# Temperature dry-well calibrator — CTD9100-375

> Portable temperature dry-well calibrator with high accuracy and stability, suitable for on-site calibration of temperature measuring instruments.

- Catalog code: ctd9100_375
- Model: CTD9100-375
- Category: Calibration technology › Portable temperature calibrators
- Product page: https://avigan.com.ua/wika/en/products/ctd9100_375
- Price: on request
- Supplier: AVIGAN (TOV VIKA Prylad), official WIKA partner in Ukraine

## Overview

The CTD9100-1100 temperature block calibrator for checking and calibrating temperature measuring instruments. Inform now.

## Applications

- Testing and calibration of temperature measuring instruments
- Reference instrument for on-site laboratories for the calibration of thermometers
- Also suitable for on-site calibration

## Special features

- High accuracy and stability
- Possibility for testing temperature switches
- Low weight and compact design
- Simple operation

## Specifications

| Parameter | Value |
|---|---|
| model | CTD9100-375 |
| product family | CTD9100 |
| short description | Portable temperature dry-well calibrator with high accuracy and stability, suitable for on-site calibration of temperature measuring instruments. |
| subcategory | Dry-well calibrator |
| certifications | RoHS; CE; EMC Directive EN 61326; Low Voltage Directive |
| ambient temp | 0 … 50 °C |
| ip rating | None |
| weight kg | 1.7 |
| languages in datasheet | en |
| calibration type | dry_block |
| temperature ranges | 0 … 375 °C |
| accuracy or uncertainty | 0.2 % of reading; min. 0.5 K |
| traceability | DAkkS |
| portable | true |

## Datasheet tables

### Operating conditions

| Place of use | For indoor and outdoor use |
|---|---|
| Altitude | To 2,000 m[6,562 ft] above sea level |
| Operating temperature | 0 ... 50 °C [32 ... 122 °F] The ambient temperature influences the heating/cooling behaviour |
| Storage and transport temperature range | -10 ...+60 °C [14 ... 140 °F] |
| Humidity | < 80 %relative humidity to 31 °C [88 °F] Decreasing linearly to 50 %relative humidity at 40 °C [104 °F] |
| Condensation | Non-condensing |

| Logo | Description | Region |
|---|---|---|
|  | EU declaration of conformity | European Union |

| Logo | Description | Region |
|---|---|---|
| - | MChS Permission for commissioning | Kazakhstan |

### Certificates

| Calibration 1) | ■ 3.1 inspection certificate per EN 10204 ■ DAkkS calibration certificate (traceable and accredited in accordance with ISO/IEC 17025) |
|---|---|
| Recommended calibration interval | 1 year (dependent on conditions of use) |

| Accessories | 2 | Order code |
|---|---|---|
| Description 1) |  | CTX-A-K3 |
| - | Insert replacement tool | -RT- |
|  | Transport case | -TB- |
|  | Power cord for EU | -EU- |
|  | Netzkabel for Switzerland | -CH- |
|  | Netzkabel for UK | -UK- |
|  | Netzkabel for USA/Canada | -US- |
| Ordering information for your enquiry: |  |  |
| 1. Order code: CTX-A-K3 ⇓ |  |  |
| 2. Option: [ ] |  |  |

| Inserts | Order code |
|---|---|
| Description 1) | CTA9I-1N |
| Undrilled insert Dimensions:Ø13 x 150 mm[Ø0.51 x 3.94 in] Material: Brass 2.0375 | -N- |
| Drilled insert Dimensions:Ø13 x 150 mm[Ø0.51 x 3.94 in] Drilling depth: 95 mm[3.74 in] Material: Brass 2.0375 | - |
| For thermometers with diameters up to 2.7 mm[0.11 in] Bore diameter: 1 x 3 mm[1 x 0.12 in] | -3- |

| Inserts | 2 | Order code |
|---|---|---|
| Description 1) | CTA9I-1N |  |
|  | For thermometers with diameters up to 3.2 mm[0.13 in] Bore diameter: 1 x 3.5 mm[1 x 0.14 in] | -4- |
|  | For thermometers with diameters up to 4.7 mm[0.19 in] Bore diameter: 1 x 5 mm[1 x 0.20 in] | -5- |
|  | For thermometers with diameters up to 6.3 mm[0.25 in] Bore diameter: 1 x 6.5 mm[1 x 0.26 in] | -6- |
|  | For thermometers with diameters up to 7.2 mm[0.28 in] Bore diameter: 1 x 7.5 mm[1 x 0.30 in] | -7- |
|  | For thermometers with diameters up to 8.2 mm[0.32 in] Bore diameter: 1 x 8.5 mm[1 x 0.33 in] | -8- |
|  | For thermometers with different diameters Bore diameter: 1 x 5.0 mmand 1 x 3.5mm [1 x 0.20 in and 1 x 0.14 in] | -I- |
|  | Bore diameter: 1 x 5.0 mmand 1 x 6.5mm [1 x 0.20 in and 1 x 0.26 in] | -X- |
|  | Bore diameter: 1 x 3.5 mmand 1 x 4.5mm [1 x 0.14 in and 1 x 0.18 in] | -K- |
|  | Bore diameter: 2 x 4.5 [2 x 0.18 in] | -L- |
| - | Customer-specific, special probes are possible on request. | -?- |
| Ordering information for your enquiry: |  |  |
| 1. Order code: CTA9I-1N 2. Option: | ⇓ [ ] |  |

## Documents

- [ds_ct4132_en_co_078578](https://avigan.com.ua/wika/docs/wika/ds_ct4132_en_co.pdf) — PDF, 558 KB, en