Introduction 1
Fundamental safety
instructions 2
Preconditions 3
SINUMERIK
Installation 4
SINUMERIK Edge
Analyze MyMachine /Condition
Configuration 5
Appendix A
Installation Manual
Valid for control system:
SINUMERIK 840D sl/ 840DE sl
Software
Analyze MyMachine /Condition, Version 2.2
09/2022
A5E45212196B AF
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage
to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices
referring only to property damage have no safety alert symbol. These notices shown below are graded according to
the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be
used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property
damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended or
approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance
are required to ensure that the products operate safely and without any problems. The permissible ambient
conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may
be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described.
Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this
publication is reviewed regularly and any necessary corrections are included in subsequent editions.
Siemens AG A5E45212196B AF Copyright © Siemens AG 2018 - 2022.
Digital Industries Ⓟ 09/2022 Subject to change All rights reserved
Postfach 48 48
90026 NÜRNBERG
GERMANY
Table of contents
1 Introduction ........................................................................................................................................... 5
1.1 About SINUMERIK ................................................................................................................ 5
1.2 About this documentation ................................................................................................... 6
1.3 Documentation on the internet ............................................................................................ 7
1.3.1 Documentation overview SINUMERIK ONE ........................................................................... 7
1.3.2 Documentation overview SINUMERIK 840D sl....................................................................... 8
1.4 Feedback on the technical documentation ........................................................................... 9
1.5 mySupport documentation ................................................................................................ 10
1.6 Service and Support........................................................................................................... 11
1.7 OpenSSL ............................................................................................................................ 13
1.8 General Data Protection Regulation .................................................................................... 14
2 Fundamental safety instructions......................................................................................................... 15
2.1 General safety instructions................................................................................................. 15
2.2 Warranty and liability for application examples ................................................................... 16
2.3 Security information .......................................................................................................... 17
3 Preconditions ....................................................................................................................................... 19
3.1 System requirements ......................................................................................................... 19
3.2 Constraints ........................................................................................................................ 22
4 Installation........................................................................................................................................... 25
4.1 Installing components........................................................................................................ 25
5 Configuration....................................................................................................................................... 27
5.1 Configuring the SINUMERIK Edge Application ..................................................................... 27
5.2 Configuring the SINUMERIK Adapter Service ....................................................................... 30
5.3 Configuring file sharing between SINUMERIK Edge and the SINUMERIK control.................... 31
5.4 Configuring the SINUMERIK Edge MQTT client .................................................................... 34
5.5 Configuring Analyze MyMachine /Condition for MQTT support and data transfer to
MindSphere ....................................................................................................................... 36
5.6 Channel-specific variable SGUD .......................................................................................... 39
5.7 Configuring the SINUMERIK control system for the execution of external measurement
programs ........................................................................................................................... 40
5.8 Integrating Analyze MyMachine /Condition in a SINUMERIK control system ......................... 41
5.9 Defining users and roles (SINUMERIK Edge application)....................................................... 44
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 3
Table of contents
5.10 Defining users and roles (MindSphere application).............................................................. 45
5.11 Configuring Auto Servo Tuning using SINUMERIK Operate................................................... 46
A Appendix.............................................................................................................................................. 47
A.1 List of abbreviations........................................................................................................... 47
Index .................................................................................................................................................... 49
Analyze MyMachine /Condition
4 Installation Manual, 09/2022, A5E45212196B AF
Introduction 1
1.1 About SINUMERIK
From simple, standardized CNC machines to premium modular machine designs – the
SINUMERIK CNCs offer the right solution for all machine concepts. Whether for individual parts
or mass production, simple or complex workpieces – SINUMERIK is the highly dynamic
automation solution, integrated for all areas of production. From prototype construction and
tool design to mold making, all the way to large-scale series production.
Visit our website for more information SINUMERIK (https://www.siemens.com/sinumerik).
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 5
Introduction
1.2 About this documentation
1.2 About this documentation
Overview
This document describes how you commission Analyze MyMachine /Condition.
Target group
This document addresses commissioning engineers and machine tool manufacturers. The
document provides the detailed information required to commission the Analyze MyMachine /
Condition software.
Standard scope
The software installation manual instructs the target group on how to install and uninstall the
software correctly.
Standard scope
This documentation only describes the functionality of the standard version. This may differ
from the scope of the functionality of the system that is actually supplied. Please refer to the
ordering documentation only for the functionality of the supplied drive system.
It may be possible to execute other functions in the system which are not described in this
documentation. This does not, however, represent an obligation to supply such functions with
a new control or when servicing.
For reasons of clarity, this documentation cannot include all of the detailed information on all
product types. Further, this documentation cannot take into consideration every conceivable
type of installation, operation and service/maintenance.
The machine manufacturer must document any additions or modifications they make to the
product themselves.
Websites of third-party companies
This document may contain hyperlinks to third-party websites. Siemens is not responsible for
and shall not be liable for these websites and their content. Siemens has no control over the
information which appears on these websites and is not responsible for the content and
information provided there. The user bears the risk for their use.
Analyze MyMachine /Condition
6 Installation Manual, 09/2022, A5E45212196B AF
Introduction
1.3 Documentation on the internet
1.3 Documentation on the internet
1.3.1 Documentation overview SINUMERIK ONE
Comprehensive documentation about the functions provided in SINUMERIK ONE Version 6.13
and higher is provided in the Documentation overview SINUMERIK ONE (https://
support.industry.siemens.com/cs/ww/en/view/109768483).
You can display documents or download them in PDF and HTML5 format.
The documentation is divided into the following categories:
• User: Operating
• User: Programming
• Manufacturer/Service: Functions
• Manufacturer/Service: Hardware
• Manufacturer/Service: Configuration/Setup
• Manufacturer/Service: Safety Integrated
• Information and training
• Manufacturer/Service: SINAMICS
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 7
Introduction
1.3 Documentation on the internet
1.3.2 Documentation overview SINUMERIK 840D sl
You will find extensive documentation on the functions of SINUMERIK 840D sl from version 4.8
SP4 at 840D sl documentation overview (https://support.industry.siemens.com/cs/ww/en/view/
109766213).
You can display documents or download them in PDF and HTML5 format.
The documentation is divided into the following categories:
• User: Operating
• User: Programming
• Manufacturer/Service: Functions
• Manufacturer/Service: Hardware
• Manufacturer/Service: Configuration/Setup
• Manufacturer/Service: Safety Integrated
• Manufacturer/Service: SINUMERIK Integrate/MindApp
• Information and training
• Manufacturer/Service: SINAMICS
Analyze MyMachine /Condition
8 Installation Manual, 09/2022, A5E45212196B AF
Introduction
1.4 Feedback on the technical documentation
1.4 Feedback on the technical documentation
If you have any questions, suggestions or corrections regarding the technical documentation
which is published in the Siemens Industry Online Support, use the link "Send feedback" link
which appears at the end of the entry.
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 9
Introduction
1.5 mySupport documentation
1.5 mySupport documentation
With the "mySupport documentation" web-based system you can compile your own individual
documentation based on Siemens content, and adapt it for your own machine documentation.
To start the application, click on the "My Documentation" tile on the mySupport homepage
(https://support.industry.siemens.com/cs/ww/en/my):
The configured manual can be exported in RTF, PDF or XML format.
Note
Siemens content that supports the mySupport documentation application can be identified by
the presence of the "Configure" link.
Analyze MyMachine /Condition
10 Installation Manual, 09/2022, A5E45212196B AF
Introduction
1.6 Service and Support
1.6 Service and Support
Product support
You can find more information about products on the internet:
Product support (https://support.industry.siemens.com/cs/ww/en/)
The following is provided at this address:
• Up-to-date product information (product announcements)
• FAQs (frequently asked questions)
• Manuals
• Downloads
• Newsletters with the latest information about your products
• Global forum for information and best practice sharing between users and specialists
• Local contact persons via our Contacts at Siemens database (→ "Contact")
• Information about field services, repairs, spare parts, and much more (→ "Field Service")
Technical support
Country-specific telephone numbers for technical support are provided on the internet at
address (https://support.industry.siemens.com/cs/ww/en/sc/4868) in the "Contact" area.
If you have any technical questions, please use the online form in the "Support Request" area.
Training
You can find information on SITRAIN at the following address (https://www.siemens.com/
sitrain).
SITRAIN offers training courses for automation and drives products, systems and solutions from
Siemens.
Siemens support on the go
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 11
Introduction
1.6 Service and Support
With the award-winning "Siemens Industry Online Support" app, you can access more than
300,000 documents for Siemens Industry products – any time and from anywhere. The app can
support you in areas including:
• Resolving problems when implementing a project
• Troubleshooting when faults develop
• Expanding a system or planning a new system
Furthermore, you have access to the Technical Forum and other articles from our experts:
• FAQs
• Application examples
• Manuals
• Certificates
• Product announcements and much more
The "Siemens Industry Online Support" app is available for Apple iOS and Android.
Data matrix code on the nameplate
The data matrix code on the nameplate contains the specific device data. This code can be read
with a smartphone and technical information about the device displayed via the "Industry
Online Support" mobile app.
Analyze MyMachine /Condition
12 Installation Manual, 09/2022, A5E45212196B AF
Introduction
1.7 OpenSSL
1.7 OpenSSL
This product can contain the following software:
• Software developed by the OpenSSL project for use in the OpenSSL toolkit
• Cryptographic software created by Eric Young.
• Software developed by Eric Young
You can find more information on the internet:
• OpenSSL (https://www.openssl.org)
• Cryptsoft (https://www.cryptsoft.com)
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 13
Introduction
1.8 General Data Protection Regulation
1.8 General Data Protection Regulation
Siemens observes standard data protection principles, in particular the data minimization rules
(privacy by design).
For this product, this means:
The product does not process or store any personal data, only technical function data (e.g. time
stamps). If the user links this data with other data (e.g. shift plans) or if he/she stores person-
related data on the same data medium (e.g. hard disk), thus personalizing this data, he/she must
ensure compliance with the applicable data protection stipulations.
Analyze MyMachine /Condition
14 Installation Manual, 09/2022, A5E45212196B AF
Fundamental safety instructions 2
2.1 General safety instructions
WARNING
Danger to life if the safety instructions and residual risks are not observed
If the safety instructions and residual risks in the associated hardware documentation are not
observed, accidents involving severe injuries or death can occur.
• Observe the safety instructions given in the hardware documentation.
• Consider the residual risks for the risk evaluation.
WARNING
Malfunctions of the machine as a result of incorrect or changed parameter settings
As a result of incorrect or changed parameterization, machines can malfunction, which in turn
can lead to injuries or death.
• Protect the parameterization against unauthorized access.
• Handle possible malfunctions by taking suitable measures, e.g. emergency stop or
emergency off.
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 15
Fundamental safety instructions
2.2 Warranty and liability for application examples
2.2 Warranty and liability for application examples
Application examples are not binding and do not claim to be complete regarding configuration,
equipment or any eventuality which may arise. Application examples do not represent specific
customer solutions, but are only intended to provide support for typical tasks.
As the user you yourself are responsible for ensuring that the products described are operated
correctly. Application examples do not relieve you of your responsibility for safe handling when
using, installing, operating and maintaining the equipment.
Analyze MyMachine /Condition
16 Installation Manual, 09/2022, A5E45212196B AF
Fundamental safety instructions
2.3 Security information
2.3 Security information
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is necessary
to implement – and continuously maintain – a holistic, state-of-the-art industrial security
concept. Siemens’ products and solutions constitute one element of such a concept.
Customers are responsible for preventing unauthorized access to their plants, systems,
machines and networks. Such systems, machines and components should only be connected to
an enterprise network or the internet if and to the extent such a connection is necessary and only
when appropriate security measures (e.g. firewalls and/or network segmentation) are in place.
For additional information on industrial security measures that may be implemented, please
visit
https://www.siemens.com/industrialsecurity (https://www.siemens.com/industrialsecurity).
Siemens’ products and solutions undergo continuous development to make them more secure.
Siemens strongly recommends that product updates are applied as soon as they are available
and that the latest product versions are used. Use of product versions that are no longer
supported, and failure to apply the latest updates may increase customer’s exposure to cyber
threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed
under
https://www.siemens.com/cert (https://www.siemens.com/cert).
Further information is provided on the Internet:
Industrial Security Configuration Manual (https://support.industry.siemens.com/cs/ww/en/
view/108862708)
WARNING
Unsafe operating states resulting from software manipulation
Software manipulations, e.g. viruses, Trojans, or worms, can cause unsafe operating states in
your system that may lead to death, serious injury, and property damage.
• Keep the software up to date.
• Incorporate the automation and drive components into a holistic, state-of-the-art industrial
security concept for the installation or machine.
• Make sure that you include all installed products into the holistic industrial security concept.
• Protect files stored on exchangeable storage media from malicious software by with suitable
protection measures, e.g. virus scanners.
• On completion of commissioning, check all security-related settings.
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 17
Fundamental safety instructions
2.3 Security information
Analyze MyMachine /Condition
18 Installation Manual, 09/2022, A5E45212196B AF
Preconditions 3
3.1 System requirements
Analyze MyMachine /Condition is a hybrid SINUMERIK Edge application consisting of a
SINUMERIK Edge application and a MindSphere application. The MindSphere application can
only be used in conjunction with the SINUMERIK Edge application.
SINUMERIK Edge must be commissioned in order to be able to use Analyze MyMachine /
Condition.
Further information about commissioning is provided in:
• Industrial Edge User Documentation
• MindSphere (https://siemens.mindsphere.io/en)
No additional steps are required for the MindSphere application of Analyze MyMachine /
Condition. The application is directly visible in the tenant after publication.
Observe the following system preconditions.
Note
Memory requirements
In the MindSphere application, Analyze MyMachine /Condition generates files for data
transmission. These files are not automatically deleted in MindSphere.
To free up memory space, manually delete the files that are no longer required.
Note
Analyze MyMachine /Condition sends the content of the file to the SIEMENS operator tenant for
the MindSphere application.
Hardware
The following hardware components must be installed:
• SINUMERIK control
The following control systems are supported:
– SINUMERIK 840D sl NCU 7x0.3 [B]
– SINUMERIK ONE 1750, 1760
• SINUMERIK Edge:
– SIMATIC IPC227E Nanobox or IPC427D with TPM (Trusted Platform Module) support and
with Internet access
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 19
Preconditions
3.1 System requirements
• Optional PCU from 50.5 or IPC from SIMATIC IPC427E with SINUMERIK Operate if
functionality "Integrating Analyze MyMachine /Condition in a SINUMERIK control system
(Page 41)" is used.
• Operating PC
The following screen resolutions are supported:
– 1366x768
– 1600x900
– 1920x1080
SINUMERIK Edge and MindSphere
• A MindSphere account exists.
• SINUMERIK Edge has been commissioned.
Components Version
SINUMERIK Edge from V3.3.1
"From" refers to the specified and all subsequent versions in the line.
• SINUMERIK Edge was onboarded with a MindSphere tenant.
• All of the components for establishing communication between the SINUMERIK control and
SINUMERIK Edge are installed and active.
– Adapter Framework
– SINUMERIK Adapter
– Samba Server
– SINUMERIK Edge MQTT client
– The MindSphere Analyze MyMachine /Condition application is visible in the tenant.
Analyze MyMachine /Condition
20 Installation Manual, 09/2022, A5E45212196B AF
Preconditions
3.1 System requirements
SINUMERIK control
The following SINUMERIK Operate versions are supported:
Components Version
SINUMERIK 840D sl from 4.5 SP4
from 4.7 SP2 HF1
from 4.8 SP2
from 4.92
from 4.93
from 4.94
from 4.95
from 6.13
from 6.14
from 6.15
from 6.20
"From" refers to the specified and all subsequent versions in the line.
Software option
To measure quadrant errors, you require option
"Polynomial interpolation" (6FC5800-0AM18-0YB0)
Software option
To determine the frequency response using measuring function "Auto Servo
Tuning" (AST) on the SINUMERIK control, you require option
"AST CALL BY PART PROG" (6FC5800-0AS10-0YB0)
Activate option "AST CALL BY PART PROG" and configure function "Auto Servo Tuning" using
SINUMERIK-Operate.
Additional information is provided in Chapter: Configuring Auto Servo Tuning using SINUMERIK
Operate (Page 46)
Installing Google Chrome
Google Chrome must be installed on the PCU/IPC if the "Integrating Analyze MyMachine /
Condition in a SINUMERIK control system (Page 41)" functionality is to be used.
• Load the Google Chrome offline installer and transfer it to a USB flash drive.
• Open the installation file in the SINUMERIK control, and follow the installation instructions.
Additional information on processing files in the SINUMERIK control is provided in the
Commissioning Manual Base Software and Operating Software.
Operating PC
An Internet browser has been installed. The use of Google Chrome from V102.x or higher is
recommended.
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 21
Preconditions
3.2 Constraints
3.2 Constraints
Invalid measurement results
Description
If measurements are performed on a SINUMERIK control using SINUMERIK Operate Version
4.5.x, invalid measurement results for measurement groups will sporadically occur.
Remedy
No remedy possible.
Loss of input data
Description
If you click on "Back" while setting up a measurement in the browser, the data already entered
is lost.
Remedy
No remedy possible.
Changing the machine model
Description
The machine model was changed in SINUMERIK with reference to axis settings or other axis-
relevant machine configurations on the SINUMERIK.
Remedy
Restart Analyze MyMachine /Condition.
Several NC programs on the SINUMERIK control
Description
2 NC programs were simultaneously generated on the SINUMERIK Edge network drive. The same
measurement is available twice on the SINUMERIK control.
Remedy
Do not allow the NC program to run with a content of 0 byte.
No additional remedy is possible.
Buttons not visible
Description
In rare cases, the buttons in the "Basic Configuration" tab of the "Configure Measurement"
window are not visible because they are covered by the footer.
Analyze MyMachine /Condition
22 Installation Manual, 09/2022, A5E45212196B AF
Preconditions
3.2 Constraints
Remedy
Press the <CTRL> + <F5> keys. The window is reloaded.
Notice: All changes have to be entered again.
Automatic update of the "Traffic light view"
Description
After installing or restarting the system, the automatic update of the "Traffic light view" does not
function.
Remedy
Delete the data from your browser cache.
The user interface does not respond
Description
The user interface of Analyze MyMachine /Condition does not respond as the application has
crashed.
Remedy
1. Open the MindSphere application Manage MySINUMERIK Edge App Management.
2. Restart Analyze MyMachine /Condition.
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 23
Preconditions
3.2 Constraints
Analyze MyMachine /Condition
24 Installation Manual, 09/2022, A5E45212196B AF
Installation 4
4.1 Installing components
Procedure
Install the following applications for Analyze MyMachine /Condition from MindSphere to
SINUMERIK Edge:
Application name: analyzemymachinecondition
Version: 2.2.0
Note
License fees
If you reinstall the Edge application of Analyze MyMachine /Condition on a re-onboarded asset
for which you have already paid for a single license, please contact your local Siemens sales
office to ensure that the fees are not charged twice.
More information about SINUMERIK Edge is provided in:
• Industrial Edge User Documentation
• MindSphere (https://siemens.mindsphere.io/en)
Software update
If you perform a software update for the Edge application of Analyze MyMachine /Condition
from Version 1.1. to Version 2.0 or higher, the following configuration steps are necessary:
• Update the SGUD variable.
Channel-specific variable SGUD (Page 39)
• Update the application configuration.
Configuring the SINUMERIK Edge Application (Page 27)
• Update the SINUMERIK Adapter HF data configuration from MindSphere Manage
MySinumerik Edge /App Management Application to the Analyze MyMachine /Condition
application-specific configuration.
• After the software has been updated there are two directories on Samba-Share:
– analyzemymachine
– analyzemymachinecondition
Directory "analyzemymachine" is no longer used from Version 2.0.
• Clear your browser cache to update the software user interfaces.
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 25
Installation
4.1 Installing components
Analyze MyMachine /Condition
26 Installation Manual, 09/2022, A5E45212196B AF
Configuration 5
5.1 Configuring the SINUMERIK Edge Application
If you load the Analyze MyMachine /Condition application to the asset using MindSphere, the
SINUMERIK Edge application must be configured before you can use the application.
Procedure
1. Log into MindSphere and select "App Management".
2. Click on the desired asset.
A list opens with the installed services of this asset.
3. Click on the small arrow to view the details for "analyzemymachinecondition".
4. Under "Operations", click on the "Edit App Instance Configuration" button.
"Config Edit" opens.
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 27
Configuration
5.1 Configuring the SINUMERIK Edge Application
5. The standard configuration for "axisid=1" can be found under "datasourceConfig →
requiredDatasource → 0 → services → subscription-service/v1 → subscriptions → 0 →
datapoints".
Enter the following values for each axis used by Analyze MyMachine /Condition:
– DES_POS|[axisId]
– ENC1_POS|[axisId]
– ENC2_POS|[axisId]
– TORQUE|[axisId]
Example: DES_POS|1
Enter the following parameters for "messageName":
– ammc_trigger_param_changed
Configure this parameter for every channel.
– feedrate_changed
This parameter does not have to be configured for every channel or every axis.
Analyze MyMachine /Condition
28 Installation Manual, 09/2022, A5E45212196B AF
Configuration
5.1 Configuring the SINUMERIK Edge Application
6. For frequency response tests, enter the name of the network drive under "specificConfig".
As the default "Field : Value" pair of values, "SambaDrive":"//DEV_5" is stored. Replace value
"//DEV_5" with the value of field "Symbolic" of the network drive, which is connected with the
Samba Share of SINUMERIK Edge.
– For SINUMERIK Version 4.5, use value "Path" of the network drive without the Edge name/
IP address. For example, path = "//192.168.214.249/Share" > //Share".
– For SINUMERIK Version 4.7 and higher, use network drive "Share name". For example,
Share name = "Share" > "//Share
You will find more information on configuration of the network drive in SINUMERIK Operate
in Chapter Configuring file sharing between SINUMERIK Edge and the SINUMERIK control
(Page 31).
7. Press the "Save" button to save the changes.
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 29
Configuration
5.2 Configuring the SINUMERIK Adapter Service
5.2 Configuring the SINUMERIK Adapter Service
If you load the Analyze MyMachine /Condition application to the asset using MindSphere, the
SINUMERIK Adapter Service must be configured before you use the application.
Procedure
1. Log into MindSphere and select "App Management".
2. Click on the desired asset.
A list opens with the installed services of this asset.
3. Click on the small arrow to view the details for "sinumerikadapter".
4. Under "Operations", click on the "Edit App Instance Configuration" button.
"Config Edit" opens.
5. Enter the NCU serial number under "specificConfig → serialNumber".
6. Press the "Save" button to save the changes.
Locating the NCU serial number
1. In SINUMERIK Operate, press key <MENU SELECT> or <F10>.
2. Select the "Setup" operating area.
3. Press softkey "Mach. data".
4. Press softkey "General MD".
5. Check MD18030[0] $MN_HW_SERIAL_NUMBER in the list of parameters.
Analyze MyMachine /Condition
30 Installation Manual, 09/2022, A5E45212196B AF
Configuration
5.3 Configuring file sharing between SINUMERIK Edge and the SINUMERIK control
5.3 Configuring file sharing between SINUMERIK Edge and the
SINUMERIK control
Analyze MyMachine/Condition uses NC program code to perform measurements. As soon as a
measurement is saved, Analyze MyMachine/Condition generates an NC program and saves it to
the file system of SINUMERIK Edge. To perform this measurement, the NC program must be
transferred to the file system of the SINUMERIK control.
To do this, configure file sharing between SINUMERIK Edge and the SINUMERIK control as
follows:
1. Install and configure the "sambaserver" file sharing application on the SINUMERIK Edge.
2. Configure a network drive for the SINUMERIK control and connect the drive to the SINUMERIK
Edge file sharing system.
Configuring a file sharing application on the SINUMERIK Edge
1. Log into MindSphere and select "App Management".
2. Click on the desired asset.
A list opens with the installed services of this asset.
3. If the "sambaserver" application is not installed, install this application.
You will find further information on installing Edge applications in the Industrial Edge user
manual.
4. Click the small arrow to view the details for "sambaserver".
5. Under "Operations", click on the "Edit App Instance Configuration" button.
"Config Edit" opens.
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 31
Configuration
5.3 Configuring file sharing between SINUMERIK Edge and the SINUMERIK control
6. The user name and password are stored under the entry "specificConfig →
sambaCredentials".
Use this logon data to configure the logical drive in SINUMERIK Operate.
7. Click the "Save" button to save your changes.
Configuring the network drive in SINUMERIK Operate
The following parameters are used for the network drive:
Entry Description
Type NW Windows
User name and password The logon data for the file system of SINUMERIK Edge are defined in the
"sambaserver" application.
SINUMERIK 4.5
Path The path comprises the IP address of SINUMERIK Edge and the share name
of the directory.
The following entry is used as default:
//192.168.214.249/share
The IP address can deviate from this depending on the settings in the Mind‐
Sphere Asset Manager.
SINUMERIK 4.7 and higher
Computer name The default setting of the IP address of the SINUMERIK Edge is as follows:
192.168.214.249
The IP address can deviate from this depending on the settings in the Mind‐
Sphere Asset Manager.
Share name share
Softkey
Access level Select the axis level so that the machine operator can access the drive.
The following entry is used as default:
"Key switch 0"
Softkey text Softkey labeling, e.g. "AMM/C"
Procedure
1. Start SINUMERIK Operate.
2. Press the "Setup" softkey.
Analyze MyMachine /Condition
32 Installation Manual, 09/2022, A5E45212196B AF
Configuration
5.3 Configuring file sharing between SINUMERIK Edge and the SINUMERIK control
3. Press the "HMI" and "Log. drive" softkeys.
The "Set Up Drives" window opens.
4. Select a free softkey.
5. Complete the entries.
SINUMERIK 4.5 SINUMERIK 4.7 and higher
Further information
Additional information on configuring the softkeys and the logical drives is provided in the
Universal Operating Manual.
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 33
Configuration
5.4 Configuring the SINUMERIK Edge MQTT client
5.4 Configuring the SINUMERIK Edge MQTT client
Precondition
To be able to send MQTT messages, the SINUMERIK Edge MQTT client must be configured before
you use the Analyze MyMachine /Condition application.
Procedure
1. Log into MindSphere and select "App Management".
2. Click on the desired asset.
A list opens with the installed services of this asset.
3. Click the small arrow to view the details for "sinumerikedgemqttclient"
4. Under "Operations", click on the "Edit App Instance Configuration" button.
"Config Edit" opens.
Analyze MyMachine /Condition
34 Installation Manual, 09/2022, A5E45212196B AF
Configuration
5.4 Configuring the SINUMERIK Edge MQTT client
5. Under "specificConfig → brokers", enter the following data:
Parameter Meaning
host: 172.31.4.1 IP address or host name of the MQTT broker that receives the
MQTT messages.
port: 0 Port of the MQTT broker.
label: ammcMqttLabel Label to identify the MQTT broker.
Several brokers can be configured using the same label. Published
data are then sent to each individual broker.
logLevel: debug Log level of the application:
• trace
• debug
• info
• warning
• error
• Critical
"info" is set as default.
statisticsInterval: 99999 Interval, in which statistical messages can be recorded.
6. Press the "Save" button to save the changes.
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 35
Configuration
5.5 Configuring Analyze MyMachine /Condition for MQTT support and data transfer to MindSphere
5.5 Configuring Analyze MyMachine /Condition for MQTT support and
data transfer to MindSphere
As soon as the measurement was performed, all of the configuration-relevant data are sent
using a MQTT message.
Procedure
1. Log into MindSphere and select "App Management".
2. Click on the desired asset.
A list opens with the installed services of this asset.
3. Click the small arrow to view the details for "sinumerikedgemqttclient"
4. Under "Operations", click on the "Edit App Instance Configuration" button.
"Config Edit" opens.
Analyze MyMachine /Condition
36 Installation Manual, 09/2022, A5E45212196B AF
Configuration
5.5 Configuring Analyze MyMachine /Condition for MQTT support and data transfer to MindSphere
5. Enter the following data under "specificConfig":
Parameter Meaning
sendDataToMDSP: true Using the Analyze MyMachine /Condition application, data is sent
from the SINUMERIK Edge application to MindSphere.
"true" is set as default.
Diagnostic information is provided in the SINUMERIK Edge appli‐
cation if invalid parameters are transferred.
mqttPublishEnabled: false MQTT messages can be sent if "true" is set.
"false" is set as default.
mqttTopicPrefix: prefix A prefix can be specified using this value.
No value is defined as default.
Restrictions:
• The value may contain a maximum of 4 topic levels and 32
alphanumeric characters.
• It is not permissible that the value starts with "/".
• If a value is not specified, then the topic starts with "ammc".
• This entry is case-sensitive.
Example: "companyX/factoryY/floor1/roomA"
machineName: machineName A machine name can be specified using this value to uniquely
identify which message is sent to which SINUMERIK machine or
Edge Box.
"machineName" is set as default.
Restrictions:
• The value may only contain one topic level, a minimum of 1
and a maximum of 32 alphanumeric characters.
• This entry is case-sensitive.
• If the default value is deleted and a value is not entered, then
an error is logged, and MQTT messages cannot be sent.
Analyze MyMachine /Condition
Installation Manual, 09/2022, A5E45212196B AF 37
Configuration
5.5 Configuring Analyze Показано початок документа. Повний текст — у PDF за посиланням вище.
Документ виробника, опублікований як довідковий матеріал на обладнання, яке ми постачаємо. Правовласник може попросити прибрати його — приберемо.