

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                                             23
                                                    Heat Pump
                                                                                         HVAC System Control Board

                                                                                                           Compressor Reversing
                                                                                        C     RC     Fan    Stage 1     Valve

                                    Furnace
                              red
                            wee
                       e Povic n
                   rnac De Ru
                 Fu AUX R                                                               C     RC      G        Y1        O
                  C

                                              C                       AUX

                                              RC                        G
     Heat Pump
                                              W1                       Y1

                                               W2                     Y2

                                               RH                     O

24                                                     GLAS smart thermostat installation instructions - © 2018 Johnson Controls
            One Stage Heat Pump with One Stage Auxiliary Heat

                                                                                      HVAC System Control Board
                                                                                                              Compressor
                                                                                             Aux Heat          Command Reversing
                                                                                  C     RC    Stage 1   Fan     Stage 1  Valve

                                                   Furnace
                                             red
                                           wee
                                      e Povic n
                                                                                  C     RC     W1       G         Y1       O
                                  rnac De Ru
                                Fu AUX R
                                 C

                                                             C              AUX

                                                             RC              G
           Heat Pump
                                                             W1              Y1

                                                              W2            Y2

                                                              RH            O

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                                                          25
                                         Traditional Heat
                                                                                          HVAC System
                                                                                          Control Board
                                                                                                            Heat
                                                                                          C        RC      Stage 1

                             red

                                                                                          C        RC        W1
                          we
                     e Povice n
                 rnac De Ru
               Fu AUX R
                C

                                                                                    NOTE: When there is only
                                   C                        AUX                     one transformer, the RC terminal
                                                                                    is used.
     Furnace
                                   RC                        G                      NOTE: Forced air heating systems
                                                                                    often have a G wire to run the fan
                                                                                    independently, but not all systems
                                                                                    use a G wire.
                                   W1                        Y1

                                    W2                      Y2

                                    RH                      O

26                                             GLAS smart thermostat installation instructions - © 2018 Johnson Controls
                                                               Traditional AC
                                                                                  HVAC System Control Board
                                                                                                       Cool
                                                                                     C    RC    Fan   Stage 1

                                                 Air Handler
                                        we
                                           red
                                   e Povice n
                               rnac De Ru
                                                                                     C    RC    G       Y1
                             Fu AUX R
                              C

                                                         C                  AUX

                                                         RC                  G

    Outdoor AC Unit
                                                         W1                  Y1

                                                          W2                Y2

                                                          RH                O

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                                       27
              Self-Powered Auxiliary Device                                   C

                                                                              R     AUX Device
                         HVAC System
                         Control Board                    Switch              AUX
                           C     RC

                                                          Relay
                                           24 VAC

                                                           Coil
     AUX Device            C     RC
                                                        AUX

                   C                       AUX

                   RC                       G

                   W1                       Y1

                    W2                     Y2

                    RH                     O

28                                    GLAS smart thermostat installation instructions - © 2018 Johnson Controls
Furnace-Powered Auxiliary Device
An integrated auxiliary system is built into a furnace or air handler that shares the same
power supply as the rest of the system and only requires a single control wire.

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                    29
                                  Furnace-Powered Auxiliary Device
                                                                               HVAC System Control Board
                                                                                             Heat            Cool
                                                                                C      RC   Stage 1   Fan   Stage 1   AUX

                                  AUX Device

                                                                                C      RC     W1      G       Y1      AUX
                            red
                          wee
                     e Povic n
                 rnac De Ru
               Fu AUX R
                C

                                           C                  AUX

     Furnace                               RC                  G

                                           W1                  Y1

                                            W2                Y2

                                               RH             O

30                                                  GLAS smart thermostat installation instructions - © 2018 Johnson Controls
Two Wire Auxiliary Device without C Terminal
An auxiliary device that has two terminals with the same label (HUM, DEHUM, or AUX)
and no C terminal requires a relay pack for operation.

Note: For information on how to obtain a relay pack, contact the nearest Johnson
      Controls® representative.

1. Connect the relay pack coil between the auxiliary device and C terminal on your GLAS device.

2. Connect the switch side of the relay pack to the two terminals on the AUX device.

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                         31
       Two Wire Auxiliary Device without C Terminal AUX Device
                                                                                   HUM 1 HUM 2

                                                HVAC System
                                                Control Board                          Switch
                                                   C      RC

                                                                                      Relay
     Humidifier                                                       24 VAC

                                                   C      RC                              Coil
                  C              AUX
                                                                                    AUX

                  RC              G

                  W1             Y1

                   W2           Y2

                   RH            O

32                           GLAS smart thermostat installation instructions - © 2018 Johnson Controls
Two Wire Auxiliary Device with C Terminal
An auxiliary device with one C terminal that does not require a relay pack for operation.
1. Connect the C terminal of the device to the C terminal on the furnace or air handler.

2. Connect the AUX terminal of your GLAS device to the control terminal on the
   auxiliary device.

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                   33
            Two Wire Auxiliary Device with C Terminal
                                              HVAC System
                                                                                   AUX Device
                                              Control Board
                                                C      RC
                                                                                    C     AUX

     2-Wire AUX Device
                                                       RC
                                                                                          AUX
                                                C                                   C

                         C              AUX

                         RC              G

                         W1             Y1

                          W2           Y2

                          RH            O

34                             GLAS smart thermostat installation instructions - © 2018 Johnson Controls
                                                       Dual-Stage Heat            HVAC System Control Board
                                                                                                Heat      Heat
                                                                                     C     R   Stage 1   Stage 2

                                                                                     C     R    W1        W2

                                      red
                                   wee
                              e Po ic
                                 ev n
                          rnac D Ru
                        Fu AUX R
                         C

                                                   C                        AUX

      Furnace                                     RC                         G

                                                  W1                         Y1

                                                    W2                      Y2

                                                    RH                      O

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                                          35
                                                     Dual-Stage AC
                                                                                         HVAC System Control Board
                                                                                                             Cool      Cool
                                                                                         C     RC     Fan   Stage 1   Stage 2

                                  Air Handler                                                  RC      G       Y1        Y2
                            red
                          wee
                                                                                         C
                     e Povic n
                 rnac De Ru
               Fu AUX R
                C

                                            C                          AUX

                                            RC                           G
     AC Unit
                                            W1                          Y1

                                                W2                     Y2

                                                RH                     O

36                                                        GLAS smart thermostat installation instructions - © 2018 Johnson Controls
                                Dual-Stage Heat and Traditional AC
                                                                                      HVAC System Control Board
                                                                                             Heat    Heat            Cool
                                                                                  C    RC   Stage 1 Stage 2   Fan   Stage 1

                                                 Furnace
                                                                                  C    RC    W1       W2      G       Y1
                                           red
                                         wee
                                    e Povic n
                                rnac De Ru
                              Fu AUX R
                               C

                                                           C                AUX

                                                           RC                G
          AC Unit
                                                           W1                Y1

                                                            W2              Y2

                                                            RH              O

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                                                     37
                         Dual-Stage Heat and Dual-Stage AC
                                                                            HVAC System Control Board
                                                                                 Heat      Heat            Cool      Cool
                                                                     C     RC   Stage 1   Stage 2   Fan   Stage 1   Stage 2

                                  Furnace
                            red
                          wee
                     e Povic n
                                                                     C     RC     W1       W2       G        Y1        Y2
                 rnac De Ru
               Fu AUX R
                C

                                            C                  AUX

                                            RC                  G
     AC Unit
                                            W1                  Y1

                                             W2               Y2

                                             RH                O

38                                                GLAS smart thermostat installation instructions - © 2018 Johnson Controls
                                                      Dual-Stage Heat Pump
                                                                                      HVAC System Control Board
                                                                                                  Compressor Commands
                                                                                                       Heat/Cool    Reversing
                                                                                  C     RC    G     Stage 1 Stage 2   Valve

                                                   Furnace
                                             red
                                           wee
                                                                                  C     RC    G        Y1      Y2       O
                                      e Povic n
                                  rnac De Ru
                                Fu AUX R
                                 C

                                                             C              AUX

                                                             RC              G
         Heat Pump
                                                             W1              Y1

                                                              W2            Y2

                                                              RH            O

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                                                       39
             Dual-Stage Heat Pump with Auxiliary Heat
                                                                            HVAC System Control Board
                                                                             Aux Heat Commands Compressor Commands
                                                                                    Heat            Heat/Cool    Reversing
                                                                       C    RC     Stage 1  Fan  Stage 1 Stage 2   Valve

                                Furnace                                C    RC      W1      G       Y1      Y2       O

                          red
                         wee
                    e Po ic
                       ev n
                rnac D Ru
              Fu AUX R
               C

                                          C                      AUX

                                          RC                      G

 Heat Pump                                W1                     Y1

                                           W2                   Y2

                                           RH                    O

40                                              GLAS smart thermostat installation instructions - © 2018 Johnson Controls
                         Heat Pump with Dual-Stage Auxiliary Heat
                                                                                       HVAC System Control Board
                                                                                      Aux Heating Commands Compressor Commands
                                                                                               Heat   Heat              Cool Reversing
                                                                                  C   RC     Stage 1 Stage 2  Fan      Stage 1 Valve

                                                                                  C   RC      W1       W2       G       Y1       O

                                             C                              AUX

         Heat Pump
                                            RC                               G

                                            W1                               Y1

                                              W2                            Y2

                                              RH                            O

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                                                            41
              Traditional Heat/AC with Dual Transformers
                                       Air Handler/Cooling
          Boiler/Heat Control Board        Control Board
               C      R     W1         C        R    Y1     G

                                 C         AUX

                                                                                                       Air Handler
                                 RC         G
                                                                                                 red
                                                                                               wee
                                                                                          e Povic n
                                                                                      rnac De Ru
                                                                                    Fu AUX R
                                                                                     C

                                 W1         Y1

                                  W2       Y2

                                  RH       O

     Boiler                                                     Outdoor AC Unit
42                                     GLAS smart thermostat installation instructions - © 2018 Johnson Controls
Regulatory information to user
FCC Part 15C/Industry Canada Radio Equipment Standards
1. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

2. This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
Cet appareil est conforme aux flux RSS exemptés de licence d’Industrie Can-ada. L’opération est soumise aux deux conditions suivantes:
(1) Cet appareil ne doit pas provoquer d’interférence; et
(2) Cet appareil doit accepter toute interférence, y compris les interférences pouvant entraîner un fonctionnement indésirable de l’appareil.

CAN ICES-3 (B)/NMB-3(B)

RF Safety Statement
· This device complies with the RF safety requirements for Canada and the USA as per RSS-102 and FCC Part 1.1310, RF Exposure
radiation limits for the General Population / Uncontrolled Exposure.
· This device shall be installed to maintain a separation distance of at least 20 cm (8 in) from the general population.

Changes or modifications not expressly approved by Johnson Controls will void your authority to operate this device. Warranty can be found at
www.glas.johnsoncontrols.com/legal/warranty.

GLAS smart thermostat installation instructions - © 2018 Johnson Controls                                                                       43
44   GLAS smart thermostat installation instructions - © 2018 Johnson Controls
Part No. 24-11158-00016, Rev. D

Документ виробника, опублікований як довідковий матеріал на обладнання, яке ми постачаємо. Правовласник може попросити прибрати його — приберемо.