# Reference pressure sensor — CPT6200

> Reference pressure sensor for calibration service companies, measurement and control laboratories, and pressure tests with measuring ranges from 0 ... 100 mbar to 0 ... 1,000 bar and accuracy of 0.2 % or 0.1 % (incl. calibration certificate).

- Catalog code: cpt6200_cpt62i0
- Model: CPT6200
- Category: Calibration technology › Hand-helds, calibrators
- Product page: https://avigan.com.ua/wika/en/products/cpt6200_cpt62i0
- Price: on request
- Supplier: AVIGAN (TOV VIKA Prylad), official WIKA partner in Ukraine

## Overview

Extensive application possibilities For the hand-held pressure indicators model CPH6200 and CPH6300, external reference pressure sensors of model CPT6200 ...

## Applications

- Calibration service companies and service industry
- Measurement and control laboratories
- Pressure tests

## Special features

- Measuring ranges from 0 ... 100 mbar to 0 ... 1,000 bar [0 ... 5 psi to 0 ... 14,500 psi]
- Pressure type: positive and negative pressure, absolute pressure and differential pressure
- Accuracy: 0.2 % or 0.1 % (incl. calibration certificate)
- Fast connection to digital display instrument (plug-and-play)

## Specifications

| Parameter | Value |
|---|---|
| model | CPT6200 |
| product family | CPT62 |
| short description | Reference pressure sensor for calibration service companies, measurement and control laboratories, and pressure tests with measuring ranges from 0 ... 100 mbar to 0 ... 1,000 bar and accuracy of 0.2 % or 0.1 % (incl. calibration certificate). |
| subcategory | Reference pressure sensor |
| certifications | RoHS; Pressure Equipment Directive; CE |
| explosion protection | ATEX: II 2G Ex ib IIC T4 Gb; ATEX directive Hazardous areas - Ex i Zone 1 gas II 2G Ex ib IIC T4 Gb II 2G Ex ib IIC T4; II 2G Ex ib IIC T4 Gb |
| ambient temp | 15 … 25 °C |
| ip rating | IP65 |
| weight kg | 0.22 |
| languages in datasheet | en |
| calibration type | electronic |
| pressure ranges | 0 … 100 mbar; 0 … 1000 bar; 0 … 5 psi; 0 … 14500 psi; -600 … 600 mbar; 0 … 0.25 bar abs.; 0 … 4 bar abs.; 0 … 5 psi abs.; 0 … 50 psi abs.; -1 … 1000 bar; -3 … 300 psi; 0 … 400 mbar; 0 … 160 mbar; 0 … 600 mbar; 0 … 250 mbar; 0 … 1 bar; 0 … 60 bar; 0 … 1.6 bar; 0 … 70 bar; 0 … 2.5 bar; 0 … 100 bar; 0 … 4 bar; 0 … 160 bar; 0 … 6 bar; 0 … 250 bar; 0 … 10 bar; 0 … 400 bar; 0 … 16 bar; 0 … 600 bar; 0 … 25 bar; 0 … 40 bar; 0 … 300 psi; 0 … 10 psi; 0 … 500 psi; 0 … 15 psi; 0 … 1000 psi; 0 … 20 psi; 0 … 1500 psi; 0 … 30 psi; 0 … 2000 psi; 0 … 50 psi; 0 … 3000 psi; 0 … 100 psi; 0 … 6000 psi; 0 … 150 psi; 0 … 8000 psi; 0 … 200 psi; 0 … 0.4 bar abs.; 0 … 6 bar abs.; 0 … 0.6 bar abs.; 0 … 10 bar abs.; 0 … 1 bar abs.; 0 … 16 bar abs.; 0 … 1.2 bar abs.; 0 … 25 bar abs.; 0 … 1.6 bar abs.; 0.8 … 1.2 bar abs.; 0 … 2.5 bar abs.; -19.99 … 40 mbar; -400 … 400 mbar; -19.99 … 60 mbar; -250 … 250 mbar; -600 … 0 mbar; -100 … 100 mbar; -400 … 0 mbar; -19.99 … 25 mbar; -250 … 0 mbar; -1 … 0 bar; -1 … 9 bar; -1 … 1.5 bar; -1 … 15 bar; -1 … 3 bar; -1 … 24 bar; -1 … 5 bar; -1 … 39 bar; 0 … 10 psi abs.; 0 … 100 psi abs.; 0 … 15 psi abs.; 0 … 150 psi abs.; 0 … 20 psi abs.; 0 … 200 psi abs.; 0 … 30 psi abs.; -15 … 130 psi |
| temperature ranges | -30 … 100 °C; -20 … 50 °C; -20 … 80 °C; -40 … 100 °C; -40 … 80 °C |
| accuracy or uncertainty | ≤ 0.2 % of span at reference conditions, 0.1 % with calibration |
| traceability | DAkkS |
| medium | gas, air, oil, water |
| portable | true |

## Datasheet tables

### Basic information

| Case | 2 | 3 |
|---|---|---|
| Material | Stainless steel |  |
| Dimensions | → See technical drawing |  |
| Weight | Approx. 220 g [0.49 lb] |  |
| Electrical connection | Bayonet connector, 7-pin |  |
| Sensor compatibility per plug-and-play |  |  |
| CPT6200 | ■ To CPH6200 ■ To CPH6300 | ■ Via 1.1 m[3.3 ft] sensor connection cable ■ Extension cable for connection of sensors Length: approx. 3.8 m[12.5 ft] to approx. 5 m[16.4 ft] |
| CPT62I0 | To CPH62I0 | ■ Via 1.1 m[3.3 ft] sensor connection cable ■ Extension cable for connection of sensors Length: approx. 3.8 m[12.5 ft] to approx. 5 m[16.4 ft] |
| Ingress protection | ■ IP65 ■ IP67 when connected Both ingress protection types | are met |

### Accuracy specifications

| Accuracy 1) | ■ ≤ 0.2 %of span at reference conditions ■ 0.1 %recommended, only in combination with a calibration of sensor and hand-held |
|---|---|
| Reference conditions |  |
| Ambient temperature | 15 ... 25 °C [59 ... 77 °F] |
| Mounting position | Vertical mounting position, process connection facing downwards |
| Compensated range | 0 ... 80 °C [0 ... 176 °F] |
| Mean temperature coefficient | ≤ 0.2 %of span/10 K (outside the reference conditions) |

### mbar

| 0 ... 100 | 0 ... 400 |
|---|---|
| 0 ... 160 | 0 ... 600 |
| 0 ... 250 | - |

| bar | 2 |
|---|---|
| 0 ... 1 | 0 ... 60 |
| 0 ... 1.6 | 0 ... 70 |
| 0 ... 2.5 | 0 ... 100 |
| 0 ... 4 | 0 ... 160 |
| 0 ... 6 | 0 ... 250 |
| 0 ... 10 | 0 ... 400 |
| 0 ... 16 | 0 ... 600 |
| 0 ... 25 | 0 ... 1,000 |
| 0 ... 40 | - |

| psi | 2 |
|---|---|
| 0 ... 5 | 0 ... 300 |
| 0 ... 10 | 0 ... 500 |
| 0 ... 15 | 0 ... 1,000 |
| 0 ... 20 | 0 ... 1,500 |
| 0 ... 30 | 0 ... 2,000 |
| 0 ... 50 | 0 ... 3,000 |
| 0 ... 100 | 0 ... 6,000 |
| 0 ... 150 | 0 ... 8,000 |
| 0 ... 200 | 0 ... 14,500 |

| bar abs. | 2 |
|---|---|
| 0 ... 0.25 | 0 ... 4 |
| 0 ... 0.4 | 0 ... 6 |
| 0 ... 0.6 | 0 ... 10 |
| 0 ... 1 | 0 ... 16 |
| 0 ... 1.2 | 0 ... 25 |
| 0 ... 1.6 | 0.8 ... 1.2 |
| 0 ... 2.5 | - |

| mbar | 2 |
|---|---|
| -600 ...+600 | -19.99 ...+40 |
| -400 ...+400 | -19.99 ...+60 |
| -250 ...+250 | -600 ... 0 |
| -100 ...+100 | -400 ... 0 |
| -19.99 ...+25 | -250 ... 0 |

| bar | 2 |
|---|---|
| -1 ... 0 | -1 ... 9 |
| -1 ... 1.5 | -1 ... 15 |
| -1 ... 3 | -1 ... 24 |
| -1 ... 5 | -1 ... 39 |

### Further details on: measuring range

| 1 | 2 | 3 |
|---|---|---|
| Overpressure limit |  |  |
| 3 times | < 25 bar | < 360 psi |
| 2 times | > 25 ...≤ 600 bar | > 360 ...≤ 8,700 psi |
| 1.5 times | > 600 ...≤ 1,000 bar | > 8,700 ...≤ 14,500 psi |

| Process connection | 2 | 3 |
|---|---|---|
| EN 837 | ■ G½B ■ G¼B | ≤ 1,000 bar [≤ 14,500 psi] |
|  | ■ G½Bflush with O-ring (NBR) ■ G½Bflush with O-ring (EPDM) | 1.6 ... 1,000 bar or bar abs. [20 ... 14,500 psi or psi abs.] |
|  | ■ G1Bflush with O-ring (NBR) ■ G1Bflush with O-ring (EPDM) | > 0.1 ...≤ 1.6 bar or bar abs. [> 5 ...≤ 20 psi or psi abs.] |
| ANSI/ASME B1.20.1 | ■ ½NPT ■ ¼NPT | ≤ 1,000 bar [≤ 14,500 psi] |

### psi abs.

| 0 ... 5 | 0 ... 50 |
|---|---|
| 0 ... 10 | 0 ... 100 |
| 0 ...15 | 0 ... 150 |
| 0 ... 20 | 0 ... 200 |
| 0 ... 30 | - |

### Further details on: process connection

| 1 | 2 | 3 |
|---|---|---|
| Process connection adapter 1) | ■ Without ■ G½to¼NPT ■ G½to½NPT |  |
| Seal | ■ NBR ■ EPDM ■ FKM/FPM |  |
| Other versions | Oil- and grease-free | Per G93:2019 level D (< 220 mg/m²) |
| Thread (only for CTP62I0) | M4 in pressure port, 5 mmdeep |  |
| → Others on request |  |  |
| Material |  |  |
| Wetted parts | -1 ... 1,000 bar [-14.5 ... 14,500 psi] | ■ Stainless steel 1.4404 (316L) ■ Elgiloy ® 2.4711 |
| > 40 bar ...≤ 1,000 bar [> 500 ...≤ 15,000 psi] | ■ Process connection: stainless steel 1.4404 (316L) ■ Sensor: Elgiloy ® 2.4711 |  |
| -1 ... 10,000 bar [-14.5 ... 150,000 psi] | ■ Stainless steel 1.4435 (316L) ■ Hastelloy ® 2.4819 (HC276) ■ Gold-plated |  |
| > 25 bar [360 psi] | ■ Stainless steel with O-ring from NBR ■ Elgiloy ® with O-ring from NBR |  |
| Flush design | ■ Stainless steel with O-ring from NBR ■ Stainless steel with O-ring from FKM/FPM ■ Stainless steel with O-ring from EPDM ■ Hastelloy C4 with O-ring from NBR ■ Hastelloy C4 with O-ring from FKM/FPM |  |
| Internal pressure transmission medium | Synthetic oil | ■ For measuring ranges to ≤ 16 bar [≤ 300 psi] ■ Flush diaphragm ■ Listed by FDA for food industry |

### Operating conditions

| 1 | 2 |
|---|---|
| Medium temperature range |  |
| CPT6200 | -30 ...+100 °C [-22 ...+212 °F] |
| CPT62I0 | -20 ...+50 °C [-4 ...+122 °F] |
| Operating temperature |  |
| CPT6200 | -20 ...+80 °C [-4 ...+176 °F] |
| CPT62I0 | -20 ...+50 °C [-4 ...+122 °F] |
| Storage temperature range |  |
| CPT6200 | -40 ...+100 °C [-40 ...+212 °F] |
| CPT62I0 | -40 ...+80 °C [-40 ...+176 °F] |
| Relative humidity, condensation | 0 ... 95 %relative humidity (non-condensing) |
| Ingress protection | ■ IP65 ■ IP67 when connected Both ingress protection types are met |
| Permissible pollution degree | 3 per EN 61010-1 |
| EMC (HF field) | EN 61326 emission (group 1, class B) and immunity (portable equipment) |

| Parameters | Power supply circuit CPT62I0 |
|---|---|
| Max. input voltage | U i = DC 10.4V |
| Max. input current | I i = 100mA |
| Max. input power | P i = 500mW |
| Max. internal capacitance | C i = 600 nF |
| Max. internal inductance | L i negligible |

| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity for CPT6200 European | Union |  |
| EMCdirective EN 61326 emission (group 1, class B) and immunity (portable equipment) |  |  |
| Pressure Equipment Directive PS > 200 bar; module A, pressure accessory |  |  |
| RoHS directive |  |  |
| EU declaration of conformity for CPT62I0 | European Union |  |
| EMCdirective EN 61326 emission (group 1, class B) and immunity (portable equipment) |  |  |
| Pressure Equipment Directive PS > 200 bar; module A, pressure accessory |  |  |
| RoHS directive |  |  |
| ATEX directive Hazardous areas - Ex i Zone 1 gas II 2G Ex ib IIC T4 Gb II 2G Ex ib IIC T4 |  |  |

### Description

| Calibration | ■ 3.1 inspection certificate per EN 10204 ■ DAkkS calibration certificate (traceable and accredited in accordance with ISO/IEC 17025) |
|---|---|
| Recommended calibration interval | 1 year (dependent on conditions of use) |

| 1 | 2 | 3 |
|---|---|---|
| For model CPT6200 to CPH6200 or CPH6300 | Order code |  |
| Description 1) | CPH-A-62- CPH-A-63- |  |
|  | Seal set Consisting of: ■ 4 x G½USIT seals ■ 2 x G¼USIT seals ■ Plastic box | -D- |
|  | Cable Sensor connection cable Length: approx. 1.1 m[3.3 ft] | -S- |
|  | Extension cable for connection of sensors Length: approx. 3.8 m[12.5 ft] to approx. 5 m[16.4 ft] | -V- |
| Ordering information for your enquiry: |  |  |
| 1. Order code: CPH-A-62- 2. Option: | ⇓ [ ] |  |

| 1 | 2 | 3 |
|---|---|---|
| For model CPT62I0 to CPH62I0 | Order code |  |
| Description 1) |  | CPH-A-6I- |
|  | Seal set Consisting of: ■ 4 x G½USIT seals ■ 2 x G¼USIT seals ■ Plastic box | -D- |
|  | Cable Sensor connection cable Length: approx. 1.1 m[3.3 ft] Ex version! Marked with blue ring. | -S- |
|  | Extension cable for connection of sensors Length: approx. 3.8 m[12.5 ft] to approx. 5 m[16.4 ft] | -V- |
| Ordering information for your enquiry: |  |  |
| 1. Order code: CPH-A-6I- 2. Option: | ⇓ [ ] |  |

## Documents

- [ds_ct1103_en_co_accea9](https://avigan.com.ua/wika/docs/wika/ds_ct1103_en_co.pdf) — PDF, 415 KB, en

## Configurator

This product has an interactive configurator on its product page.

```
CPT6200- -MGDSZ Z-ZZ
```