SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

CALOMAT 6 — CALOMAT 6 thermal conductivity gas analyzer – documentation and spare parts

Вид документаКаталожна сторінка
ВиробникSIEMENS
МоделіCALOMAT 6
Група обладнанняother
Мова документаанглійська
Розмір файлу0.1 МБ

Про документ

This page is the documentation and spare parts ordering data for the Siemens CALOMAT 6, an extractive continuous gas analyzer based on thermal conductivity. It lists available manuals in multiple languages and the recommended spare parts with order numbers and recommended quantities for 2-year and 5-year service intervals.

Ключові дані

Line transformer 115 V order no.W75040-B21-D80
Line transformer 230 V order no.W75040-B31-D80
LC display (non-Ex version) order no.W75025-B5001-B1
Measuring cell spare part order no.A5E00095332

Застосування

  • Continuous extractive gas analysis using thermal conductivity measurement

Особливості

  • Manuals available in German, English, French, Italian and Spanish
  • Spare parts recommendation covering analyzer (measuring cell) and electronics components
  • Option: specially cleaned gas path for high oxygen context ("Cleaned for O2 service") — must be specified at ordering

Варіанти замовлення

Manuals
Manual Order No.
CALOMAT 6, Wärmeleitfähigkeitsgasanalysator (German) A5E00116454
CALOMAT 6, Thermal Conductivity Gas Analyzer (English) A5E00116455
CALOMAT 6, Analyseur de gaz à conductivité thermique (French) A5E00116456
CALOMAT 6, Analizzatore di gas a conductivita termica (Italian) A5E00116457
CALOMAT 6, Analizador de gases por conductividad térmica (Spanish) A5E00116458
Interface PROFIBUS DP/PA, ULTRAMAT 6, OXYMAT 6, OXYMAT 61, CALOMAT 6, ULTRAMAT 23 (German and English) A5E00054148
Proposition of spare parts (7MA2521 / 7MB2511 / 7MB2511 Ex)
Description Order No. Qty (2 years) Qty (5 years)
Measuring cell (analyzer part; fits all three versions) A5E00095332 1 1
O-ring, set of 10 (fits all three versions) A5E00124182 1 2
Fusible plug (device fuse), electronics A5E00061505 1 2
Front plate without LCD display C79165-A3042-B508 1 1
Motherboard, with firmware (all three versions) C79451-A3474-B601 1
Adapter board, LCD/keyboard (7MB2511 only) C79451-A3474-B605 1 1
LC display (non-Ex version) W75025-B5001-B1 1 1
Line transformer, 115 V (all three versions) W75040-B21-D80 1
Line transformer, 230 V (all three versions) W75040-B31-D80 1
Connector filter (all three versions) W75041-E5602-K2 1
Fusible plug, T 0.63/250 V (7MB2511, 7MB2511 Ex) W79054-L1010-T630 2 4
Fusible plug, 1 A, 110/120 V (all three versions) W79054-L1011-T100 2 4

Export regulations note: items marked D) subject to AL export regulations: 9I999, ECCN: N; item marked E) subject to AL export regulations: 9I999, ECCN: EAR99H.

Текст документа

               Continuous Gas Analyzers, extractive
      CALOMAT 6
      Documentation

    ■ Selection and Ordering Data
      Manual                                              Order No.        Manual                                                Order No.
      CALOMAT 6                                      D)   A5E00116454      CALOMAT 6                                     D)      A5E00116458
      Wärmeleitfähigkeitsgasanalysator (German)                            Analizador de gases por conductividad térmica
                                                                           (Spanish)

2
      CALOMAT 6                                      D)   A5E00116455
      Thermal Conductivity Gas Analyzer (English)                          ULTRAMAT 6, OXYMAT 6, OXYMAT 61,                D)    A5E00054148
                                                                           CALOMAT 6, ULTRAMAT 23
      CALOMAT 6                                      D)   A5E00116456      Schnittstelle/Interface PROFIBUS DP/PA
      Analyseur de gaz à conductivité thermique                            (German and English)
      (French)
                                                                           D) Subject to AL export regulations: 9I999, ECCN: N
      CALOMAT 6                                      D)   A5E00116457
      Analizzatore di gas a conductivita termica
      (Italian)




      Proposition of spare parts


    ■ Selection and Ordering Data
       Description                                            7MA2521   7MB2511   7MB2511 Ex     2 years    5 years        Order No.
                                                                                                  (qty)      (qty)
       Analyzer part
       Measuring cell                                            x         x           x            1          1      D)   A5E00095332
       O-ring (set of 10)                                        x         x           x            1          2      D)   A5E00124182
       Electronics
       Fusible plug (device fuse)                                                      x            1          2      D)   A5E00061505
       Front plate without LCD display                           x                                  1          1      D)   C79165-A3042-B508
       Motherboard, with firmware                                x         x           x           —           1      D)   C79451-A3474-B601
       Adapter board, LCD/keyboard                               x         x                        1          1      D)   C79451-A3474-B605
       LC display (non-Ex version)                               x                                  1          1      D)   W75025-B5001-B1
       Line transformer, 115 V                                   x         x           x           —           1      D)   W75040-B21-D80
       Line transformer, 230 V                                   x         x           x           —           1      D)   W75040-B31-D80
       Connector filter                                          x         x           x           —           1      E)   W75041-E5602-K2
       Fusible plug, T 0.63/250 V                                x         x                        2          4      D)   W79054-L1010-T630
       Fusible plug, 1 A, 110/120 V                              x         x           x            2          4      D)   W79054-L1011-T100
      D) Subject to AL export regulations: 9I999, ECCN: N
      E) Subject to AL export regulations: 9I999, ECCN: EAR99H
      If the CALOMAT 6 is supplied with a specially cleaned gas path for high oxygen context ("Cleaned for O2 service"), please ensure
      that you specify this when ordering. This is the only way to guarantee that the gas path will continue to comply with the special
      requirements for this version.




       2/152         Siemens PA 01 · 2008


Документ виробника, опублікований як довідковий матеріал на обладнання, яке ми постачаємо. Правовласник може попросити прибрати його — приберемо.