# حساس ضغط — A-10

> للاستخدامات الصناعية العامة

- رمز الكتالوج: a_10
- الطراز: A-10
- الفئة: قياس الضغط › Pressure sensors
- صفحة المنتج: https://avigan.com.ua/wika/ar/products/a_10
- السعر: 133.95 EUR
- المورد: AVIGAN (TOV VIKA Prylad)، الشريك الرسمي لشركة WIKA في أوكرانيا

## نظرة عامة

يقدم مُرسِل الضغط من الطراز A-10 جودة ممتازة بسعر تنافسي للغاية. يمكن أن ...

## التطبيقات

- Machine building
- Measurement and control technology
- Hydraulics and pneumatics
- Pumps and compressors
- Ship building

## المزايا

- Excellent quality and proven technology
- Exceptionally large variety covers almost all applications
- All configurable variants are available at short notice fromquantities of 1 upwards
- Particularly cost-efficient

## المواصفات الفنية

| المعيار | القيمة |
|---|---|
| model | A-10 |
| product family | A-10 |
| short description | Pressure transmitter for general industrial applications with configurable variants, multiple measuring ranges, and high reliability. |
| subcategory | Pressure transmitter |
| certifications | CE; RoHS; EAC; UL; NSF/ANSI/CAN 61; China RoHS |
| ambient temp | -40 … 100 °C |
| ip rating | IP65 |
| weight kg | 0.08 |
| languages in datasheet | en; de; es; fr |
| pressure ranges | 0 … 0.05 bar; 0 … 0.1 bar; 0 … 0.16 bar; 0 … 0.25 bar; 0 … 0.4 bar; 0 … 0.6 bar; 0 … 1 bar; 0 … 1.6 bar; 0 … 2.5 bar; 0 … 4 bar; 0 … 6 bar; 0 … 10 bar; 0 … 16 bar; 0 … 25 bar; 0 … 40 bar; 0 … 60 bar; 0 … 100 bar; 0 … 160 bar; 0 … 250 bar; 0 … 400 bar; 0 … 600 bar; 0 … 1000 bar; 0 … 1500 bar; 0 … 2000 bar; 0 … 3000 bar; 0 … 5000 bar; 0 … 10000 bar; 0 … 15000 bar; -0.05 … 0 bar; -0.05 … 0.05 bar; -0.05 … 0.15 bar; -0.05 … 0.2 bar; -0.05 … 0.25 bar; -0.1 … 0 bar; -0.1 … 0.1 bar; -0.15 … 0.15 bar; -0.16 … 0 bar; -0.2 … 0.2 bar; -0.25 … 0 bar; -10 … 10 inWC; -20 … 0 inWC; -20 … 20 inWC; -40 … 0 inWC; -40 … 40 inWC; -50 … 50 inWC; -60 … 0 inWC; -75 … 75 inWC; 0 … 0.1 bar abs.; 0 … 0.16 bar abs.; 0 … 0.25 bar abs.; 0 … 0.4 bar abs.; 0 … 0.6 bar abs.; 0 … 1 bar abs.; 0 … 1.6 bar abs.; 0 … 5 psi abs.; 0 … 15 psi abs.; 0 … 25 psi abs.; 0 … 30 psi abs.; 0 … 50 psi abs.; 0 … 40 inWC abs.; 0 … 60 inWC abs.; 0 … 80 inWC abs.; 0 … 100 inWC abs.; 0 … 120 inWC abs.; 0 … 20 inWC; 0 … 40 inWC; 0 … 60 inWC; 0 … 80 inWC; 0 … 100 inWC; 0 … 120 inWC; 0 … 150 inWC; 0 … 200 inWC; 0 … 250 inWC; 0 … 400 inWC; -0.025 … 0.025 bar; -80 … 0 inWC; -100 … 0 inWC; -100 … 100 inWC; -120 … 0 inWC; -125 … 125 inWC; -150 … 0 inWC; -200 … 200 inWC; -250 … 0 inWC; 0 … 2.5 bar abs.; 0 … 4 bar abs.; 0 … 6 bar abs.; 0 … 10 bar abs.; 0 … 16 bar abs.; 0 … 25 bar abs.; 0 … 100 psi abs.; 0 … 150 psi abs.; 0 … 200 psi abs.; 0 … 300 psi abs.; 0 … 150 inWC abs.; 0 … 200 inWC abs.; 0 … 250 inWC abs.; 0 … 400 inWC abs.; -0.25 … 0.25 bar; 0 … 2.5 inWC abs.; 0 … 4 inWC abs.; 0 … 6 inWC abs.; 0 … 10 inWC abs.; 0 … 16 inWC abs.; 0 … 25 inWC abs.; 0 … 1 psi; 0 … 5 psi; 0 … 15 psi; 0 … 25 psi; 0 … 30 psi; 0 … 50 psi; 0 … 100 psi; 0 … 160 psi; 0 … 200 psi; 0 … 300 psi; 0 … 500 psi; 0 … 1000 psi; 0 … 1500 psi; 0 … 2000 psi; 0 … 3000 psi; 0 … 5000 psi; 0 … 10000 psi; 0 … 15000 psi; -1 … 0 psi; -30 … 0 inHg; -30 … 15 inHg; -30 … 30 inHg; -30 … 60 inHg |
| accuracy class | ≤ ±0.25 % of span |
| accuracy standard | IEC 61298-2 |
| process connections | M14 x 1.5; M20 x 1.5; G 1/4 A; G 1/2 A; G 1/8; G 1/4; G 3/8; G 1/2; 7/16-20 UNF; G 1/8 B; G 1/4 B; G 1/4 female thread; G 3/8 B; G 1/2 B; 1/8 NPT; 1/4 NPT; 1/4 NPT, female thread; 1/2 NPT; R 1/4; R 3/8; R 1/2; PT 1/4; PT 1/2; PT 3/8; 7/16-20 UNF O-ring BOSS; Flange connection |
| case material | Stainless steel; Stainless steel 316L; PA and PBT; TPU and PUR |
| wetted parts material | Stainless steel; Stainless steel 316L; PH grade steel; Synthetic oil; Dry measuring cell |
| sealing material | NBR; FPM/FKM; EPDM; Copper; Stainless steel; HNBR |
| process temp | -40 … 100 °C |
| output signal | 4-20 mA; 0-10 V; 0-5 V; 1-5 V; 0.5-4.5 V ratiometric; 4-20mA; 0-10V; 0-5V; 1-5V; 0.5-4.5V |
| power supply | 10...30 V DC |
| electrical connection | M12 4-pin, cable gland PG7/PG9/PG11/PG13.5 |

## جداول ورقة البيانات

| Accuracy specifications | Non-linearity ≤ ±0.5 %of span | Non-linearity ≤ ±0.25 %of span |
|---|---|---|
| Non-linearity per BFSL per IEC 61298-2 |  |  |
| Measuring range ≤ 0.1 bar [≤ 1.45 psi] | ≤ ±0.5 %of span | - |
| Measuring range > 0.1 bar [> 1.45 psi] | ≤ ±0.5 %of span | ≤ ±0.25 %of span 1) |
| Accuracy | → See &#x27;Max. measured error per IEC 61298-2&#x27; |  |
| Max. measured error per IEC 61298-2 |  |  |
| Measuring range ≥ 0.6 bar [≥ 8.7 psi] | ≤ ±1 %of span | ≤ ±0.5 %of span |
| Measuring range ≥ 0.4 bar [≥ 5.8 psi] | ≤ ±1.2 %of span | ≤ ±0.7 %of span |
| Measuring range ≥ 0.25 bar [≥ 3.6 psi] | ≤ ±1.3 %of span | ≤ ±0.8 %of span |
| Measuring range ≥ 0.16 bar [≥ 2.3 psi] | ≤ ±1.5 %of span | ≤ ±1 %of span |
| Measuring range ≥ 0.1 bar [≥ 1.45 psi] | ≤ ±1.8 %of span | - |
| Measuring range ≥ 0.05 bar [≥ 0.73 psi] | ≤ ±2.4 %of span | - |
| Zero point error 2) 3) |  |  |
| 4 ... 20 mA/ DC 1 ...5V / DC 0.5 ...4.5V / DC 0.5 ...4.5V ratiometric | ≤ ±0.3 %of span | ≤ ±0.2 %of span |
| DC 0 ...10V | ≤ ±0.5 %of span | ≤ ±0.4 %of span |
| DC 0 ...5V 4) | ≤ ±0.6 %of span | - |

### Further details on: accuracy specifications

| 1 | 2 | 3 |
|---|---|---|
| Signal noise | ≤ 0.2 %of span |  |
| Non-repeatability per IEC 61298-2 |  |  |
| Measuring range < 0.1 bar [< 1.45 psi] | ≤ 0.2 %of span |  |
| Measuring range > 0.1 bar [> 1.45 psi] | ≤ 0.1 %of span |  |
| Temperature error at 0 ... 80 °C [32 ... 176 °F] |  |  |
| - | Typical | ≤ ±1 %of span |
| Measuring range < 1 bar [< 14.5 psi] | Maximum | ≤ ±2.5 %of span |
| Measuring range ≥ 1 bar [≥ 14.5 psi] | Maximum | ≤ ±1.5 %of span |
| Measuring range ≥ 10 bar [≥ 145 psi] | Maximum | ≤ ±2 %of span |
| Measuring range > 25 bar [> 360 psi] | Maximum | ≤ ±1.5 %of span |
| Temperature hysteresis -30 ... +100°C [-22 ... +212 °F] for measuring ranges < 0.6 bar [< 8.7 psi] |  |  |
| Measuring range < 0.6 bar [< 8.7 psi] | Gauge pressure | ≤ 0.2 %of span |
| Absolute pressure | ≤ 0.2 %of span |  |
| Measuring range < 0.4 bar [< 5.8 psi] | Gauge pressure | ≤ 0.3 %of span |
| Absolute pressure | ≤ 0.3 %of span |  |
| Measuring range < 0.25 bar [< 3.6 psi] | Gauge pressure | ≤ 0.5 %of span |
| Absolute pressure | ≤ 0.5 %of span |  |
| Measuring range < 0.16 bar [< 2.3 psi] | Gauge pressure | ≤ 0.7 %of span |
| Absolute pressure | ≤ 0.8 %of span |  |
| Measuring range < 0.1 bar [< 1.45 psi] | Gauge pressure | ≤ 1.4 %of span |

### Further details on: accuracy specifications

| Long-term drift per IEC 61298-2 | 2 |
|---|---|
| Measuring range ≤ 0.1 bar [≤ 1.45 psi] | ≤ ±0.5 %of span 1) |
| Measuring range ≤ 0.4 bar [≤ 5.8 psi] | ≤ ±0.2 %of span |
| Measuring range > 0.4 bar [> 5.8 psi] | ≤ ±0.1 %of span |
| Additional zero point error depending on the mounting position for measuring ranges ≤ 1 bar [≤ 15 psi] |  |
| Mounting position 180°, vertical, top process connection | ≤ 1 mbar [≤ 0.015 psi] |
| Mounting position 90°, horizontal | ≤ 0.6 mbar [≤ 0.009 psi] |
| Reference conditions | Per IEC 61298-1 |

| bar | 2 |
|---|---|
| 0 ... 0.05 | 0 ... 10 1) |
| 0 ... 0.1 | 0 ... 16 1) |
| 0 ... 0.16 | 0 ... 25 1) |
| 0 ... 0.25 | 0 ... 40 |
| 0 ... 0.4 | 0 ... 60 |
| 0 ... 0.6 | 0 ... 100 |
| 0 ... 1 | 0 ... 160 |
| 0 ... 1.6 | 0 ... 250 |
| 0 ... 2.5 | 0 ... 400 |
| 0 ... 4 | 0 ... 600 |
| 0 ... 6 | 0 ... 1,000 |

### psi

| 0 ... 1 | 0 ... 300 1) |
|---|---|
| 0 ... 5 | 0 ... 500 |
| 0 ... 15 | 0 ... 1,000 |
| 0 ... 25 | 0 ... 1,500 |
| 0 ... 30 | 0 ... 2,000 |
| 0 ... 50 | 0 ... 3,000 |
| 0 ... 100 | 0 ... 5,000 |
| 0 ... 160 1) | 0 ... 10,000 |
| 0 ... 200 1) | 0 ... 15,000 |

| inWC | 2 |
|---|---|
| 0 ... 20 | 0 ... 120 |
| 0 ... 40 | 0 ... 150 |
| 0 ... 60 | 0 ... 200 |
| 0 ... 80 | 0 ... 250 |
| 0 ... 100 | 0 ... 400 |

### bar abs.

| 0 ... 0.1 | 0 ... 2.5 |
|---|---|
| 0 ... 0.16 | 0 ... 4 |
| 0 ... 0.25 | 0 ... 6 |
| 0 ... 0.4 | 0 ... 10 |
| 0 ... 0.6 | 0 ... 16 |
| 0 ... 1 | 0 ... 25 |
| 0 ... 1.6 | - |

### psi abs.

| 0 ... 5 | 0 ... 100 |
|---|---|
| 0 ... 15 | 0 ... 150 |
| 0 ... 25 | 0 ... 200 |
| 0 ... 30 | 0 ... 300 |
| 0 ... 50 | - |

### inWC abs.

| 0 ... 40 | 0 ... 150 |
|---|---|
| 0 ... 60 | 0 ... 200 |
| 0 ... 80 | 0 ... 250 |
| 0 ... 100 | 0 ... 400 |
| 0 ... 120 | - |

| bar | 2 |
|---|---|
| -0.025 ... +0.025 | -0.3 ... +0.3 |
| -0.05 ... 0 | -0.4 ... 0 |
| -0.05 ... +0.05 | -0.5 ... +0.5 |
| -0.05 ... +0.15 | -0.6 ... 0 |
| -0.05 ... +0.2 | -1 ... 0 |
| -0.05 ... +0.25 | -1 ... +0.6 |
| -0.1 ... 0 | -1 ... +1.5 |
| -0.1 ... +0.1 | -1 ...+3 |
| -0.15 ... +0.15 | -1 ...+5 |
| -0.16 ... 0 | -1 ...+9 1) |
| -0.2 ... +0.2 | -1 ...+15 1) |
| -0.25 ... 0 | -1 ...+24 1) |

### inWC

| -10 ...+10 | -80 ... 0 |
|---|---|
| -20 ... 0 | -100 ... 0 |
| -20 ...+20 | -100 ...+100 |
| -40 ... 0 | -120 ... 0 |
| -40 ...+40 | -125 ...+125 |
| -50 ...+50 | -150 ... 0 |
| -60 ... 0 | -200 ...+200 |
| -75 ...+75 | -250 ... 0 |

### Further details on: measuring range

| 1 | 2 | 3 |
|---|---|---|
| Units | ■ bar ■ psi ■ inWC ■ mbar ■ kg/cm² ■ MPa |  |
| Maximum working pressure | → Corresponds to the upper measuring range value / measuring range full scale value → Any permanent operation above the maximum working pressure is not permis - sible |  |
| Overpressure limit | The overpressure limit is based on the measuring range. Depending on the select - ed process connection and the seal, restrictions in overpressure limit can result. |  |
| bar | Measuring ranges ≤ 0.1 bar | 0.2 bar |
| Measuring ranges ≤ 0.4 bar | 1 bar |  |
| Measuring ranges < 1.6 bar | 3 bar |  |
| Measuring ranges ≥ 1.6 bar | 2 times |  |
| Measuring range 1,000 bar | 1.43 times |  |
| bar abs. | Measuring ranges ≤ 0.4 bar abs. | 1 bar abs. |
| Measuring ranges < 1.6 bar abs. | 3 bar abs. |  |
| Measuring ranges ≥ 1.6 bar abs. | 2 times |  |
| psi | Measuring ranges ≤ 1 psi | 3 psi |
| Measuring ranges ≤ 5 psi | 14.5 psi |  |
| Measuring ranges < 25 psi | 45 psi |  |
| Measuring ranges ≥ 25 psi | 2 times |  |
| Measuring ranges 160 psi, 1,000 psi, 1,500 psi and 10,000 psi | 1.7 times |  |
| Measuring range 15,000 psi | 1.43 times |  |
| psi abs. | Measuring ranges ≤ 5 psi abs. | 14.5 psi abs. |
| Measuring ranges < 25 psi abs. | 45 psi abs. |  |
| Measuring ranges ≥ 25 psi abs. | 2 times |  |

### Further details on: measuring range

| inWC | Measuring ranges ≤ 40 inWC | 80 inWC |
|---|---|---|
|  | Measuring ranges ≤ 200 inWC | 400 inWC |
|  | Measuring ranges ≤ 400 inWC | 1,200 inWC |
| inWC abs. | Measuring ranges ≤ 200 inWC abs. | 400 inWC abs. |
|  | Measuring ranges ≤ 400 inWC abs. | 1,200 inWC abs. |
| Vacuum resistance | Yes (restriction with measuring ranges ≤ 0.1 bar [≤ 1 psi, 40 inWC]: -0.2 bar [-3 psi, -80 |  |
| Leakage rate | ■ < 5*10 -3 mbar*l/s ■ < 1*10 -6 mbar*l/s 1) 2) |  |

### Process connection

| Standard | Thread size | Max. measuring range | Overpressure limit | Seal |
|---|---|---|---|---|
| EN 837 | G⅛B | 400 bar [5,000 psi] | 572 bar [8,290 psi] | Copper |
| G¼B | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] | ■ Copper ■ Stainless steel |  |
| G¼female thread | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] | Without |  |
| G⅜B | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] | ■ Copper ■ Stainless steel |  |
| G½B | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] | ■ Copper ■ Stainless steel |  |
| DIN EN ISO 1179-2 | G¼A | 600 bar [8,000 psi] | 858 bar [12,440 psi] | ■ NBR ■ EPDM |
| 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] | FPM/FKM |  |  |
| G½A | 600 bar [8,000 psi] | 858 bar [12,440 psi] | ■ NBR ■ FPM/FKM |  |
| DIN EN ISO 9974-2 | M14 x 1.5 | 600 bar [8,000 psi] | 858 bar [12,440 psi] | ■ NBR ■ FPM/FKM ■ EPDM |
| ANSI/ASME B1.20.1 | ⅛NPT | 400 bar [5,000 psi] | 572 bar [8,290 psi] | - |
| ¼NPT | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] |  |  |
| ¼NPT, female thread | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] |  |  |
| ½NPT | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] |  |  |
| DIN 16288 | M20 x 1.5 | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] | ■ Copper ■ Stainless steel |
| ISO 7 | R¼ | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] | - |
| R⅜ | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] |  |  |
| R½ | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] |  |  |
| KS | PT¼ | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] | - |
| PT½ | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] |  |  |
| PT⅜ | 1,000 bar [15,000 psi] | 1,480 bar [21,400 psi] |  |  |
| SAE J514 | 7/16-20 UNF O-ring BOSS | 600 bar [8,000 psi] | 858 bar [12,440 psi] | FPM/FKM |
| - | Flange connection | 100 bar [1,000 psi] | 143 bar [2,070 psi] | Without |

| Output signal | 2 | 3 |
|---|---|---|
| Signal type |  |  |
| Current (2-wire) | 4 ...20mA |  |
| Voltage (3-wire) | ■ DC 0 ...10V ■ DC 0 ...5V ■ DC 1 ...5V ■ DC 0.5 ...4.5V |  |
| Ratiometric (3-wire) | DC 0.5 ...4.5V |  |
| Load Ω |  |  |
| Current (2-wire) | ≤ (auxiliary power - 8 V) / 0.02 A |  |
| Voltage (3-wire) | > Maximum output signal /1mA |  |
| Ratiometric (3-wire) | > 10k |  |
| Voltage supply |  |  |
| Auxiliary power | Output signal 4 ...20mA | ■ DC 8 ...30V ■ DC 8 ...35V 1) 2) |
|  | Output signal DC 0 ...5V 1) 3) | ■ DC 8 ...30V ■ DC 8 ...35V |
|  | Output signal DC 1 ...5V | ■ DC 8 ...30V ■ DC 8 ...35V |
|  | Output signal DC 0.5 ...4.5V | ■ DC 8 ...30V ■ DC 8 ...35V |
|  | Output signal DC 0 ...10V | ■ DC 14 ...30V ■ DC 14 ...35V |
|  | Output signal DC 0.5 ... 4.5 V, ratiometric | DC 5V ±10% |
| Current supply | Current (2-wire) | Signal current, max.25mA |
|  | Voltage (3-wire) | 8mA |
|  | Ratiometric (3-wire) | 8mA |

### Output signal

| 1 | 2 | 3 |
|---|---|---|
| Dynamic behaviour |  |  |
| Settling time per IEC 61298-2 | Measuring range ≥ 0.4 bar [≥ 5.8 psi] | < 1 ms ⁴⁾ |
|  | Measuring range < 0.4 bar [< 5.8 psi] | < 1 min |
| Switch-on time | Measuring range ≥ 0.4 bar [≥ 5.8 psi] | < 15 ms |
|  | Measuring range < 0.4 bar [< 5.8 psi] | < 1 min |

### Electrical connection

| Connection type | IP code 1) | Wire cross-section | Cable diameter | Cable material |
|---|---|---|---|---|
| Angular connector DIN EN 175301-803 A |  |  |  |  |
| With mating connector, PG9 (stand - ard) | IP65 | To max. 1.5 mm² | 6 ...8mm | - |
| With mating connector, PG11 | IP65 | To max. 1.5 mm² | 8 ...10mm |  |
| With mating connector, PG13.5 2) | IP65 | To max. 1.5 mm² | 10 ...14mm |  |
| With moulded cable 3) | IP65 | 3 x 0.75 mm² | 6mm | PUR |
| Angular connector DIN EN 175301-803 C 3) |  |  |  |  |
| With mating connector | IP65 | To max. 0.75 mm² | 4.5 ...6mm | - |
| Circular connector M12 x 1 (4-pin) |  |  |  |  |
| Without mating connector | IP67 | - | - | - |
| Straight with moulded cable 3) | IP67 | 3 x 0.34 mm² | 4.3mm | PUR |
| Angled with moulded cable 3) | IP67 | 3 x 0.34 mm² | 4.3mm | PUR |
| Cable outlet |  |  |  |  |
| Unshielded 3) | IP67 | 3 x 0.34 mm² | 4mm | PUR |
| OEMversion, unshielded 4) | IP67 | 3 x 0.14 mm² | 2.85mm | TPU |

### Further details on: electrical connection

| Connection type | → See table &#x27;Electrical connection&#x27; on page 7 |
|---|---|
| Wire cross-section | → See table &#x27;Electrical connection&#x27; on page 7 |
| Cable diameter | → See table &#x27;Electrical connection&#x27; on page 7 |
| Pin assignment | → See table &#x27;Pin assignment&#x27; |
| Ingress protection (IP code) per IEC 60529 | → See table &#x27;Electrical connection&#x27; on page 7 |
| Short-circuit resistance | S+ vs. U- |
| Reverse polarity protection | U+ vs. U- No reverse polarity protection with ratiometric output signal |
| Insulation voltage | DC 500V |

### Angular connector DIN 175301-803 A

| 1 | 2 | 2-wire | 3-wire |
|---|---|---|---|
|  | U + | 1 | 1 |
|  | U- | 2 | 2 |
|  | S+ | - | 3 |

| 1 | 2 | 2-wire | 3-wire |
|---|---|---|---|
| 1 2 3 | U + | 1 | 1 |
|  | U- | 2 | 2 |
|  | S+ | - | 3 |

## المستندات

- [ds_pe8160_en_co_26f373](https://avigan.com.ua/wika/docs/wika/ds_pe8160_en_co.pdf) — PDF, 926 KB, en

## المُهيِّئ

يتوفر لهذا المنتج مُهيِّئ تفاعلي في صفحة المنتج.

```
A-10- - - - - -ZW
```