# Pressure sensor with wireless transmission — PEW-1000

> For general industrial applications

- Catalog code: pew_1000
- Model: PEW-1000
- Category: Pressure measurement › Pressure sensors
- Product page: https://avigan.com.ua/wika/en/products/pew_1000
- Price: on request
- Supplier: AVIGAN (TOV VIKA Prylad), official WIKA partner in Ukraine

## Overview

The model PEW-1000 is a radio-based pressure sensor for monitoring liquids and gases. It uses the licence-free LoRaWAN ® or mioty ® and Bluetooth ® radio ...

## Applications

- Industrial pressure measurement for gases and liquids

## Special features

- Low operating costs through intelligent measurementcontrol
- Easy integration thanks to several radio-standard options
- Numerous application possibilities – also as retrofit
- Robustly built, permanently reliable pressure measurement
- Risk minimisation through condition monitoring

## Specifications

| Parameter | Value |
|---|---|
| model | PEW-1000 |
| product family | PEW |
| short description | Radio-based pressure sensor for monitoring liquids and gases with LoRaWAN®, mioty®, or Bluetooth® connectivity for industrial applications. |
| subcategory | Wireless pressure sensor |
| certifications | CE; RoHS |
| ambient temp | -20 … 80 °C |
| ip rating | IP65 |
| weight kg | 0.125 |
| languages in datasheet | en |
| pressure ranges | 0 … 1 MPa; 0 … 0.04 MPa; 0 … 0.1 MPa; 0 … 0.16 MPa; 0 … 0.25 MPa; 0 … 0.4 MPa; 0 … 0.6 MPa; 0 … 1.6 MPa; 0 … 2.5 MPa; 0 … 100 psi; 0 … 160 psi; 0 … 0.4 bar; 0 … 1 bar; 0 … 1.6 bar; 0 … 2.5 bar; 0 … 4 bar; 0 … 6 bar; 0 … 10 bar; 0 … 16 bar; 0 … 25 bar; -1 … 0 bar; -1 … 9 bar; -1 … 1 bar; -1 … 15 bar; -0.2 … 0.2 bar; -1 … 24 bar; -0.1 … 0 MPa; -0.1 … 0.1 MPa; -0.1 … 0.9 MPa; -0.1 … 1.5 MPa; -0.1 … 2.4 MPa; 0 … 1000 psi; 0 … 1500 psi; 0 … 30 psi; 0 … 50 psi; 0 … 200 psi; 0 … 40 bar; 0 … 60 bar; 0 … 100 bar; 0 … 160 bar; 0 … 250 bar; 0 … 400 bar; 0 … 600 bar; 0 … 1000 bar; 0 … 4 MPa; 0 … 6 MPa; 0 … 10 MPa; 0 … 16 MPa; 0 … 25 MPa; 0 … 40 MPa; 0 … 100 MPa; 0 … 0.4 bar abs.; 0 … 6 bar abs.; 0 … 1 bar abs.; 0 … 10 bar abs.; 0 … 1.6 bar abs.; 0 … 16 bar abs.; 0 … 2.5 bar abs.; 0 … 25 bar abs.; 0 … 4 bar abs.; 0 … 0.04 MPa abs.; 0 … 0.6 MPa abs.; 0 … 0.1 MPa abs.; 0 … 1 MPa abs.; 0 … 0.16 MPa abs.; 0 … 1.6 MPa abs.; 0 … 0.25 MPa abs.; 0 … 2.5 MPa abs.; 0 … 0.4 MPa abs.; 0 … 1 psi; 0 … 300 psi; 0 … 5 psi; 0 … 500 psi; 0 … 15 psi; 0 … 25 psi; 0 … 2000 psi; 0 … 3000 psi; 0 … 5000 psi; 0 … 10000 psi; 0 … 15000 psi; 5 … 70 psi abs.; 10 … 150 psi abs.; 15 … 300 psi abs.; -14.5 … 0 psi; -14.5 … 15 psi; -14.5 … 160 psi; -14.5 … 200 psi; -14.5 … 300 psi; 0 … 40 psi; 0 … 4 kPa; 0 … 60 psi; 0 … 6 kPa; 0 … 10 kPa; 0 … 16 kPa; 0 … 250 psi; 0 … 25 kPa; 0 … 400 psi; 0 … 40 kPa; 0 … 600 psi; 0 … 60 kPa; 0 … 100 kPa; 0 … 150 kPa |
| accuracy class | 0.25 % BFSL |
| accuracy standard | IEC 62828-1 |
| process connections | 7/16-20 UNF O-ring BOSS; G ¼ B; G ½ B; G ¼ A; G ½ A; ¼ NPT; ½ NPT; R ¼; PT ¼; M10 x 1; M12 x 1.5; M14 x 1.5; G 3/4 A; R 3/8; PT 3/8; R 1/2; PT 1/2; G1/4B; G1/2B; G1/4B, female; G1/4A; G1/2A; 1/4NPT; 1/2NPT; R1/4; PT1/4 |
| case material | Stainless steel 316L; PBT |
| wetted parts material | Stainless steel 316L |
| sealing material | Copper; Stainless steel; NBR; FPM/FKM |
| process temp | -20 … 80 °C |
| output signal | LoRaWAN®; mioty®; Bluetooth® |
| power supply | DC 3.6 V |
| electrical connection | Battery pack (Tadiran SL860/S) |

## Datasheet tables

### Overview of versions

| Model PEW-1000 (Lxx) | Version with LoRaWAN ® and Bluetooth ® |
|---|---|
| Model PEW-1000 (Mxx) | Version with mioty ® and Bluetooth ® |
| Model PEW-1000 (Bxx) | Version with Bluetooth ® |
| → The fields marked with xx are the respective regional abbreviations of the permissible radio standards, for further information, see product label or operating instructions. |  |

### Accuracy specifications

| 1 | 2 | 3 |
|---|---|---|
| Non-linearity per BFSL per IEC 62828-1 | ≤ ±0.25 %of span |  |
| Accuracy | →See&#x27;Maximum measured error per IEC 62828-1&#x27; |  |
| Maximum measured error per IEC 62828-1 | ≤ ±0.5 %of span |  |
| Zero point setting | ±3 %of span |  |
| Signal noise | ≤ 0.2 %of span |  |
| Non-repeatability per IEC 62828-1 | ≤ 0.1 %of span |  |
| Total probable error per IEC 62828-2 | → See diagram &#x27;Total probable error per IEC 62828-2&#x27; |  |
| Long-term drift per IEC 62828-1 | ≤ ±0.2 %of span |  |
| ≤ ±0.25 %for measuring range 0.4 bar |  |  |
| Reference conditions | Per IEC 62828-1 |  |
| Accuracy specifications of the temperature value |  |  |
| Measuring range | -20 ...+80 °C [-4 ...+176 °F] |  |
| Accuracy | →See&#x27;Max.measuring deviation&#x27; |  |
| Max. measuring deviation | For measuring range -20 ...+60 °C [-4 ...+140 °F] | ±3.5 K |
| For measuring range 60 ... 80 °C [140 ... 176 °F] | ±4.75 K |  |

| bar | 2 |
|---|---|
| 0 ... 0.4 | 0 ... 40 |
| 0 ... 1 | 0 ... 60 |
| 0 ... 1.6 | 0 ... 100 |
| 0 ... 2.5 | 0 ... 160 |
| 0 ... 4 | 0 ... 250 |
| 0 ... 6 | 0 ... 400 |
| 0 ... 10 | 0 ... 600 |
| 0 ... 16 | 0 ... 1,000 |
| 0 ... 25 | - |

| psi | 2 |
|---|---|
| 0 ... 1 | 0 ... 300 |
| 0 ... 5 | 0 ... 500 |
| 0 ... 15 | 0 ... 1,000 |
| 0 ... 25 | 0 ... 1,500 |
| 0 ... 30 | 0 ... 2,000 |
| 0 ... 50 | 0 ... 3,000 |
| 0 ... 100 | 0 ... 5,000 |
| 0 ... 160 | 0 ... 10,000 |
| 0 ... 200 | 0 ... 15,000 |

### bar abs.

| 0 ... 0.4 | 0 ... 6 |
|---|---|
| 0 ... 1 | 0 ... 10 |
| 0 ... 1.6 | 0 ... 16 |
| 0 ... 2.5 | 0 ... 25 |
| 0 ... 4 | - |

### psi abs.

| 0 ... 5 | 0 ... 70 |
|---|---|
| 0 ... 10 | 0 ... 150 |
| 0 ... 15 | 0 ... 300 |
| 0 ... 30 | - |

### bar

| -1 ... 0 | -1 ...+9 |
|---|---|
| -1 ...+1 | -1 ...+15 |
| -0.2 ... +0.2 | -1 ...+24 |

### psi

| -14.5…0 | -14.5 …+15 |
|---|---|
| -14.5 …+160 | -14.5 …+200 |
| -14.5 …+300 | - |

### MPa

| 0 ... 0.04 | 0 ... 4 |
|---|---|
| 0 ... 0.1 | 0 ... 6 |
| 0 ... 0.16 | 0 ... 10 |
| 0 ... 0.25 | 0 ... 16 |
| 0 ... 0.4 | 0 ... 25 |
| 0 ... 0.6 | 0 ... 40 |
| 0 ... 1 | 0 ... 60 |
| 0 ... 1.6 | 0 ... 100 |
| 0 ... 2.5 | - |

### MPa abs.

| 0 ... 0.04 | 0 ... 0.6 |
|---|---|
| 0 ... 0.1 | 0 ... 1 |
| 0 ... 0.16 | 0 ... 1.6 |
| 0 ... 0.25 | 0 ... 2.5 |
| 0 ... 0.4 | - |

### Further details on: Measuring range

| Units | ■ bar ■ psi ■ MPa |
|---|---|
| Maximum working pressure | →Corresponds to the upper measuring range value / measuring range full scale value |
| Overpressure limit per IEC 62828-1 | The overpressure limit is based on the measuring range. Depending on the selected process connection and the seal, restrictions in overpressure limit can result. |
| Measuring ranges < 10 bar | 3 times |
| Measuring ranges ≥ 10 ...≤ 600 bar | 2 times |
| Measuring ranges > 600 bar | 1.43 times |
| Vacuum resistance | Yes |

### Process connection

| Standard | Thread size | Max. measuring range | Overpressure limit | Seal |
|---|---|---|---|---|
| EN 837 | G¼B | 1,000 bar [15,000 psi] | 1,430 bar [21,450 psi] | ■ Copper ■ Stainless steel |
| G½B |  |  |  |  |
| G¼B,female 1) | 1,000 bar [15,000 psi] | 1,430 bar [21,450 psi] | - |  |
| DIN EN ISO 1179-2 (formerly DIN 3852-E) | G¼A | 600 bar [8,700 psi] | 858 bar [12,440 psi] | ■ NBR ■ FPM/FKM |
| G½A | 400 bar [5,800 psi] | 572 bar [8,294 psi] | ■ NBR ■ FPM/FKM |  |
| ANSI/ASME B1.20.1 | ¼NPT 1) | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] | - |
| ½NPT 1) |  |  |  |  |
| ISO 7 | R¼ 1) | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] | - |
| KS | PT¼ 1) | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] | - |
| SAE J514 | 7/16-20 UNF O-ring BOSS | 600 bar [8,700 psi] | 858 bar [12,440 psi] | ■ FKM ■ NBR |

### Further details on: Process connection

| Max. measuring range | → See table &#x27;&#x27;Process connection&#x27; on page 4 |
|---|---|
| Overpressure limit | → See table &#x27;&#x27;Process connection&#x27; on page 4 |
| Seal | → See table &#x27;&#x27;Process connection&#x27; on page 4 |
| Pressure port diameter | 3.5 mm[0.14 in] |
|  | → Restrictor on request |

| Radio standard | 2 |
|---|---|
| LoRaWAN ® |  |
| Functions | ■ Registration ■ Configuration ■ Sending measured values ■ Alarm management ■ Battery status |
| Range in free field | Typically 10 km [6 mi] → Depending on the ambient conditions, such as topography and building structures. |
| Antenna | PCB antenna, internal |
| Transmission power | Max.+14 dBm |
|  | Maximum 7 days |
| Safety |  |
|  | Full end-to-end encryption → For details on security, see website: https://lora-alliance.org |
| mioty ® |  |
| Specification | Regional Profile EU1 |
| Functions | ■ Registration ■ Sending measured values ■ Alarm management ■ Battery status |
| Range in free field | Typically 10 km [6 mi] → Depending on the ambient conditions, such as topography and building structures. |
| Antenna | PCB antenna, internal |
| Transmission power | Max.+14 dBm |
| Bluetooth ® |  |
| Version | Bluetooth ® 5.0 or newer → Compatible with all Bluetooth® Low Energy versions 4.2 or newer |
| Functions | ■ Registration ■ Configuration ■ Sending measured values ■ Alarm management ■ Battery status ■ Data logger |
| Range in free field | Typically 20 m[65 ft] → Depending on the ambient conditions, such as topography and building structures. |
| Antenna | Chip antenna, internal |
| Transmission power | Max.+14 dBm |
| Transmission interval | 1.25 seconds |
| An update of the measured value only occurs in the set measurement interval. | → |

### Voltage supply and performance data

| Battery pack | Lithium thionyl chloride battery and hybrid layer capacitor (model Tadiran HLC1020L) as an assembly with connection cable assembled. Model Tadiran SL860/S |
|---|---|
| Battery voltage | DC 3.6V |
| Battery life | > 5 years |
|  | Reference conditions: ■ Measurement interval 30 min. ■ Transmission interval 60 min. |
| Current supply |  |
| Model PEW-1000 (Lxx) and PEW-1000 (Mxx) | Max.50mA |
| Model PEW-1000 (Bxx) | Max.20mA |

### Material

| 1 | 2 | 3 |
|---|---|---|
| Material (wetted) | Stainless steel 316L |  |
| Material (in contact with the environment) | Stainless steel 316L PBT (case) |  |
| Pressure transmission medium |  |  |
| Gauge pressure measuring ranges | < 10 bar / 100 psi / 1 MPa | Synthetic oil |
| ≥ 10 bar / 100 psi / 1 MPa | Dry measuring cell |  |
| Measuring ranges, absolute pressure | ≤ 25 bar / 300 psi / 2.5 MPa | Synthetic oil |
| Vacuum and +/- measuring ranges | < 9 bar / 160 psi / 0.9 MPa | Synthetic oil |
| ≥ 9 bar / 160 psi / 0.9 MPa | Dry measuring cell |  |

### Operating conditions

| Medium temperature limit | -20 …+80 °C [-4 ...+176 °F] |
|---|---|
| Ambient temperature limit | -20 …+80 °C [-4 ...+176 °F] |
| Storage temperature limit | -40 ...+70 °C [-40 ...+158 °F] |
| Relative humidity, condensation per EN 61010-1 | 0 ... 95 %r.h. |
| Permissible pollution degree per EN 61010-1 | 2 |
| Vibration resistance per IEC 60068-2-6 | a = 1 g (7 ... 18 Hz) |
| A = 0.8 mm(18 ... 50 Hz) |  |
| a = 5 g (50 ... 200 Hz) → Due to the built-in Li battery, the values comply with the requirements of UN 38.3. |  |
| Shock resistance per IEC 60068-2-27 | 50 g, 6 ms |
| Free fall per IEC 60068-2-31 |  |
| Individual packaging | 1.2 m[3.94 ft] |
| Multiple packaging | 0.5 m[1.6 ft] |
| Ingress protection (IP code) per IEC 60529 | IP67 and IP65 |

### Alarms

| Alarms | Various alarms can be set. → See operating instructions for pressure sensor with wireless transmission, model PEW-1000 (article number 14471927). |
|---|---|

### Options for specific media

| 1 | 2 |
|---|---|
| Oil- and grease-free |  |
| Residual hydrocarbon | < 1,000 mg/m² |
| Packaging and instrument labelling |  |
| Packaging | ■ Individual packaging ■ Multiple packaging (up to 25 pieces possible) |
| Instrument labelling | ■ WIKA product label, lasered ■ Customer-specific product label on request |

| Logo | Description | Country |
|---|---|---|
|  | EU declaration of conformity | European Union |
|  | Radio Equipment Directive EN 61326 emission (group 1, class B) and immunity (industrial application) This wireless device may be used without restriction in the member states of the EU and in the countries of the EFTA. Use in other countries is not permitted. |  |
|  | RoHS directive |  |

## Documents

- [ds_pe8723_en_co_b9545c](https://avigan.com.ua/wika/docs/wika/ds_pe8723_en_co.pdf) — PDF, 702 KB, en

## Configurator

This product has an interactive configurator on its product page.

```
PEW-1000- - 1S- - - ZZZ
```