# Electromagnetic flow meter — FLC-2300

> Electromagnetic flow meter with conical profile for accurate low flow measurement, suitable for water, wastewater, and industrial slurries, with no upstream or downstream runs required.

- Catalog code: flc_2300
- Model: FLC-2300
- Category: Flow measurement › Electromagnetic flow meters
- Product page: https://avigan.com.ua/wika/en/products/flc_2300
- Price: on request
- Supplier: AVIGAN (TOV VIKA Prylad), official WIKA partner in Ukraine

## Overview

Electromagnetic flow meters are based on the Faraday principle, by which a conductor which traverses a magnetic field generates a potential oriented ...

## Applications

- Water meters
- Water and wastewater
- District metering
- Industrial process liquids, slurries and concrete

## Special features

- No upstream or downstream runs required
- Approved for custody transfer (MID MI-001, OIML R49)
- Accurate low flow measurement
- Case from stainless steel with ebonite lining

## Specifications

| Parameter | Value |
|---|---|
| model | FLC-2300 |
| product family | FLC |
| short description | Electromagnetic flow meter with conical profile for accurate low flow measurement, suitable for water, wastewater, and industrial slurries, with no upstream or downstream runs required. |
| subcategory | Electromagnetic flow meter |
| certifications | CE; OIML R49; MID MI-001; EMC EN 61326; Low Voltage Directive |
| explosion protection | ATEX (option for separated version); IECEx (option for separated version) |
| ambient temp | -40 … 80 °C |
| ip rating | IP68 |
| languages in datasheet | en |
| technology | magnetic |
| flow ranges | 0.125 … 31.25 m³/h; 0.2 … 50 m³/h; 0.315 … 78.75 m³/h; 0.5 … 125 m³/h; 0.8 … 200 m³/h; 1.25 … 312.5 m³/h; 3.15 … 787.5 m³/h; 5 … 1250 m³/h; 8 … 1250 m³/h; 0.125 … 25 m³/h; 0.2 … 40 m³/h; 0.315 … 63 m³/h; 0.5 … 100 m³/h; 0.8 … 160 m³/h; 1.25 … 250 m³/h; 3.15 … 630 m³/h; 5 … 1000 m³/h; 8 … 1000 m³/h |
| pipe diameter mm | 300 |
| accuracy percent | 0.2 |
| process connections | ANSI 150; EN 1092-1 (PN 16); AS 2129 (table D - E - F); AS 4087 (PN 16, PN 21); KS 10K; EN1092-1 (PN16); AS2129 (table D-E-F); AS4087 (PN16, PN21); KS10K |
| wetted parts material | SS304; SS316; SS316L; Titanium; Tantalum; Platinum; Hard rubber (ebonite); Hastelloy C; HastelloyC® |
| process temp | -40 … 80 °C |
| process pressure max bar | 16 |

## Datasheet tables

### Diameter

| mm | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 |
|---|---|---|---|---|---|---|---|---|---|
| in | 2 | 2.5 | 3 | 4 | 5 | 6 | 8 | 10 | 12 |

### Basic information

| Materials | 2 |
|---|---|
| Flow tube | ■ SS304 (standard) ■ SS316 |
| Flanges | ■ Carbon steel (S235JR - 1.0037) (standard) ■ SS304 ■ SS316 |
| Electrodes | ■ SS316L (standard) ■ Hastelloy C ® ■ Titanium ■ Tantalum ■ Platinum |
| Flow tube lining | Hard rubber (ebonite) 1) |
| Painting of sensor housing and flange | Acrylic paint (painting for class C4 environments on request) |
| Pressure loss class |  |
| DN ≤ 80 | ΔP25 (< 0.25 bar [3,6 psi]) |
| DN ≥ 80 | ΔP40 (< 0.4 bar [5,8 psi]) |
| Medium temperature | -40 ...+80 °C [-40 ...+176 °F] |
| Electrodes | ■ Three ■ Fourth electrode as an empty-pipe alarm, activation and deactivation via software |
| Available flange standards | EN 1092-1 (PN 16), ANSI 150, AS 2129 (table D - E - F), AS 4087 (PN 16, PN 21), KS 10K, others on request |
| Installation requirements | U0, D0 |
| Ingress protection per EN 60529 | IP68 (continuous immersion to 1.5 m[4,9 ft]) |
| Compatible signal converters | ■ Model FLC-608A/B/R/P/I ■ Model FLC-406 |
| Electrical connection | Cable gland M20 x 1.5, terminal block and sealing resin |

| 1 | 2 | 3 | 4 | 5 | 6 | 7 |
|---|---|---|---|---|---|---|
| Sensor diameter | Flow rate [m³/h] | Ratio R Q3/ Q1 |  |  |  |  |
| Minimum flow Q1 | Transition flow Q2 | Q 0.4% | Permanent flow Q3 | Overload flow Q4 |  |  |
| DN 50 [2"] | 0.125 | 0.2 | 3.5 | 25 | 31.25 | 200 |
| DN 65 [2.5"] | 0.2 | 0.32 | 6 | 40 | 50 | 200 |
| DN 80 [3"] | 0.315 | 0.5 | 9 | 63 | 78.75 | 200 |
| DN 100 [4"] | 0.5 | 0.8 | 14 | 100 | 125 | 200 |
| DN 125 [5"] | 0.8 | 1.28 | 22 | 160 | 200 | 200 |
| DN 150 [6"] | 1.25 | 2 | 32 | 250 | 312.5 | 200 |
| DN 200 [8"] | 3.15 | 5.04 | 57 | 630 | 787.5 | 200 |
| DN 250 [10"] | 5 | 8 | 90 | 1,000 | 1,250 | 200 |
| DN 300 [12"] | 8 | 12.5 | 128 | 1,000 | 1,250 | 125 |

### Model FLC-406, radial mount

| DN | H | H1 |
|---|---|---|
| DN 50 [2"] | 62 | 187 |
| DN 65 [2.5"] | 62 | 187 |
| DN 80 [3"] | 71 | 196 |
| DN 100 [4"] | 79 | 204 |
| DN 125 [5"] | 106 | 231 |
| DN 150 [6"] | 101 | 226 |
| DN 200 [8"] | 147 | 272 |
| DN 250 [10"] | 176 | 301 |
| DN 300 [12"] | 207 | 332 |

### Model FLC-406, back mount

| DN | H H1 |
|---|---|
| DN 50 [2"] | 62 188 |
| DN 65 [2.5"] | 62 188 |
| DN 80 [3"] | 71 197 |
| DN 100 [4"] | 79 205 |
| DN 125 [5"] | 106 232 |
| DN 150 [6"] | 101 227 |
| DN 200 [8"] | 147 273 |
| DN 250 [10"] | 176 302 |
| DN 300 [12"] | 207 333 |

| 1 | 2 | 3 |
|---|---|---|
| Model FLC-608 A/B/R |  |  |
| DN | H | H1 |
| DN 50 [2"] | 62 | 211 |
| DN 65 [2.5"] | 62 | 211 |
| DN 80 [3"] | 71 | 220 |
| DN 100 [4"] | 79 | 228 |
| DN 125 [5"] | 106 | 255 |
| DN 150 [6"] | 101 | 250 |
| DN 200 [8"] | 147 | 296 |
| DN 250 [10"] | 176 | 325 |
| DN 300 [12"] | 207 | 356 |

### EN 1092 / PN 16

| DN | D5 | L4 | J | Di | D6 | N | S | H |
|---|---|---|---|---|---|---|---|---|
| 50 | 85 | 200 (+0/-3) | 87.35 | 30.4 | 125 | 4 | 18 | 114.5 |
| 65 | 85 | 200 (+0/-3) | 87.35 | 34.3 | 145 | 4 | 18 | 114.5 |
| 80 | 103 | 200 (+0/-3) | 96.35 | 46.3 | 160 | 4 | 18 | 123.5 |
| 100 | 118 | 250 (+0/-3) | 103.85 | 62.1 | 180 | 8 | 18 | 131 |
| 125 | 172 | 250 (+0/-3) | 130.85 | 74.9 | 210 | 8 | 18 | 158 |
| 150 | 163 | 300 (+0/-3) | 126.35 | 100 | 240 | 8 | 22 | 153.5 |
| 200 | 255 | 350 (+0/-3) | 172.35 | 154.3 | 295 | 8 | 22 | 199.5 |
| 250 | 312 | 450 (+0/-5) | 200.85 | 205 | 350 | 12 | 22 | 228 |
| 300 | 375 | 500 (+0/-5) | 232.35 | 259 | 400 | 12 | 22 | 259.5 |

### ANSI 150

| DN | D5 | L4 | J | Di | D6 | N | S | H |
|---|---|---|---|---|---|---|---|---|
| DN 50 [2"] | 85 | 200 (+0/-3) | 87.35 | 30.4 | 120.65 | 4 | 19.05 | 114.5 |
| DN 65 [2.5"] | 85 | 200 (+0/-3) | 87.35 | 34.3 | 139.7 | 4 | 19.05 | 114.5 |
| DN 80 [3"] | 103 | 200 (+0/-3) | 96.35 | 46.3 | 152.4 | 4 | 19.05 | 123.5 |
| DN 100 [4"] | 118 | 250 (+0/-3) | 103.85 | 62.1 | 190.5 | 8 | 19.05 | 131 |
| DN 125 [5"] | 172 | 250 (+0/-3) | 130.85 | 74.9 | 215.9 | 8 | 22.352 | 158 |
| DN 150 [6"] | 163 | 300 (+0/-3) | 126.35 | 100 | 241.3 | 8 | 22.352 | 153.5 |
| DN 200 [8"] | 255 | 350 (+0/-3) | 172.35 | 154.3 | 298.45 | 8 | 22.352 | 199.5 |
| DN 250 [10"] | 312 | 450 (+0/-5) | 200.85 | 205 | 361.95 | 12 | 25.4 | 228 |
| DN 300 [12"] | 375 | 500 (+0/-5) | 232.35 | 259 | 431.8 | 12 | 25.4 | 259.5 |

### AS 2129 table D

| DN | D5 | L4 | J | Di | D6 | N | S | H |
|---|---|---|---|---|---|---|---|---|
| 50 | 85 | 200 (+0/-3) | 87.35 | 30.4 | 114 | 4 | 18 | 114.5 |
| 65 | 85 | 200 (+0/-3) | 87.35 | 34.3 | 127 | 4 | 18 | 114.5 |
| 80 | 103 | 200 (+0/-3) | 96.35 | 46.3 | 146 | 4 | 18 | 123.5 |
| 100 | 118 | 250 (+0/-3) | 103.85 | 62.1 | 178 | 4 | 18 | 131 |
| 125 | 172 | 250 (+0/-3) | 130.85 | 74.9 | 210 | 8 | 18 | 158 |
| 150 | 163 | 300 (+0/-3) | 126.35 | 100 | 235 | 8 | 18 | 153.5 |
| 200 | 255 | 350 (+0/-3) | 172.35 | 154.3 | 292 | 8 | 18 | 199.5 |
| 250 | 312 | 450 (+0/-5) | 200.85 | 205 | 356 | 8 | 22 | 228 |
| 300 | 375 | 500 (+0/-5) | 232.35 | 259 | 406 | 12 | 22 | 259.5 |

### AS 2129 table E

| DN | D5 | L4 | J | Di | D6 | N | S | H |
|---|---|---|---|---|---|---|---|---|
| 50 | 85 | 200 (+0/-3) | 87.35 | 30.4 | 114 | 4 | 18 | 114.5 |
| 65 | 85 | 200 (+0/-3) | 87.35 | 34.3 | 127 | 4 | 18 | 114.5 |
| 80 | 103 | 200 (+0/-3) | 96.35 | 46.3 | 146 | 8 | 18 | 123.5 |
| 100 | 118 | 250 (+0/-3) | 103.85 | 62.1 | 178 | 8 | 18 | 131 |
| 125 | 172 | 250 (+0/-3) | 130.85 | 74.9 | 210 | 8 | 18 | 158 |
| 150 | 163 | 300 (+0/-3) | 126.35 | 100 | 235 | 8 | 22 | 153.5 |
| 200 | 255 | 350 (+0/-3) | 172.35 | 154.3 | 292 | 8 | 22 | 199.5 |
| 250 | 312 | 450 (+0/-5) | 200.85 | 205 | 356 | 12 | 22 | 228 |
| 300 | 375 | 500 (+0/-5) | 232.35 | 259 | 406 | 12 | 26 | 259.5 |

### AS 4087 / PN 16

| DN | D5 | L4 | J | Di | D6 | N | S | H |
|---|---|---|---|---|---|---|---|---|
| 50 | 85 | 200 (+0/-3) | 87.35 | 30.4 | 114 | 4 | 18 | 114.5 |
| 65 | 85 | 200 (+0/-3) | 87.35 | 34.3 | 127 | 4 | 18 | 114.5 |
| 80 | 103 | 200 (+0/-3) | 96.35 | 46.3 | 146 | 8 | 18 | 123.5 |
| 100 | 118 | 250 (+0/-3) | 103.85 | 62.1 | 178 | 4 | 18 | 131 |
| 125 | 172 | 250 (+0/-3) | 130.85 | 74.9 | 210 | 8 | 18 | 158 |
| 150 | 163 | 300 (+0/-3) | 126.35 | 100 | 235 | 8 | 18 | 153.5 |
| 200 | 255 | 350 (+0/-3) | 172.35 | 154.3 | 292 | 8 | 18 | 199.5 |
| 250 | 312 | 450 (+0/-5) | 200.85 | 205 | 356 | 8 | 22 | 228 |
| 300 | 375 | 500 (+0/-5) | 232.35 | 259 | 406 | 12 | 22 | 259.5 |

| Logo | Description | Country |
|---|---|---|
|  | EU declaration of conformity | European Union |
|  | EMCdirective EN 61326 emission (group 1, class B) and immunity (industrial application) |  |
|  | Low voltage directive |  |
|  | ATEX directive (option for separated version) |  |
|  | IECEx (option for separated version) | International |
|  | Custody transfer |  |
| - | International Organization for Legal Metrology (OIML) | International |
| - | Measuring instrument directive (MID) | European Union |

## Documents

- [ds_fl2006_en_co_3e3610](https://avigan.com.ua/wika/docs/wika/ds_fl2006_en_co.pdf) — PDF, 1105 KB, en