System 450™ Series Expansion Modules with
Relay Outputs
Part No. 24-7664-2683, Rev. D
Installation Instructions Issued April 16, 2009
C450SBN-1 Supersedes February 10, 2009
C450SCN-1
Application 13 11
(1/2) (7/16) 40
(1-9/16)
IMPORTANT: Use this System 450 Series
Expansion Module with Relay Output only as an
4
operating control. Where failure or malfunction of the (3/16)
System 450 expansion module could lead to 75 Screw
127 DIN Rail (2-15/16)
personal injury or property damage to the controlled Clips Slots
(5)
(Four)
equipment or other property, additional precautions
must be designed into the control system.
Incorporate and maintain other devices, such as
supervisory or alarm systems or safety or limit
controls, intended to warn of or protect against 61 61
failure or malfunction of the System 450 expansion (2-3/8) (2-3/8)
module. 1/2 in. Nominal
FIG:sys450_dims
Trade Size
System 450 is a family of electronic control, expansion, Conduit Hole
22
and power modules that are easily assembled and set (7/8)
up to provide reliable digital temperature, pressure ,and
humidity control for a wide variety of Heating, Figure 1: System 450 Module Dimensions
Ventilation, Air Conditioning, and Refrigeration (HVACR),
and commercial/industrial process applications.
• Allow sufficient space for wires and connections.
C450SxN-1 models are Single-Pole, Double-Throw
• Do not mount the modules on surfaces that are
(SPDT) relay expansion modules: C450SBN-1 models
prone to vibration or in locations where radio
provide one SPDT relay, C450SCN-1 models provide
frequency or electromagnetic emissions may
two SPDT relays.
cause interference.
Refer to the System 450 Series Technical Bulletin
• Do not install the modules in airtight enclosures.
(LIT-12011459) for detailed information on designing,
installing, setting up, and troubleshooting System 450 • Do not install heat-generating devices in an
Series control applications. enclosure with the modules that may cause the
temperature to exceed the ambient operating
Installation conditions.
Location Considerations
Mounting
Observe the following System 450 location guidelines:
Mount System 450 modules on 35 mm DIN rail
• Ensure that the mounting surface can support the (recommended) or directly to an even wall surface. To
module assembly, mounting hardware, and any mount the modules on DIN rail:
(user-supplied) panel or enclosure.
1. Provide a section of 35 mm DIN rail that is longer
• Mount the modules horizontal, in an upright than the module assembly width, and mount the
orientation wherever possible. DIN rail mount is DIN rail horizontally in a suitable location using
recommended. appropriate mounting hardware/fasteners.
• Mount modules on flat even surfaces. 2. Clip the control module on the rail, position the
• Mount the modules in locations free of corrosive upper DIN rail clips on the top rail, and gently snap
vapors and observe the operating conditions in the the lower clips on to the rail.
Technical Specifications.
System 450™ Series Expansion Modules with Relay Outputs Installation Instructions 1
3. Clip the remaining modules to the right of the
IMPORTANT: Do not exceed the System 450
control module on to the DIN rail and plug together.
module electrical ratings. Exceeding module
To direct mount modules to wall surfaces: electrical ratings can result in permanent damage to
1. Plug the modules together, remove the module the modules and void any warranty.
covers, place the assembly against wall surface
horizontally in a suitable location, and mark the IMPORTANT: Do not connect 24 VAC supply
mount hole locations on the surface. power to the System 450 modules before finishing
wiring and checking all wiring connections. Short
2. Install appropriate screw fasteners, leaving screw circuits or improperly connected wires can result in
heads approximately one to two turns away from damage to the modules and void any warranty.
flush to the surface.
See Figure 2 and Table 1 for electrical termination
3. Place the assembly over screw heads and on the
locations, wiring information, and electrical ratings.
mounting slots, and carefully tighten mount screws.
Note: If you mount the modules on an uneven
6-Pin 6-Pin
surface, do not damage the housings when Module Module
tightening mounting screws. Use shims/washers to Connector Connector
mount module assembly evenly on the surface.
Some models have a
Refer to the control sensor installation instructions for second output relay and
information on locating and mounting control sensors. terminal block labeled
LNC2, LNO2, and LC2.
Wiring
WARNING: Risk of Electric Shock.
FIG:sys450_rly_expnsn_wir
Disconnect each of multiple power
! supplies before making electrical Internal SPDT Relay
(Normally Closed Position)
connections. More than one disconnect
may be required to completely
de-energize equipment. Contact with
components carrying hazardous voltage Dry Contact
Relay Output Terminals
LNC1 LNO1
can cause electric shock and may result
LC1 (See Technical Specifications
in severe personal injury or death. for Relay Electrical Ratings)
IMPORTANT: Use copper conductors only. Make Figure 2: C450SxN-1 Wiring Terminals
all wiring in accordance with local, national, and
regional regulations. Note: The System 450 Output Relay terminals
connect to an internal SPDT relay and do not supply
any power to the control application. See Figure 2.
Table 1: System 450 Terminal Wiring Information
Label Terminal Function Wire Sizes
LNC1, Connects equipment control circuit to the Normally Close contact on the SPDT output 28 AWG to 14 AWG
LNC2 relay. 0.3 mm2 to 1.5 mm2
LNO1, Connects equipment control circuit to the Normally Open contact on the SPDT output
LNO2 relay.
LC1, LC2 Connects line (power) to Common (C) on the SPDT relay.
2 System 450™ Series Expansion Modules with Relay Outputs Installation Instructions
Technical Specifications
C450SxN-1
Product C450SBN-1: System 450 Expansion Module with one SPDT output relay
C450SCN-1: System 450 Expansion Module with two SPDT output relays
Supply Power C450-YNN-1 Power Supply Module or
24 (20-30) VAC Safety Extra-Low Voltage (SELV) (Europe) Class 2 (North America)
50/60 Hz, 10 VA minimum
Ambient Operating Conditions Temperature: -40 to 66°C (-40 to 150°F)
Humidity: Up to 95% RH non-condensing; Maximum Dew Point 29°C (85°F)
Ambient Shipping and Storage Temperature: -40 to 80°C (-40 to 176°F)
Conditions Humidity: Up to 95% RH non-condensing; Maximum Dew Point 29°C (85°F)
Output Relay Contacts General: 1/2 HP at 120/240 VAC, SPDT
Specific: AC Motor Ratings 120 VAC 208/240 VAC
AC Full-load amperes: 9.8 A 4.9 A
AC Locked-rotor amperes: 58.8 A 29.4 A
_____________________________________
10 amperes AC Non-inductive at 24/240 VAC
Pilot Duty: 125 VA at 24/240 VAC
Control Construction Independently-mounted control, surface mounted with Lexan® 950 enclosure suitable
for DIN rail mounting or direct mounting to a hard, even surface.
Dimensions (H x W x D) 127 x 61 x 61 mm (5 x 2-3/8 x 2-3/8 in.)
Weight C450SBN-1: 172 gm (0.38 lb)
C450SCN-1: 186 gm (0.41 lb)
Compliance North America: cULus Listed; UL 60730, File E27734, Vol. 1; FCC Compliant to
CFR47, Part 15, Subpart B, Class B
Industry Canada (IC) Compliant to Canadian ICES-003, Class B limits
Europe: Mark: CE Compliant; Low Voltage Directive (2006/95/EC); EMC Directive
(2004/108/EC); RoHS Directive (2002/95/EC); WEEE Directive (2002/96/EC)
Australia: Mark: C-Tick Compliant (N1813)
The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these
specifications, consult Johnson Controls Application Engineering at (414) 524-5535. Johnson Controls, Inc. shall not be liable for damages
resulting from misapplication or misuse of its products.
United States Emissions Compliance
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Canadian Emissions Compliance
This Class (B) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la Classe (B) respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Building Efficiency
507 E. Michigan Street, Milwaukee, WI 53202
Metasys® and Johnson Controls® are registered trademarks of Johnson Controls, Inc.
All other marks herein are the marks of their respective owners. © 2009 Johnson Controls, Inc.
System 450™ Series Expansion Modules with Relay Outputs Installation Instructions 3