# Temperature dry-well calibrator — CTD9100-COOL

> Portable temperature dry-well calibrators with various temperature ranges from -50 to +650 °C, suitable for on-site calibration in industrial environments.

- Catalog code: ctd9100
- Model: CTD9100-COOL
- Category: Calibration technology › Portable temperature calibrators
- Product page: https://avigan.com.ua/wika/en/products/ctd9100
- Price: on request
- Supplier: AVIGAN (TOV VIKA Prylad), official WIKA partner in Ukraine

## Overview

The portable temperature dry well calibrator CTD9100 is particularly suited for on-site calibrations.

## Applications

- Easy on-site calibration
- Power generation
- Measurement and control laboratories
- Machine building

## Special features

- Various temperature ranges
- Measurement uncertainties from 0.15 ... 0.8 K
- Compact design
- Simple operation

## Specifications

| Parameter | Value |
|---|---|
| model | CTD9100-COOL |
| product family | CTD9100 |
| short description | Portable temperature dry-well calibrators with various temperature ranges from -50 to +650 °C, suitable for on-site calibration in industrial environments. |
| subcategory | dry-well |
| certifications | RoHS; CE |
| ambient temp | 0 … 50 °C |
| ip rating | IP20 |
| weight kg | 11 |
| languages in datasheet | en; de; es; fr |
| calibration type | dry_block |
| temperature ranges | -50 … 200 °C; -35 … 165 °C; 40 … 450 °C; 40 … 650 °C |
| accuracy or uncertainty | ±0.25 K |
| traceability | DAkkS |
| portable | true |

## Datasheet tables

| Basic information | Model CTD9100-COOL | Model CTD9100-165 |
|---|---|---|
| Temperature range | -50 ...+200 °C [-58 ...+392 °F] | ■ -35 ...+165 °C [-31 ...+329 °F] ■ -30 ...+165 °C [-22 ...+329 °F] 1) |
| Temperature stability 2) | → See &#x27;Accuracy specifications&#x27; table |  |
| Metal block |  |  |
| Immersion depth | 150 mm[5.91 in] |  |
| Dimension of the insert | Ø28 x 150 mm[Ø1.1 x 5.91 in] | ■ Ø28 x 150 mm[Ø1.1 x 5.91 in] ■ Ø60 x 150 mm[Ø2.36 x 5.91 in] 1) |
| Dry-well material | Aluminium 3.2315 |  |
| Dimensions (W x D x H) |  |  |
| Calibrator incl. carrying handle | 215 x 305 x 425 mm[8.46 x 12.00 x 16.73 in] |  |
| Height of carrying handle | 50 mm[1.97 in] |  |
| Weight | 11 kg [24.3 lb] |  |

| Basic information | Model CTD9100-450 | Model CTD9100-650 |
|---|---|---|
| Temperature range | 40 ... 450 °C [104 ... 842 °F] | 40 ... 650 °C [104 ... 1,202 °F] |
| Temperature stability 1) | → See &#x27;Accuracy specifications&#x27; table |  |
| Metal block |  |  |
| Immersion depth | 150 mm[5.91 in] |  |
| Dimension of the insert | Ø60 x 150 mm[Ø2.36 x 5.91 in] | Ø28 x 150 mm[Ø1.1 x 5.91 in] |
| Dry-well material | Aluminium 3.4365 | Brass 2.0375 |
| Dimensions (W x D x H) |  |  |
| Calibrator without carrying handle | 150 x 270 x 400 mm[5.91 x 10.63 x 15.75 in] |  |
| Height of carrying handle | 50 mm[1.97 in] |  |
| Weight | 7.5 kg [16.5 lb] | 8 kg [17.6 lb] |

### Accuracy specifications

| Model | CTD9100-COOL | CTD9100-165 | CTD9100-450 | CTD9100-650 |
|---|---|---|---|---|
| Accuracy 1) | ±0.25 K | ±0.20 K | ±0.30 K | ±0.50 K |
| Temperature stability 2) | ±0.05 K | ±0.05 K | ■ ±0.05 K to 100 °C [212 °F] ■ ±0.1 K to 450 °C [842 °F] | ■ ±0.05 K to 100 °C [212 °F] ■ ±0.1 K to 600 °C [1,112 °F] |
| Temperature distribution 1) |  |  |  |  |
| Axial homogeneity | Depending on temperature, temperature probes and their number |  |  |  |
| Radial homogeneity 3) | Depending on temperature, temperature probes and their number |  |  |  |

### Temperature control

| Heating time | 2 | 3 |
|---|---|---|
| Model CTD9100-COOL | From +20 °C to +200 °C [from +68 °F to +392 °F] | Approx. 10 min |
| Model CTD9100-165 | From +20 °C to +165 °C [from +68 °F to +329 °F] | ■ Approx. 25 min ■ Approx. 35 min model X 1) |
| Model CTD9100-450 | From +20 °C to +450 °C [from +68 °F to +842 °F] | Approx. 14 min |
| Model CTD9100-650 | From +20 °C to +600 °C [from +68 °F to +1,112 °F] | Approx. 20 min |
| Cooling time |  |  |
| Model CTD9100-COOL | From +20 °C to -20 °C [from +68 °F to -4 °F] | Approx. 10 min |
| Model CTD9100-165 | From +20 °C to -20 °C [from +68 °F to -4 °F] | ■ Approx. 15 min ■ Approx. 35 min model X 1) |
| Model CTD9100-450 | From +450 °C to +100 °C [from +842 °F to +212 °F] | Approx. 60 min |
| Model CTD9100-650 | From +600 °C to +100 °C [from +1,112 °F to +212 °F] | Approx. 60 min |
| Stabilisation time 2) | Depending on temperature and temperature probe |  |

### Communication

| Interface | RS-485 to USB |
|---|---|
| Communications protocol | Modbus ® RTU |
|  | Details and further possibilities on request |
| Baud rate | 9600 |

### Voltage supply and performance data

| Model | CTD9100-COOL | CTD9100-165 | CTD9100-450 | CTD9100-650 |
|---|---|---|---|---|
| Operating voltage 1) | AC 100 ...230V 50/60 Hz | AC 100 ...230V 50/60 Hz | AC 230V 50/60 Hz | ■ AC 230 V, 50/60 Hz 2) ■ AC 100 ... 240 V, 50/60 Hz 3) |
| Power consumption | 555VA | 375VA | 2,000VA | 1,000VA |
| Fuse | 6.3 A slow blow fuse (at AC 250 V) | 6.3 A slow blow fuse (at AC 250 V) | 10 A slow blow fuse | ■ 10 A slow blow (at AC 110 V) ■ 6.3 A slow blow (at AC 230 V) |
| Power cord | ■ Europe ■ USA/Canada ■ Switzerland ■ UK |  |  |  |

### Operating conditions

| Place of use | For indoor use only |
|---|---|
| Altitude | Up to 2,000 m[6,562 ft] above sea level |
| Operating temperature | 0 ... 50 °C [32 ... 122 °F] The ambient temperature influences the heating/cooling behaviour |
| Storage and transport temperature range | -10 ...+60 °C [14 ... 140 °F] |
| Humidity | < 80 %to 31 °C [88 °F], decreasing linearly to 50 %at 40 °C [104 °F] |
| Condensation | Non-condensing |
| Pollution degree per IEC 61010-1 | 2 |
| Overvoltage category | II |
| Mounting position | Upright/Vertical standing |

| Logo | Description | Region |
|---|---|---|
|  | EU declaration of conformity EMCDirective EN 61326 emission (group 1, class B) and immunity (industrial environment) LowVoltage Directive RoHS directive | European Union |

### Description

| Calibration 1) | ■ 3.1 inspection certificate per EN 10204 ■ DAkkS calibration certificate (traceable and accredited in accordance with ISO/IEC 17025) |
|---|---|
| Recommended calibration interval | 1 year (dependent on conditions of use) |

| 1 | 2 | 3 |
|---|---|---|
| Accessories for model CTD9100-xxxx 1) | Order code |  |
| Description | CTX-A-K1 |  |
|  | Transport case | -TB- |
|  | Castors for transport case | -CC- |
|  | Power cord EU | -EU- |
|  | Switzerland | -CH- |
|  | USA/Canada | -US- |
|  | UK | -UK- |
|  | Insert replacement tool | -RT- |
|  | Interface cable With integrated RS-485 to USB 2.0 converter | -RC- |
|  | Calibration software Software package for operating the calibrator | -CS- |
|  | Probe holder For cooling instruments of the CTD9xxx series | -FL- |
|  | Probe holder For CTD9xxx series heating instruments | -FH- |
| Ordering information for your enquiry: |  |  |
| 1. Order 2. Option: | ⇓ [ ] |  |

| 1 | 2 | 3 |
|---|---|---|
| Inserts for model CTD9100-COOL and CTD9100-165 1) | Order code |  |
| Description | CTA9I-K |  |
|  | Inserts undrilled Dimension:Ø28 x 150 mm[Ø1.1 x 5.91 in] Material: aluminium 3.2315 | -N- |
|  | Inserts drilled Dimension:Ø28 x 150 mm[Ø1.1 x 5.91 in] Drilling depth: 145 mm[5.71 in] Material: aluminium 3.2315 |  |
|  | For thermometers to Ø1.2 mm[0.05 in] Bore diameter: 1 x 1.5 mm[0.06 in] | -1- |
|  | For thermometers to Ø1.6 mm[0.07 in] Bore diameter: 1 x 2.0 mm[0.08 in] | -2- |
|  | For thermometers to Ø2.7 mm[0.11 in] Bore diameter: 1 x 3.0 mm[0.12 in] | -3- |
|  | For thermometers to Ø3.2 mm[0.13 in] Bore diameter: 1 x 3.5 mm[0.14 in] | -4- |
|  | For thermometers to Ø4.7 mm[0.19 in] Bore diameter: 1 x 5.0 mm[0.20 in] | -5- |
|  | For thermometers to Ø6.3 mm[0.25 in] Bore diameter: 1 x 6.5 mm[0.26 in] | -6- |
|  | For thermometers to Ø7.2 mm[0.28 in] Bore diameter: 1 x 7.5 mm[0.30 in] | -7- |
|  | For thermometers to Ø8.2 mm[0.32 in] Bore diameter: 1 x 8.5 mm[0.33 in] | -8- |
|  | For thermometers to Ø9.5 mm[0.37 in] Bore diameter: 1 x 10 mm[0.39 in] | -9- |
|  | For thermometers to Ø3.2 mm[0.13 in] Bore diameter: 1 x 5 mmand 1 x 3.5 mm[1 x 0.20 in and 1 x 0.14 in] | -I- |
|  | For thermometers to Ø6.3 mm[0.25 in] Bore diameter: 1 x 5 mmand 1 x 6.5 mm[1 x 0.20 in and 1 x 0.26 in] | -X- |
|  | Bore diameter: 1 x 3.2 mmand 1 x 6.3 mm[1 x 0.13 in and 1 x 0.25 in] | -A- |
|  | Bore diameter: 2 x 3.2 mm, 1 x 4.2 mm, 1 x 6.3 mm, 1 x 8.4 mmand 1 x 9.9mm [2 x 0.13 in, 1 x 0.17 in, 1 x 0.25 in, 1 x 0.33 in and 1 x 0.39 in] | -B- |
|  | Bore diameter: 2 x 3.2 mm, 2 x 4.3 mm, 3 x 6.3 mmand 2 x 8.5mm [2 x 0.13 in, 2 x 0.17 in, 3 x 0.25 in and 2 x 0.33 in] | -M- |
|  | Customer-specific, special probes are possible on request. | -?- |
|  | Insert replacement tool | -J- |
| Ordering information for your enquiry: |  |  |
| 1. Order code: 2. Option: | ⇓ [ ] |  |

| 1 | 2 | 3 |
|---|---|---|
| Inserts for models CTD9100-165-X and CTD9100-450 1) | Order code |  |
| Description | CTA9I-M |  |
|  | Inserts undrilled Dimension:Ø60 x 150 mm[Ø2.36 x 5.91 in] Material: aluminium 3.4365 | -N- |
|  | Inserts drilled Dimension:Ø28 x 150 mm[Ø1.1 x 5.91 in] Drilling depth: 145 mm[5.71 in] Material: aluminium 3.4365 |  |
|  | For thermometers to Ø1.2 mm[0.05 in] Bore diameter: 1 x 1.5 mm[0.06 in] | -1- |
|  | For thermometers to Ø1.6 mm[0.07 in] Bore diameter: 1 x 2.0 mm[0.08 in] | -2- |
|  | For thermometers to Ø2.7 mm[0.11 in] Bore diameter: 1 x 3.0 mm[0.12 in] | -3- |
|  | For thermometers to Ø3.2 mm[0.13 in] Bore diameter: 1 x 3.5 mm[0.14 in] | -4- |
|  | For thermometers to Ø4.7 mm[0.19 in] Bore diameter: 1 x 5.0 mm[0.20 in] | -5- |
|  | For thermometers to Ø6.3 mm[0.25 in] Bore diameter: 1 x 6.5 mm[0.26 in] | -6- |
|  | For thermometers to Ø7.2 mm[0.28 in] Bore diameter: 1 x 7.5 mm[0.30 in] | -7- |
|  | For thermometers to Ø8.2 mm[0.32 in] Bore diameter: 1 x 8.5 mm[0.33 in] | -8- |
|  | For thermometers to Ø9.5 mm[0.37 in] Bore diameter: 1 x 10 mm[0.39 in] | -9- |
|  | For thermometers to Ø3.2 mm[0.13 in] Bore diameter: 1 x 5 mmand 1 x 3.5 mm[1 x 0.20 in and 1 x 0.14 in] | -I- |
|  | For thermometers to Ø6.3 mm[0.25 in] Bore diameter: 1 x 5 mmand 1 x 6.5 mm[1 x 0.20 in and 1 x 0.26 in] | -X- |
|  | Bore diameter: 1 x 3.2 mmand 1 x 6.3 mm[1 x 0.13 in and 1 x 0.25 in] | -A- |
|  | Bore diameter: 2 x 3.2 mm, 1 x 4.2 mm, 1 x 6.3 mm, 1 x 8.4 mmand 1 x 9.9mm [2 x 0.13 in, 1 x 0.17 in, 1 x 0.25 in, 1 x 0.33 in and 1 x 0.39 in] | -B- |
|  | Bore diameter: 2 x 3.2 mm, 2 x 4.2 mm, 3 x 6.3 mmand 2 x 8.5mm [2 x 0.13 in, 2 x 0.17 in, 3 x 0.25 in and 2 x 0.33 in] | -M- |
|  | Customer-specific, special probes are possible on request. | -?- |
|  | Insert replacement tool | -J- |
| Ordering information for your enquiry: |  |  |
| 1. Order code: 2. Option: | ⇓ [ ] |  |

| 1 | 2 | 3 |
|---|---|---|
| Inserts for model CTD9100-650 1) | Order code |  |
| Description | CTA9I-L |  |
|  | Inserts undrilled Dimension:Ø28 x 150 mm[Ø1.1 x 5.91 in] Material: brass 2.0375 | -N- |
|  | Inserts drilled Dimension:Ø28 x 150 mm[Ø1.1 x 5.91 in] Drilling depth: 145 mm[5.71 in] Material: brass 2.0375 |  |
|  | For thermometers to Ø1.2 mm[0.05 in] Bore diameter: 1 x 1.5 mm[0.06 in] | -1- |
|  | For thermometers to Ø1.6 mm[0.07 in] Bore diameter: 1 x 2.0 mm[0.08 in] | -2- |
|  | For thermometers to Ø2.7 mm[0.11 in] Bore diameter: 1 x 3.0 mm[0.12 in] | -3- |
|  | For thermometers to Ø3.2 mm[0.13 in] Bore diameter: 1 x 3.5 mm[0.14 in] | -4- |
|  | For thermometers to Ø4.7 mm[0.19 in] Bore diameter: 1 x 5.0 mm[0.20 in] | -5- |
|  | For thermometers to Ø6.3 mm[0.25 in] Bore diameter: 1 x 6.5 mm[0.26 in] | -6- |
|  | For thermometers to Ø7.2 mm[0.28 in] Bore diameter: 1 x 7.5 mm[0.30 in] | -7- |
|  | For thermometers to Ø8.2 mm[0.32 in] Bore diameter: 1 x 8.5 mm[0.33 in] | -8- |
|  | For thermometers to Ø9.5 mm[0.37 in] Bore diameter: 1 x 10 mm[0.39 in] | -9- |
|  | For thermometers to Ø3.2 mm[0.13 in] Bore diameter: 1 x 5 mmand 1 x 3.5 mm[1 x 0.20 in and 1 x 0.14 in] | -I- |
|  | For thermometers to Ø6.3 mm[0.25 in] Bore diameter: 1 x 5 mmand 1 x 6.5 mm[1 x 0.20 in and 1 x 0.26 in] | -X- |
|  | Bore diameter: 1 x 3.2 mmand 1 x 6.3 mm[1 x 0.13 in and 1 x 0.25 in] | -A- |
|  | Bore diameter: 2 x 3.2 mm, 1 x 4.2 mm, 1 x 6.3 mm, 1 x 8.4 mmand 1 x 9.9mm [2 x 0.13 in, 1 x 0.17 in, 1 x 0.25 in, 1 x 0.33 in and 1 x 0.39 in] | -B- |
|  | Bore diameter: 2 x 3.2 mm, 2 x 4.2 mm, 3 x 6.3 mmand 2 x 8.5mm [2 x 0.13 in, 2 x 0.17 in, 3 x 0.25 in and 2 x 0.33 in] | -M- |
|  | Customer-specific, special probes are possible on request. | -?- |
|  | Insert replacement tool | -J- |
| Ordering information for your enquiry: |  |  |
| 1. Order code: 2. Option: | ⇓ [ ] |  |

## Documents

- [ds_ct4128_en_co_4d6de4](https://avigan.com.ua/wika/docs/wika/ds_ct4128_en_co.pdf) — PDF, 916 KB, en