| Вид документа | Технічний документ |
|---|---|
| Виробник | SIEMENS |
| Код документа | sinumerik-mcu-1720 |
| Сторінок | 27 |
| Мова документа | англійська |
| Розмір файлу | 0.9 МБ |
Текст документа
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
Table of contents
1 SOFTWARE COMPONENTS ............................................................................................................................................. 4
2 FUNCTIONS and OPTIONS .............................................................................................................................................. 5
2.1 Functions ........................................................................................................................ 5
2.2 Optionen ......................................................................................................................... 6
3 PRECONDITION .............................................................................................................................................................. 9
3.1 Software ......................................................................................................................... 9
3.2 Hardware ........................................................................................................................ 9
3.3 Storage media.................................................................................................................. 9
3.4 Software Tools ................................................................................................................. 9
3.5 Other requirements ......................................................................................................... 10
4 INSTALLATION.............................................................................................................................................................. 11
4.1 General information on installing the CNC -Software............................................................ 11
4.2 Installing the NCU service system on a USB stick................................................................. 11
4.3 Installing the CNC software .............................................................................................. 12
4.3.1Upgrading the firmware .................................................................................................................................... 12
4.3.2Upgrading the NCU system software ................................................................................................................. 13
5 Notes and restrictions .................................................................................................................................................. 16
5.1 General notes/restrictions ............................................................................................... 16
5.2 Security changes ............................................................................................................. 18
5.2.1CNC-Software.................................................................................................................................................... 18
5.2.2TIA Portal Webserver ........................................................................................................................................ 18
5.3 References to other documents ........................................................................................ 19
5.4 Restrictions Industrial Cybersecurity ................................................................................. 19
5.5 Notes regarding the CNC software .................................................................................... 20
5.6 Notes regarding SINUMERIK STEP7 Toolbox ........................................................................ 22
5.7 Notes on compatibility SINUMERIK STEP7 Toolbox / PLC Basic program ................................. 23
5.8 Information regarding TIA Portal Startdrive ....................................................................... 23
5.9 Information regarding SINUMERIK BaseSoftware ................................................................. 24
5.10 Hinweise zu SINUMERIK Operate /PCU Modular for MC ....................................................... 24
5.11 Information regarding SINUMERIK ONE Commissioning ........................................................ 25
Page 1 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
5.12 Information regarding SINUMERIK Integrate Create MyHMI /3GL .......................................... 27
5.13 Drive ‚NC Extend‘ for EES ................................................................................................. 27
Page 2 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
This document is used as instructions for the SINUMERIK MCU1720 CNC software 1.24.
Please read the documents carefully because they contain important information for installing and using the software.
Siemens observes standard data protection principles, in particular the principle of privacy by design. For this product, this
means:
The product does not process or store any personal data, only technical function data (e.g. time stamps). If the user links this
data with other data (e.g. shift schedules) or if he/she stores personal data on the same medium (e.g. hard disk), thus
personalizing it, he/she has to ensure compliance with the applicable data protection stipulations.
Cybersecurity information
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and
continuously maintain – a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute
one element of such a concept. For more information about industrial cybersecurity, please visit
www.siemens.com/cybersecurity-industry.
Page 3 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
1 SOFTWARE COMPONENTS
CNC software 1.24 (internal version 01.24.00.00.028) contains the following components:
Component Version
PLC 06.24.01.01.010
NCK-Adapter 01.10.006
smted 06.24.00.00.011
Cycles 06.24.00.00.015
NCK 146.02.00
SINUMERIK Security Host 01.02.00.00.000122
SINUMERIK Logical Drives Deamon 07.01.0004
HMIARC tool 04.09.00.01.001
CP15431 02.00.09.02
Hypervisor 01.30.01.00
SINUMERIK Diagnosis Data Collector 02.09.02.00
COS 03.00.07.00
ComProxy 01.02.09
ComPH_S7 01.02.12
CM15425 02.00.10.03
Sinumerik ComServer 01.10.02
DiagSrv Application 01.22.01
SINUMERIK_DRM 01.00.00.03
NCKFSDRV 04.07.01.09.001
SINUMERIK Machining Technology Extension Framework 06.24.00.00.009
LinuxBase (NCU) 065.00.00.0026
Page 4 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
2 FUNCTIONS and OPTIONS
2.1 Functions
SW 1.24
• TIA Portal SINUMERIK STEP 7 Toolbox V19 SP1
see Online Help “Configuring and programming SINUMERIK” - “What’s new in V19 SP1”.
• SINUMERIK Operate /PCU modular for MC V1.24
• OPC-UA V4.2
SW 1.23 HF1
• none
SW 1.23
• Security Local User Management can be activated.
• Security Trust relation between IPC and NCU.
• TIA Portal SINUMERIK STEP 7 Toolbox V19
see Online Help “Planning and programming” - “What’s new in V19”.
• SINUMERIK Operate /PCU modular for MC V1.23
• OPC-UA V4.1SP1
SW 1.22 HF1
• none
SW 1.22
• TIA Portal Toolbox V18 SP1
• SINUMERIK Operate /PCU modular for MC V1.22
• HT2/HT10 functionality
• OPC-UA
SW 1.21 HF1
• none
SW 1.21
• none
SW 1.20 HF2
• none
SW 1.20 HF1
• none
SW 1.20
• none
Page 5 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
SW 1.15 SP3
• none
SW 1.15 SP2 HF2
• none
SW 1.15 SP2
• none
SW 1.15 SP1
• none
SW 1.15 HF1
• none
SW 1.15
• none
Functions:
• CU320-2PN can be used as NC axes
2.2 Optionen
SW 1.24
• none
SW 1.23
• none
SW 1.22 HF1
• none
SW 1.22
• SINUMERIK MC - SINUMERIK INTEGRATE LOCK MYCYCLES
6FC5800-0CP54-0YB0
• SINUMERIK MC - LAGESOLLWERTFILTER (erweitert)
6FC5800-0CS38-0YB0
• SINUMERIK MC - Bahnsteuerbetrieb (G64) erweitert
6FC5800-0CS37-0YB0
• SINUMERIK MC - SINUMERIK Operate /PCU Modular
6FC5800-0CQ11-0YB0
• SINUMERIK MC - Access MyMachine /OPC UA
6FC5800-0CP67-0YB0
• SINUMERIK MC - Access MyMachine /OPC UA - OEM
6FC5800-0CP83-0YB0
Page 6 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
• SINUMERIK PCU-Basesoftware /IPC (>=V15)
6FC5800-0CP83-0YB0
SW 1.21 HF1
• none
SW 1.21
• none
SW 1.20 HF2
• none
SW 1.20 HF1
• none
SW 1.20
• none
SW 1.15 SP3
• Archiving NC-data in Punch tape format
• Start-Stop PLC via HMI-OA Interface
SW 1.15 SP2 HF2
• none
SW 1.15 SP2
• none
SW 1.15 SP1
• none
SW 1.15 HF1
• none
SW 1.15
• 6FC5800-0CE00-0YB0 Protect MyMachine /3D Primitives, 1 ADD. CHANNAL
SW 1.14 HF3
• none
SW 1.14
• 6FC5800-0CM11-0YB0 SINUMERIK MC Fast INTERPOLATION CYCLE (IPO)
• 6FC5800-0CP86-0YB0 SINUMERIK PCU-BASESOFTWARE
• 6FC5800-0CW64-0YB0 SINUMERIK MC Fabrication ADVANCED package
• 6FC5800-0CW65-0YB0 SINUMERIK MC Fabrication PERFORMANCE package
SW 1.13 HF6
• none
SW 1.13 HF2
Page 7 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
• 6FC5800-0CA00-0YB0 ADDITIONAL 1 AXIS/SPINDLE
• 6FC5800-0CC10-0YB0 ADDITIONAL 1 CHANNEL
• 6FC5800-0CM02-0YB0 SYNCHRONOUS AXIS PAIR (GANTRY AXES)
• 6FC5800-0CM06-0YB0 TANGENTIAL CONTROL
• 6FC5800-0CM07-0YB0 POS.SWITCHING SIGNALS CAM-OPERATED SWITCHGROUP
• 6FC5800-0CM08-0YB0 CONTUR HANDWHEEL
• 6FC5800-0CM15-0YB0 MULTIPLE-AXIS INTERPOLATION
• 6FC5800-0CM18-0YB0 POLYNORMAL INTERPLOATION
• 6FC5800-0CM20-0YB0 ADMITTANCE LINKING AND CURVE TABLES
• 6FC5800-0CM27-0YB0 TRANSMIT AND PERIPHERAL SURFACE TRANSFORMING
• 6FC5800-0CM30-0YB0 MACHINING PACKAGE 5 AXES
• 6FC5800-0CM37-0YB0 OSCILLATION FUNCTION, BLOCK RELATED AND MODAL
• 6FC5800-0CM36-0YB0 SYNCHRONIZED ACTION STAGE 2
• 6FC5800-0CM37-0YB0 PATH VELOCITY-DEPENDENT ANALOG VALUE
• 6FC5800-0CM41-0YB0 ANALYSIS OF INTERNAL DRIVE VALUES
• 6FC5800-0CM43-0YB0 MULTIMODE ACTION
• 6FC5800-0CM48-0YB0 3D-TOOL RADIUS COMPENSATION
• 6FC5800-0CM54-0YB0 BIDIRECTIONAL COMPENSATION
• 6FC5800-0CM55-0YB0 SAG COMPENSATION, MULTI-DIMENSIONAL
• 6FC5800-0CM72-0YB0 GENERIC COUPLING CP-BASIC
• 6FC5800-0CM73-0YB0 GENERIC COUPLING CP-COMFORT
• 6FC5800-0CP18-0YB0 MESUREMENT OF MACHINE KINEMATIC
• 6FC5800-0CP28-0YB0 MEASURING CYCLES
• 6FC5800-0CP60-0YB0 RUN MYHMI /3GL
• 6FC5800-0CP61-0YB0 RUN MYHMI /WINCC
• 6FC5800-0CP75-0YB0 EXECUTE FROM EXTERNAL STORAGE (EES)
• 6FC5800-0CS03-0YB0 PROTECT MyMachine /3D PRIMITIVES
• 6FC5800-0CS07-0YB0 ADVANCED SURFACE
• 6FC5800-0CS16-0YB0 SPLINE-INTERPLOATION
• 6FC5800-0CS60-0YB0 SAFETY INTEGRATED /SI Logic
• 6FC5800-0CW61-0YB0 SINUMERIK MC ECO PACKAGE
• 6FC5800-0CW61-0YB0 SINUMERIK MC ADVANCED PACKAGE
• 6FC5800-0CW62-0YB0 SINUMERIK MC PERFORMANCE PACKAGE
• 6FC5800-0CW63-0YB0 SINUMERIK MC TECHNOLOGY PACKAGE
(Content: spline interpolation, multi-axis interpolation, TRANSMIT, measuring cycles, 5-axis machining package, tool
radius correction 3D)
Page 8 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
3 PRECONDITION
3.1 Software
• SINUMERIK Service System >= V06.50.00.00 (internal V065.00.00.0026)
Note: The internal version is currently displayed in the SINUMERIK Service System.
• Onboard SW (InitNCU) Image >=V06.00.38.00
• SINUMERIK ONE Commissioning auf MCU 1720 / IPC V6.24
• SINUMERIK Operate /PCU Modular for MC V1.24
3.2 Hardware
• SINUMERIK MCU1720 CNC-Software 1.24 may only be used on a SINUMERIK MCU 1720.
3.3 Storage media
• SD-Card 8GB - 6FC5822-1_G46-3YA_
3.4 Software Tools
• TIA Portal V19 Update (latest, not mandatory)
STEP 7 Professional, WinCC Advanced, STEP 7 Safety
• SINUMERIK STEP 7 Toolbox V19 SP1
• SINUMERIK Integrate Create MyHMI /WinCC V19
• Kombinationen TIA Portal / SINUMERIK STEP7 Toolboxen
SIMATIC TIA Portal SINUMERIK STEP7 Toolbox SINUMERIK Integrate Create MyHMI /WinCC
V17 Update 5 V17 Update 12 V17
V18 V18 Update 1 V18
V18 Update 2 V18 SP1 Update 1 V18 Update 2
V19 V19 V19
V19 V19 SP1 V19
• TIA Portal Startdrive V19
• SINUMERIK Integrate Create MyHMI /3GL V6.24
• SINUMERIK ONE Commissioning V6.24
• SINUMERIK Operate /PCU Modular for MC V1.24
• AccessMyMachine /P2P from V4.9 SP3
• Lock MyCycles (Option 6FC5800-0BP54-0YB0), Protector V2.11.0
Page 9 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
• SINUMERIK Service System V06.50.00.00
3.5 Other requirements
Page 10 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
4 INSTALLATION
4.1 General information on installing the CN C-Software
• The SINUMERIK Service System >= V06.50.00.00 (internal V065.00.00.0026) on a USB stick is required to install the
CNC software. Version.
Note: The internal version is currently displayed in the SINUMERIK Service System.
• A new installation can be carried out using the NCU service system and VNC Viewer (AccessMyMachine /P2P).
• The description of the procedure can be found in the SINUMERIK MC Commissioning manual (Chapter Installation /
upgrading) published in SIEMENS Industry Online Support.
• Upgrading with Create MyConfig is not released.
• The MCU1720 must have at least the InitNCU image version 06.00.38.00
4.2 Installing the NCU service system on a USB stick
Install the service stick image using tool "AccessMyMachine /P2P" V4.9 and higher using menu item «Tools – write image to CF
card».
Installing on MCU1720:
• After the installation has been completed, remove the USB stick from the PG/PC and boot an MCU 1720 one time
from this stick. The USB stick can be inserted in one of the two USB ports (X125, X135) of the MCU1720. To do this,
the NCK rotary switch of the MCU1720 must be set to >< 0. This boot process takes a little bit longer; a "P" in the 7-
segment display of the MCU indicates that the FAT partition of the images on the USB stick is adapted. The 7-segment
display goes dark after partitioning has been completed.
• Afterwards, reinsert the stick into the PG/PC. Under Windows, you can now see an empty USB stick. You can see the
installed version of the NCU service system in file "Eboot_version.txt". Now copy the required CNC software (file with
extension .tgz) to this stick.
• Now insert the USB stick into one of the two USB ports (X125, X135) and switch on the MCU1720 again (NCK rotary
switch of the MCU1720 >< 0)
• The MCU1720 is now rebooted from this USB stick. This is indicated as the 7-segment display is dark. The NCU service
system is called from the PG/PC using program "VNC Viewer AccessMyMachine /P2P" via interface X127. Set the
interface properties to "Automatically obtain IP address".
Page 11 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
• USB Stick 6AV6881-0AS42-0AA0 "USB-Flash Drive, 32 GB, USB3.0" is recommended.
4.3 Installing the CNC software
4.3.1 Upgrading the firmware
To do this, at the PG/PC, the files required must be copied to the service stick.
After this, the MCU 1720 is booted from the service stick:
Page 12 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
Select menu item «Firmware Update»:
Depending on the firmware update type, acknowledge the corresponding menu item with «OK», and follow the other
instructions.
4.3.2 Upgrading the NCU system software
To do this, at the PG/PC, the files required must be copied to the service stick.
After this, the MCU 1720 is booted from the service stick:
Select menu item «Update NCU Software and Data»:
Page 13 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
Select the appropriate menu item corresponding to the update type:
Select the desired SW package (.tgz) and confirm with «OK».
Page 14 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
Updated completed:
Page 15 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
5 NOTES AND RESTRICTIONS
5.1 General notes/restrictions
• Only an HMI base can be started on the MCU1720. This means that an HMI 3GL application and the SINUMERIK ONE
Commissioning Tool cannot be simultaneously started.
• Distributed NCK I/O connected to PROFINET
Distributed NCK I/O (IOs, drives) are only supported at the X150. This means
- Isochronous NCK drives such as CU320-2 PN can only be operated at the PROFINET PN1 interface (X150).
- NCK I/O such as ET200SP PN can only be operated at the PROFINET PN1 interface (X150).
Access from NCK to PROFINET I/O/drives is only supported up to PROFINET device number 126.
• Control loop optimization (tuning) S210 must be performed manually without SINUMERIK ONE Commissioning Tool
support
• PLC setup archive
If a PLC setup user archive is imported, this corresponds to transferring the CPU folder with all run-relevant objects
and the hardware configuration.
The CPU compares the content of the configuration on the SIMATIC memory card with the backed-up retentive data.
If the backed-up retentive data matches the data of the configuration on the SIMATIC memory card, then the
retentive data is retained.
If this data differs, the CPU automatically triggers a general reset (i.e. the retentive data is deleted).
• TIA Portal functionality web server
Access to the PLC web server via interfaces X127/X130 is not possible using the HTTPS protocol. Only HTTP is
supported.
Use interfaces X150/X160 when using HTTPS.
• CA Eco (Protect MyMachine /3D Primitives and Protect MyMachine /3D Primitives, 1 add. channel)
The CA Eco function together with an IPO clock of 2ms is currently not supported.
When activating the options "Protect MyMachine /3D Primitives - 6FC5800-0CS03-0Yx0 / Protect MyMachine /3D
Primitives, zus. 1 channel - 6FC5800-0CE00-0Yx0" a new CA algorithm is automatically activated.
The IPO load will be higher due to the new CA algorithm.
Collision avoidance is a computationally intensive function and is therefore not released with the "Fast Interpolation
Cycle" option.
Depending on the collision model used and computationally intensive NC functions, it may happen that the collision
checks cannot be completed in time. In this case, the collision protection is limited and alarm 26303 "Collision check
incomplete" is issued. This alarm can be suppressed by the machine manufacturer (MD11415
$MN_SUPRESS_ALARM_MASK_2 bit 29).
Technology G-code groups 59 must be set correctly (DYNNORM, DYNPOS, DYNROUGH, DYNSEMFIN, DYNFINISH,
DYNPREC).
Collision avoidance uses the emergency brake ramp in exceptional cases (alarm 26285). The following machine data
must be checked and set sensibly:
MD36610 $MA_AX_EMERGENCY_STOP_TIME
Page 16 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
MD36620 $MA_SERVO_DISABLE_DELAY_TIME
Depending on the machine and control configuration (low axis dynamics, small IPO cycle), the following machine data
may have to be increased:
MD18951 $MN_MM_COLLISION_PREVIEW_LEN
MD18952 $MN_MM_COLLISION_BRAKEPATH_LE
If alarm 26285 occurs, it may happen that you have to switch off collision avoidance for free driving via the HMI
Operate.
In the case of alarm 26280 in the JOG, reset must be activated before free driving.
• Program lists
Processing of program lists via PLC-NC interface (DB19) with Commissioning Tool is currently not supported.
• Manual reading of a data backup created in V1.14 using TEA file
When manually importing a data backup created in V1.14 using TEA files, the following reset alarm occurs: "1 error in
GUD, macro or INI file".
After charging, the operator is also prompted to trigger an NCK reset and after this the alarm is gone and the
controller is back to normal.
The general reading of the data backup and the adjustment of the remaining MDs is not affected.
When loading the archive, the alarm is also not noticeable, as a reset is triggered when the NCK is loaded anyway.
• General recommendation for the use of USB sticks at SINUMERIK-Operate/ SINUMERIK ONE Commissioning Tool
After data has been copied to the stick or changes have been made to files on the stick, a short waiting time (about 20
seconds) should be observed before the stick is removed.
• SINUMERIK Tuning Center
SINUMERIK ONE Operate / SINUMERIK ONE Commissioning is not supported.
Page 17 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
5.2 Security changes
5.2.1 CNC-Software
SW 1.24
• OpenSSL Upgrade to V3.1.3
SW 1.23 HF1
• None
SW 1.23
• OpenSSL Upgrade to V3.1.3
SW 1.22 HF1
• None
SW 1.22
• SMT - Secure Machine Tool (only PLC/HMI-Security)
SW 1.21 HF1
• None
SW 1.21
• OpenSSL Upgrade auf V3.0.7
5.2.2 TIA Portal Webserver
Safety-relevant notes for the TIA Portal web server
- Activating the web server in STEP 7
Activating the web server reduces the level of protection against unauthorized access to functions and data of this device from
the outside and via the network.
When accepting projects from suppliers, in which the web server is already activated and configured on the board, this safety
note is not displayed.
- Setting up the user administration
In STEP 7, in the area "Web server > User administration" you must extend the user list.
The user list offers you the following options:
- Create users
- Define access rights
- Assign passwords
Newly created users only have options available to them where the access rights have been specifically assigned.
If you are user that has not logged in, then you access the web server as user "Anyone". User rights should not be assigned to
user "Anyone".
Page 18 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
5.3 References to other documents
Content File name Comment
Resolved feature limitations Resolved_feature_limitations_1.24_EN
Restrictions In this document, chapter 5
SINUMERIK Service System SINUMERIK_Service_System_<xy>_DE/EN
SINUMERIK STEP7 Toolbox - PLC Path…\Documents\Readme\English
Basic Program ReadMe_PLCBP_en
ReadMe_PLCBPPlus_en
5.4 Restrictions Industrial Cybersecurity
• Security configuration data
Security configuration data (PLC Access Level Password, Protection of confidential PLC Data password, Security
Archive password) gets deleted, when encryption key for security configuration data cannot be found after startup.
This happens, when you put a SD Card into another NCU and reboot, since it is stored in the NCU hardware! In this
case you must read in the security archive to restore security configuration data.
• User Management
o Configuration of User Management requires mouse and keyboard on non-touch displays.
o User Lock does not work. If the user gets locked in the user management user can still log on.
• PLC Security
o The configuration of PLC Access Level Password in Operate requires a manual restart of Operate at the end.
Valid for: SINUMERIK MC and PLC S7-1500 standalone.
o Configuration of protection of confidential PLC data Password in Operate requires at the end a manually
reboot from Operate. Valid for: SINUMERIK MC and PLC S7-1500 standalone.
• Security Archives
o Security Archives taken from software V1.21 cannot be used.
• Security Event Log is not available for external SINUMERIK Operate /PCU modular for MC.
Page 19 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
5.5 Notes regarding the CNC software
SW 1.24
• none
SW 1.23 HF1
• none
SW 1.23
• OPC UA 4.1 SP1
To receive SINUMERIK alarms from a node of a Customer Specific Object Model the SINUMERIK node must be mapped.
• Higher protection levels of default directories are implemented for all systems which support DSF-archives. Possible
consequences are that certain procedures which are affected by higher protection levels (like trying to write in the CST-
directory without needed rights) must be changed. All protection levels from DSF-archives overwrite the current
protection levels, even the new introduced levels. The new protection levels are the following:
Directory Read Write Execute Show Delete
/_N_MPF_DIR 7 7 0 7 0
/_N_SPF_DIR 7 7 0 7 0
/_N_WKS_DIR 7 4 0 7 0
/_N_CST_DIR 7 0 0 7 0
/_N_CMA_DIR 7 2 0 7 0
/_N_CUS_DIR 7 3 0 7 0
/_N_DEF_DIR 7 3 0 7 0
/_N_SYF_DIR 7 7 0 3 0
/_N_COM_DIR 7 7 0 7 0
SW 1.22 HF1
• None
SW 1.22
• None
SW 1.20
• For the MD10619 $MN_COLLISION_TOLERANCE, the minimum input value has been changed from 0.001mm to 0.1mm
For upgrades where the original value was less than 0.1mm, the default value of 1mm is now automatically entered. If
protected areas come very close (< 1 mm), it may happen that the collision check reports a collision that has not been
Page 20 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
reported with a smaller tolerance. The FUNCTION PROTD (Measure distance between two protected areas) may provide a
slightly different value.
Password guidelines:
When an NC password is changed, the password for the respective Linux account is also changed.
i.e. when the manufacturer's password is changed, the password for the Linux account "manufact" is also changed.
IMPORTANT: After one of the existing NC passwords (e.g. SUNRISE) has been changed, it is no longer possible to change back
to the old password, as it does not correspond to the new guidelines (minimum length 8 characters, uppercase letter,
lowercase letter, number).
Notice:
If an access level in NCK is to be set by the PLC via FB4 (PI-Service_N_LOGIN), a password that is used for the NCK (and
simultaneously for Linux) must be precisely 8 characters long.
This scenario must be taken into consideration when assigning new passwords. Otherwise, passwords can be 8 - 32 characters
long.
The passwords for the NCK and the corresponding Linux accounts of the NCU basic system are now changed with the "Change
password" SINUMERIK ONE Commissioning Tool dialog.
Page 21 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
5.6 Notes regarding SINUMERIK STEP7 Toolbox
SINUMERIK STEP 7 Toolbox V19 must be used.
This toolbox can be used to engineer SINUMERIK MC hardware.
The software is an option package for SIMATIC TIA Portal V19
The following hardware is supported:
• MCU1720 V1.15, 1.20, 1.21, 1.22, 1.23, 1.24
Supported functions:
• Creating a hardware configuration
• Configuring the S7-1500 PLC
• Support of Safety Integrated
• SINUMERIK DSF archive hardware/software with alarm texts
• Creating NC tags via NC tag access
Unsupported functions:
• Function "Restore factory settings" via SIMATIC TIA Portal V18 is not supported.
• Uploading the PLC project from the MCU1720 is not supported.
New in SW-Version 19 SP1:
• see Online Help “Configuring and programming SINUMERIK” - “What’s new in V19 SP1”.
New in SW-Version 19:
• When a security program is loaded into the F-CPU, the serial number is read. The automatically read serial number
does not correspond to the serial number of the MCU1720 nameplate. To ensure a clear assignment, the serial
number of the F-PLC must be read out during commissioning.
There are two ways to determine the serial number:
o Read via Service Stick
Menu item - Show Status, section Mainboard/SerialNo
o Read via SINUMERIK ONE Commissioning Tool or SINUMERIK Operate /PCU modular for MC
Menu item - Diagnose/Version/Hardware
New in SW-Version 18 SP1:
• Installation precondition SIMATIC TIA Portal V18 Update 2
• Support MCU-Firmware NCU-Firmware for SINUMERIK ONE (V6.22) and SINUMERIK MC (V1.22)
• Support of HT2 and HT10 for SINUMERIK MC
• Online & Diagnose Editor for SINUMERIK NCU and SINUMERIK MCU with information on CNC-Software (from
V6.22/V1.22)
Page 22 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
• Configuration of WinCC Unified with NCU 1750 or NCU 1760 from V6.21 (option package Create MyHMI /WinCC
Unified must be installed)
• New version of the system library for SINUMERIK ONE PLC Basic Program plus (V12.0) with handwheel selection via
HMI
• Ctrl-E analysis as part of SINUMERIK ONE PLC Basic Program
• Release of Openness Clients for Windows Server Version (Windows Server 2022 Standard Version 21H2 (64Bit))
• Improved support of terminal modules and free telegrams in the Openness Client for axle drive assignment
• Optimized behavior of the command line parameters /pid and /dev for all Openness clients
New in SW-Version 18:
• Installation precondition SIMATIC TIA Portal V18
• SINUMERIK MC STEP7 Toolbox has been integrated into the SINUMERIK STEP7 Toolbox
• Support MCU-Firmware for V1.15, V1.20, V1.21. SW versions V1.13, V1.14 are no longer supported. Projects with
these firmware versions can be upgraded to V18 and continue to be used.
• Support for View-of-Things (VoT) für SINUMERIK MC PLCs
• Support for User Management and Access Control (UMAC) for SINUMERIK and SINUMERIK Openness
• Integration of the Openness Clients for the Engineering Workflow into the Toolbox Setup
• Openness clients for engineering workflow are additionally provided with programming interface via DLL
• Enhancement of the Openness API for importing SINUMERIK alarm texts
5.7 Notes on compatibility SINUMERIK STEP7 Toolbox / PLC Basic prog ram
The PLC Basic program and the projected NCU device are basically backwards compatible up to CNC-SW 6.15.
In the case that no new functions or functional improvements are required from higher versions of NCU devices (HW
configuration) and PLC Basic program, the PLC program does not need to be updated.
5.8 Information regarding TIA Portal Startdriv e
TIA Portal Startdrive V19 must be used.
Page 23 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
5.9 Information regarding SINUMERIK BaseSoftware
The following versions are available:
• SINUMERIK BaseSoftware V14 SP1 HF5
• SINUMERIK BaseSoftware V15
• SINUMERIK BaseSoftware V15 SP1
• SINUMERIK BaseSoftware V15 SP2
• SINUMERIK BaseSoftware V15 SP3
Notes regarding SINUMERIK BaseSoftware V15 SP3:
• none
Notes regarding SINUMERIK BaseSoftware V15 SP2:
• Upgrade from SINUMERIK BaseSoftware V14 SP2 to SINUMERIK BaseSoftware V15 SP2 is possible.
Notes regarding SINUMERIK BaseSoftware V15 SP1:
• SINUMERIK BaseSoftware V15 SP1 is required to operate H2 / HT10.
• Upgrade from SINUMERIK BaseSoftware V15 to SINUMERIK BaseSoftware V15 SP1 is possible.
Note regarding SINUMERIK BaseSoftware V15:
• It is not possible to upgrade from SINUMERIK BaseSoftware V14 SP1 HF5 to SINUMERIK BaseSoftware V15. The ICP
must be reinstalled.
By installing SINUMERIK Base Software, the IP address of the internal "Intel® l210 Gigabit Backplane Connection" interface is
set to the default value.
5.10 Hinweise zu SINUMERIK Operate /PCU Modular for M C
SINUMERIK Operate /PCU Modular for MC V1.24 must be used.
Note:
In addition, when using SINUMERIK Operate /PCU Modular for MC, the corresponding upgrade instructions must be followed.
SW 1.24
• none
SW 1.23 HF1
• none
SW 1.23
• none
SW 1.22 HF1
• none
Page 24 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
SW 6.22
• new Product
Notes:
Program Editor is not part of SINUMERIK Operate /PCU Modular, i.e., no files can be opened in the editor. For SINUMERIK
Operate /PCU Modular, only the "Diagnosis" and "Setup" areas are available.
5.11 Information regarding SINUMERIK ONE Commissioning
SINUMERIK ONE Commissioning V6.24 must be used.
Note:
In addition, when using SINUMERIK ONE Commissioning, the corresponding upgrade instructions must be followed.
SW 6.24
• none
SW 6.23 HF1
• none
SW 6.23
• none
SW 6.22 HF1
• none
SW 6.22
• none
SW 6.21
• Fixed: Absolute PLC address with string length makes other addresses in NC/PLC variables table unreadable
• Security functions (Softkey Setup >> Security) are currently not supported.
SW 1.20
• Commissioning tool not operable
If the connection to the NC/PLC is not configured, the commissioning tool cannot be operated.
Workaround:
Connecting to NC/PLC
• Absolute PLC address with string length makes other addresses in NC/PLC variables table unreadable
If a subscription with an array is made for a SINUMERIK MC and then more variables are added, these variables are no
longer resolved after the array.
Page 25 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
Workaround:
Put array at the end of the variable Set Screen. Or deduct OA as your own subscription for HMI.
Existing SW-Versions:
• Connection to the NC/PLC
In order that in "SINUMERIK ONE Commissioning" a connection can be established to the NC/PLC, a correct network
adapter (Gigabit Backplane Connection TCPIP.1) must be manually set in access point S7ONLINE and SINUMERIK.
Otherwise, alarm 150202 is displayed at the HMI. This can be done using the "Siemens Communication Settings" tool.
• Manufacturer, PLC alarms
It is not possible to edit/create manufacturer PLC alarms using the "Edit alarm texts" screen form.
Workaround: Create alarm and message texts using alarm text files. Refer to the "SINUMERIK Operate“ IM9
Commissioning Manual, Chapter 13
• Areas/softkeys
For the MCU1720, the following areas/softkeys were removed/disabled:
- Diagnostics >> ">" >> TCP/IP Diag. >> SK "MCP"
- Diagnostics >> ">" >> TCP/IP Diag. >> SK "TCU"
- Commissioning >> HMI >> SK "Ctrl-Energy"
- Commissioning >> ">" >> Networks >> SK "OPC-UA"
- Diagnostics >> SK "Remote Diag"
- Commissioning >> NC >> PROFIBUS >> SK "DP Integrated"
- Commissioning >> NC >> PROFIBUS >> SK "DP X126"
- Commissioning >> NC >> PROFIBUS >> SK "DP X136"
Page 26 / 27 C0 - Unrestricted © Siemens AG 2024
2024-07-25
SINUMERIK MCU 1720
CNC software 1.24
• Program lists
Processing of program lists via PLC-NC interface (DB19) with Commissioning Tool is currently not supported.
• IBN-archive factory setting of this machine
Creating an IBN archive "Factory setting of this machine" is currently not supported with the Commissioning Tool.
• Machine registration
The registration of the machine via the SINUMERIK ONE Commissioning Tool is currently not supported.
5.12 Information regarding SINUMERIK Integrate Create MyHMI /3GL
SINUMERIK Integrate Create MyHMI /3GL V6.24 must be used.
Existing SW-Versions:
• The HMI base of SINUMERIK ONE, included in "SINUMERIK Integrate Create MyHMI /3GL", should be used for the
MCU1720.
• The ToolManagment service has not been released.
• The infrastructure service has not been released.
For additional information, see the manual for the "SINUMERIK Integrate Create MyHMI /3GL" programming package.
5.13 Drive ‚NC Extend‘ for EES
Preparation
1. On the IPC in Windows (Explorer) set up drive sharing for directory
C:/Programme(x86)/Siemens/SinumerikCommissioning/user/sinumerik/data/prog. The shared drive name must be
LOCAL_DRIVE.
2. Start SINUMERIK ONE Commissioning on MCU1720
Set the option P75 under "Commissioning/Licenses/All Options".
Perform NCK-Reset and restart Commissioning-Tool.
Page 27 / 27 C0 - Unrestricted © Siemens AG 2024Документ виробника, опублікований як довідковий матеріал на обладнання, яке ми постачаємо. Правовласник може попросити прибрати його — приберемо.