SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

Технічний документ SIEMENS — Analyze MyWorkpiece /Monitor

Вид документаТехнічний документ
ВиробникSIEMENS
Код документаSINUMERIK-SINUMERIK-Edge
Сторінок104
Мова документаанглійська
Розмір файлу3.1 МБ

Текст документа

Introduction                 1
                                           Fundamental safety
                                           instructions                 2

                                           Overview                     3
SINUMERIK
                                           Import Capture Data          4
SINUMERIK Edge
Analyze MyWorkpiece /Monitor               Create Training Data Unit
                                           Sets                         5

                                           Train Models                 6
Operating Manual

                                           Manage Monitoring Jobs       7

                                           Analyze Monitoring Results   8

                                           User-defined algorithm       9

                                           Direct Monitoring            10

                                           Measurement cycle            11

Valid for control:
SINUMERIK ONE
SINUMERIK 840D sl / 840DE sl

Valid for software:
Analyze MyWorkpiece /Monitor Version 3.2

09/2022
A5E47919940B AE
Legal information
Warning notice system
             This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage
             to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices
             referring only to property damage have no safety alert symbol. These notices shown below are graded according to
             the degree of danger.

                    DANGER
             indicates that death or severe personal injury will result if proper precautions are not taken.

                    WARNING
             indicates that death or severe personal injury may result if proper precautions are not taken.

                    CAUTION
             indicates that minor personal injury can result if proper precautions are not taken.

             NOTICE
             indicates that property damage can result if proper precautions are not taken.
             If more than one degree of danger is present, the warning notice representing the highest degree of danger will be
             used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property
             damage.
Qualified Personnel
             The product/system described in this documentation may be operated only by personnel qualified for the specific
             task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
             Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
             avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
             Note the following:

                    WARNING
             Siemens products may only be used for the applications described in the catalog and in the relevant technical
             documentation. If products and components from other manufacturers are used, these must be recommended or
             approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance
             are required to ensure that the products operate safely and without any problems. The permissible ambient
             conditions must be complied with. The information in the relevant documentation must be observed.

Trademarks
             All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may
             be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
             We have reviewed the contents of this publication to ensure consistency with the hardware and software described.
             Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this
             publication is reviewed regularly and any necessary corrections are included in subsequent editions.

             Siemens AG                             A5E47919940B AE                                        Copyright © Siemens AG 2019 - 2022.
             Digital Industries                     Ⓟ 09/2022 Subject to change                            All rights reserved
             Postfach 48 48
             90026 NÜRNBERG
             GERMANY
Table of contents

1      Introduction ........................................................................................................................................... 7
       1.1               About SINUMERIK ................................................................................................................ 7
       1.2               About this documentation ................................................................................................... 7
       1.3               Documentation on the internet ............................................................................................ 8
       1.3.1             Documentation overview SINUMERIK ONE ........................................................................... 8
       1.3.2             Documentation overview SINUMERIK 840D sl....................................................................... 9
       1.4               Feedback on the technical documentation ........................................................................... 9
       1.5               mySupport documentation .................................................................................................. 9
       1.6               Service and Support........................................................................................................... 10
       1.7               OpenSSL ............................................................................................................................ 12
       1.8               General Data Protection Regulation .................................................................................... 12
2      Fundamental safety instructions......................................................................................................... 13
       2.1               General safety instructions................................................................................................. 13
       2.2               Warranty and liability for application examples ................................................................... 13
       2.3               Security information .......................................................................................................... 13
3      Overview.............................................................................................................................................. 15
       3.1               System description............................................................................................................. 15
       3.2               Users and rights ................................................................................................................. 17
       3.3               Starting Analyze MyWorkpiece /Monitor ............................................................................. 18
       3.4               Change password .............................................................................................................. 19
       3.5               Switch language ................................................................................................................ 20
       3.6               Sign out............................................................................................................................. 20
       3.7               Filtering data ..................................................................................................................... 20
       3.8               Managing memory space................................................................................................... 22
       3.9               Managing MQTT service .................................................................................................... 23
4      Import Capture Data ............................................................................................................................ 27
       4.1               Overview ........................................................................................................................... 27
       4.2               Importing records of a Capture job ..................................................................................... 29
       4.3               Deleting the record of a Capture job ................................................................................... 31
       4.4               Determining why an import was not successful .................................................................. 31
5      Create Training Data Unit Sets............................................................................................................. 33
       5.1               Overview ........................................................................................................................... 33

Analyze MyWorkpiece /Monitor
Operating Manual, 09/2022, A5E47919940B AE                                                                                                                     3
Table of contents

      5.2               Displaying details ............................................................................................................... 35
      5.3               Creating/configuring training data sets ............................................................................... 36
      5.4               Selecting records of a Capture job ...................................................................................... 40
      5.5               Creating training data sets ................................................................................................. 41
      5.6               Copy training data sets....................................................................................................... 42
      5.7               Deleting a training data set ................................................................................................ 43
6     Train Models ........................................................................................................................................ 45
      6.1               Overview ........................................................................................................................... 45
      6.2               Creating/configuring a model ............................................................................................. 47
      6.3               Selecting TDUs................................................................................................................... 50
      6.4               Training the model............................................................................................................. 51
      6.5               Validating models .............................................................................................................. 52
      6.6               Copying a model................................................................................................................ 53
      6.7               Deleting a model ............................................................................................................... 54
      6.8               Exporting and importing models ........................................................................................ 56
      6.9               Visual representation of models ......................................................................................... 56
7     Manage Monitoring Jobs ..................................................................................................................... 59
      7.1               Overview ........................................................................................................................... 59
      7.2               Creating/configuring jobs ................................................................................................... 61
      7.3               Copying jobs...................................................................................................................... 65
      7.4               Deleting jobs ..................................................................................................................... 66
      7.5               Archiving and reviving jobs ................................................................................................ 66
8     Analyze Monitoring Results ................................................................................................................. 69
      8.1               Overview ........................................................................................................................... 69
      8.2               Downloading or deleting several jobs ................................................................................. 72
      8.3               Download reports via REST API ........................................................................................... 75
      8.4               Downloading reports via MQTT notification ........................................................................ 77
9     User-defined algorithm........................................................................................................................ 79
      9.1               Overview ........................................................................................................................... 79
      9.2               Script Manager .................................................................................................................. 79
      9.2.1             Overview ........................................................................................................................... 79
      9.2.2             Script Package uploader ..................................................................................................... 81
      9.2.3             Validating the script packages ............................................................................................ 82
      9.2.4             Deleting script packages..................................................................................................... 83
      9.3               Creating/configuring jobs with user-defined algorithm ........................................................ 83
      9.4               Managing jobs with the user-defined algorithm .................................................................. 87

                                                                                                                      Analyze MyWorkpiece /Monitor
4                                                                                                      Operating Manual, 09/2022, A5E47919940B AE
                                                                                                                                         Table of contents

       9.5               Downloading reports ......................................................................................................... 88
       9.6               Example of MQTT messages............................................................................................... 88
10     Direct Monitoring ................................................................................................................................ 89
       10.1              Overview ........................................................................................................................... 89
       10.2              Creating/configuring jobs with Direct Monitoring ................................................................ 89
       10.3              Activating and connecting jobs with Direct Monitoring ....................................................... 92
       10.4              Managing jobs with Direct Monitoring................................................................................ 95
11     Measurement cycle.............................................................................................................................. 97
       11.1              Overview ........................................................................................................................... 97
       11.2              Creating/configuring jobs with a measurement cycle .......................................................... 97
       11.3              Managing jobs with measurement cycle........................................................................... 100
       11.4              Downloading reports ....................................................................................................... 100
       11.5              Example of MQTT messages............................................................................................. 101
       Index .................................................................................................................................................. 103

Analyze MyWorkpiece /Monitor
Operating Manual, 09/2022, A5E47919940B AE                                                                                                                       5
Table of contents

                                   Analyze MyWorkpiece /Monitor
6                   Operating Manual, 09/2022, A5E47919940B AE
Introduction                                                                                                    1
1.1              About SINUMERIK
                     From simple, standardized CNC machines to premium modular machine designs – the
                     SINUMERIK CNCs offer the right solution for all machine concepts. Whether for individual parts
                     or mass production, simple or complex workpieces – SINUMERIK is the highly dynamic
                     automation solution, integrated for all areas of production. From prototype construction and
                     tool design to mold making, all the way to large-scale series production.
                     Visit our website for more information SINUMERIK (https://www.siemens.com/sinumerik).

1.2              About this documentation

Overview
                     This document describes how you operate Analyze MyWorkpiece /Monitor.

Target group
                     The operating manual addresses all machine tool users. This publication provides information
                     required by the user to understand the Analyze MyWorkpiece /Monitor software.

Benefits
                     The operating manual allows the target group to get familiar with the software user interface.
                     Based on the manual, the target group is capable of responding to disturbances and taking
                     corrective action.

Standard scope
                     This documentation only describes the functionality of the standard version. This may differ
                     from the scope of the functionality of the system that is actually supplied. Please refer to the
                     ordering documentation only for the functionality of the supplied drive system.
                     It may be possible to execute other functions in the system which are not described in this
                     documentation. This does not, however, represent an obligation to supply such functions with
                     a new control or when servicing.
                     For reasons of clarity, this documentation cannot include all of the detailed information on all
                     product types. Further, this documentation cannot take into consideration every conceivable
                     type of installation, operation and service/maintenance.
                     The machine manufacturer must document any additions or modifications they make to the
                     product themselves.

Analyze MyWorkpiece /Monitor
Operating Manual, 09/2022, A5E47919940B AE                                                                              7
Introduction
1.3 Documentation on the internet

Websites of third-party companies
                  This document may contain hyperlinks to third-party websites. Siemens is not responsible for
                  and shall not be liable for these websites and their content. Siemens has no control over the
                  information which appears on these websites and is not responsible for the content and
                  information provided there. The user bears the risk for their use.

1.3            Documentation on the internet

1.3.1          Documentation overview SINUMERIK ONE
                  Comprehensive documentation about the functions provided in SINUMERIK ONE Version 6.13
                  and higher is provided in the Documentation overview SINUMERIK ONE (https://
                  support.industry.siemens.com/cs/ww/en/view/109768483).

                  You can display documents or download them in PDF and HTML5 format.
                  The documentation is divided into the following categories:
                  • User: Operating
                  • User: Programming
                  • Manufacturer/Service: Functions
                  • Manufacturer/Service: Hardware
                  • Manufacturer/Service: Configuration/Setup
                  • Manufacturer/Service: Safety Integrated
                  • Information and training
                  • Manufacturer/Service: SINAMICS

                                                                                        Analyze MyWorkpiece /Monitor
8                                                                        Operating Manual, 09/2022, A5E47919940B AE
                                                                                                      Introduction
                                                                                   1.5 mySupport documentation

1.3.2            Documentation overview SINUMERIK 840D sl
                     You will find extensive documentation on the functions of SINUMERIK 840D sl from version 4.8
                     SP4 at 840D sl documentation overview (https://support.industry.siemens.com/cs/ww/en/view/
                     109766213).

                     You can display documents or download them in PDF and HTML5 format.
                     The documentation is divided into the following categories:
                     • User: Operating
                     • User: Programming
                     • Manufacturer/Service: Functions
                     • Manufacturer/Service: Hardware
                     • Manufacturer/Service: Configuration/Setup
                     • Manufacturer/Service: Safety Integrated
                     • Manufacturer/Service: SINUMERIK Integrate/MindApp
                     • Information and training
                     • Manufacturer/Service: SINAMICS

1.4              Feedback on the technical documentation
                     If you have any questions, suggestions or corrections regarding the technical documentation
                     which is published in the Siemens Industry Online Support, use the link "Send feedback" link
                     which appears at the end of the entry.

1.5              mySupport documentation
                     With the "mySupport documentation" web-based system you can compile your own individual
                     documentation based on Siemens content, and adapt it for your own machine documentation.
                     To start the application, click on the "My Documentation" tile on the mySupport homepage
                     (https://support.industry.siemens.com/cs/ww/en/my):

Analyze MyWorkpiece /Monitor
Operating Manual, 09/2022, A5E47919940B AE                                                                          9
Introduction
1.6 Service and Support

                  The configured manual can be exported in RTF, PDF or XML format.

                  Note
                  Siemens content that supports the mySupport documentation application can be identified by
                  the presence of the "Configure" link.

1.6            Service and Support

Product support
                  You can find more information about products on the internet:
                  Product support (https://support.industry.siemens.com/cs/ww/en/)
                  The following is provided at this address:
                  • Up-to-date product information (product announcements)
                  • FAQs (frequently asked questions)
                  • Manuals
                  • Downloads
                  • Newsletters with the latest information about your products
                  • Global forum for information and best practice sharing between users and specialists
                  • Local contact persons via our Contacts at Siemens database (→ "Contact")
                  • Information about field services, repairs, spare parts, and much more (→ "Field Service")

                                                                                        Analyze MyWorkpiece /Monitor
10                                                                       Operating Manual, 09/2022, A5E47919940B AE
                                                                                                       Introduction
                                                                                           1.6 Service and Support

Technical support
                     Country-specific telephone numbers for technical support are provided on the internet at
                     address (https://support.industry.siemens.com/cs/ww/en/sc/4868) in the "Contact" area.
                     If you have any technical questions, please use the online form in the "Support Request" area.

Training
                     You can find information on SITRAIN at the following address (https://www.siemens.com/
                     sitrain).
                     SITRAIN offers training courses for automation and drives products, systems and solutions from
                     Siemens.

Siemens support on the go

                     With the award-winning "Siemens Industry Online Support" app, you can access more than
                     300,000 documents for Siemens Industry products – any time and from anywhere. The app can
                     support you in areas including:
                     • Resolving problems when implementing a project
                     • Troubleshooting when faults develop
                     • Expanding a system or planning a new system
                     Furthermore, you have access to the Technical Forum and other articles from our experts:
                     • FAQs
                     • Application examples
                     • Manuals
                     • Certificates
                     • Product announcements and much more
                     The "Siemens Industry Online Support" app is available for Apple iOS and Android.

Data matrix code on the nameplate
                     The data matrix code on the nameplate contains the specific device data. This code can be read
                     with a smartphone and technical information about the device displayed via the "Industry
                     Online Support" mobile app.

Analyze MyWorkpiece /Monitor
Operating Manual, 09/2022, A5E47919940B AE                                                                       11
Introduction
1.8 General Data Protection Regulation

1.7            OpenSSL
                  This product can contain the following software:
                  • Software developed by the OpenSSL project for use in the OpenSSL toolkit
                  • Cryptographic software created by Eric Young.
                  • Software developed by Eric Young
                  You can find more information on the internet:
                  • OpenSSL (https://www.openssl.org)
                  • Cryptsoft (https://www.cryptsoft.com)

1.8            General Data Protection Regulation
                  Siemens observes standard data protection principles, in particular the data minimization rules
                  (privacy by design).
                  For this product, this means:
                  The product does not process or store any personal data, only technical function data (e.g. time
                  stamps). If the user links this data with other data (e.g. shift plans) or if he/she stores person-
                  related data on the same data medium (e.g. hard disk), thus personalizing this data, he/she must
                  ensure compliance with the applicable data protection stipulations.

                                                                                           Analyze MyWorkpiece /Monitor
12                                                                          Operating Manual, 09/2022, A5E47919940B AE
Fundamental safety instructions                                                                                2
2.1              General safety instructions

                           WARNING
                     Danger to life if the safety instructions and residual risks are not observed
                     If the safety instructions and residual risks in the associated hardware documentation are not
                     observed, accidents involving severe injuries or death can occur.
                     • Observe the safety instructions given in the hardware documentation.
                     • Consider the residual risks for the risk evaluation.

                           WARNING
                     Malfunctions of the machine as a result of incorrect or changed parameter settings
                     As a result of incorrect or changed parameterization, machines can malfunction, which in turn
                     can lead to injuries or death.
                     • Protect the parameterization against unauthorized access.
                     • Handle possible malfunctions by taking suitable measures, e.g. emergency stop or
                        emergency off.

2.2              Warranty and liability for application examples
                     Application examples are not binding and do not claim to be complete regarding configuration,
                     equipment or any eventuality which may arise. Application examples do not represent specific
                     customer solutions, but are only intended to provide support for typical tasks.
                     As the user you yourself are responsible for ensuring that the products described are operated
                     correctly. Application examples do not relieve you of your responsibility for safe handling when
                     using, installing, operating and maintaining the equipment.

2.3              Security information
                     Siemens provides products and solutions with industrial security functions that support the
                     secure operation of plants, systems, machines and networks.
                     In order to protect plants, systems, machines and networks against cyber threats, it is necessary
                     to implement – and continuously maintain – a holistic, state-of-the-art industrial security
                     concept. Siemens’ products and solutions constitute one element of such a concept.
                     Customers are responsible for preventing unauthorized access to their plants, systems,
                     machines and networks. Such systems, machines and components should only be connected to

Analyze MyWorkpiece /Monitor
Operating Manual, 09/2022, A5E47919940B AE                                                                         13
Fundamental safety instructions
2.3 Security information

                   an enterprise network or the internet if and to the extent such a connection is necessary and only
                   when appropriate security measures (e.g. firewalls and/or network segmentation) are in place.
                   For additional information on industrial security measures that may be implemented, please
                   visit
                   https://www.siemens.com/industrialsecurity (https://www.siemens.com/industrialsecurity).
                   Siemens’ products and solutions undergo continuous development to make them more secure.
                   Siemens strongly recommends that product updates are applied as soon as they are available
                   and that the latest product versions are used. Use of product versions that are no longer
                   supported, and failure to apply the latest updates may increase customer’s exposure to cyber
                   threats.
                   To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed
                   under
                   https://www.siemens.com/cert (https://www.siemens.com/cert).
                   Further information is provided on the Internet:
                   Industrial Security Configuration Manual (https://support.industry.siemens.com/cs/ww/en/
                   view/108862708)

                           WARNING
                   Unsafe operating states resulting from software manipulation
                   Software manipulations, e.g. viruses, Trojans, or worms, can cause unsafe operating states in
                   your system that may lead to death, serious injury, and property damage.
                   • Keep the software up to date.
                   • Incorporate the automation and drive components into a holistic, state-of-the-art industrial
                      security concept for the installation or machine.
                   • Make sure that you include all installed products into the holistic industrial security concept.
                   • Protect files stored on exchangeable storage media from malicious software by with suitable
                      protection measures, e.g. virus scanners.
                   • On completion of commissioning, check all security-related settings.

                                                                                           Analyze MyWorkpiece /Monitor
14                                                                          Operating Manual, 09/2022, A5E47919940B AE
Overview                                                                                                      3
3.1              System description
                     Analyze MyWorkpiece /Monitor is a SINUMERIK Edge application for qualitative monitoring and
                     evaluation of the processing procedure. Various measured values are stored for this purpose
                     during processing.
                     The functionality of the application can be divided into the following steps:
                     1. Training machining operation
                        – Users import or create a model as basis for monitoring the machining process.
                     2. Monitoring the machining operation
                        – The user defines and configures the process steps or operations to be monitored in "jobs".
                        – The use case records all values that are available on the data bus of the SINUMERIK control
                          system.
                        – The data defined and recorded in this way is stored in SINUMERIK Edge and preprocessed
                          after completion of the specified operation.
                        – The data are evaluated using the "Six-Sigma" statistical procedure or a user-defined
                          algorithm.
                          - The result is saved in a report.
                          - The result is reported back to the control in a global user variable (GUD).
                        – Using the "Direct Monitoring" function, you can analyze intermediate data (data that are
                          almost in real time) of an active monitoring job.
                        – Using the "Measuring cycle" function, you can monitor workpiece-related measurements
                          integrated in the machine, which are performed based on SINUMERIK measuring cycles.
                     The user receives an MQTT notification if a new result is available and can be requested using
                     REST API.
                     Based on the result, the user can decide whether the processed operation was good or bad in
                     terms of quality. For this assessment, limits are defined beforehand by reference processing.

                     Note
                     "Six-Sigma" procedure
                     "Six-Sigma" is a statistical procedure used in quality assurance.

Analyze MyWorkpiece /Monitor
Operating Manual, 09/2022, A5E47919940B AE                                                                        15
Overview
3.1 System description

Creating a model
                  In order to detect a processing procedure anomaly (operation good or bad) during production,
                  the processing procedure must be analyzed beforehand:
                  1. Record (capture) the machining process data using Analyze MyWorkpiece /Capture.
                  2. Create a model:
                     – Import the Capture data from Analyze MyWorkpiece /Capture
                     – Using triggers, split-up the data into individual operations.
                       The process data for an operation is called TDU (Training Data Unit).
                     – Create training data sets from Capture data.
                       Several TDUs for the same operation are combined in training data sets.
                     – Train the model based on the training data set.
                       Assuming that the data in the training data set have a Gaussian (standard) distribution,
                       expected value μ and the standard deviation σ can be derived for every data point. If 6σ is
                       defined as the maximum permitted deviation, a model can be calculated using the "Six-
                       Sigma" method from the TDUs.
                  3. Assign the model a monitoring job.
                                                           4JY 4JHNB NPEFM USBJOJOH

                                5%6T                                                                               .PEFM

                              4QJOEMF
                         UPSRVF </N>

                                                              з   з     з   u      з    з    з
                                                                                 4QJOEMF UPSRVF </N>

                                                                                               Analyze MyWorkpiece /Monitor
16                                                                              Operating Manual, 09/2022, A5E47919940B AE
                                                                                                              Overview
                                                                                                    3.2 Users and rights

Operator control structure
                     Analyze MyWorkpiece /Monitor contains the following functions:
                     • Import Capture Data (Page 27)
                         – Import machining process data from Analyze MyWorkpiece /Capture as basis for training
                           the model
                     • Create Training Data Unit Sets (Page 33)
                         – Create a training data set from Capture data as basis for the model training
                     • Train Models (Page 45)
                         – Create a model based on training data sets
                     • Manage Monitoring Jobs (Page 59)
                         – Manage job configurations
                     • Analyze Monitoring Results (Page 69)
                         – View and manage result reports
                     •    Configure Settings
                         You make these settings once after installing Analyze MyWorkpiece /Monitor - or while
                         operational under "Configure Settings", e.g. under "Data retention rules".
                         You can find more information on data retention rules in Chapter Managing memory space
                         (Page 22).
                         More information about user settings is provided in the
                         SINUMERIK Edge Installation Manual, Analyze MyWorkpiece /Monitor.
                     • User-defined algorithm (Page 79)
                     • Direct Monitoring (Page 89)
                     • Measurement cycle (Page 97)

3.2              Users and rights
                     To access the Analyze MyWorkpiece /Monitor application, a local user on the SINUMERIK Edge
                     must be assigned to the user group listed below. To do this, the system administrator for the
                     SINUMERIK Edge device creates the user group, and creates one or several users, who are
                     assigned to this user group.
                     More information about the user group is provided in the
                     Installation Manual SINUMERIK Edge, Analyze MyWorkpiece /Monitor.

User group
                     The following user group is available for Analyze MyWorkpiece /Monitor:

                      User group              Authorizations
                      amwmonitor              Access to all functions of Analyze MyWorkpiece /Monitor.

Analyze MyWorkpiece /Monitor
Operating Manual, 09/2022, A5E47919940B AE                                                                           17
Overview
3.3 Starting Analyze MyWorkpiece /Monitor

3.3            Starting Analyze MyWorkpiece /Monitor
                  Analyze MyWorkpiece /Monitor is started by entering an URL in the browser.
                  After successfully logging in, the home page is called with an overview of all functions.

Requirement
                  • SINUMERIK Edge has been configured and commissioned.
                  • To create models in Analyze MyWorkpiece /Monitor, machining process data recorded using
                    Analyze MyWorkpiece /Capture must be available.

More information
                  You can obtain the following information in the menu, in the upper left-hand corner:

                   Information               Description
                   Software from third-par‐ Contains information about the license terms of the third-party software used.
                   ty suppliers
                   Readme                    Contains the latest changes that are not listed in the user manual and con‐
                                             straints.
                   User Manual               This User Manual.
                   Version number            Version number of Analyze MyWorkpiece /Monitor.

                                                                                               Analyze MyWorkpiece /Monitor
18                                                                              Operating Manual, 09/2022, A5E47919940B AE
                                                                                                        Overview
                                                                                            3.4 Change password

Procedure
                     1. Enter the following address in the browser:
                        https://<ip-address-of-edgebox>:5443/amwmonitor
                        The login page is displayed.
                     2. Enter your Analyze MyWorkpiece /Monitor user name and password.
                        Information on users and the user group can be found in the section: Users and rights
                        (Page 17).
                     3. Click the "Login" button.
                        The home page opens.

3.4              Change password
                     Change your password at regular intervals.

Analyze MyWorkpiece /Monitor
Operating Manual, 09/2022, A5E47919940B AE                                                                      19
Overview
3.7 Filtering data

Procedure
                     1. Open the drop-down list at the top right in the title bar.

                     2. Click "Change Password".
                        You are redirected to the "miniweb" administration environment.
                     3. Change the password.
                     More information about changing the password is provided in the Industrial Edge User
                     Documentation.

3.5             Switch language
                     The user interface is available in the following languages:
                     • English
                     • German

Procedure
                     1. Open the drop-down list at the top right in the title bar.

                     2. Click on your chosen language.
                        The user interface is displayed in the required language.

3.6             Sign out
                     If you want to exit Analyze MyWorkpiece /Monitor, then sign out on the SINUMERIK Edge
                     administration page.

Procedure
                     1. Open the drop-down list at the top right in the title bar.

                     2. Select "Logout".
                        You are transferred to the SINUMERIK Edge administration page.
                     3. On the SINUMERIK Edge administration page, select "Logout".

3.7             Filtering data
                     On overview pages, Analyze MyWorkpiece /Monitor provides the option of reducing the amount
                     of data that is displayed using the filter function.

                                                                                             Analyze MyWorkpiece /Monitor
20                                                                            Operating Manual, 09/2022, A5E47919940B AE
                                                                                                                      Overview
                                                                                                              3.7 Filtering data

Symbols
                     The following symbols are taken into account when filtering:

                      Symbol                 Description
                                             Opens the "My Filters" menu.
                                             Copies the selected filter to the "My Filters" list.

                                             Deletes the selected filter criterion from the current filter.
                                             Deletes the corresponding filter from the "My Filters" list.
                                             Adds additional criteria to the current filter.
                                             Closes the "My Filters" menu.

Procedure
                     1. Click the "Filter" symbol.
                        The "My Filters" menu opens and various filter dialogs are listed corresponding to the tasks.
                     2. Select a filter from the "My Filters" list.
                        - OR -
                        Define a new filter.
                     3. To do this, select the filter criterion from the "Attribute" drop-down list.
                     4. In the "Value" field, enter the exact text or the number being searched for and in the full
                        length.
                        Placeholders are not supported.
                     5. Add the filter criterion for the current filter using the "+" character.
                        Remove the corresponding filter criterion using the "Delete" symbol.
                     6. If you wish to save the filter for reuse:
                        – Enter a filter name.
                        – Click on "Save".
                          The filter is displayed in the "My Filters" list.
                     7. Click on "Reset filter" to redisplay all of the data.

Analyze MyWorkpiece /Monitor
Operating Manual, 09/2022, A5E47919940B AE                                                                                   21
Overview
3.8 Managing memory space

3.8          Managing memory space
                In the user settings, Analyze MyWorkpiece /Monitor provides the option of freeing-up memory
                space.

                                                                                     Analyze MyWorkpiece /Monitor
22                                                                    Operating Manual, 09/2022, A5E47919940B AE
                                                                                                             Overview
                                                                                         3.9 Managing MQTT service

Procedure
                     1. On the home page, click on "Configure Settings".

                     2. Page "Configure Settings" opens.
                        – Under "Data retention rules" in the left-hand area, you can define rules for managing the
                          memory space; this is automatically run in the background in order to continuously
                          ensure smooth operation.
                        – You can define how the system should respond if memory capacity is no longer available:
                          If you activate option "Deactivate all monitoring jobs", all active monitoring jobs are
                          terminated and data is no longer recorded.
                          If you activate option "Delete oldest monitoring results", then the oldest reports are
                          deleted. If you also activate the suboption, reports with positive results are deleted before
                          the old reports with negative results.
                        – Under "Advanced settings: Remove…" you can define when reports are deleted with a
                          fine granularity:
                          You can define that reports are deleted once they have been successfully downloaded.
                          You can define that reports are deleted independent of the result once they are older than
                          "x" days.
                          You can define that reports with a positive result are deleted after "x" days.
                        – Memory space utilization is displayed under "Monitor storage" in the right-hand area.
                        – To permanently delete all data belonging to a category (temporary data, job reports, …),
                          click on the "Delete" symbol at the end of the corresponding line.

3.9              Managing MQTT service
                     In the user settings, Analyze MyWorkpiece /Monitor provides the option of configuring an MQ TT
                     connection.

Analyze MyWorkpiece /Monitor
Operating Manual, 09/2022, A5E47919940B AE                                                                          23
Overview
3.9 Managing MQTT service

                 Notifications (MQTT notifications) can then be sent to an MQTT broker to inform MQTT clients
                 that a monitoring job has been completed and a report is available that can be downloaded.
                 For each completed monitoring job, Analyze MyWorkpiece /Monitor sends an MQTT notification
                 to the configured MQTT broker, which contains a download link for the report that has been
                 generated, the corresponding monitoring results and additional information regarding the
                 completed monitoring job.
                 The MQTT interface can be used as alternative to REST API - or in conjunction with REST API - to
                 obtain monitoring results and to avoid unnecessary REST queries.
                 You can find additional general information on the MQTT protocol here: MQTT.org (https://
                 mqtt.org/)

                 Note
                 • The MQTT client authentication with user name and password must be activated in the
                   MQTT broker configuration to check the client identity.
                 • User name and password are transferred to the MQTT broker in plain text as no data transfer
                   encryption is used for MQTT communication.

Requirement
                 An MQTT server (MQTT broker) was set up, which can be accessed from SINUMERIK Edge (on the
                 factory network side).

Procedure
                 1. On the home page, click on "Configure Settings".

                 2. Page "Configure Settings" opens.

                                                                                         Analyze MyWorkpiece /Monitor
24                                                                        Operating Manual, 09/2022, A5E47919940B AE
                                                                                                         Overview
                                                                                      3.9 Managing MQTT service

                     3. Click on "Activate MQTT service" and populate the following text boxes:
                        – Network address of the MQTT broker and port: IP address and port of your MQTT server
                          (protocol prefix "tcp://" is required)
                        – Target topic: The name of the MQTT topic that is used to publish MQTT notifications (case
                          sensitive)
                        – User name and password: for authentication on your MQTT server

                     4. To save the configuration, click on "Save".
                        Analyze MyWorkpiece /Monitor starts by sending MQTT notifications if the configuration was
                        correctly configured.

Analyze MyWorkpiece /Monitor
Operating Manual, 09/2022, A5E47919940B AE                                                                      25
Overview
3.9 Managing MQTT service

                                           Analyze MyWorkpiece /Monitor
26                          Operating Manual, 09/2022, A5E47919940B AE
Import Capture Data                                                                                                  4
4.1              Overview
                     To create or train a model, first import the machining process data, which was recorded/traced
                     using Analyze MyWorkpiece /Capture.

Requirement
                     • Analyze MyWorkpiece /Capture or Analyze MyWorkpiece /Capture for Analysis must be
                       installed on the same Edgebox.
                     • Recording files created with Analyze MyWorkpiece /Capture are available.

Functions and data
                     The following functions and data are available:

                      Function/data            Description
                                               Navigates to the previous page.

                                               Filters the list of Capture jobs
                      Import for Capture job   Capture job name
                                               The name is assigned by the Analyze MyWorkpiece /Capture application
                      Available runs           Number of data sets available on this machine that can be imported.
                      Imported runs            Number of data sets that have already been imported.
                      Duration [hh:mm:ss]      Data volume that was imported as complete duration in the format [Hours:Mi‐
                                               nutes:Seconds].
                                               Deletes the imported data of the Capture job in Analyze MyWorkpiece /Monitor
                                               The data is not deleted from Analyze MyWorkpiece /Capture.
                                               This symbol is only available if Capture Job Runs were imported.

Analyze MyWorkpiece /Monitor
Operating Manual, 09/2022, A5E47919940B AE                                                                               27
Import Capture Data
4.1 Overview

Procedure
                 1. Click the "Import Capture Data" button on the home page.

                 2. The "Capture Job Import Overview" page opens and displays an overview of the machining
                    process data available for import and the already imported machining process data.
                      – Click on the column header to sort data sets in either ascending or descending order in a
                        column.
                      – To reduce the number of data sets listed, click on the "Filter" symbol.
                        More information is provided in Chapter: Filtering data (Page 20).
                      – You can import a new run of a Capture job.
                        More information is provided in Chapter: Importing records of a Capture job (Page 29)
                      – You can delete imported runs of a Capture job.
                        The deleted data remain available in Analyze MyWorkpiece /Capture for a subsequent re-
                        import, assuming that they were not deleted directly beforehand in Capture.
                        More information is provided in Chapter: Deleting the record of a Capture job (Page 31).
                      – You can determine the cause as to why an import was unsuccessful.
                        More information is provided in Chapter: Determining why an import was not successful
                        (Page 31).

                                                                                          Analyze MyWorkpiece /Monitor
28                                                                         Operating Manual, 09/2022, A5E47919940B AE
                                                                                                          Import Capture Data
                                                                                     4.2 Importing records of a Capture job

4.2              Importing records of a Capture job
                     Every Capture job contains one or several runs that you can import.

Functions and data
                     The following functions and data are available:

                      Functions/data             Description
                                                 Check box to select a run.
                                                 All runs are selected if you activate the check box in the column header.
                      Job run                    Name of the run
                                                 As default setting, the time stamp of the recording is used as name.
                      No.                        Run number.
                      Time at the start of re‐   Displays the time at the start of recording [Year-Month-Day;Hour:Minute:Sec‐
                      cording                    ond]
                      Duration [hh:mm:ss]        Length of the recording in the format [Hour:Minute:Second].
                      Status

Показано початок документа. Повний текст — у PDF за посиланням вище.