# Манометр (датчик) дифференциального давления с контактами переключения — DPGS43HP.1X0

> Для технологической отрасли — высокая перегрузочная стойкость до 40, 100, 250 или 400 бар

- Код каталога: dpgs43hp_100_dpgs43hp_160
- Модель: DPGS43HP.1X0
- Категория: Измерение давления › Contact pressure gauges
- Страница товара: https://avigan.com.ua/wika/ru/products/dpgs43hp_100_dpgs43hp_160
- Цена: по запросу
- Поставщик: AVIGAN (ООО «ВИКА Прилад»), официальный партнёр WIKA в Украине

## Описание

Модели DPGS43HP.100, DPGS43HP.160. Дифманометр с контактами переключения ✓Для промышленности технологических процессов ►К информации!

## Применение

- Control and regulation of processes
- Monitoring of plants and switching of circuits
- For measuring locations with a high differential pressure overload and/or high operating pressures (static pressures), also in aggressive environments
- Easy-to-read, analogue on-site indication needing no auxiliary power
- Pump monitoring and control, filter monitoring, level measurement on closed vessels

## Особенности

- High operating pressure (static pressure) and high overload safety, selectable up to 40, 100, 250, 400 or 650 bar [580, 1,450, 3,625, 5,800 or 9,425 psi]
- Hydraulic cushioning protection against rapid pressure changes
- Instruments with inductive contacts for use in hazardous areas
- Instruments with switch contact for PLC applications
- QR code on dial links to instrument-specific information

## Технические характеристики

| Параметр | Значение |
|---|---|
| model | DPGS43HP.1x0 |
| product family | DPGS43HP |
| short description | Differential pressure gauge with switch contacts for the process industry, high overload safety up to 650 bar |
| subcategory | Differential pressure gauge with switch contacts |
| certifications | CE; RoHS; NACE MR0175/ISO 15156; NACE MR0103/ISO 17945; NACE MR0175 / ISO 15156; NACE MR0103 / ISO 17945; EAC; REACH |
| explosion protection | ATEX; IECEx; II 2G Ex ia IIC T6/T5/T4 Gb; II 2D Ex ia IIIB T135°C Db; Ex ia IIC T6/T5/T4 Gb; Ex ia IIIB T135°C Db |
| ambient temp | -20 … 60 °C |
| ip rating | IP65 |
| weight kg | 4.5 |
| languages in datasheet | en; de |
| pressure ranges | 0 … 0.25 bar; 0 … 0.4 bar; 0 … 0.6 bar; 0 … 1 bar; 0 … 1.6 bar; 0 … 2.5 bar; 0 … 4 bar; 0 … 6 bar; 0 … 60 mbar; 0 … 100 mbar; 0 … 160 mbar; 0 … 250 mbar; 0 … 400 mbar; 0 … 600 mbar; 0 … 6 kPa; 0 … 10 kPa; 0 … 16 kPa; 0 … 25 kPa; 0 … 40 kPa; 0 … 60 kPa; 0 … 70 kPa; 0 … 100 kPa; 0 … 160 kPa; 0 … 200 kPa; 0 … 250 kPa; -0.6 … 0 bar; -1 … 0 bar; -1 … 1 bar; -1 … 1.5 bar; -1 … 2 bar; -1 … 3 bar; -1 … 4 bar; -60 … 0 kPa; -100 … 0 kPa; -2 … 4 kPa; -4 … 6 kPa; -6 … 10 kPa; -10 … 15 kPa; -15 … 15 kPa; -100 … 100 kPa; -100 … 150 kPa; 0 … 7 bar; 0 … 10 bar; 0 … 14 bar; 0 … 16 bar; 0 … 20 bar; 0 … 25 bar; 0 … 30 bar; 0 … 40 bar; 0 … 1000 mbar; 0 … 1100 mbar; 0 … 1200 mbar; 0 … 1600 mbar; 0 … 2500 mbar; 0 … 10 psi; 0 … 15 psi; 0 … 30 psi; 0 … 60 psi; 0 … 100 psi; 0 … 150 psi; 0 … 160 psi; 0 … 300 kPa; 0 … 400 kPa; 0 … 600 kPa; 0 … 700 kPa; 0 … 800 kPa; 0 … 1000 kPa; 0 … 1400 kPa; 0 … 1600 kPa; 0 … 2500 kPa; 0 … 3000 kPa; 0 … 4000 kPa; -1 … 5 bar; -1 … 7 bar; -1 … 9 bar; -1 … 10 bar; -1 … 15 bar; -1 … 24 bar; -1 … 30 bar; -60 … 0 mbar; -100 … 0 mbar; -160 … 0 mbar; -250 … 0 mbar; -400 … 0 mbar; -600 … 0 mbar; -1000 … 0 mbar; -1100 … 0 mbar; -1200 … 0 mbar; -100 … 200 kPa; -100 … 300 kPa; -100 … 400 kPa; -100 … 500 kPa; -100 … 700 kPa; -100 … 900 kPa; -100 … 1000 kPa; -100 … 1500 kPa; -100 … 2400 kPa; 0 … 50 bar; 0 … 60 bar; 0 … 100 bar; 0 … 150 bar; 0 … 160 bar; 0 … 200 bar; 0 … 250 bar; 0 … 300 bar; 0 … 400 bar; 0 … 500 bar; 0 … 600 bar; 0 … 700 bar; 0 … 800 bar; 0 … 1000 bar; 0 … 1100 bar; 0 … 1200 bar; 0 … 1600 bar; 0 … 2400 bar; 0 … 3000 bar; 0 … 4000 bar; 0 … 200 psi; 0 … 250 psi; 0 … 300 psi; 0 … 400 psi; 0 … 500 psi; 0 … 600 psi; -15 … 0 inHg; -30 … 0 inHg; -30 … 15 inHg; -30 … 30 inHg; -30 … 60 inHg; -30 … 100 inHg; -30 … 160 inHg; -30 … 200 inHg; -30 … 300 inHg |
| accuracy class | 1.6 |
| accuracy standard | EN 837-3 |
| process connections | Flange with differential pressure connection; 2 x G ½, female thread; 2 x G ½ B, male thread; 2 x ½ NPT, male thread; G ½, female thread; G ½ B, male thread; ½ NPT, male thread; 2xG1/2, female thread; 2xG1/2B, male thread; 2x1/2NPT, male thread |
| case material | Stainless steel 1.4404 (316L); Stainless steel 1.4571 (316Ti); Stainless steel 1.4301 (304) |
| wetted parts material | Stainless steel 316L; Hastelloy C276; Monel 2.4375; Monel 2.4360; Stainless steel 316L / NiCr alloy (Inconel) |
| sealing material | FPM/FKM |
| dial size mm | 100 |
| process temp | -20 … 200 °C |
| output signal | Magnetic snap-action contact; Inductive contact; Electronic contact; Reed switch |
| electrical connection | Cable socket, black Per VDE 0110 insulation group C/250 V Cable gland M20 x 1.5 |
| switching function | Change-over |
| switching contacts | 3 |

## Таблицы из даташита

### Accuracy specifications

| Accuracy class | ■ 1.6 ■ 2.5 ■ 1.0 (application test required) |
|---|---|
| Zero point setting |  |
| Instruments with case filling | External setting |
| Instruments without case filling | Without |
| Influence of static pressure | Depending on scale range and pressure rating →See table &#x27;Influence of static pressure&#x27; |
| Temperature error | On deviation from the reference conditions at the measuring system: ≤ ±0.5 %per 10 °C [≤ ±0,5 %per 18 °F] of full scale value |
| Switch hysteresis | Depending on the type of contact used, see from page 6 |
| Reference conditions |  |
| Ambient temperature | +20 °C [+68 °F] |

| 1 | 2 | 3 | 4 | 5 | 6 |
|---|---|---|---|---|---|
| Span 1) | Measuring deviation relative to the static pressure in %per 10 bar 2) 3) |  |  |  |  |
|  | PN 40 | PN 100 | PN 250 | PN 400 | PN 650 |
| 0.06 ... 0.16 bar [0.9 ... 2.3 psi] | ≤ ±0.125 | ≤ ±0.1 | ≤ ±0.12 | - | - |
| 0.25 bar [3.6 psi] | ≤ ±0.125 | ≤ ±0.15 | - | - | - |
| 0.4 bar [5.8 psi] | ≤ ±0.125 | ≤ ±0.1 | ≤ ±0.1 | - | - |
| 0.6 ... 40 bar [8.7 ... 580 psi] | ≤ ±0.125 | ≤ ±0.1 | ≤ ±0.06 | ≤ ±0.063 | ≤ ±0.038 |

| mbar | 2 |
|---|---|
| 0 ... 60 | 0 ... 1,000 |
| 0 ... 100 | 0 ... 1,100 |
| 0 ... 160 | 0 ... 1,200 |
| 0 ... 250 | 0 ... 1,600 |
| 0 ... 400 | 0 ... 2,500 |
| 0 ... 600 | - |

| bar | 2 |
|---|---|
| 0 ... 0.25 | 0 ... 7 |
| 0 ... 0.4 | 0 ... 10 |
| 0 ... 0.6 | 0 ... 14 |
| 0 ... 1 | 0 ... 16 |
| 0 ... 1.6 | 0 ... 20 |
| 0 ... 2.5 | 0 ... 25 |
| 0 ... 4 | 0 ... 30 |
| 0 ... 6 | 0 ... 40 |

### psi

| 0 ... 10 | 0 ... 200 |
|---|---|
| 0 ... 15 | 0 ... 250 |
| 0 ... 30 | 0 ... 300 |
| 0 ... 60 | 0 ... 400 |
| 0 ... 100 | 0 ... 500 |
| 0 ... 150 | 0 ... 600 |
| 0 ... 160 | - |

| kPa | 2 |
|---|---|
| 0 ... 6 | 0 ... 300 |
| 0 ... 10 | 0 ... 400 |
| 0 ... 16 | 0 ... 600 |
| 0 ... 25 | 0 ... 700 |
| 0 ... 40 | 0 ... 800 |
| 0 ... 60 | 0 ... 1,000 |
| 0 ... 70 | 0 ... 1,400 |
| 0 ... 100 | 0 ... 1,600 |
| 0 ... 160 | 0 ... 2,500 |
| 0 ... 200 | 0 ... 3,000 |
| 0 ... 250 | 0 ... 4,000 |

### mbar

| -60 ... 0 | -10 ...+50 |
|---|---|
| -100 ... 0 | -20 ...+80 |
| -160 ... 0 | -40 ...+120 |
| -250 ... 0 | -50 ...+50 |
| -400 ... 0 | -50 ...+200 |
| -600 ... 0 | -80 ...+80 |
| -1,000 ... 0 | -100 ...+150 |
| -1,100 ... 0 | -200 ...+600 |
| -1,200 ... 0 | -500 ...+500 |

### bar

| -0.6 ... 0 | -1 ...+5 |
|---|---|
| -1 ... 0 | -1 ...+7 |
| -1 ...+1 | -1 ...+9 |
| -1 ... +1.5 | -1 ...+10 |
| -1 ...+2 | -1 ...+15 |
| -1 ...+3 | -1 ...+24 |
| -1 ...+4 | -1 ...+30 |

### Further details on: scale ranges

| 1 | 2 | 3 |
|---|---|---|
| Unit | ■ mbar ■ bar ■ psi ■ mmH 2 O ■ inH 2 O ■ kg/cm 2 |  |
| Overload safety and max. operating pressure (static pressure) |  |  |
| Pressure ratings PN 40 ...PN 400 | Max. 40, 100, 250 or 400 bar [580, 1,450, 3,625 or 5,800 psi] On one, both and alternatingly on the ⊕and ⊖sides |  |
| Pressure rating PN 650 | Max. 400 bar [5,800 psi] on one side and alternatingly on the ⊕and ⊖sides Max. 650 bar [9,425 psi] on both sides on the ⊕and ⊖sides |  |
| Dial |  |  |
| Scale layout | ■ Single scale ■ Dual scale |  |
| Scale colour | Single scale | Black |
| Dual scale | Black/red |  |
| Material | Aluminium |  |
| Customer-specific version | ■ Without ■ With special scale, e.g. linear pressure or square root incrementation |  |
| → Other scales, e.g. with red mark, circular arcs or circular sectors, on request →Alternatively, adhesive label set for red and green circular arcs; see data sheet AC 08.03 |  |  |
| Instrument pointer | Aluminium, black |  |
| Set pointer | Aluminium, red |  |

### kPa

| -60 ... 0 | -100 ...+200 |
|---|---|
| -100 ... 0 | -100 ...+300 |
| -2 ...+4 | -100 ...+400 |
| -4 ...+6 | -100 ...+500 |
| -6 ...+10 | -100 ...+700 |
| -10 ...+15 | -100 ...+900 |
| -15 ...+15 | -100 ... +1,000 |
| -100 ...+100 | -100 ... +1,500 |
| -100 ...+150 | -100 ... +2,400 |

| Output signal | 2 |
|---|---|
| Electronic contact, model 830 E | ■ For direct triggering of a programmable logic controller (PLC) ■ Long service life due to non-contact switching ■ Low influence on the indication accuracy ■ Fail-safe switching at high switching frequency ■ Insensitive to corrosion |
| Reed switch, model 851 | ■ No control unit and no supply voltage required ■ Direct switching up to 250 V, 1 A ■ For direct triggering of a programmable logic controller (PLC) ■ Wear-free, as non-contact |
| Contact setting | ■ Contact(s) adjustable, adjustment key attached to cable socket ■ Contact(s) fixed, without adjustment lock 1) ■ Adjustment lock sealable (tamper-proof) ■ Adjustment lock sealed (tamper-proof) 1) ■ Captive adjustment key with the adjustment lock connected |

### Output signal: magnetic snap-action contact, model 821

| Type of contact | Magnetic snap-action contact |
|---|---|
| Switch technology | ■ No control unit and no supply voltage required ■ Direct switching up to 250 V, 1 A |
| Number of switch contacts | Max. 3 switch contacts With measuring span < 100 mbar, max. 2 switch contacts |
| Switching function | ■ Separate circuits with ≥ 2 switches ■ Cable break monitoring with parallel resistance (47 kΩ or 100 kΩ) |
| The switching function of each switch is indicated by index 1, 2 or 3 |  |
| Model 821.1 | Normally open (clockwise pointer motion) |
| Model 821.2 | Normally closed (clockwise pointer motion) |
| Model 821.3 | Change-over; one contact breaks and one contact makes simultaneously when pointer reaches set point |
| Switch point setting | Set pointers of the contact pressure gauges are freely adjustable over the full scale range |
| Setting range (recommended) | 25 ... 75 %of span 1) |
| Distance between switch points | Recommended minimum distance between 2 contacts: 20 %of span |
| Switch hysteresis | 2 ... 5 %(typical) |
| Switching current | 0.02 ... 0.3 A (resistive load) Permissible switch-on and switch-off current: ≤ 0.5 A |
| Switching voltage 1) | AC/DC 24 ...250V |
| Switching power |  |
| Instruments without filling | ≤ 30 W, ≤ 50VA |
| Instruments with filling | ≤ 20 W, ≤ 20VA |
| Contact material | Silver-nickel, gold-plated |

| 1 | 2 | 3 | 4 | 5 | 6 | 7 |
|---|---|---|---|---|---|---|
| Switching voltage | Instruments without filling | Instruments with filling |  |  |  |  |
|  | Resistive load | Inductive load | Resistive load | Inductive load |  |  |
|  | Direct current | Alternating current | cos ϕ>0.7 | Direct current | Alternating current | cos ϕ>0.7 |
| DC 220 V / AC 230 V | 100mA | 120mA | 65mA | 65mA | 90mA | 40mA |
| DC 110 V / AC 110 V | 200mA | 240mA | 130mA | 130mA | 180mA | 85mA |
| DC 48 V / AC 48 V | 300mA | 450mA | 200mA | 190mA | 330mA | 130mA |
| DC 24 V / AC 24 V | 400mA | 600mA | 250mA | 250mA | 450mA | 150mA |

### Output signal: Inductive contact, model 831

| Type of contact | Inductive contact |
|---|---|
| Switch technology | ■ Suitable for use in hazardous areas with corresponding control unit (model 904.xx) ■ Long service life due to non-contact switching ■ Low influence on the indication accuracy ■ Fail-safe switching at high switching frequency ■ Insensitive to corrosion |
| Number of switch contacts | Max. 3 switch contacts With measuring span < 100 mbar, max. 2 switch contacts |
| Switching function | Contact versions: ■ 831-N ■ 831-SN, safety version 1) ■ 831-S1N, safety version 1) , inverted signal The switching function of each switch is indicated by index 1 or 2 |
| Model 831.1 | Normally open (clockwise pointer motion) |
| Model 831.2 | Normally closed (clockwise pointer motion) |
| Switch point setting | Set pointers of the contact pressure gauges are freely adjustable over the full scale range |
| Setting range (recommended) | 10 ... 90 %of span 2) |
| Distance between switch points | Up to 2 contacts can be set to an identical set point. For a version with 3 contacts this is not possible.The left (1st contact) or right (3rd contact) contact may not be set to the same set point as the other two contacts.The required displacement is approx. 30°, optionally to the right or to the left. |
| Switching current | Depending on the control unit used, see data sheet AC 08.04 |
| Switching voltage | Depending on the control unit used, see data sheet AC 08.04 |
| Switching power | Depending on the control unit used, see data sheet AC 08.04 |
| Permissible temperature ranges in hazardous areas |  |
| T6 | -20 ...+60 °C |
| T4 ...T1 | -20 ...+70 °C |
| T135°C | -20 ...+70 °C |
| Safety-related characteristic values (Ex) 3) |  |
| Max. input voltage U i | 16V |
| Max. input current Ii | 25mA |
| Max. input power Pi | 64mW |
| Effective internal capacitance Ci | 30 nF |
| Effective internal inductance Li | 100 µH |

| Model | Version | Ex version |
|---|---|---|
| 904.28 KFU8-SR-Ex1.W | 1 contact | Yes |
| 904.29 KFU8-SR-Ex2.W | 2 contacts | Yes |
| 904.30 KHA6-SH-Ex1 | 1 contact | Yes - Safety version |
| 904.33 KFD2-SH-Ex1 | 1 contact | Yes - Safety version |

### Output signal: electronic contact, model 830 E

| Type of contact | Electronic contact (PNP transistor) |
|---|---|
| Switch technology | ■ For direct triggering of a programmable logic controller (PLC) ■ Long service life due to non-contact switching ■ Low influence on the indication accuracy ■ Fail-safe switching at high switching frequency ■ Insensitive to corrosion |
| Number of switch contacts | Max. 3 switch contacts With measuring span < 100 mbar, max. 2 switch contacts |
| Switching function | Contact versions: ■ 2-wire system ■ 3-wire system |
| The switching function of each switch is indicated by index 1 or 2 |  |
| Model 830 E.1 | Normally open (clockwise pointer motion) |
| Model 830 E.2 | Normally closed (clockwise pointer motion) |
| Setting range (recommended) | 10 ... 90 %of span 1) |
| Distance between switch points | Up to 2 contacts can be set to an identical set point. For a version with 3 contacts this is not possible.The left (1st contact) or right (3rd contact) contact may not be set to the same set point as the other two contacts.The required displacement is approx. 30°, optionally to the right or to the left. |
| Switching current | ≤ 100mA |
| Switching voltage | DC 10 ...30V |

| Output signal: Reed switch, model 851 | 2 |
|---|---|
| Type of contact | Bistable reed switch |
| Switch technology | ■ No control unit and no supply voltage required ■ Direct switching up to 250 V, 1 A ■ For direct triggering of a programmable logic controller (PLC) ■ Wear-free, as non-contact |
| Number of switch contacts |  |
| NS 100 | Max. 2 switch contacts |
| NS 160 | 1 switch contact |
| Switching function | ■ Separate circuits with ≥ 2 switches ■ Cable break monitoring with parallel resistance (47 kΩ or 100 kΩ) |
|  | The switching function of this switch is indicated by index 3 |
| Model 851.3 | 1 x change-over; one contact breaks and one contact makes simultaneously when pointer reaches set point |
| Switch point setting | Set pointers of the contact pressure gauges are freely adjustable within 10 ...90% of span |
| Setting range (recommended) | 10 ... 90 %of span |
| Distance between switch points | When using two contacts, these cannot be set to the same point. Depending on the switching function, a minimum clearance of 15 ... 30° is required. |
| Switch hysteresis | 3 ...5% |
| Switching current | ≤ AC/DC 1 A |
| Switching voltage | ≤ AC/DC 250V |
| Switching power | ≤ 60 W, 60VA |
| Contact material | Rhodium |
| Transport current | AC/DC 2 A |
| Inductive load cosϕ | 1 |
| Contact resistance (static) | 100mΩ |
| Insulation resistance | 10 9 Ω |
| Breakdown voltage | DC 1,000V |
| Switching time incl. contact bounce | 4.5 ms |

### Electrical connection

| Connection type | ■ Cable socket, black PerVDE 0110 insulation group C/250V Cable gland M20 x 1.5 ■ Connector |
|---|---|
| Wire cross-section | 6 screw terminals + PE for 2.5 mm² |
| Cable diameter | Use cable with a diameter of 7 ... 13 mm[0.276 ... 0.512 in] |
| Pin assignment | The pin assignment is given on the product label of the instrument.The connection and grounding terminals are appropriately marked. |
| Material | PA 6 (polyamide) |

### Operating conditions

| Medium temperature range | ■ -20 ... 100 °C [-4 ...+212 °F] ■ +200 °C [+392 °F] maximum |
|---|---|
| Ambient temperature range | ■ -20 ...+60 °C [-4 ...+140 °F] |
| Storage temperature range | -20 ...+60 °C [-4 ... 140 °F] |
| Pressure limitation |  |
| Steady | Full scale value |
| Fluctuating | 0.9 x full scale value |
| Ingress protection per IEC/EN 60529 | ■ IP54 ■ IP65 1) ■ IP66 (application test required) |

| Description | Region |
|---|---|
| EU declaration of conformity | European Union |
| Pressure Equipment Directive PS > 200 bar, module A, pressure accessory |  |
| EMCDirective |  |
| LowVoltage Directive |  |
| RoHS |  |

## Документация

- [ds_pv2713_en_co_4e8761](https://avigan.com.ua/wika/docs/wika/ds_pv2713_en_co.pdf) — PDF, 1155 KB, en

## Конфигуратор

У товара есть интерактивный конфигуратор на странице товара.

```
DPGS43HP. . Z P - - 3-LM- 14 ZZ-ZZZZ
```