# Tension/compression force transducer — SPP-F2812

> Tension/compression force transducer with measuring ranges from 0 ... 50 N to 0 ... 1,000 N, stainless steel construction, IP65 protection, suitable for static and dynamic force measurement in industrial applications.

- Catalog code: spp_f2812
- Model: SPP-F2812
- Category: Force measurement › Tension/compression force transducers
- Product page: https://avigan.com.ua/wika/en/products/spp_f2812
- Price: on request
- Supplier: AVIGAN (TOV VIKA Prylad), official WIKA partner in Ukraine

## Overview

The model F2812 tension/compression force transducer is designed for static and dynamic measurement tasks in the direct flux of force.

## Applications

- Tension/compression force testing
- Tank weighing
- Load monitoring in industrial plants
- Riveting machine
- Welding machine

## Special features

- Measuring ranges 0 ... 50 N up to 0 ... 1,000 N
- Ultra compact design
- Corrosion-resistant stainless steel design
- Protection IP65

## Specifications

| Parameter | Value |
|---|---|
| model | F2812 |
| product family | F2812 |
| short description | Tension/compression force transducer with measuring ranges from 0 ... 50 N to 0 ... 1,000 N, stainless steel construction, IP65 protection, suitable for static and dynamic force measurement in industrial applications. |
| subcategory | Tension/compression force transducer |
| certifications | CE; RoHS; EAC; EU declaration of conformity; EMC directive; RoHS directive; EAC (option) |
| ambient temp | -20 … 80 °C |
| ip rating | IP65 |
| weight kg | 0.1 |
| languages in datasheet | en |
| force ranges | 0 … 50 N; 0 … 100 N; 0 … 150 N; 0 … 200 N; 0 … 300 N; 0 … 500 N; 0 … 600 N; 0 … 1000 N |
| accuracy class | ±0.5 % Fnom |
| output signal | 2.0 ±0.2 mV/V |
| mounting type | Tension, compression |
| cell material | Stainless steel |
| overload protection percent | 120 |
| process temp | -10 … 40 °C |
| cable length m | 3 |

## Datasheet tables

| Model F2812 | 2 |
|---|---|
| Rated force F nom N | 50 / 100 / 150 / 200 / 300 / 500 / 600 / 1,000 |
| Relative linearity error din lin 1) | ±0.5%F nom |
| Relative reversibility error v | ±0.5%F nom |
| Relative repeatability error in unchanged mounting position b rg | ±0.25%F nom |
| Relative deviation of zero signal d S,0 | ±2%F nom |
| Temperature effect on zero signalTK 0 | ≤ ±0.2 %/ 10 K |
| Temperature effect on characteristic value TK C | ≤ ±0.2 %/ 10 K |
| Force limit F L | 120%F nom |
| Breaking force F B | 200%F nom |
| Material of the measuring body | Stainless steel |
| Rated temperature range B T, nom | -10 ...+40 °C |
| Operating temperature range B T, G | -20 ...+80 °C |
| Input resistance R e | 700 ±30Ω |
| Output resistance R a | 700 ±5Ω |
| Insulation resistance R is | ≥ 5,000 MΩ/DC 100V |
| Output signal (rated characteristic value) C nom | 2.0 ±0.2 mV/V |
| Electrical connection | Measuring cable ∅3x3,000mm |
| Voltage supply |  |
| Standard | DC 5 ...10V |
| Option | DC 12 …28Vintegrated or cable amplifier 0 (4) ...20mA DC 0 ...10V DC 0 ...5V |
| Ingress protection (per IEC/EN 60529) | IP65 |
| Weight in kg | 0.1 |

| Logo | Description | Region |
|---|---|---|
|  | EU declaration of conformity | European Union |
|  | EMCdirective |  |
|  | RoHS directive |  |
|  | EAC (option) | Eurasian Economic Community |
|  | EMCdirective |  |

| Rated force in N | M |
|---|---|
| 5 / 100 / 150 / 200 / 300 / 500 | M5 |
| 600 / 1,000 | M6 |

### Electrical connection

| Excitation voltage (+) | Red |
|---|---|
| Excitation voltage (-) | Black |
| Signal (+) | Green |
| Signal (-) | White |
| Shield | Shield |

## Documents

- [ds_fo5149_en_co_e1019c](https://avigan.com.ua/wika/docs/wika/ds_fo5149_en_co.pdf) — PDF, 327 KB, en

## Configurator

This product has an interactive configurator on its product page.

```
SPP-F2812-M2 CAA4K010300 XXXXXXXXXX
```