SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

SITRANS FUE950 energy calculator — accessories and spare parts catalogue page

Вид документаКаталожна сторінка
ВиробникSIEMENS
МоделіSITRANS FUE950, DE-06-MI004-PTB011
Група обладнанняflow
Мова документаанглійська
Розмір файлу0.3 МБ

Про документ

The SITRANS FUE950 is an energy calculator for ultrasonic inline flowmeter systems (used with FUS380/FUE380 and MAG 5000/6000). This page is a catalogue of accessories, add-on modules, power supplies, temperature sensor pairs and spare parts for the FUE950, with order numbers.

Ключові дані

Temperature sensorPt500, 4-wire, 6 mm sensor diameter
Sensor lengths140 mm and 230 mm
Connection cable length5 m (4-wire types); 2/3/5/10 m (2-wire types)
MID approvalDE-06-MI004-PTB011
PTB approval22.77/09.01
Sensor pocketsG½B, PN 16 / PN 25 / max. PN 40

Застосування

  • Energy calculation in combination with SITRANS FUS380/FUE380 ultrasonic flowmeters or MAG 5000/6000 electromagnetic flowmeters
  • Data acquisition and programming via infrared optical head (Bluetooth type) or RS 232 cable

Особливості

  • MID approved and PTB approved Pt500 sensor pairs (approvals valid only when used with applicable temperature sensor pockets)
  • Add-on modules for 7ME348 versions: pulse input/output, RS 232/RS 485 (M-Bus), M-Bus, combined current output 2 x passive 4 … 20 mA
  • Power options: 3.6 V D-cell battery, 230 V AC supply module (incl. internal fuse T50 mA L 250 V and back-up battery), 24 V AC supply module with back-up battery
  • Programming software tools: basic version free download from internet; expert and Test Lab versions available

Технічні дані

Parameter Value
Pt500 sensor pair, 4-wire, 6 mm diameter, 140 mm length Order No. A5E03462872
Pt500 sensor pair, 4-wire, 6 mm diameter, 230 mm length Order No. A5E03462878
MID approval (sensor pairs) DE-06-MI004-PTB011
PTB approval (sensor pairs) 22.77/09.01
Connection cable, 4-wire sensor pairs 5 m
Infrared optical head (Bluetooth type) Order No. A5E02611768
Bracket for wall mounting (20 pcs.) Order No. A5E02611769
Cable for data acquisition via RS 232 PC/D-sub 9F/3 wire Order No. A5E02611774
Pulse input module (2 inputs) Order No. A5E03461432
Pulse output module (2 outputs) Order No. A5E03461436
Combined pulse in-/output module (2 inputs and 1 output) Order No. A5E03461437
RS 232 module (M-Bus protocol) Order No. A5E03461459
RS 485 module (M-Bus protocol) Order No. A5E03461512
M-Bus module Order No. A5E03461516
Combined current output module, 2 x passive 4 … 20 mA Order No. A5E03461583
Connection cable for option modules (special connection cable with 2 plugs) Order No. A5E03461585
3.6 V D-cell battery Order No. A5E03461708
230 V AC supply module (incl. internal fuse T50 mA L 250 V and back-up battery) Order No. A5E03461717
24 V AC supply module incl. back-up battery Order No. A5E03461719
Expert version programming software tool Order No. A5E03478951
Test Lab. version re-programming software tool Order No. A5E03461778
Bottom part of FUE950 enclosure (1 pc.) Order No. A5E03461508
Snap fit for FUE950 enclosure (1 pc.) Order No. A5E30461731
Brass pocket 6 mm, G½B x 40 mm (PN 16), 1 pc. Order No. A5E02611778
Brass pocket 6 mm, G½B x 85 mm (PN 16), 1 pc. Order No. A5E02611779
Brass pocket 6 mm, G½B x 120 mm (PN 16), 1 pc. Order No. A5E02611780
Stainless steel pocket 6 mm, G½B x 85 mm (PN 25), 1 pc. Order No. A5E02611781
Stainless steel pocket 6 mm, G½B x 120 mm (PN 25), 1 pc. Order No. A5E02611783
Stainless steel pocket 6 mm, G½B x 155 mm (PN 25), 1 pc. Order No. A5E02611792
Stainless steel pocket 6 mm, G½B x 210 mm (PN 25), 1 pc. Order No. A5E02611793
Pt500 temperature sensor pair, 2-wire, cable 2 m Order No. A5E02611794
Pt500 temperature sensor pair, 2-wire, cable 3 m Order No. A5E02611795
Pt500 temperature sensor pair, 2-wire, cable 5 m Order No. A5E02611796
Pt500 temperature sensor pair, 2-wire, cable 10 m Order No. A5E02611798
Stainless steel pocket (1 pc.), 135 mm length, max. PN 40 and max. 5 m/s (recommended for 140 mm sensor length) Order No. A5E03462868
Stainless steel pocket (1 pc.), 225 mm length, max. PN 40 and max. 5 m/s (recommended for 230 mm sensor length) Order No. A5E03462870

Варіанти замовлення

Temperature sensors must be connected to terminals 5 (1) and 6 (2) (TH) and 7 (3) and 8 (4) (TC). Note: the right flowmeter pulse output value must equal the FUE950 pulse input value and must be checked via the user menu of the transmitter MAG 5000/6000 or nameplate of FUE380 or FUS380.

Допуски та стандарти

  • MID approved DE-06-MI004-PTB011 (Pt500 4-wire sensor pairs; valid only if temp. sensors are used with the applicable temperature sensor pockets)
  • PTB approved 22.77/09.01

Текст документа

                                                                  © Siemens AG 2012

                                                                                                    Flow Measurement
                                                                                                             SITRANS F US Inline
                                                                                                SITRANS FUE950 energy calculator

■ Flowmeter SITRANS FUE950 operating instructions,                          Description                                          Order No.
  accessories and spare parts                                               Pt500 4-wire temperature sensor pair, with MID
                                                                            MI004 and PTB K7.2 approvals and verification (for
  Operating instructions                                                    related 4-wire sensor pocket types only)
   Description                        Order No.                             Pt500 sensor pair (6/140 mm), 4-wire with 5 m con-     A5E03462872
                                                                            nection cable, 6 mm sensor diameter and 140 mm
   • English                          A5E03424739
                                                                            sensor length. MID approved DE-06-MI004-PTB011,
  This device is shipped with a Quick Start guide and a CD con-             PTB approved 22.77/09.01 (mentioned approvals are
                                                                            only valid if temp. sensors are used with the applica-
  taining further SITRANS F US literature.                                  ble temperature sensor pockets).
  All literature is also available for free at:                             PT500 sensor pair (6/230 mm), 4-wire with 5 m con-     A5E03462878
  http://www.siemens.com/flowdocumentation                                  nection cable, 6 mm sensor diameter and 230 mm
  Accessories
                                                                            sensor length. MID approved DE-06-MI004-PTB011,
                                                                            PTB approved 22.77/09.01 (mentioned approvals are                    3
   Description                                             Order No.        only valid if temp. sensors are used with the applica-
                                                                            ble temperature sensor pockets).
   Infrared optical head (Bluetooth type) for data         A5E02611768
   acquisition & programming of FUE950                                      FUE950 enclosure (only for 7ME348 versions)

   Bracket for SITRANS FUE950 wall mounting (20 pcs.) A5E02611769           Bottom part of FUE950 enclosure (1 pc.)              A5E03461508

   Cable for data acquisition via RS 232 PC/D-sub          A5E02611774      Snap fit for FUE950 enclosure (1 pc.)                A5E30461731
   9F/3 wire                                                                Pocket for Pt500 temperature sensors (for corres-
   Basic version of programming software tool for FUE950 free download      ponding 2-wire Pt500 types only, 1pc.)
                                                         from internet      Brass pocket 6 mm, G½B x 40 mm (PN 16), 1 pc.        A5E02611778
   Expert version of programming software tool for         A5E03478951      Brass pocket 6 mm, G½B x 85 mm (PN 16), 1 pc.        A5E02611779
   FUE950
                                                                            Brass pocket 6 mm, G½B x 120 mm (PN 16), 1 pc.       A5E02611780
   Test Lab. version of re-programming software tool for   A5E03461778
   FUE950                                                                   Stainless steel 6 mm, G½B x 85 mm (PN 25), 1 pc.     A5E02611781
                                                                            Stainless steel 6 mm, G½B x 120 mm (PN 25), 1 pc.    A5E02611783
                                                                            Stainless steel 6 mm, G½B x 155 mm (PN 25), 1 pc.    A5E02611792
  Spare parts
                                                                            Stainless steel 6 mm, G½B x 210 mm (PN 25), 1 pc.    A5E02611793
   Description                                             Order No.
                                                                            Pt500 temperature sensor pair, 2-wire cable, 6 mm
   Add-on modules for FUE950 (only for 7ME348 ver-                          sensor diameter, with MID/EN-approval (for corres-
   sions)                                                                   sponding 2-wire sensor pocket types only)
   Pulse input module (2 inputs)                           A5E03461432      Cable length:
   Pulse output module (2 outputs)                         A5E03461436      2m                                                   A5E02611794
   Combined pulse in-/output module (2 inputs and          A5E03461437      3m                                                   A5E02611795
   1 output)
                                                                            5m                                                   A5E02611796
   RS 232 module (M-Bus protocol)                          A5E03461459
                                                                            10 m                                                 A5E02611798
   RS 485 module (M-Bus protocol)                          A5E03461512
   M-Bus module                                            A5E03461516
   Combined current output module, 2 x passive             A5E03461583
                                                                         ■ Schematics
   4 ... 20 mA                                                              Electrical connection for SITRANS FUS380/FUE380/FUE950
   Connection cable for option modules (types: Pulse,      A5E03461585      and MAG 5000/6000/FUE950
   RS 232/RS 485, M-Bus, mA) (special connection
   cable with 2 plugs)
   Power supply for FUE950 (only for 7ME348 ver-
   sions)
   3.6 V D-cell battery for SITRANS FUE950                 A5E03461708
   230 V AC supply module (incl. internal fuse T50 mA L A5E03461717
   250 V and back-up battery) for SITRANS FUE950
   24 V AC supply module for SITRANS FUE950, incl.         A5E03461719
   back-up battery                                                           56 +
                                                                             57 -
   Pocket for temperature sensors Pt500 (for related
   4-wire Pt500 type only, 1 pc.)
   Stainless steel pocket (1 pc.), 135 mm length for       A5E03462868
   6 mm sensor diameter, max. PN 40 and max. 5 m/s                          The diagram shows the connection between SITRANS FUE950 (terminals
   (recommended for 140 mm sensor length).                                  10 and 11) and FUS380/FUE380 and MAG 5000/6000 (terminals 56 and
   Stainless steel pocket (1 pc.), 225 mm length for       A5E03462870      57). Temperature sensors must be connected to terminals 5 (1) and
   6 mm sensor diameter, max. PN 40 and max. 5 m/s                          6 (2) (TH) and 7 (3) and 8 (4) (TC).
   (recommended for 230 mm sensor length).                                  Note:
                                                                            The right flowmeter pulse output value must be equal to the
                                                                            FUE950 pulse input value and must be checked via the user
                                                                            menu of the transmitter MAG 5000/6000 or nameplate of FUE380
                                                                            or FUS380.




                                                                                                                Siemens FI 01 · 2013    3/317


Документ виробника, опублікований як довідковий матеріал на обладнання, яке ми постачаємо. Правовласник може попросити прибрати його — приберемо.