Code No. LIT-1921450
Issued January 15, 2008
R-4000
Miniature Pressure Regulator
Description • includes a barbed fitting for 1/4 in. O. D.
polytubing for panel mounting and a 4 in.
The R-4000 Miniature Pressure Regulator
(102 mm) length of polytubing for conduit
provides a method to readjust the setpoint of
box mounting. Supplied with a two sided
pneumatic controllers in low volume
dial plate for direct or reverse acting
applications. The output pressure varies in
applications
proportion to the rotation of the adjusting knob.
• can be mounted several different ways
Refer to R-4000 Miniature Pressure Regulator including:
Product Bulletin (LIT-7171360) for important - panel mounted if the panel thickness
product information. does not exceed 3/8 in. (10 mm)
- surface mounted using mounting bracket
Features C-5222-100
• use with 0.005 and 0.007 in. R-3710 - conduit box mounted using a gang box
restrictors with a minimum depth of 2-3/4 in. R-4000 Miniature Pressure Regulator
• includes various output spans that can be (70 mm). Use a surface extension box
placed anywhere within pressure ranges when the proper conduit box is not
and obtained by proper tab removal from available, or when the wall is deeper
than 2-3/4 in. Repair Information
the stop plate
If the R-4000 Miniature Pressure Regulator
fails to operate within its specifications, replace
Selection Chart
the unit. For a replacement regulator, contact
Code Number Output Pressure psig (kPa) Break Off Tab Sets Numbered the nearest Johnson Controls®
R-4000-4 1 (7) None representative.
2 (14) 1
3 (21) 1 and 2
5 (35) 1, 2 and 3
6 (42) 1, 2, 3 and 4
R-4000-3 12 (84) 1, 2 and 3
C-5222-100 Mounting Bracket for Surface Mounting
The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2011 Johnson Controls, Inc. www.johnsoncontrols.comПозиції каталогу з цим документом