SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

Main spindle motors for SIMODRIVE 611, 1PH7 asynchronous motors SH 100 to SH 225

Вид документаКаталожна сторінка
ВиробникSIEMENS
Моделі1PH7101-7NF, 1PH7103-7ND, 1PH7103-7NF, 1PH7103-7NG, 1PH7105-7NF, 1PH7107-7ND, 1PH7107-7NF, 1PH7107-7NG
Група обладнанняelectrical
Мова документаанглійська
Розмір файлу0.3 МБ

Про документ

Forced-ventilated asynchronous main spindle motors in shaft heights SH 100 to SH 225 for operation with the SIMODRIVE 611 converter system. Available as solid-shaft core type (SH 100 to SH 160) and standard type motors with a wide choice of type of construction, bearing version and options via order-code suffixes.

Ключові дані

Shaft heightsSH 100 to SH 225
StandardIEC 60034-1
Degree of protectionIP55, fan IP54
Encoder systemIncremental encoder sin/cos 1 Vpp without C and D tracks (SH 180: 2 048 S/R)
Duty typesS1, S6-60 %, S6-40 %, S2-30 min
Rated power S13.7 … 100 kW
Rated speed500 … 2 500 rpm
Maximum speed nmax5 500 … 12 000 rpm

Застосування

  • Main spindle drives on machine tools, operated with SIMODRIVE 611 power modules
  • ZF gearbox mounting prepared versions (see Gearboxes selection)

Особливості

  • Forced ventilation by external fan unit (heavy-gauge threaded or metric cable entry)
  • Incremental encoder sin/cos 1 Vpp feedback
  • Duty types S1, S6-60 %, S6-40 %, S2-30 min
  • Types of construction IM B3 / IM B35 variants incl. hoisting systems and flange D = 450 mm (only 1PH7184)
  • Bearing versions for coupling/belt output, increased cantilever force and increased maximum speed
  • Vibration magnitude grades R, S, SR; shaft sealing ring option (not possible with increased maximum speed)
  • Paint finish unpainted, primed, anthracite, anthracite two coats

Технічні дані

Parameter Value
Motor series 1PH7 asynchronous motor, solid shaft
Shaft heights SH 100, SH 132, SH 160, SH 180, SH 225
Standard IEC 60034-1
Ventilation Forced ventilation (external fan unit)
Rated speeds (nrated) 500 … 2 500 rpm depending on model
Continuous speed, max., standard type SH 100 5 500 rpm (bearing version for coupling/belt output); 10 000 rpm (bearing version for increased maximum speed)
Continuous speed, max., standard type SH 132 4 500 rpm; 8 500 rpm
Continuous speed, max., standard type SH 160 3 700 rpm; 7 000 rpm
Continuous speed, max., standard type SH 180 3 000 rpm; 4 500 rpm; 5 000 rpm
Continuous speed, max., standard type SH 225 2 700 rpm; 3 600 rpm; 4 500 rpm
Maximum speed nmax, standard type 12 000 rpm (SH 100), 10 000 rpm (SH 132), 8 000 rpm (SH 160), 7 000 rpm (SH 180), 5 500 rpm (SH 225)
Maximum speed nmax, core type 9 000 rpm (SH 100), 8 000 rpm (SH 132), 6 500 rpm (SH 160)
Rated power S1 3.7 … 100 kW
Rated power S6-60 % / S6-40 % / S2-30 min per duty table, e.g. SH 225: S6-40 % up to 140 kW (1PH7224-.NF)
Rated torque Mrated 23.6 … 750 Nm
Moment of inertia J 0.017 … 1.48 kgm2
Weight approx. 43 … 650 kg
Encoder system Incremental encoder sin/cos 1 Vpp without C and D tracks; SH 180: 2 048 S/R
Type of construction IM B3 (IM V5, IM V6), IM B5 (IM V1, IM V3), IM B35 (IM V15, IM V35); hoisting system and flange D = 450 mm variants (SH 180/225)
Terminal box/cable entry Top/right, Top/DE, Top/NDE, Top/left
Degree of protection IP55, fan IP54
Seal –, or DE flange with shaft sealing ring
Paint finish Unpainted, Primed, Anthracite, Anthracite two coats
Blow-out direction Axial (A/B/D/K/J), Right (C/J for SH 180/225)

Варіанти замовлення

Selection and ordering data per motor type, e.g. 1PH7103 - 7 ND02 - 0C (core type) and 1PH7103 - 7 ND 77 - 07 77 (standard type). Code positions cover fan unit (2/7), encoder system (N), terminal box position, type of construction, bearing/vibration grade, shaft extension/balancing/blow-out direction, seal and paint finish. SIMODRIVE 611 power module rated output currents: see Converter system.

Допуски та стандарти

  • IEC 60034-1

Текст документа

                                                                        © Siemens AG 2009

                Asynchronous motors
      Main spindle motors for SIMODRIVE 611
      1PH7 core type motors
      SH 100 to SH 160

    ■ Selection and ordering data
       Shaft    Rated    Continuous               Speed, max.1)         Rated power                                            1PH7 asynchronous motor
       height   speed    speed, max.                                    for duty type                                          with solid shaft
                                                                        in accordance with IEC 60034-1                         Forced ventilation
                                                                                                                               Core type


       SH       nrated   nS1 cont.2) nS1 cont.3) nmax       nmax4)      Prated

                                                                        S1          S6-60 %        S6-40 %       S2-30 min
                rpm      rpm        rpm           rpm       rpm         kW          kW             kW            kW            Order No.
                                                                        (HP)        (HP)           (HP)          (HP)

       100      2 000    5 500      –             9 000     –            7 (9)        8.5 (11.4)   10 (13)        9.25 (12.4) 1PH7103 - 7 NG02 - 0C 7 7

                1 500    5 500      –             9 000     –            9 (12)     11 (14.8)      13 (17)       12 (16)       1PH7107 - 7 NF02 - 0C 7 7

       132      1 000    4 500      –             8 000     –           12 (16)     15 (20)        18.5 (24.8)   16 (21)       1PH7133 - 7 ND02 - 0C 7 7
                2 000                                                   20 (27)     25 (34)        30 (40)       27.5 (36.9)   1PH7133 - 7 NG02 - 0C 7 7

                1 000    4 500      –             8 000     –           17 (23)     20.5 (27.5)    25 (34)       22.5 (30.2)   1PH7137 - 7 ND02 - 0C 7 7
                2 000                                                   28 (38)     35 (47)        43 (58)       39 (52)       1PH7137 - 7 NG02 - 0C7 7

       160      1 000    3 700      –             6 500     –           22 (30)     27 (36)        33 (44)       30 (40)       1PH7163 - 7 ND03 - 0C 7 7
                1 500                                                   30 (40)     37 (50)        45 (60)       41 (55)       1PH7163 - 7 N F03 - 0C7 7

                1 500    3 700       –            6 500     –           37 (50)     46 (62)        56 (75)       51 (68)       1PH7167 - 7 NF03 - 0C 7 7

       Fans:                             External fan unit, heavy-gauge threaded cable entry in terminal box                               2
                                         External fan unit, metric cable entry in terminal box                                             7

       Encoder system:                   Incremental encoder sin/cos 1 Vpp without C and D tracks                                              N

       Type of construction:5)           IM B5 (IM V1, IM V3)                                                                                      2
                                         IM B35 (IM V15, IM V35)6)                                                                                 3

       Shaft extension DE:5)             Balancing:             Direction of air flow (fan):        Blow-out direction:

7      Fitted key
       Plain shaft
                                         Half-key
                                         –
                                                                DE → NDE
                                                                DE → NDE
                                                                                                    Axial
                                                                                                    Axial
                                                                                                                                                       A
                                                                                                                                                       J

       Degree of protection:             Paint finish:
       IP55, fan IP54                    Unpainted                                                                                                         0
       IP55, fan IP54                    Anthracite                                                                                                        3

      To select the type of construction, see Selection guides.




        7/6        Siemens NC 60 · 2009
                                                                            © Siemens AG 2009



NC60_en_Kap07_04.fm Seite 7 Sonntag, 26. Juli 2009 5:34 17


                                                                           © Siemens AG 2009

                                                                                                         Asynchronous motors
                                                                                        Main spindle motors for SIMODRIVE 611
                                                                                                                                   1PH7 core type motors
                                                                                                                                        SH 100 to SH 160

    ■ Selection and ordering data
        Motor type              Rated           Moment of       Weight,        Rated current                              SIMODRIVE 611 power module
        (continued)             torque          inertia         approx.        for duty type
                                                                               in accordance with IEC 60034-1             Rated
                                                                                                                          output
                                                                                                                          current7)

                                Mrated          J               m              Irated                                     Irated

                                                                               S1        S6-60 % S6-40 % S2-30 min S1
                                Nm              kgm2            kg             A         A        A          A            A            Order No.
                                (lbf -ft)       (lbf -in-s2)    (lb)

        1PH7103-.NG02-....        33.4 (24.6)   0.017 (0.148)    43 (95)       17.5      20.5       23.5      21.5        24           For ordering data,
                                                                                                                                       see Converter system
        1PH7107-.NF02-....        57.3 (42.2)   0.029 (0.252)    64 (141)      23.5      27.5       31        29          24

        1PH7133-.ND02-....      114.6 (84.5)    0.076 (0.66)    102 (225)      30        36         43        37.5        30
        1PH7133-.NG02-....       95.5 (70.4)    0.076 (0.66)    102 (225)      45        54         63        59          45

        1PH7137-.ND02-....      162.3 (119.6) 0.109 (0.946) 129 (284)          43        50         60        54          45
        1PH7137-.NG02-....      133.7 (98.5) 0.109 (0.946) 129 (284)           60        73         87        80          60

        1PH7163-.ND03-....      210.1 (154.8) 0.19 (1.649)      198 (437)      55        65        77         71          60
        1PH7163-.NF03-....      191.0 (140.8) 0.19 (1.649)      198 (437)      72        86       102         94          85

        1PH7167-.NF03-....      235.5 (173.6) 0.23 (1.996)      231 (509)      82        97       115        104          85




                                                                                                                                                              7




                                                                                        1PH7 motor (SH 100 to SH 160)




        1)   For continuous duty (with 30 % nmax, 60 % 2/3 nmax, 10 % standstill) for a duty cycle time of 10 min. For maintenance intervals for motors and
             components, see 1PH Motors Configuration Manual.
        2)   Bearing version for coupling/belt output.
        3)   Bearing version for increased maximum speed.
        4)   Version for increased maximum speed only possible with vibration magnitude grade SR. The following option is not possible: Shaft seal.
        5)   The following motor versions are required for ZF gearbox mounting prepared (see Gearboxes for gear selection):
             Shaft with fitted key and full-key balancing.
        6)   Motors of shaft height 160 and higher require foot support.
        7)   With default setting of the pulse frequency.


                                                                                                                     Siemens NC
                                                                                                                           Siemens
                                                                                                                                60 · NC
                                                                                                                                     2009
                                                                                                                                        60 ·
                                                                                                                                          (07.09)
                                                                                                                                             2009       7/7
                                                                        © Siemens AG 2009

                Asynchronous motors
      Main spindle motors for SIMODRIVE 611
      1PH7 standard type motors
      SH 100

    ■ Selection and ordering data
       Shaft    Rated     Continuous             Speed, max.1)        Rated power                                                  1PH7 asynchronous motor
       height   speed     speed, max.                                 for duty type                                                with solid shaft
                                                                      in accordance with IEC 60034-1                               Forced ventilation
                                                                                                                                   Standard type


       SH       nrated    nS1 cont.2) nS1 cont.3) nmax      nmax4)    Prated

                                                                      S1              S6-60 %        S6-40 %        S2-30 min
                rpm       rpm         rpm        rpm        rpm       kW              kW             kW             kW             Order No.
                                                                      (HP)            (HP)           (HP)           (HP)

       100      1 500     5 500       10 000     9 000      12 000     3.7 (5)          4.5 (6)       5.25 (7.04)    4.9 (6.6)     1PH7101 - 7 NF 7 7 - 07 7 7

                1 000     5 500       10 000     9 000      12 000     3.7 (5)          4.5 (6)       5.25 (7.04)    4.7 (6.3)     1PH7103 - 7 ND 7 7 - 0 7 7 7
                1 500                                                  5.5 (7.4)        6.7 (9)       7.7 (10.3)     7 (9.4)       1PH7103 - 7 NF 7 7 - 07 7 7
                2 000                                                  7 (9)            8.5 (11.4)   10 (13)         9.25 (12.4)   1PH7103 - 7 NG7 7 - 07 7 7

                1 500     5 500       10 000     9 000      12 000     7 (9)            8.5 (11.4)   10 (13)         9.25 (12.4)   1PH7105 - 7 NF 7 7 - 07 7 7

                1 000     5 500       10 000     9 000      12 000     6.25 (8.38) 7.5 (10)           8.8 (11.8)     7.75 (10.39) 1PH7107 - 7 ND 7 7 - 0 7 7 7
                1 500                                                  9 (12)      11 (15)           13 (17)        12 (16)       1PH7107 - 7 NF 7 7 - 07 7 7
                2 000                                                 10.5 (14)    12.5 (17)         14.5 (19.4)    13.5 (18.1)   1PH7107 - 7 NG7 7 - 07 7 7

       Fans:                    External fan unit, heavy-gauge threaded cable entry in terminal box                                            2
                                External fan unit, metric cable entry in terminal box                                                          7

       Encoder system:          Incremental encoder sin/cos 1 Vpp without C and D tracks                                                           N

       Terminal box/            Top/right                                                                                                              0
       Cable entry:             Top/NDE                                                                                                                2
                                Top/left                                                                                                               3

       Type of                  IM B3 (IM V5, IM V6)                                                                                                       0
       construction:5)          IM B5 (IM V1, IM V3)                                                                                                       2
                                IM B35 (IM V15, IM V35)                                                                                                    3
7      Bearing version for:                    Vibration magnitude:              Shaft and flange accuracy:
       Coupling/belt output                    Grade R                           Tolerance R                                                                   B
       Coupling/belt output                    Grade S                           Tolerance R                                                                   C
       Coupling/belt output                    Grade SR                          Tolerance R                                                                   D
       Increased speed                         Grade SR                          Tolerance R                                                                   L
       (coupling/belt output)

       Shaft extension DE:5)                   Balancing:                        Direction of air flow (fan):         Blow-out direction:
       Fitted key                              Half-key                          DE → NDE                             Axial                                        A
       Fitted key                              Half-key                          NDE → DE                             Axial                                        B
       Fitted key                              Full-key                          DE → NDE                             Axial                                        C
       Fitted key                              Full-key                          NDE → DE                             Axial                                        D
       Plain shaft                             –                                 DE → NDE                             Axial                                        J
       Plain shaft                             –                                 NDE → DE                             Axial                                        K

       Degree of protection:                   Seal:                             Paint finish:
       IP55, fan IP54                          –                                 Unpainted                                                                             0
       IP55, fan IP54                          DE flange with                    Unpainted                                                                             2
                                               shaft sealing ring6)
       IP55, fan IP54                          –                                 Anthracite                                                                            3
       IP55, fan IP54                          DE flange with                    Anthracite                                                                            5
                                               shaft sealing ring6)
       IP55, fan IP54                          –                                 Anthracite, two coats                                                                 6
       IP55, fan IP54                          DE flange with                    Anthracite, two coats                                                                 8
                                               shaft sealing ring6)

      To select the type of construction and the degree of protection, see Selection guides.




         7/8        Siemens NC 60 · 2009
                                                                          © Siemens AG 2009



NC60_en_Kap07_04.fm Seite 9 Sonntag, 26. Juli 2009 5:38 17


                                                                         © Siemens AG 2009

                                                                                                          Asynchronous motors
                                                                                       Main spindle motors for SIMODRIVE 611
                                                                                                                        1PH7 standard type motors
                                                                                                                                           SH 100

    ■ Selection and ordering data
        Motor type              Rated           Moment of      Weight,        Rated current                              SIMODRIVE 611 power module
        (continued)             torque          inertia        approx.        for duty type
                                                                              in accordance with IEC 60034-1             Rated
                                                                                                                         output
                                                                                                                         current7)

                                Mrated          J              m              Irated                                     Irated

                                                                              S1        S6-60 % S6-40 % S2-30 min S1
                                Nm              kgm2           kg             A         A         A          A           A           Order No.
                                (lbf -ft)       (lbf -in-s2)   (lb)

        1PH7101-.NF...          23.6 (17.4)     0.017 (0.150) 43 (95)         10        11.5       12.5      12          24          For ordering data,
                                                                                                                                     see Converter system
        1PH7103-.ND...          35.3 (26)       0.017 (0.150) 43 (95)         10        11.5       13        12          24
        1PH7103-.N F...         35.0 (25.8)     0.017 (0.150) 43 (95)         13        16         18        16.5        24
        1PH7103-.NG...          33.4 (24.6)     0.017 (0.150) 43 (95)         17.5      20.5       23.5      21.5        24

        1PH7105-.N F...         44.6 (32.9)     0.029 (0.257) 64 (141)        17.5      21         23.5      22          24

        1PH7107-.ND...          59.7 (44)       0.029 (0.257) 64 (141)        17.5      20.5       23        21          24
        1PH7107-.N F...         57.3 (42.2)     0.029 (0.257) 64 (141)        23.5      27.5       31        29          24
        1PH7107-.NG...          50.1 (36.9)     0.029 (0.257) 64 (141)        26        28.5       33        31          30




                                                                                                                                                                 7




                                                                                       1PH7 motor (SH 100 to SH 160)




        1)   For continuous duty (with 30 % nmax, 60 % 2/3 nmax, 10 % standstill) for a duty cycle time of 10 min. For maintenance intervals for motors and
             components, see the 1PH Motors Configuration Manual.
        2)   Bearing version for coupling/belt output.
        3)   Bearing version for increased maximum speed.
        4)   Version for increased maximum speed only possible with vibration magnitude grade SR. The following option is not possible: Shaft sealing ring.
        5)   The following motor versions are required for ZF gearbox mounting prepared (see Gearboxes for gear selection):
             • Types of construction IM B5 or IM B35
             • Shaft with fitted key and full-key balancing.
        6)   Only appropriate if the sealing ring is occasionally lubricated with oil spray/mist. A sealing ring is not possible with increased maximum speed.
        7)   With default setting of the pulse frequency.


                                                                                                                    Siemens NC
                                                                                                                          Siemens
                                                                                                                               60 · NC
                                                                                                                                    2009
                                                                                                                                       60 ·
                                                                                                                                         (07.09)
                                                                                                                                            2009        7/9
                                                                         © Siemens AG 2009

                Asynchronous motors
      Main spindle motors for SIMODRIVE 611
      1PH7 standard type motors
      SH 132

    ■ Selection and ordering data
       Shaft    Rated     Continuous              Speed, max.1)        Rated power                                               1PH7 asynchronous motor
       height   speed     speed, max.                                  for duty type                                             with solid shaft
                                                                       in accordance with IEC 60034-1                            Forced ventilation
                                                                                                                                 Standard type


       SH       nrated    nS1 cont.2) nS1 cont.3) nmax       nmax4)    Prated

                                                                       S1             S6-60 %        S6-40 %       S2-30 min
                rpm       rpm         rpm         rpm        rpm       kW             kW             kW            kW            Order No.
                                                                       (HP)           (HP)           (HP)          (HP)

       132      1 500     4 500         8 500     8 000      10 000    11 (15)        13.5 (18.1)    16.5 (22.1)   15 (20)       1PH7131 - 7 NF 7 7 - 07 7 7

                1 000     4 500         8 500     8 000      10 000    12 (16)        15 (20)        18.5 (24.8)   16 (22)       1PH7133 - 7 ND 7 7 - 07 7 7
                1 500                                                  15 (20)        18.5 (24.8)    23 (31)       20.5 (27.5)   1PH7133 - 7 N F 7 7 - 07 7 7
                2 000                                                  20 (27)        25 (34)        30 (40)       27.5 (36.9)   1PH7133 - 7 N G7 7 - 07 7 7

                1 500     4 500         8 500     8 000      10 000    18.5 (24.8)    23 (31)        28 (38)       25.5 (34.2)   1PH7135 - 7 NF 7 7 - 07 7 7

                1 000     4 500         8 500     8 000      10 000    17 (23)        20.5 (27.5)    25 (34)       22.5 (30.2)   1PH7137 - 7 N D 7 7 - 0 7 7 7
                1 500                                                  22 (30)        27.5 (36.9)    33 (44)       30 (40)       1PH7137 - 7 NF 7 7 - 07 7 7
                2 000                                                  28 (38)        35 (47)        43 (58)       39 (52)       1PH7137 - 7 NG7 7 - 07 7 7

       Fans:                    External fan unit, heavy-gauge threaded cable entry in terminal box                                          2
                                External fan unit, metric cable entry in terminal box                                                        7

       Encoder system:          Incremental encoder sin/cos 1 Vpp without C and D tracks                                                         N

       Terminal box/            Top/right                                                                                                            0
       Cable entry:             Top/NDE                                                                                                              2
                                Top/left                                                                                                             3

       Type of                  IM B3 (IM V5, IM V6)                                                                                                     0
       construction:5)          IM B5 (IM V1, IM V3)                                                                                                     2
                                IM B35 (IM V15, IM V35)                                                                                                  3
7      Bearing version for:                     Vibration magnitude:             Shaft and flange accuracy:
       Coupling/belt output                     Grade R                          Tolerance R                                                                 B
       Coupling/belt output                     Grade S                          Tolerance R                                                                 C
       Coupling/belt output                     Grade SR                         Tolerance R                                                                 D
       Increased speed                          Grade SR                         Tolerance R                                                                 L
       (coupling/belt output)

       Shaft extension DE:5)                    Balancing:                       Direction of air flow (fan):        Blow-out direction:
       Fitted key                               Half-key                         DE → NDE                            Axial                                       A
       Fitted key                               Half-key                         NDE → DE                            Axial                                       B
       Fitted key                               Full-key                         DE → NDE                            Axial                                       C
       Fitted key                               Full-key                         NDE → DE                            Axial                                       D
       Plain shaft                              –                                DE → NDE                            Axial                                       J
       Plain shaft                              –                                NDE → DE                            Axial                                       K

       Degree of protection:                    Seal:                            Paint finish:
       IP55, fan IP54                           –                                Unpainted                                                                           0
       IP55, fan IP54                           DE flange with                   Unpainted                                                                           2
                                                shaft sealing ring6)
       IP55, fan IP54                           –                                Anthracite                                                                          3
       IP55, fan IP54                           DE flange with                   Anthracite                                                                          5
                                                shaft sealing ring6)
       IP55, fan IP54                           –                                Anthracite, two coats                                                               6
       IP55, fan IP54                           DE flange with                   Anthracite, two coats                                                               8
                                                shaft sealing ring6)

      To select the type of construction and the degree of protection, see Selection guides.




        7/10        Siemens NC 60 · 2009
                                                                          © Siemens AG 2009



NC60_en_Kap07_04.fm Seite 11 Sonntag, 26. Juli 2009 5:39 17


                                                                         © Siemens AG 2009

                                                                                                       Asynchronous motors
                                                                                       Main spindle motors for SIMODRIVE 611
                                                                                                                        1PH7 standard type motors
                                                                                                                                           SH 132

    ■ Selection and ordering data
        Motor type              Rated           Moment of      Weight,        Rated current                              SIMODRIVE 611 power module
        (continued)             torque          inertia        approx.        for duty type
                                                                              in accordance with IEC 60034-1             Rated
                                                                                                                         output
                                                                                                                         current7)

                                Mrated          J              m              Irated                                     Irated

                                                                              S1        S6-60 % S6-40 % S2-30 min S1
                                Nm              kgm2           kg             A         A         A          A           A           Order No.
                                (lbf -ft)       (lbf -in-s2)   (lb)

        1PH7131-.NF...            70.0 (51.6)   0.076 (0.673) 102 (225)       24        29        34         31.5        24          For ordering data,
                                                                                                                                     see Converter system
        1PH7133-.ND...           114.6 (84.5)   0.076 (0.673) 102 (225)       30        36        43         37.5        30
        1PH7133-.NF...            95.5 (70.4)   0.076 (0.673) 102 (225)       34        41        49         43.5        45
        1PH7133-.NG...            95.5 (70.4)   0.076 (0.673) 102 (225)       45        54        63         59          45

        1PH7135-.NF...           117.8 (86.8)   0.109 (0.965) 129 (284)       42        50        58         54          45

        1PH7137-.ND...           162.3 (119.6) 0.109 (0.965) 129 (284)        43        50        60         54          45
        1PH7137-.NF...           140.1 (103.3) 0.109 (0.965) 129 (284)        57        68        79         73          60
        1PH7137-.NG...           133.7 (98.5) 0.109 (0.965) 129 (284)         60        73        87         80          60




                                                                                                                                                                 7




                                                                                       1PH7 motor (SH 100 to SH 160)




        1)   For continuous duty (with 30 % nmax, 60 % 2/3 nmax, 10 % standstill) for a duty cycle time of 10 min. For maintenance intervals for motors and
             components, see the 1PH Motors Configuration Manual.
        2)   Bearing version for coupling/belt output.
        3)   Bearing version for increased maximum speed.
        4)   Version for increased maximum speed only possible with vibration magnitude grade SR. The following option is not possible: Shaft sealing ring.
        5)   The following motor versions are required for ZF gearbox mounting prepared (see Gearboxes for gear selection):
             • Types of construction IM B5 or IM B35
             • Shaft with fitted key and full-key balancing.
        6)   Only appropriate if the sealing ring is occasionally lubricated with oil spray/mist. A sealing ring is not possible with increased maximum speed.
        7)   With default setting of the pulse frequency.


                                                                                                                    Siemens NC
                                                                                                                          Siemens
                                                                                                                               60 · NC
                                                                                                                                    2009
                                                                                                                                       60 ·
                                                                                                                                         (07.09)
                                                                                                                                            2009        7/11
                                                                        © Siemens AG 2009

                Asynchronous motors
      Main spindle motors for SIMODRIVE 611
      1PH7 standard type motors
      SH 160

    ■ Selection and ordering data
       Shaft    Rated     Continuous             Speed, max.1)        Rated power                                            1PH7 asynchronous motor
       height   speed     speed, max.                                 for duty type                                          with solid shaft
                                                                      in accordance with IEC 60034-1                         Forced ventilation
                                                                                                                             Standard type


       SH       nrated    nS1 cont.2) nS1 cont.3) nmax      nmax4)    Prated

                                                                      S1             S6-60 %        S6-40 %    S2-30 min
                rpm       rpm         rpm        rpm        rpm       kW             kW             kW         kW            Order No.
                                                                      (HP)           (HP)           (HP)       (HP)

       160        500     3 700        7 000     6 500      8 000     12 (16)        15 (20)        18 (24)    16.5 (22.1)   1PH7163 - 7 N B 7 7 - 07 7 7
                1 000                                                 22 (30)        27 (36)        33 (44)    30 (40)       1PH7163 - 7 N D 7 7 - 07 7 7
                1 500                                                 30 (40)        37 (50)        45 (60)    41 (55)       1PH7163 - 7 N F 7 7 - 0 7 7 7
                2 000                                                 36 (48)        44 (59)        52 (70)    48 (64)       1PH7163 - 7 N G7 7 - 07 7 7

                  500     3 700        7 000     6 500      8 000     16 (21)        19.5 (26.2)    24 (32)    21.5 (28.8)   1PH7167 - 7 N B 7 7 - 07 7 7
                1 000                                                 28 (38)        34.5 (46.3)    42 (56)    38 (51)       1PH7167 - 7 N D 7 7 - 07 7 7
                1 500                                                 37 (50)        46 (62)        56 (75)    51 (68)       1PH7167 - 7 N F 7 7 - 07 7 7
                2 000                                                 41 (55)        51 (69)        61 (81)    56 (75)       1PH7167 - 7 N G7 7 - 07 7 7

       Fans:                    External fan unit, heavy-gauge threaded cable entry in terminal box                                      2
                                External fan unit, metric cable entry in terminal box                                                    7

       Encoder system:          Incremental encoder sin/cos 1 Vpp without C and D tracks                                                     N

       Terminal box/            Top/right                                                                                                        0
       Cable entry:             Top/NDE                                                                                                          2
                                Top/left                                                                                                         3

       Type of                  IM B3 (IM V5, IM V6)                                                                                                 0
       construction:5)          IM B35 (IM V15, IM V35)7)                                                                                            3



7
       Bearing version for:                    Vibration magnitude:             Shaft and flange accuracy:
       Coupling/belt output                    Grade R                          Tolerance R                                                              B
       Coupling/belt output                    Grade S                          Tolerance R                                                              C
       Coupling/belt output                    Grade SR                         Tolerance R                                                              D
       Increased speed                         Grade SR                         Tolerance R                                                              L
       (coupling/belt output)

       Shaft extension DE:5)                   Balancing:                       Direction of air flow (fan):     Blow-out direction:
       Fitted key                              Half-key                         DE → NDE                         Axial                                       A
       Fitted key                              Half-key                         NDE → DE                         Axial                                       B
       Fitted key                              Full-key                         DE → NDE                         Axial                                       C
       Fitted key                              Full-key                         NDE → DE                         Axial                                       D
       Plain shaft                             –                                DE → NDE                         Axial                                       J
       Plain shaft                             –                                NDE → DE                         Axial                                       K

       Degree of protection:                   Seal:                            Paint finish:
       IP55, fan IP54                          –                                Unpainted                                                                        0
       IP55, fan IP54                          DE flange with                   Unpainted                                                                        2
                                               shaft sealing ring6)
       IP55, fan IP54                          –                                Anthracite                                                                       3
       IP55, fan IP54                          DE flange with                   Anthracite                                                                       5
                                               shaft sealing ring6)
       IP55, fan IP54                          –                                Anthracite, two coats                                                            6
       IP55, fan IP54                          DE flange with                   Anthracite, two coats                                                            8
                                               shaft sealing ring6)

      To select the type of construction and the degree of protection, see Selection guides.




        7/12        Siemens NC 60 · 2009
                                                                            © Siemens AG 2009



NC60_en_Kap07_04.fm Seite 13 Sonntag, 26. Juli 2009 5:41 17


                                                                          © Siemens AG 2009

                                                                                                         Asynchronous motors
                                                                                        Main spindle motors for SIMODRIVE 611
                                                                                                                        1PH7 standard type motors
                                                                                                                                           SH 160

    ■ Selection and ordering data
        Motor type              Rated            Moment of      Weight,        Rated current                             SIMODRIVE 611 power module
        (continued)             torque           inertia        approx.        for duty type
                                                                               in accordance with IEC 60034-1            Rated
                                                                                                                         output
                                                                                                                         current8)

                                Mrated           J              m              Irated                                    Irated

                                                                               S1        S6-60 % S6-40 % S2-30 min S1
                                Nm               kgm2           kg             A         A         A         A           A           Order No.
                                (lbf -ft)        (lbf -in-s2)   (lb)

        1PH7163-.NB...           229.2 (168.9)   0.19 (1.682)   198 (437)      30         36        42        39           30        For ordering data,
        1PH7163-.ND...           210.1 (154.8)   0.19 (1.682)   198 (437)      55         65        77        71           60        see Converter system
        1PH7163-.NF...           191.0 (140.8)   0.19 (1.682)   198 (437)      72         86       102        94           85
        1PH7163-.NG...           171.9 (126.7)   0.19 (1.682)   198 (437)      85        100       114       107           85

        1PH7167-.NB...           305.5 (225.2)   0.23 (2.036)   231 (509)      37         44        53        48          45
        1PH7167-.ND...           267.4 (197.1)   0.23 (2.036)   231 (509)      71         85       100        92          85
        1PH7167-.NF...           235.5 (173.6)   0.23 (2.036)   231 (509)      82         97       115       104          85
        1PH7167-.NG...           195.8 (144.3)   0.23 (2.036)   231 (509)      89        106       124       115         120




                                                                                                                                                                 7




                                                                                        1PH7 motor (SH 100 to SH 160)




        1)   For continuous duty (with 30 % nmax, 60 % 2/3 nmax, 10 % standstill) for a duty cycle time of 10 min. For maintenance intervals for motors and
             components, see the 1PH Motors Configuration Manual.
        2)   Bearing version for coupling/belt output.
        3)   Bearing version for increased maximum speed.
        4)   Version for increased maximum speed only possible with vibration magnitude grade SR. The following option is not possible: Shaft sealing ring.
        5)   The following motor versions are required for ZF gearbox mounting prepared (see Gearboxes for gear selection):
             • Types of construction IM B5 or IM B35
             • Shaft with fitted key and full-key balancing.
        6)   Only appropriate if the sealing ring is occasionally lubricated with oil spray/mist. A sealing ring is not possible with increased maximum speed.
        7)   Motors of shaft height 160 and higher require foot support.
        8)   With default setting of the pulse frequency.

                                                                                                                   Siemens NC
                                                                                                                         Siemens
                                                                                                                              60 · NC
                                                                                                                                   2009
                                                                                                                                      60 ·
                                                                                                                                        (07.09)
                                                                                                                                           2009         7/13
                                                                      © Siemens AG 2009

               Asynchronous motors
      Main spindle motors for SIMODRIVE 611
      1PH7 standard type motors
      SH 180

    ■ Selection and ordering data
       Shaft Rated Continuous                         Speed,        Rated power                                             1PH7 asynchronous motor
       height speed speed, max.                       max.1)        for duty type                                           with solid shaft
                                                                    in accordance with IEC 60034-1                          Forced ventilation
                                                                                                                            Standard type

                                                                   5)
       SH      nrated nS1 cont.2) nS1 cont.3) nS1 cont.4) nmax nmax Prated

                                                                    S1            S6-60 %       S6-40 %        S2-30 min
               rpm    rpm       rpm         rpm       rpm   rpm     kW            kW            kW             kW           Order No.
                                                                    (HP)          (HP)          (HP)           (HP)

       180       500 3 500      3 000       4 500     5 000 7 000 21.5 (28.8)     26.5 (35.5)    30.5 (40.9) 30 (40)        1PH7184 - 7 NT7 7 - 0 7 7 7
               1 000                                              39 (52)         48 (64)        58 (78)      58 (78)       1PH7184 - 7 N D7 7 - 07 7 7
               1 250                                              40 (54)         50 (57)        56 (75)      66 (89)       1PH7184 - 7 N E7 7 - 07 7 7
               1 500                                              51 (68)         68 (91)        81 (109)     81 (68)       1PH7184 - 7 N F7 7 - 07 7 7
               2 500                                              78 (105)        97 (130)      115 (154)    115 (154)      1PH7184 - 7 N L7 7 - 07 7 7

                 500 3 500      3 000       4 500     5 000 7 000 29.6 (39.7)     36.5 (49)      43 (58)        38 (51)     1PH7186 - 7 N T7 7 - 07 7 7
               1 000                                              51 (68)         65 (87)        77 (103)       77 (103)    1PH7186 - 7 N D7 7 - 07 7 7
               1 250                                              60 (80)         71 (95)        80 (107)       84 (113)    1PH7186 - 7 N E7 7 - 07 7 7

       Fans:                                        External fan unit, heavy-gauge threaded cable entry in terminal box                 2
                                                    External fan unit, metric cable entry in terminal box                               7

       Encoder system:                              Incremental encoder sin/cos 1 Vpp, 2 048 S/R without C or D tracks                      N

       Terminal box/                                Top/right                                                                                   0
       Cable entry:                                 Top/DE                                                                                      1
                                                    Top/NDE                                                                                     2
                                                    Top/left                                                                                    3

       Type of construction:                        IM B3                                                                                           0
                                                    IM B3 (IM V5, IM V6) (hoisting system for vertical types of construction)                       1
                                                    IM B359)                                                                                        3

7
                                                    IM B35 (flange D= 450 mm (17.72), only for 1PH7184)9)                                           4
                                                    IM B35 (IM V15, IM V35) (hoisting system for vertical types of construction)9)                  5
                                                    IM B35 (IM V15, IM V35) (flange D = 450 mm (17.72), only for 1PH7184)9)                         6

       Bearing version for:                         Vibration magnitude:          Shaft and flange accuracy:
       Coupling output                              Grade R                       Tolerance N                                                           A
       Coupling output                              Grade R                       Tolerance R                                                           B
       Coupling output                              Grade S                       Tolerance R                                                           C
       Coupling output                              Grade SR                      Tolerance R                                                           D
       Belt output                                  Grade R                       Tolerance N                                                           E
       Belt output                                  Grade R                       Tolerance R                                                           F
       Increased cantilever force (belt output)     Grade R                       Tolerance N                                                           G
       Increased cantilever force (belt output)     Grade R                       Tolerance R                                                           H
       Increased speed (coupling output)            Grade S                       Tolerance R                                                           J

       Shaft extension DE:7)                        Balancing:                    Direction of air flow (fan): Blow-out direction:
       Fitted key                                   Half-key                      DE → NDE                     Right                                        A
       Fitted key                                   Half-key                      NDE → DE                     Axial                                        B
       Fitted key                                   Full-key                      DE → NDE                     Right                                        C
       Fitted key                                   Full-key                      NDE → DE                     Axial                                        D
       Plain shaft                                  –                             DE → NDE                     Right                                        J
       Plain shaft                                  –                             NDE → DE                     Axial                                        K

       Degree of protection:                        Seal:                                                      Paint finish:
       IP55, fan IP54                               –                                                          Primed                                           0
       IP55, fan IP54                               DE flange with shaft sealing ring6)                        Primed                                           2
       IP55, fan IP54                               –                                                          Anthracite                                       3
       IP55, fan IP54                               DE flange with shaft sealing ring6)                        Anthracite                                       5
       IP55, fan IP54                               –                                                          Anthracite, two coats                            6
       IP55, fan IP54                               DE flange with shaft sealing ring6)                        Anthracite, two coats                            8

      To select the type of construction and the degree of protection, see Selection guides.




        7/14         Siemens NC 60 · 2009
                                                                     © Siemens AG 2009

                                                                                                   Asynchronous motors
                                                                                 Main spindle motors for SIMODRIVE 611
                                                                                                                   1PH7 standard type motors
                                                                                                                                      SH 180

■ Selection and ordering data
   Motor type            Rated           Moment of       Weight,        Rated current                               SIMODRIVE 611 power module
   (continued)           torque          inertia         approx.8)      for duty type
                                                                        in accordance with IEC 60034-1              Rated
                                                                                                                    output
                                                                                                                    current10)

                         Mrated          J               m              Irated                                      Irated

                                                                        S1        S6-60 % S6-40 % S2 30 min S1
                         Nm              kgm2            kg             A         A          A         A            A            Order No.
                         (lbf -ft)       (lbf -in-s2)    (lb)

   1PH7184-.NT...        410 (302)       0.5 (4.425)     390 (860)       76        90        103        102          85          For ordering data,
   1PH7184-.N D...       372 (274)       0.5 (4.425)                     90       106        126        126         120          see Converter system
   1PH7184-.N E...       305 (225)       0.5 (4.425)                     85       100        110        128          85
   1PH7184-.N F...       325 (240)       0.5 (4.425)                    120       149        174        174         120
   1PH7184-.N L...       298 (220)       0.5 (4.425)                    172       204        237        237         200

   1PH7186-.N T...       565 (416)       0.67 (5.930)    460 (1 014)    105       126        147        130         120
   1PH7186-.N D...       487 (359)       0.67 (5.930)                   118       141        164        164         120
   1PH7186-.N E...       458 (338)       0.67 (5.930)                   120       135        150        156         120




                                                                                                                                                          7




                                                                                 1PH7 motor (SH 180 and SH 225)




  1)  For continuous duty (with 30 % nmax, 60 % 2/3 nmax, 10 % standstill) for a duty cycle time of 10 min. For maintenance intervals for motors and
      components, see the 1PH Motors Configuration Manual.
  2) Bearing version for coupling/belt output.
  3) Bearing version for increased cantilever force.
  4) Bearing version for increased maximum speed.
  5) Version for increased maximum speed, only possible in combination with vibration magnitude grade S. The following option is not possible:
      Shaft sealing ring.
  6) Only appropriate if the sealing ring is occasionally lubricated with oil spray/mist. A sealing ring is not possible for type of construction IM B3
      (IM V5, IM V6), version with increased cantilever force or increased maximum speed.
  7) The following motor versions are required for ZF gearbox mounting prepared (see Gearboxes for gear selection):
      • Type of construction IM B35, IM V15 (not IM V35)
      • Shaft with fitted key and full-key balancing
      • Bearing version for coupling output
      • Shaft and flange accuracy R
      • DE flange with shaft sealing ring
  8) Applies to type of construction IM B35, as type of construction IM B3, the motor is 20 kg (44 lb) lighter.
  9) Motors of sha