SIMOTICS M-1FE2 built-in motors
Introduction
Fundamental safety
instructions 1
Special safety notices for
2
SIMOTICS handling built-in motors
Description 3
SIMOTICS M-1FE2 built-in motors Motor components,
4
characteristics and options
Preparing for use 5
Hardware Installation Manual
Mechanical mounting 6
Connection 7
Commissioning 8
Operation 9
Service and maintenance 10
Decommissioning and
disposal 11
Dimensional drawings 12
Spare parts 13
List of abbreviations A
10/2021
A5E50074509B AB
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG Document order number: . Copyright © Siemens AG 2015 - 2021.
Digital Industries Ⓟ 11/2021 Subject to change All rights reserved
Postfach 48 48
90026 NÜRNBERG
GERMANY
Introduction
Keeping the documentation safe
This documentation should be kept in a location where it can be easily accessed and made
available to the personnel responsible.
Target group
This Hardware Installation Manual addresses installation technicians, commissioning
engineers, service and maintenance personnel.
About this Hardware Installation Manual
This Hardware Installation Manual applies to the SIMOTICS M-1FE2 built-in motor, called
"1FE2" in the following text.
The Hardware Installation Manual explains how to handle the 1FE2 from delivery to disposal.
The Hardware Installation Manual provides information about the components that enable
the target group to install, set up, test, commission, operate, and troubleshoot the products
and systems correctly and safely.
• Before you start using the motor, you must read this Hardware Installation Manual. This
will ensure safe, problem-free operation and maximize the service life of the motor.
• Always follow the safety instructions and notices in this Hardware Installation Manual.
This Hardware Installation Manual complements the relevant Siemens Configuration Manual.
Siemens strives continually to improve the quality of information provided in this Hardware
Installation Manual.
• If you find any mistakes or would like to offer suggestions about how this document could
be improved, contact the Siemens Service Center.
The warning notice system is explained on the rear of the inside front.
Text features
In addition to the notes that you must observe for your own personal safety as well as to
avoid material damage, in this document you will find the following text features:
Operating instructions
Handling instructions with a specified sequence start with the word "Procedure":
The individual handling steps are numbered.
1. Execute the operating instructions in the specified sequence.
❒
SIMOTICS M-1FE2 built-in motors
Hardware Installation Manual, 10/2021, A5E50074509B AB 3
Introduction
The square indicates the end of the operating instruction.
Operating instructions without a specified sequence are identified using a bullet point:
• Execute the operating instructions.
Enumerations
• Enumerations are identified by a bullet point without any additional symbols.
– Enumerations at the second level are hyphenated.
Notes
Notes are shown as follows:
Note
A Note is an important item of information about the product, handling of the product or the
relevant section of the document. Notes provide you with help or further suggestions/ideas.
More information
Information on the following topics is available at:
• Additional links to download documents
• Using documentation online (find and search in manuals / information)
More information (https://support.industry.siemens.com/cs/de/en/view/108998034)
If you have any questions regarding the technical documentation (e.g. suggestions,
corrections), please send an e-mail to the following address E-mail
(mailto:docu.motioncontrol@siemens.com).
Internet address for products
Products (http://www.siemens.com/motioncontrol)
SIMOTICS M-1FE2 built-in motors
4 Hardware Installation Manual, 10/2021, A5E50074509B AB
Introduction
mySupport
Extensive assistance and more information can be found under the following link:
My Support Links and Tools (https://support.industry.siemens.com/My/de/en/documentation)
You can individually compile your personal library, e.g. for your documentation based on
Siemens content, and adapt it for your own machine documentation.
To do so, click "My Documentation".
Note
If you want to use this function, you must register once.
Later, you can log on with your login data.
You can create your own personal library under "mySupport" using the following procedure.
Precondition
You have registered for and logged on to "Siemens Industry Online Support", hereinafter
referred to as "SIOS".
SIOS (https://support.industry.siemens.com/cs/de/en/)
Procedure for creating a personal library
1. Open SIOS and log on.
2. Enter the product you are looking for under "Search for product info" and press "Enter".
3. Select the doc. class you want, e.g. "Manual", under "Entry type".
4. Click on your desired manual under the entries.
5. Click on "Add to mySupport documentation".
6. Enter a title.
7. Press "OK".
❒
The selected manual can be found under "mySupport". To find further functions, click on the
icon located to the right of the document.
In this way, you can create your own library and quickly access your documentation.
Training
The following link provides information on SITRAIN - training from Siemens for products,
systems and automation engineering solutions:
SITRAIN (http://siemens.com/sitrain)
SIMOTICS M-1FE2 built-in motors
Hardware Installation Manual, 10/2021, A5E50074509B AB 5
Introduction
Technical Support
If you have any technical questions, contact Technical Support
(https://support.industry.siemens.com/cs/ww/en/ps).
To make a support request, proceed as follows:
Precondition
You have registered for and logged on to "Siemens Industry Online Support", abbreviated
"SIOS".
SIOS (https://support.industry.siemens.com/cs/de/en/)
Procedure
1. Click on "Your direct way to the Support Request" or follow the link Support Request
(https://support.industry.siemens.com/cs/de/en/my)
2. Follow the instructions in the online form.
❒
Websites of third parties
This document includes hyperlinks to websites of third-party companies. Siemens is not
responsible for and shall not be liable for these websites and is not responsible for the
content or information they provide. Siemens does not control the information on these
websites and is not responsible for the content and information provided there. The user
bears the risk for their use.
SIMOTICS M-1FE2 built-in motors
6 Hardware Installation Manual, 10/2021, A5E50074509B AB
Table of contents
Introduction ........................................................................................................................................... 3
1 Fundamental safety instructions ......................................................................................................... 11
1.1 General safety instructions ................................................................................................. 11
1.2 Equipment damage due to electric fields or electrostatic discharge ..................................... 16
1.3 Security information .......................................................................................................... 17
1.4 Residual risks of power drive systems ................................................................................. 18
2 Special safety notices for handling built-in motors ............................................................................. 19
3 Description ........................................................................................................................................... 21
3.1 Correct and intended use ................................................................................................... 21
3.2 Overview of the motors ..................................................................................................... 22
3.3 Technical features and system requirements for built-in motors.......................................... 25
3.3.1 Directives and standards .................................................................................................... 25
3.3.2 Technical features and ambient conditions ......................................................................... 27
3.3.2.1 Structure and characteristics of the synchronous version .................................................... 28
3.3.2.2 Design and characteristics of the asynchronous versions 1FE2....-.A... and 1FE2...-.C... ....... 31
3.3.3 Features, properties, and system preconditions .................................................................. 32
3.3.4 Version and operating modes of the motor in the synchronous version............................... 38
3.3.4.1 Operation on a power section ............................................................................................ 41
3.3.4.2 Operation on two power sections....................................................................................... 42
3.3.4.3 Conversion of the converter setting data ............................................................................ 43
3.3.5 Version and operating modes of the motor in the asynchronous version ............................. 48
3.4 Rating plate data................................................................................................................ 51
3.4.1 Rating plate details (type plate) of 1FE2 in synchronous version ......................................... 51
3.4.2 Rating plate details (type plate) of 1FE2 in asynchronous version, star connection .............. 52
3.4.3 Rating plate details (type plate) of 1FE2 in asynchronous version, star-delta connection ..... 53
3.5 Structure of the Article No.................................................................................................. 54
4 Motor components, characteristics and options ................................................................................. 57
4.1 Thermal motor protection .................................................................................................. 57
4.1.1 Thermal motor protection with temperature sensors (standard protection)......................... 58
4.1.2 Temperature evaluation using the PTC thermistor triplet (full motor protection) ................. 60
4.1.3 Temperature evaluation using NTC thermistors (universal protection, option)..................... 61
4.2 Cooling .............................................................................................................................. 62
4.2.1 Safety instructions ............................................................................................................. 62
4.2.2 Cooling circuit ................................................................................................................... 64
4.2.3 Configuring the cooling circuit ........................................................................................... 66
4.2.4 Volume flow and pressure drop.......................................................................................... 67
4.2.5 Cooling powers to be dissipated (power loss) ..................................................................... 69
4.2.6 Calculation of the cooling power to be dissipated (power loss) ........................................... 70
4.2.7 Coolant ............................................................................................................................. 72
SIMOTICS M-1FE2 built-in motors
Hardware Installation Manual, 10/2021, A5E50074509B AB 7
Table of contents
4.2.8 Commissioning the cooling circuit ..................................................................................... 75
4.3 Encoder system ................................................................................................................. 75
5 Preparing for use ................................................................................................................................. 77
5.1 Safety instructions for electromagnetic and permanent-magnetic fields ............................. 77
5.2 Shipping and packaging ..................................................................................................... 80
5.3 Transportation and storage ................................................................................................ 83
6 Mechanical mounting .......................................................................................................................... 87
6.1 Safety instructions ............................................................................................................. 87
6.2 Installation requirements ................................................................................................... 91
6.3 Installing/removing the rotor ............................................................................................. 92
6.3.1 Overview of installation methods for the rotors .................................................................. 92
6.3.2 Tools and resources ........................................................................................................... 94
6.3.3 Mounting preparations ...................................................................................................... 98
6.3.4 Mounting the rotor ............................................................................................................ 99
6.3.5 Compensating mechanical stresses and deformations of the spindle shaft ........................ 102
6.3.6 Balancing of rotors in synchronous version ....................................................................... 106
6.3.7 Balancing of rotors in asynchronous version ..................................................................... 111
6.3.8 Removing the rotor core with sleeve ................................................................................ 112
6.4 Installing the stator in the spindle housing ....................................................................... 115
6.4.1 Flow chart for the stator installation ................................................................................. 115
6.4.2 Mounting the stator without cooling jacket ...................................................................... 116
6.4.2.1 Production equipment, assembly tools and other resources .............................................. 116
6.4.2.2 Mounting the stator without cooling jacket ...................................................................... 117
6.4.3 Mounting the stator with cooling jacket ........................................................................... 120
6.4.3.1 Production equipment, assembly tools and other resources .............................................. 120
6.4.3.2 Preparation for installation ............................................................................................... 121
6.4.3.3 Mounting the stator with cooling jacket in the stator housing........................................... 123
6.5 Mounting the motor spindle ............................................................................................ 127
6.5.1 Preparation ...................................................................................................................... 127
6.5.2 Acting magnetic forces .................................................................................................... 127
6.5.3 Mounting the motor spindle ............................................................................................ 128
6.6 Setting up the motor spindle............................................................................................ 132
6.7 Permissible motor vibrations ............................................................................................ 133
7 Connection ........................................................................................................................................ 135
7.1 Connecting the cooling .................................................................................................... 135
7.1.1 Warning of the consequences of unqualified work ........................................................... 135
7.1.2 Safety instructions ........................................................................................................... 135
7.1.3 Connecting the water cooling system............................................................................... 137
7.2 Electrical connection ........................................................................................................ 139
7.2.1 Safety information ........................................................................................................... 139
7.2.2 High-voltage test ............................................................................................................. 139
7.2.3 Electrical equipment ........................................................................................................ 140
7.2.4 Notes on electrical connection ......................................................................................... 140
7.2.5 Notes on choosing the connecting leads .......................................................................... 141
SIMOTICS M-1FE2 built-in motors
8 Hardware Installation Manual, 10/2021, A5E50074509B AB
Table of contents
7.2.6 Cable cross-section, cable outer diameter and cable variant for synchronous versions ....... 142
7.2.7 Cable cross-section, cable outer diameter and cable variant for asynchronous versions ..... 144
7.2.8 Information on cable routing ........................................................................................... 146
7.2.9 Connecting the synchronous version ................................................................................ 146
7.2.9.1 Overview of connections with one power unit .................................................................. 148
7.2.9.2 Overview of connections with two power units ................................................................ 152
7.2.10 Connecting the asynchronous version .............................................................................. 155
7.2.11 Connection assignment of the encoder ............................................................................ 160
7.2.12 Recommended grounding ................................................................................................ 160
7.2.13 Signal connection and motor protection........................................................................... 161
8 Commissioning .................................................................................................................................. 165
8.1 Manufacturer declaration................................................................................................. 165
8.2 Safety instructions ........................................................................................................... 166
8.3 Checklist prior to commissioning ...................................................................................... 169
8.4 Test the insulation resistance ........................................................................................... 172
8.5 Commutation angle and pole position identification ......................................................... 173
8.5.1 Versions of the pole position identification (applies only to synchronous version) ............. 173
8.5.2 Determining the commutation angle (applies only to synchronous version) ...................... 174
8.6 Commissioning the cooling circuit.................................................................................... 175
8.7 Switching on and switching off ........................................................................................ 176
9 Operation ........................................................................................................................................... 177
9.1 Safety instructions ........................................................................................................... 177
9.2 Operation ........................................................................................................................ 179
9.3 Faults and how to resolve them ....................................................................................... 180
9.4 Stoppages ....................................................................................................................... 182
10 Service and maintenance .................................................................................................................. 183
10.1 Additional maintenance notice......................................................................................... 183
11 Decommissioning and disposal ......................................................................................................... 185
11.1 Safety instructions ........................................................................................................... 185
11.2 Decommissioning ............................................................................................................ 186
11.2.1 Preparing for dismantling ................................................................................................. 186
11.2.2 Disassembling the motor ................................................................................................. 186
11.3 Disposal ........................................................................................................................... 188
11.3.1 Guidelines for disposal ..................................................................................................... 188
11.3.2 Disposal of rotors in synchronous version ......................................................................... 189
11.3.3 Disposal of packaging ...................................................................................................... 190
12 Dimensional drawings ....................................................................................................................... 191
13 Spare parts ......................................................................................................................................... 193
A List of abbreviations .......................................................................................................................... 195
Index .................................................................................................................................................. 197
SIMOTICS M-1FE2 built-in motors
Hardware Installation Manual, 10/2021, A5E50074509B AB 9
Table of contents
SIMOTICS M-1FE2 built-in motors
10 Hardware Installation Manual, 10/2021, A5E50074509B AB
Fundamental safety instructions 1
1.1 General safety instructions
WARNING
Electric shock and danger to life due to other energy sources
Touching live components can result in death or severe injury.
• Only work on electrical devices when you are qualified for this job.
• Always observe the country-specific safety rules.
Generally, the following steps apply when establishing safety:
1. Prepare for disconnection. Notify all those who will be affected by the procedure.
2. Isolate the drive system from the power supply and take measures to prevent it being
switched back on again.
3. Wait until the discharge time specified on the warning labels has elapsed.
4. Check that there is no voltage between any of the power connections, and between any of
the power connections and the protective conductor connection.
5. Check whether the existing auxiliary supply circuits are de-energized.
6. Ensure that the motors cannot move.
7. Identify all other dangerous energy sources, e.g. compressed air, hydraulic systems, or
water. Switch the energy sources to a safe state.
8. Check that the correct drive system is completely locked.
After you have completed the work, restore the operational readiness in the inverse
sequence.
WARNING
Electric shock due to connection to an unsuitable power supply
When equipment is connected to an unsuitable power supply, exposed components may
carry a hazardous voltage. Contact with hazardous voltage can result in severe injury or
death.
• Only use power supplies that provide SELV (Safety Extra Low Voltage) or PELV-
(Protective Extra Low Voltage) output voltages for all connections and terminals of the
electronics modules.
SIMOTICS M-1FE2 built-in motors
Hardware Installation Manual, 10/2021, A5E50074509B AB 11
Fundamental safety instructions
1.1 General safety instructions
WARNING
Electric shock due to damaged motors or devices
Improper handling of motors or devices can damage them.
Hazardous voltages can be present at the enclosure or at exposed components on damaged
motors or devices.
• Ensure compliance with the limit values specified in the technical data during transport,
storage and operation.
• Do not use any damaged motors or devices.
WARNING
Electric shock due to unconnected cable shield
Hazardous touch voltages can occur through capacitive cross-coupling due to unconnected
cable shields.
• As a minimum, connect cable shields and the conductors of power cables that are not
used (e.g. brake cores) at one end at the grounded housing potential.
WARNING
Electric shock if there is no ground connection
For missing or incorrectly implemented protective conductor connection for devices with
protection class I, high voltages can be present at open, exposed parts, which when
touched, can result in death or severe injury.
• Ground the device in compliance with the applicable regulations.
WARNING
Arcing when a plug connection is opened during operation
Opening a plug connection when a system is operation can result in arcing that may cause
serious injury or death.
• Only open plug connections when the equipment is in a voltage-free state, unless it has
been explicitly stated that they can be opened in operation.
SIMOTICS M-1FE2 built-in motors
12 Hardware Installation Manual, 10/2021, A5E50074509B AB
Fundamental safety instructions
1.1 General safety instructions
NOTICE
Property damage due to loose power connections
Insufficient tightening torques or vibration can result in loose power connections. This can
result in damage due to fire, device defects or malfunctions.
• Tighten all power connections to the prescribed torque.
• Check all power connections at regular intervals, particularly after equipment has been
transported.
NOTICE
Damage to equipment due to unsuitable tightening tools.
Unsuitable tightening tools or fastening methods can damage the screws of the equipment.
• Be sure to only use screwdrivers which exactly match the heads of the screws.
• Tighten the screws with the torque specified in the technical documentation.
• Use a torque wrench or a mechanical precision nut runner with a dynamic torque sensor
and speed limitation system.
WARNING
Unexpected movement of machines caused by radio devices or mobile phones
Using radio devices or mobile telephones in the immediate vicinity of the components can
result in equipment malfunction. Malfunctions may impair the functional safety of machines
and can therefore put people in danger or lead to property damage.
• Therefore, if you move closer than 20 cm to the components, be sure to switch off radio
devices or mobile telephones.
• Use the "SIEMENS Industry Online Support app" only on equipment that has already been
switched off.
WARNING
Unrecognized dangers due to missing or illegible warning labels
Dangers might not be recognized if warning labels are missing or illegible. Unrecognized
dangers may cause accidents resulting in serious injury or death.
• Check that the warning labels are complete based on the documentation.
• Attach any missing warning labels to the components, where necessary in the national
language.
• Replace illegible warning labels.
SIMOTICS M-1FE2 built-in motors
Hardware Installation Manual, 10/2021, A5E50074509B AB 13
Fundamental safety instructions
1.1 General safety instructions
WARNING
Unexpected movement of machines caused by inactive safety functions
Inactive or non-adapted safety functions can trigger unexpected machine movements that
may result in serious injury or death.
• Observe the information in the appropriate product documentation before
commissioning.
• Carry out a safety inspection for functions relevant to safety on the entire system,
including all safety-related components.
• Ensure that the safety functions used in your drives and automation tasks are adjusted
and activated through appropriate parameterizing.
• Perform a function test.
• Only put your plant into live operation once you have guaranteed that the functions
relevant to safety are running correctly.
Note
Important safety notices for Safety Integrated functions
If you want to use Safety Integrated functions, you must observe the safety notices in the
Safety Integrated manuals.
WARNING
Active implant malfunctions due to electromagnetic fields
Electromagnetic fields (EMF) are generated by the operation of electrical power equipment,
such as transformers, converters, or motors. People with pacemakers or implants are at
particular risk in the immediate vicinity of this equipment.
• If this affects you, maintain the minimum distance to such equipment that is specified in
the "Intended use" chapter.
WARNING
Active implant malfunctions due to permanent-magnet fields
Even when switched off, electric motors with permanent magnets represent a potential risk
for persons with heart pacemakers or implants if they are close to converters/motors.
• If this affects you, maintain the minimum distance to such equipment that is specified in
the "Intended use" chapter.
• When transporting or storing permanent-magnet motors always use the original packing
materials with the warning labels attached.
• Clearly mark the storage locations with the appropriate warning labels.
• IATA regulations must be observed when transported by air.
SIMOTICS M-1FE2 built-in motors
14 Hardware Installation Manual, 10/2021, A5E50074509B AB
Fundamental safety instructions
1.1 General safety instructions
WARNING
Injury caused by moving or ejected parts
Contact with moving motor parts or drive output elements and the ejection of loose motor
parts (e.g. feather keys) out of the motor enclosure can result in severe injury or death.
• Remove any loose parts or secure them so that they cannot be flung out.
• Do not touch any moving parts.
• Safeguard all moving parts using the appropriate safety guards.
WARNING
Fire due to inadequate cooling
Inadequate cooling can cause the motor to overheat, resulting in death or severe injury as a
result of smoke and fire. This can also result in increased failures and reduced service lives of
motors.
• Comply with the specified cooling requirements for the motor.
WARNING
Fire due to incorrect operation of the motor
When incorrectly operated and in the case of a fault, the motor can overheat resulting in fire
and smoke. This can result in severe injury or death. Further, excessively high temperatures
destroy motor components and result in increased failures as well as shorter service lives of
motors.
• Operate the motor according to the relevant specifications.
• Only operate the motors in conjunction with effective temperature monitoring.
• Immediately switch off the motor if excessively high temperatures occur.
CAUTION
Burn injuries caused by hot surfaces
In operation, the motor can reach high temperatures, which can cause burns if touched.
• Mount the motor so that it is not accessible in operation.
Measures when maintenance is required:
• Allow the motor to cool down before starting any work.
• Use the appropriate personnel protection equipment, e.g. gloves.
SIMOTICS M-1FE2 built-in motors
Hardware Installation Manual, 10/2021, A5E50074509B AB 15
Fundamental safety instructions
1.2 Equipment damage due to electric fields or electrostatic discharge
1.2 Equipment damage due to electric fields or electrostatic
discharge
Electrostatic sensitive devices (ESD) are individual components, integrated circuits, modules
or devices that may be damaged by either electric fields or electrostatic discharge.
NOTICE
Equipment damage due to electric fields or electrostatic discharge
Electric fields or electrostatic discharge can cause malfunctions through damaged individual
components, integrated circuits, modules or devices.
• Only pack, store, transport and send electronic components, modules or devices in their
original packaging or in other suitable materials, e.g conductive foam rubber of
aluminum foil.
• Only touch components, modules and devices when you are grounded by one of the
following methods:
– Wearing an ESD wrist strap
– Wearing ESD shoes or ESD grounding straps in ESD areas with conductive flooring
• Only place electronic components, modules or devices on conductive surfaces (table
with ESD surface, conductive ESD foam, ESD packaging, ESD transport container).
SIMOTICS M-1FE2 built-in motors
16 Hardware Installation Manual, 10/2021, A5E50074509B AB
Fundamental safety instructions
1.3 Security information
1.3 Security information
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens’ products and solutions constitute one element of such a concept.
Customers are responsible for preventing unauthorized access to their plants, systems,
machines and networks. Such systems, machines and components should only be connected
to an enterprise network or the internet if and to the extent such a connection is necessary
and only when appropriate security measures (e.g. firewalls and/or network segmentation)
are in place.
For additional information on industrial security measures that may be implemented, please
visit
https://www.siemens.com/industrialsecurity (https://www.siemens.com/industrialsecurity).
Siemens’ products and solutions undergo continuous development to make them more
secure. Siemens strongly recommends that product updates are applied as soon as they are
available and that the latest product versions are used. Use of product versions that are no
longer supported, and failure to apply the latest updates may increase customer’s exposure to
cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS
Feed under
https://www.siemens.com/industrialsecurity
(https://new.siemens.com/global/en/products/services/cert.html#Subscriptions).
Further information is provided on the Internet:
Industrial Security Configuration Manual
(https://support.industry.siemens.com/cs/ww/en/view/108862708)
WARNING
Unsafe operating states resulting from software manipulation
Software manipulations, e.g. viruses, Trojans, or worms, can cause unsafe operating states
in your system that may lead to death, serious injury, and property damage.
• Keep the software up to date.
• Incorporate the automation and drive components into a holistic, state-of-the-art
industrial security concept for the installation or machine.
• Make sure that you include all installed products into the holistic industrial security
concept.
• Protect files stored on exchangeable storage media from malicious software by with
suitable protection measures, e.g. virus scanners.
• On completion of commissioning, check all security-related settings.
SIMOTICS M-1FE2 built-in motors
Hardware Installation Manual, 10/2021, A5E50074509B AB 17
Fundamental safety instructions
1.4 Residual risks of power drive systems
1.4 Residual risks of power drive systems
When assessing the machine- or system-related risk in accordance with the respective local
regulations (e.g., EC Machinery Directive), the machine manufacturer or system installer
must take into account the following residual risks emanating from the control and drive
components of a drive system:
1. Unintentional movements of driven machine or system components during commissioning,
operation, maintenance, and repairs caused by, for example,
– Hardware and/or software errors in the sensors, control system, actuators, and cables
and connections
– Response times of the control system and of the drive
– Operation and/or environmental conditions outside the specification
– Condensation/conductive contamination
– Parameterization, programming, cabling, and installation errors
– Use of wireless devices/mobile phones in the immediate vicinity of electronic
components
– External influences/damage
– X-ray, ionizing radiation and cosmic radiation
2. Unusually high temperatures, including open flames, as well as emissions of light, noise,
particles, gases, etc., can occur inside and outside the components under fault conditions
caused by, for example:
– Component failure
– Software errors
– Operation and/or environmental conditions outside the specification
– External influences/damage
3. Hazardous shock voltages caused by, for example:
– Component failure
– Influence during electrostatic charging
– Induction of voltages in moving motors
– Operation and/or environmental conditions outside the specification
– Condensation/conductive contamination
– External influences/damage
4. Electrical, magnetic and electromagnetic fields generated in operation that can pose a risk to
people with a pacemaker, implants or metal replacement joints, etc., if they are too close
5. Release of environmental pollutants or emissions as a result of improper operation of the
system and/or failure to dispose of components safely and correctly
6. Influence of network-connected communication systems, e.g. ripple-control transmitters or
data communication via the network
For more information about the residual risks of the drive system components, see the
relevant sections in the technical user documentation.
SIMOTICS M-1FE2 built-in motors
18 Hardware Installation Manual, 10/2021, A5E50074509B AB
Special safety notices for handling built-in motors 2
Components with permanent magnets
The synchronous version of the 1FE2 built-in motor contains permanent magnets in the
rotor.
WARNING
Danger to life and material damage when incorrectly used
If you do not use the motors correctly, there is a risk of death, severe injury and/or material
damage.
• Only use the motors for their intended purpose.
• Make sure that the conditions at the location of use comply with all the rating plate data.
• Make sure that the conditions at the location of use comply with the conditions specified
in this documentation. When necessary, take into account deviations regarding
approvals or country-specific regulations.
WARNING
Danger to life caused by magnetic and electrical fields to persons with active implants
Electric motors represent a danger for people with active implants who come close to the
motors.
• If you are an affected person, maintain a minimum separation of 500 mm to motors.
If you wish to use special versions and design variants whose specifications vary from the
motors described in this document, then contact your local Siemens office.
If you have any questions regarding the intended usage, please contact your local Siemens
office.
SIMOTICS M-1FE2 built-in motors
Hardware Installation Manual, 10/2021, A5E50074509B AB 19
Special safety notices for handling built-in motors
WARNING
Electrical shock hazard
Every movement of the rotor compared with the stator and vice versa induces a voltage at
the stator power connections.
When the motor is switched on, the stator power connections are also at a specific voltage.
If you use defective cable ports, you could suffer an electric shock.
• Only mount and remove the electrical components if you are qualified to do so.
• Any work carried out at the motor must always be done with the system in a no-voltage
condition.
• Do not touch the cable ports. Correctly connect the stator power connections, or insulate
them properly.
• Do not disconnect the power connections when the stator is under voltage (live).
• Only use the specific power cables intended for the purpose.
• First connect the protective conductor (PE).
• Connect the cable shield through a wide area.
• First connect the power cable to the stator before you connect the power cable to the
inverter.
• First disconnect the connection to the inverter before you disconnect the power
connection to the stator.
• Disconnect the protective conductor PE last.
Material damage caused by strong magnetic fields
NOTICE
Data loss caused by strong magnetic fields
If you are close to the rotor (< 100 mm) any magnetic or electronic data medium as well as
electronic devices that you are carrying can be destroyed. For example, credit cards, USB
sticks, floppy disks and watches are at risk.
• Do not carry any magnetic/electronic data media and no electronic devices when you are
close to a rotor!
SIMOTICS M-1FE2 built-in motors
20 Hardware Installation Manual, 10/2021, A5E50074509B AB
Description 3
3.1 Correct and intended use
WARNING
Danger to life and material damage when incorrectly used
If you do not use the motors correctly, there is a risk of death, severe injury and/or material
damage.
• Only use the motors for their intended purpose.
• Make sure that the conditions at the location of use comply with all the rating plate data.
• Make sure that the conditions at the location of use comply with the conditions specified
in this documentation. When necessary, take into account deviations regarding
approvals or country-specific regulations.
WARNING
Danger to life caused by magnetic and electrical fields to persons with active implantsПоказано початок документа. Повний текст — у PDF за посиланням вище.