# HART ® field temperature transmitter — TIF50, TIF52

> Field temperature transmitters with HART® protocol, available in various field case variants for general use in process engineering.

- Catalog code: tif50_tif52
- Model: TIF50, TIF52
- Category: Temperature measurement › Digital indicators
- Product page: https://avigan.com.ua/wika/en/products/tif50_tif52
- Price: on request
- Supplier: AVIGAN (TOV VIKA Prylad), official WIKA partner in Ukraine

## Overview

The TIF series field temperature transmitters, consisting of a rugged field housing, model T32 temperature transmitter and a model DIH display, have been ...

## Applications

- Plant construction
- Process engineering
- General industrial applications
- Oil and gas

## Special features

- Setting of units and measuring range possible on site (only model TIF52)
- Different hazardous area approvals
- The following settings are possible via external software: Duplex sensor, redundant measurement possible Customer-specific characteristic curves programmable
- Duplex sensor, redundant measurement possible
- Customer-specific characteristic curves programmable

## Specifications

| Parameter | Value |
|---|---|
| model | TIF50, TIF52 |
| product family | TIF |
| short description | Field temperature transmitters with HART® protocol, available in various field case variants for general use in process engineering. |
| subcategory | Field temperature transmitter |
| certifications | CE; RoHS; EAC; ATEX; IECEx; REACH |
| explosion protection | II 2G Ex db IIC T4/T5/T6 Gb; Ex ia [ia Ga] IIC T4/T5/T6 Gb; Ex ia IIIC T135 °C Db; 1 Ex d IIC T6 ... T4; 0 Ex ia IIC T4/T5/T6; 1 Ex ib [ia ] IIC T4/T5/T6; DIP A20 Ta 120 °C; DIP A21 Ta 120 °C; ATEX; IECEx; Ex d IIC T6...T4; II(1)2G Ex ia[ia Ga]IIC T4/T5/T6 Gb; II 2D Ex ia IIC T135℃ Db; DIP A20 Ta 120℃; DIP A21 Ta 120℃ |
| ambient temp | -60 … 85 °C |
| ip rating | IP66 |
| weight kg | 1.5 |
| languages in datasheet | en; de |
| temperature ranges | -200 … 850 °C; -270 … 1300 °C; -200 … 500 °C; -60 … 250 °C; -210 … 1200 °C; -200 … 900 °C; -270 … 1000 °C; -270 … 400 °C; -200 … 600 °C; -50 … 1768 °C; 0 … 1820 °C |
| sensor type | Pt100, Pt(x), JPt100, Ni100, Type J, K, L, E, N, T, U, R, S, B, mV sensor |
| sensor class | IEC 60751:2008, JIS C1606:1989, DIN 43760:1987, DIN 43710:1985 |
| output signal | HART; 4-20mA; 4-20 mA |
| power supply | 14.5 ... 42 V DC |
| electrical connection | 2-wire |
| accuracy class | ±0.03 % of measuring span |

## Datasheet tables

| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
|---|---|---|---|---|---|---|---|
| Field temperature | Max. configurable measuring range 1) | Standard | α values | Minimum measuring span 14) | Typical measuring deviation 2) | Temperature coefficient per °C typical 3) |  |
| Resistance sensor | Pt100 | -200 ...+850 °C | IEC 60751 :2008 | α = 0.00385 | 10 K or 3.8Ω (greater value applies) | ≤ ±0.12 °C 5) | ≤ ±0.0094 °C 6) 7) |
| Pt(x) 4) 10 ... 1000 | -200 ...+850 °C | IEC 60751:2008 | α = 0.00385 | ≤ ±0.12 °C 5) | ≤ ±0.0094 °C 6) 7) |  |  |
| JPt100 | -200 ...+500 °C | JIS C1606: 1989 | α = 0.003916 | ≤ ±0.12 °C 5) | ≤ ±0.0094 °C 6) 7) |  |  |
| Ni100 | -60 ...+250 °C | DIN 43760: 1987 | α = 0.00618 | ≤ ±0.12 °C 5) | ≤ ±0.0094 °C 6) 7) |  |  |
| Resistance sensor | 0 ...8,370Ω |  |  | 4Ω | ≤ ±1.68Ω 8) | ≤ ±0.1584Ω 8) |  |
| Potentiometer 9) | 0 ...100% |  |  | 10% | ≤ 0.50% 10) | ≤ ±0.0100% 10) |  |
| Measuring current during measurement | Max. 0.3 mA(Pt100) |  |  |  |  |  |  |
| Connection methods | 1 sensor 2-/4-/3-wire or 2 sensors 2-wire (for further information, please refer to &#x27;Designation of connection terminals&#x27;) |  |  |  |  |  |  |
| Max. lead resistance | 50 Ωeach wire, 3-/4-wire |  |  |  |  |  |  |
| Thermo - couple | Type J (Fe-CuNi) | -210 ... +1,200 °C | IEC 60584-1: 1995 |  | 50 K or2mV (greater value applies) | ≤ ±0.91 °C 11) | ≤ ±0.0217 °C 7) 11) |
| Type K (NiCr-Ni) | -270 ... +1,300 °C | IEC 60584-1: 1995 |  | ≤ ±0.98 °C 11) | ≤ ±0.0238 °C 7) 11) |  |  |
| Type L (Fe-CuNi) | -200 ...+900 °C | DIN 43760: 1987 |  | ≤ ±0.91 °C 11) | ≤ ±0.0203 °C 7) 11) |  |  |
| Type E (NiCr-Cu) | -270 ... +1,000 °C | IEC 60584-1: 1995 |  | ≤ ±0.91 °C 11) | ≤ ±0.0224 °C 7) 11) |  |  |
| Type N (NiCrSi-NiSi) | -270 ... +1,300 °C | IEC 60584-1: 1995 |  | ≤ ±1.02 °C 11) | ≤ ±0.0238 °C 7) 11) |  |  |
| TypeT (Cu-CuNi) | -270 ...+400 °C | IEC 60584-1: 1995 |  | ≤ ±0.92 °C 11) | ≤ ±0.0191 °C 7) 11) |  |  |
| Type U (Cu-CuNi) | -200 ...+600 °C | DIN 43710: 1985 |  | ≤ ±0.92 °C 11) | ≤ ±0.0191 °C 7) 11) |  |  |
| Type R (PtRh-Pt) | -50 ... +1,768 °C | IEC 60584-1: 1995 |  | 150 K | ≤ ±1.66 °C 11) | ≤ ±0.0338 °C 7) 11) |  |
| Type S (PtRh-Pt) | -50 ... +1,768 °C | IEC 60584-1: 1995 |  | 150 K | ≤ ±1.66 °C 11) | ≤ ±0.0338 °C 7) 11) |  |
| Type B (PtRh-Pt) | 0 ... +1,820 °C 15) | IEC 60584-1: 1995 |  | 200 K | ≤ ±1.73 °C 11) | ≤ ±0.0500 °C 7) 12) |  |
| mVsensor | -500 ...+1,800mV |  |  | 4mV | ≤ ±0.33mV 13) | ≤ ±0.0311mV 7) 13) |  |
| Connection methods | 1 sensor or 2 sensors (for further information, please refer to &#x27;Designation of connection terminals&#x27;) |  |  |  |  |  |  |
| Max. lead resistance | 5 kΩ each wire |  |  |  |  |  |  |
| Cold junction compensation, configurable | internal compensation or external with Pt100, with thermostat or off |  |  |  |  |  |  |

| Display, operating unit | Model TIF50 | Model TIF52 |
|---|---|---|
| Display principle | LCD, rotatable in 10° steps |  |
| Measured value of display | 7-segment LCD, 5-digit, character size9mm |  |
| Bar graph | 20-segment LCD |  |
| Info line | 14-segment LCD, 6-digit, character size 5.5mm |  |
| Status indicators | ♥ :HART ® mode (signalling of HART ® parameter adoption) : Unit lock :Warnings or error messages |  |
| Indication range | -9999 ... 99999 |  |
| Measuring rate | approx. 4/s |  |
| Accuracy | ±0.1 %of measuring span | ±0.05 %of measuring span |
| Temperature coefficient | ±0.1 %of measuring span / 10 K |  |
| HART ® functionality |  |  |
| ■ Access control | - | Secondary master |
| ■ Automatically set parameters |  |  |
| ■ Available commands | - | Unit, measuring range start/end, format, zero point, span, damping, polling address |
| ■ Identified commands | Generic mode: 1, 15, 35, 44 | Generic mode: 0, 1, 6, 15, 34, 35, 36, 37, 44 |
| ■ Multidrop | Not supported | Measured values are automatically taken from the HART ® digital data and displayed |

### Rise time, damping, measuring rate

| Rise time t 90 | Approx. 0.8 s |
|---|---|
| Damping , configurable | Off ; configurable between 1 s and 60 s |
| Switch-on time (time to get the first measured value) | Max. 15 s |
| Measuring rate 1) | Measured value update approx. 3/s |

### Analogue output, output limits, signalling, insulation resistance

| 1 | 2 | 3 |
|---|---|---|
| Analogue output , configurable | Linear to temperature per IEC 60751 / JIS C1606 / DIN 43760 (for resistance sensors) or linear to temperature per IEC 584 / DIN 43710 (for thermocouples) 4 ... 20 mAor 20 ... 4 mA, 2-wire |  |
| Output limits , configurable per NAMUR NE43 customer-specifically adjustable | Lower limit 3.8 mA 3.6 ...4.0mA | upper limit 20.5 mA 20.0 ...21.5mA |
| Current value for signalling, configurable per NAMUR NE43 Substitute value | Downscale < 3.6 mA (3.5 mA) 3.5 ...12.0mA | upscale > 21.0 mA(21.5 mA) 12.0 ...23.0mA |
| In simulation mode, independent from input signal, simulation value configurable from 3.5 ...23.0mA |  |  |
| Load R A (without HART ® ) | R A ≤ (U B - 13.5 V) / 0.023 A with R A in Ωand U B inV |  |
| Load R A (with HART ® ) | R A ≤ (U B - 14.5 V) / 0.023 A with R A in Ωand U B inV |  |
| Insulation voltage (input to analogue output) | AC 1,200V (50 Hz / 60 Hz); 1 s |  |
| Insulation specification to DIN EN 60664-1:2003 | Overvoltage category III |  |

### Explosion protection, power supply

| 1 | 2 | 3 | 4 | 5 | 6 |
|---|---|---|---|---|---|
| Model | Approvals | Permissible ambient/storage temperature (in accordance with the relevant temperature | Safety-related maximum values | Power supply U B (DC) |  |
|  |  | classes) | Sensor (Connections 1 - 4) | Current loop (Connections ±) |  |
| TIF50-S, TIF52-S | without | {-50} -40 ...+85 °C | - | - | 14.5 ...42V |
| TIF50-F, TIF52-F | Flameproof enclosure BVS 10 ATEX E 158 IECEx BVS 10.0103 II 2G Ex db IIC T4/T5/T6 Gb | -40 ...+85 °C at T4 -40 ...+75 °C at T5 -40 ...+60 °C at T6 | - | U M = 30V P M =2W | 14.5 ...30V |
|  | Ex db IIC T4/T5/T6 Gb |  |  |  |  |
| TIF50-F, TIF52-F | Flameproof enclosure TC RU C-DE.BH02.B.00466/20 1 Ex d IIC T6 ...T4 | -60 2) / -40 ...+85 °C at T4 -60 2) / -40 ...+75 °C at T5 -60 2) / -40 ...+60 °C at T6 | - | U M = 30V P M =2W | 14.5 ...30V |
| TIF50-I, TIF52-I | Intrinsically safe equipment 1) BVS 16 ATEX E 112 X IECEx BVS 16.0075X |  | see installation drawing in the operating instructions at | see installation drawing in the operating instructions at | 14.5 ...29V |
|  | II (1)2G II 2G Ex ia [ia Ga] IIC T4/T5/T6 Gb Ex ia IIC T4/T5/T6 Gb | -40 ...+85 °C at T4 -40 ...+70 °C at T5 -40 ...+55 °C at T6 | www.wika.com | www.wika.com |  |
|  | II (1)2D II 2D Ex ia [ia Da] IIIC T135 °C Db Ex ia IIIC T135 °C Db | -40 ...+40 °C (P i = 680 mW) -40 ...+70 °C (P i = 650 mW) |  |  |  |
| TIF50-I, TIF52-I | Intrinsically safe equipment 1) TC RU C-DE.AЯ45.B.00918 |  | see installation drawing in | see installation drawing in | 14.5 ...29V |
|  | 0 Ex ia IIC T4/T5/T6 1 Ex ib [ia ] IIC T4/T5/T6 | -60 2) / -40 ...+85 °C at T4 -60 2) / -40 ...+70 °C at T5 -60 2) / -40 ...+55 °C at T6 | the operating instructions at www.wika.com | the operating instructions at www.wika.com |  |
|  | DIP A20Ta 120 °C DIP A21Ta 120 °C | -60 2) / -40 ...+40 °C (P i = 680 mW) -60 2) / -40 ...+70 °C (P i = 650 mW) |  |  |  |

### Measuring deviation, temperature coefficient, long-term stability

| 1 | 2 | 3 | 4 |
|---|---|---|---|
|  |  | Not measurable |  |
| Power supply effect | Not measurable |  |  |
| Warm-up time | After approx. 5 minutes the instrument will function to the specifications (accuracy) |  |  |
| Input | Measuring deviation per DIN EN 60770, 23 °C ±3 K | Mean temperature coefficient (TC) for each 10 K change in ambient temperature in the range -40 ... +85 °C Lead resistance effects | Long-term stability after 1 year |
| ■ Resistance thermometer Pt100/JPt100/ Ni100 1) | -200 °C ≤ MV≤200 °C: ±0.10 K MV>200 °C: ±(0.1 K + 0.01 %\|MW-200 K\|) 2) | ±(0.06 K + 0.015%MV) 4-wire: no effect (0 to 50 Ωeach wire) 3-wire: ±0.02 Ω/ 10Ω 50 Ωeach wire) | ±60 mΩor 0.05 %of MV, greater value applies |
| ■ Resistance sensor | ≤ 890 Ω: 0.053Ω 4) or 0.015%MV 5) ≤ 2,140 Ω: 0.128Ω 4) or 0.015%MV 5) ≤ 4,390 Ω: 0.263Ω 4) or 0.015%MV 5) ≤ 8,380 Ω: 0.503Ω 4) or 0.015%MV 5) | (0 to 2-wire: Resistor of the ±(0.01 Ω+0.01%MV) |  |
| ■ Potentiometer | R part /R total is max.±0.5% | ±(0.1%MV) |  |
| ■ Thermocouples Type E, J | -150 °C < MV<0°C: ±(0.3 K + 0.2 %\|MV\|) MV>0°C: ±(0.3 K + 0.03%MV) | Type E: MV>-150 °C: ±(0.1 K + 0.015 %\|MV\|) Type J: MV>-150 °C: ±(0.07 K + 0.02 %\|MV\|) 6 µV / 1,000Ω 6) | ±20 µV or 0.05 %of MV, greater value applies |
| Type T, U | -150 °C < MV<0°C: ±(0.4 K + 0.2 %\|MV\|) MV>0°C: ±(0.4 K + 0.01%MV) | -150 °C < MV<0°C: ±(0.07 K + 0.04%MV) MV>0°C: ±(0.07 K + 0.01%MV) |  |
| Type R, S | 50 °C < MV<400 °C: ±(1.45 K + 0.12 %\|MV - 400 K\|) 400 °C < MV<1,600 °C: ±(1.45 K + 0.01 %\|MV - 400 K\|) | Type R: 50 °C < MV<1,600 °C: ±(0.3 K + 0.01 %\|MV- 400 K\|) Type S: 50 °C < MV<1,600 °C: ±(0.3 K + 0.015 %\|MV- 400 K\|) |  |
| Type B | 450 °C < MV<1,000 °C: ±(1.7 K + 0.2 %\|MV - 1,000 K\|) MV>1,000 °C: ±1.7 K | 450 °C < MV<1,000 °C: ±(0.4 K + 0.02 %\|MV - 1,000 K\|) MV>1,000 °C: ±(0.4 K + 0.005 %(MV- 1,000 K)) |  |
| Type K | -150 °C < MV<0°C: ±(0.4 K + 0.2 %\|MV\|) 0 °C < MV<1,300 °C: | -150 °C < MV<1,300 °C: ±(0.1 K + 0.02 %\|MV\|) |  |
| Type L | -150 °C < MV<0°C: ±(0.3 K + 0.1 %\|MV\|) MV>0°C:±(0.3 K + 0.03%MV) | -150 °C < MV<0°C: ±(0.07 K + 0.02 %\|MV\|) MV>0°C:±(0.07 K + 0.015%MV) |  |
| Type N | -150 °C < MV<0°C: ±(0.5 K + 0.2 %\|MV\|) MV>0°C:±(0.5 K + 0.03%MV) | -150 °C < MV<0°C: ±(0.1 K + 0.05 %\|MV\|) MV>0°C:±(0.1 K + 0.02%MV) |  |
| ■ mVsensor | ≤1,160 mV: 10 μV + 0.03 %\|MV\| >1,160 mV: 15 μV + 0.07% \|MV\| | 2 μV + 0.02 %\|MV\| 100 μV + 0.08 %\|MV\| |  |
| ■ Cold junction 7) | ±0.8 K | ±0.1 K | ±0.2 K |
| Output | ±0.03 %of measuring span | ±0.03 %of measuring span | ±0.05 %of span |

### Pt100 / 4-wire / measuring range 0 ... 150 °C / ambient temperature 33 °C

| Input Pt100, MV<200 °C | ±0.100 K |
|---|---|
| Output ±(0.03 %of 150 K) | ±0.045 K |
| TC 10 K - input ±(0.06 K + 0.015 %of 150 K) | ±0.083 K |
| TC 10 K - output ±(0.03 %of 150 K) | ±0.045 K |
| Measuring deviation (typical) √input² + output² +TC input ² +TC output ² | ±0.145 K |
| Measuring deviation (maximum) (input + output +TC input +TC output ) | ±0.273 K |

### Thermocouple type K / measuring range 0 ... 400 °C / internal compensation (cold junction) / ambient temperature 23 °C

| Input type K, 0 °C < MV<1,300 °C ±(0.4 K + 0.04 %of 400 K) | ±0.56 K |
|---|---|
| Cold junction ±0.8 K | ±0.80 K |
| Output ±(0.03 %of 400 K) | ±0.12 K |
| Measuring deviation (typical) √input² + cold junction² + output² | ±0.98 K |
| Measuring deviation (maximum) (input + cold junction + output) | ±1.48 K |

### Monitoring

| Test current for sensor monitoring 1) | Nom.20 µA during test cycle, otherwise 0 µA |
|---|---|
| Monitoring NAMUR NE89 (monitoring of input lead resistance) |  |
| ■ Resistance thermometer (Pt100, 4-wire) | R L1 + R L4 > 100 Ωwith hysteresis5Ω R L2 + R L3 > 100 Ωwith hysteresis5Ω |
| ■ Thermocouple | R L1 + R L4 + R thermocouple > 10 kΩ with hysteresis 100Ω |
| Sensor break monitoring | Always active |
| Self-monitoring | Active permanently, e.g.RAM/ROM test, logical program operating checks and validity check |
| Measuring range monitoring | Monitoring of the set measuring range for upper/lower deviations Standard: Deactivated |
| Monitoring of input lead resistance (3-wire) | Monitoring of the resistance difference between lead 3 and 4; an error will be indicated if there is a difference of > 0.5 Ωbetween leads 3 and 4 |

### Field case

| 1 | 2 | 3 |
|---|---|---|
| Material | ■ Aluminium, window from polycarbonate ■ Stainless steel, window from polycarbonate |  |
| Colour | Aluminium: Night blue, RAL 5022 | Stainless steel: Silver |
| Cable bushings | 3 x M20 x 1.5 or3x½NPT |  |
| Ingress protection | IP66 |  |
| Weight | Aluminium: approx. 1.5 kg | Stainless steel: approx. 3.7 kg |
| Dimensions | See drawing |  |

### Ambient conditions

| Ambient temperature | -60 1) / -40 ...+85 °C |
|---|---|
| Functional area of the display | -20 2) ...+70 °C |
| Climate class per IEC 654-1: 1993 | Cx (-20 ...+85 °C, 35 ... 85 %r.h., non-condensing) |
| Maximum permissible humidity | 93 %r.h.±3% |
| Vibration resistance per IEC 60068-2-6:2007 | 3 g |
| Shock resistance per IEC 68-2-27: 1987 | 30 g |
| Electromagnetic compatibility (EMC) | EN 61326 emission (group 1, class B) and interference immunity (industrial application), and also NAMUR NE21 |

| Model | Description | Order number |
|---|---|---|
| Programming unit, model PU-H |  |  |
| VIATOR ® HART ® USB | HART ® modem for USB interface | 11025166 |
| VIATOR ® HART ® USB PowerXpress™ | HART ® modem for USB interface | 14133234 |
| VIATOR ® HART ® RS-232 | HART ® modem for RS-232 interface | 7957522 |
| VIATOR ® HART ® Bluetooth ® Ex | HART ® modem for Bluetooth interface, Ex | 11364254 |
| Magnetic quick connector magWIK | ■ Replacement for crocodile clips and HART ® terminals ■ Fast, safe and tight electrical connection ■ For all configuration and calibration processes | 14026893 |

| Logo | Description | Region |
|---|---|---|
|  | EU declaration of conformity | European Union |
|  | EMCdirective EN 61326 emission (group 1, class B) and interference immunity (industrial application) |  |

| Logo | Description | Region |
|---|---|---|
|  | EU declaration of conformity | European Union |
|  | ATEX directive Hazardous areas |  |
|  | IECEx Hazardous areas | International |
|  | EAC | Eurasian Economic Community |
|  | EMCdirective |  |
|  | Hazardous areas 1) |  |
|  | PAC Russia Metrology, measurement technology | Russia |
|  | PAC Kazakhstan Metrology, measurement technology | Kazakhstan |
| - | MChS Permission for commissioning | Kazakhstan |
|  | PAC Belarus Metrology, measurement technology | Belarus |
|  | PAC Ukraine Metrology, measurement technology | Ukraine |
|  | DNOP - MakNII | Ukraine |
|  | Mining |  |
|  | Hazardous areas |  |
| - | PESO Hazardous areas | India |

### Certificates

| Certificates | ■ 2.2 test report |
|---|---|
|  | ■ 3.1 inspection certificate |
| Calibration | ■ DAkkS calibration certificate |

## Documents

- [ds_te6201_en_co_35b58e](https://avigan.com.ua/wika/docs/wika/ds_te6201_en_co.pdf) — PDF, 823 KB, en