Electric non-spring return valve actuator, VA9104 Series

Вид документаТехнічний паспорт
ВиробникJCI
МоделіVA9104-AGA-2S, VA9104-AGA-3S, VA9104-GGA-2S, VA9104-GGA-3S, VA9104-IGA-2S, VA9104-IGA-3S
Група обладнанняvalves
Мова документаанглійська
Розмір файлу0.1 МБ

Про документ

Direct-mount, non-spring return electric valve actuators operating on AC 24 V power, driven by a synchronous motor. They provide accurate positioning on Johnson Controls VG1000 Series DN15, DN20, and DN25 (1/2, 3/4, and 1 in.) ball valves in HVAC applications. The -2S variants use a plenum-rated cable; the -3S variants use M3 screw terminals.

Ключові дані

Running torque35 lb⋅in (4 N⋅m)
Travel time60 seconds at 60 Hz (72 seconds at 50 Hz) for 90° of rotation
Power requirementAC 24 V +25%/-20% at 50/60 Hz, 2.1 VA Supply, Class 2 or SELV
Rotation range93° ±3°, CW or CCW
Cycles100,000 full stroke cycles; 2,500,000 repositions at rated running torque
Audible noise rating35 dBA nominal at 39-13/32 in. (1 m)
Ambient operating temperature-4 to 140°F (-20 to 60°C); 90% RH maximum, noncondensing
Shipping weight1.25 lb (0.55 kg)

Застосування

  • Positioning of VG1000 Series DN15, DN20, DN25 (1/2, 3/4, 1 in.) ball valves
  • Heating, Ventilating, and Air Conditioning (HVAC) applications
  • Open ceiling environments (whisper quiet operation)
  • Ceiling plenum applications (with plenum cable on -2S models)
  • Low pressure steam applications with M9000-561 thermal barrier installed

Особливості

  • 35 dBA nominal audible noise rating — meets audible noise requirements for open ceiling environments
  • Synchronous drive — constant rotation time independent of load
  • 100,000 cycle rating — years of trouble-free service
  • Direct mounting with single screw — reduces installation time and cost
  • Manual override — allows manual positioning of the valve independent of the power supply
  • Plenum cable or screw terminal electrical connections — quick wiring, suitable for ceiling plenum applications
  • 3/8 in. flexible metal conduit connector on VA9104-xGA-2S models
  • Weather shield available for field mounting — follows NEMA 4X IP66 specifications
  • Optional M9000-561 thermal barrier — extends fluid temperature range to 284°F (140°C) or 15 psig saturated steam
  • 5-year warranty

Технічні дані

Parameter Value
Power requirements AC 24 V +25%/-20% at 50/60 Hz, 2.1 VA Supply, Class 2 or Safety Extra-Low Voltage (SELV)
Control type VA9104-AGA-xS: Floating Control without Timeout; VA9104-GGA-xS: Proportional Control; VA9104-IGA-xS: Floating or On/Off Control with Timeout
Control signal VA9104-AGA-xS: AC 24 V +25%/-20% at 50/60 Hz, Class 2 or SELV Without Timeout; VA9104-GGA-xS: DC 0 (2) to 10 V or 0 (4) to 20 mA With Field Furnished 500 ohm Resistor; VA9104-IGA-xS: AC 24 V +25%/-20% at 50/60 Hz, Class 2 or SELV With Timeout
Control input impedance VA9104-GGA-xS Voltage Input: 200,000 ohms; Current Input: 500 ohms With Field Furnished 500 ohm Resistor
Running torque 35 lb⋅in (4 N⋅m)
Travel time 60 Seconds at 60 Hz (72 Seconds at 50 Hz) for 90° of Rotation
Rotation range 93° ±3°, CW or CCW
Cycles 100,000 Full Stroke Cycles; 2,500,000 Repositions at Rated Running Torque
Audible noise rating 35 dBA Nominal at 39-13/32 in. (1 m)
Electrical connections VA9104-xGA-2S: 48 in. (1.2 m) UL 444 Type CMP Plenum Rated cable with 19 AWG (0.75 mm²) conductors and 0.25 in. (6 mm) ferrule ends and connector for 3/8 in. (9.5 mm) flexible metal conduit; VA9104-xGA-3S: M3 Screw Terminals (Requires a Slotted Screwdriver)
Enclosure VA9104-xGA-2S: NEMA 2, IP42; VA9104-xGA-3S: NEMA 1, IP40
Ambient conditions, operating -4 to 140°F (-20 to 60°C); 90% RH Maximum, Noncondensing
Ambient conditions, storage -20 to 150°F (-29 to 66°C); 90% RH Maximum, Noncondensing
Fluid temperature limits (VG12x1 and VG18x1 Series) 23 to 203°F (-5 to 95°C)
Fluid temperature limits (VG12x5 and VG18x5 Series) -22 to 212°F (-30 to 100°C)
Fluid temperature limits (VG12x5 and VG18x5 Series with M9000-561 Thermal Barrier Installed) -22 to 284°F (-30 to 140°C) water; 15 psig (103 kPa) at 250°F (121°C) Saturated Steam
Shipping weight 1.25 lb (0.55 kg)

Варіанти замовлення

Selection chart:

Code Number Rotation Time For 90° Power Requirement Power Consumption Signal Feedback Electrical Connection
VA9104-AGA-2S 60 s at 60 Hz / 72 s at 50 Hz AC 24 V 2.1 VA On/Off and Floating Point Without Timeout Plenum cable
VA9104-AGA-3S 60 s at 60 Hz / 72 s at 50 Hz AC 24 V 2.1 VA On/Off and Floating Point Without Timeout M3 screw terminals
VA9104-GGA-2S 60 s at 60 Hz / 72 s at 50 Hz AC 24 V 2.1 VA Proportional (0 (2) to 10 VDC; 0 (4) to 20 mA with 500 ohm resistor) Plenum cable
VA9104-GGA-3S 60 s at 60 Hz / 72 s at 50 Hz AC 24 V 2.1 VA Proportional (0 (2) to 10 VDC; 0 (4) to 20 mA with 500 ohm resistor) M3 screw terminals
VA9104-IGA-2S 60 s at 60 Hz / 72 s at 50 Hz AC 24 V 2.1 VA On/Off and Floating Point With Timeout Plenum cable
VA9104-IGA-3S 60 s at 60 Hz / 72 s at 50 Hz AC 24 V 2.1 VA On/Off and Floating Point With Timeout M3 screw terminals

Accessories (order separately):

Code Number Description
M9000-200 Commissioning Tool that Provides a Control Signal to Drive 24 V On/Off, Floating, Proportional, and/or Resistive Electric Actuators
M9000-341 Weather Shield Kit for VG1000 Series Ball application of VA9104, M(VA) 9203, and M(VA)9208 Series Electric Non-Spring Return Actuators (quantity 1)
M9000-551 Mounting Hardware Replacement Kit (quantity 1)
M9000-561 Thermal Barrier Kit for M9000-551 and M9000-560 Ball Valve Linkages. Extends the VA9104, M(VA) 9203, and M(VA)9208 Series Electric Non-Spring Return Actuators applications to include low pressure steam (quantity 1)

Допуски та стандарти

  • United States: UL Listed, CCN XAPX, File E27734; UL 60730-1A: 2003-08, Ed. 3.1; UL 60730-2-14: 2002-02, Ed. 1
  • Canada: UL Listed, CCN XAPX7, File E27734; UL 60730-1:02-CAN/CSA: July 2002, 3rd Ed.; CSA C22.2 No. 24-93
  • Europe: CE Mark — EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC
  • Australia and New Zealand: C-Tick Mark, Australia/NZ Emissions Compliant

Текст документа

                                                                                                                                                                                                                                                                                                                    Code No. LIT-1900354
                                                                                                                                                                                                                                                                                                                    Issued July 6, 2011

VA9104-xGA-2S, VA9104-xGA-3S Series
Electric Non-Spring Return Valve Actuators

Description                                                                                             Features
The VA9104 Series Actuators are                                                                         •   35 dBA nominal audible noise rating —
direct-mount, non-spring return electric valve                                                              meets the audible noise requirements for
actuators that operate on AC 24 V power. Use                                                                open ceiling environments: whisper quiet
these synchronous motor-driven actuators to                                                                 operation will not disturb building
provide accurate positioning on                                                                             occupants
Johnson Controls® VG1000 Series DN15,                                                                   •   synchronous drive — provides a constant
DN20, and DN25 (1/2, 3/4, and 1 in.) ball                                                                   rotation time that is independent of the load
valves in Heating, Ventilating, and Air                                                                 •   100,000 cycle rating — provides years of
Conditioning (HVAC) applications.                                                                           trouble-free service
The VA9104 Series Electric Non-Spring                                                                   •   direct mounting with single screw —
Return Actuators provide a running torque of                                                                reduces installation time and cost
35 lb⋅in (4 N⋅m). The nominal travel time is                                                            •   manual override — allows for manual
60 seconds at 60 Hz (72 seconds at 50 Hz) for                                                               positioning of the valve, independent of a                                                                                                                                                              VA9104 Series
90° of rotation.                                                                                            power supply                                                                                                                                                                               Electric Non-Spring Return Actuator on a
Refer to the VA9104-xGA-2S and                                                                          •   plenum cable or screw terminal electrical                                                                                                                                                           VG1000 Series Ball Valve
VA9104-xGA-3S Series Electric Non-Spring                                                                    connections — make wiring quick and easy
Return Valve Actuators Product Bulletin                                                                     while allowing for ceiling plenum
(LIT-12011050) for important product                                                                        applications                                                                                                                                                                       Repair Information
application information.                                                                                •   3/8 in. flexible metal conduit connector on                                                                                                                                        If the VA9104 Series Electric Non-Spring
                                                                                                            VA9104-xGA-2S models — simplifies                                                                                                                                                  Return Valve Actuator fails to operate within its
                                                                                                            installation and field wiring                                                                                                                                                      specifications, replace the unit. For a
                                                                                                        •   available weather shield for field mounting                                                                                                                                        replacement electric actuator, contact the
                                                                                                            — follows NEMA 4X IP66 specifications                                                                                                                                              nearest Johnson Controls® representative.
                                                                                                        •   optional M9000-561 thermal barrier —
                                                                                                            extends the fluid temperature range to
                                                                                                            284°F (140°C) or 15 psig saturated steam
                                                                                                        •   5-year warranty — protects the consumer
                                                                                                            investment

Selection Chart
 Code Number                  Rotation Time                           Power                                           Power                                                        Input Signal                                                                                         Position                                   Electrical Connection
                                 For 90°                            Requirement                                    Consumption                                                                                                                                                         Feedback


                                                                                                                                                                                                                                                                                                                  48 in. (1.2 m) UL 444 Type CMP Plenum




                                                                                                                                                         On/Off and Floating Point Without Timeout   On/Off and Floating Point With Timeout
                                                                                                                                                                                                                                                           0 (2) to 10 VDC




                                     Power On – Running (Seconds)       24 VAC + 25%/-20% at 50/60 Hz                    VA Rating, Transformer Sizing
                                                                                                                                                                                                                                                                                                                   Rated Cable With 19 AWG (0.75 mm2)




                                                                                                                                                                                                                                                                                                                                                               M3 Screw Terminals
                                                                                                                                                                                                                                                                                          0(2) to 10 VDC        Conductors and 0.25 in. (6 mm) Ferrule Ends




                                                                                                                                                                                                                                              0 (4) to 20 mA (with 500 ohm Resistor)
                                                                                                                                                                                                                                                                                                                 and Connector for 3/8 in. (9.5 mm) Flexible



                                                                                                                                                                                                                                                                                                                                Metal Conduit

 VA9104-AGA-2S                 60 s at 60 Hz                                  X                                         2.1                                       X                                                                                                                                                                 X
                               72 s at 50 Hz
 VA9104-AGA-3S                 60 s at 60 Hz                                  X                                         2.1                                       X                                                                                                                                                                                                X
                               72 s at 50 Hz
 VA9104-GGA-2S                 60 s at 60 Hz                                  X                                         2.1                                                                                                                                  X                               X                                      X
                               72 s at 50 Hz
 VA9104-GGA-3S                 60 s at 60 Hz                                  X                                         2.1                                                                                                                                  X                                                                                                     X
                               72 s at 50 Hz
 VA9104-IGA-2S                 60 s at 60 Hz                                  X                                         2.1                                                                                  X                                                                                                                      X
                               72 s at 50 Hz
 VA9104-IGA-3S                 60 s at 60 Hz                                  X                                         2.1                                                                                  X                                                                                                                                                     X
                               72 s at 50 Hz



The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2011 Johnson Controls, Inc.                  www.johnsoncontrols.com

                                                                                                                                           1 of 2
Electric Non-Spring Return Valve Actuators (Continued)


Accessories (Order Separately)
 Code Number                          Description
 M9000-200                            Commissioning Tool that Provides a Control Signal to Drive 24 V On/Off, Floating, Proportional, and/or Resistive Electric Actuators
 M9000-341                            Weather Shield Kit for VG1000 Series Ball application of VA9104, M(VA) 9203, and M(VA)9208 Series Electric Non-Spring Return
                                      Actuators (quantity 1)
 M9000-551                            Mounting Hardware Replacement Kit (quantity 1)
 M9000-561                            Thermal Barrier Kit for M9000-551 and M9000-560 Ball Valve Linkages. Extends the VA9104, M(VA) 9203, and M(VA)9208 Series
                                      Electric Non-Spring Return Actuators applications to include low pressure steam (quantity 1).

Technical Specifications
                                                  VA9104-xGA-2S, -3S Series Electric Non-Spring Return Valve Actuators
 Power Requirements                                                             AC 24 V +25%/-20% at 50/60 Hz, 2.1 VA Supply, Class 2 or Safety Extra-Low Voltage (SELV)
 Control Type                            VA9104-AGA-xS                          Floating Control without Timeout
                                         VA9104-GGA-xS                          Proportional Control
                                         VA9104-IGA-xS                          Floating or On/Off Control with Timeout
 Control Signal                          VA9104-AGA-xS                          AC 24 V +25%/-20% at 50/60 Hz, Class 2 or SELV Without Timeout
                                         VA9104-GGA-xS                          DC 0 (2) to 10 V or 0 (4) to 20 mA With Field Furnished 500 ohm Resistor
                                         VA9104-IGA-xS                          AC 24 V +25%/-20% at 50/60 Hz, Class 2 or SELV With Timeout
 Control Input Impedance                 VA9104-GGA-xS                          Voltage Input: 200,000 ohms
                                                                                Current Input: 500 ohms With Field Furnished 500 ohm Resistor
 Running Torque                                                                 35 lb⋅in (4 N⋅m)

 Travel Time                                                                    60 Seconds at 60 Hz (72 Seconds at 50 Hz) for 90° of Rotation

 Rotation Range                                                                 93° ±3°, CW or CCW
 Cycles                                                                         100,000 Full Stroke Cycles; 2,500,000 Repositions at Rated Running Torque
 Audible Noise Rating                                                           35 dBA Nominal at 39-13/32 in. (1 m)
 Electrical Connections                  VA9104-xGA-2S                          48 in. (1.2 m) UL 444 Type CMP Plenum Rated cable with 19 AWG (0.75 mm2) conductors and
                                                                                0.25 in. (6 mm) ferrule ends and connector for 3/8 in. (9.5 mm) flexible metal conduit.
                                         VA9104-xGA-3S                          M3 Screw Terminals (Requires a Slotted Screwdriver)
 Enclosure                               VA9104-xGA-2S                          NEMA 2, IP42
                                         VA9104-xGA-3S                          NEMA 1, IP40
 Ambient Conditions                      Operating                              -4 to 140°F (-20 to 60°C); 90% RH Maximum, Noncondensing
                                         Storage                                -20 to 150°F (-29 to 66°C); 90% RH Maximum, Noncondensing
 Fluid Temperature Limits      VG12x1 and VG18x1 Series                         23 to 203°F (-5 to 95°C)
 (Actuator and Valve Assembly)
                               VG12x5 and VG18x5 Series                         -22 to 212°F (-30 to 100°C)
                                         VG12x5 and VG18x5 Series               -22 to 284°F (-30 to 140°C) water; 15 psig (103 kPa) at 250°F (121°C) Saturated Steam
                                         With M9000-561 Thermal
                                         Barrier Installed
 Compliance                              United States                          UL Listed, CCN XAPX, File E27734; to UL 60730-1A: 2003-08, Ed. 3.1, Automatic Electrical
                                                                                Controls for Household and Similar Use; and UL 60730-2-14: 2002-02, Ed. 1, Part 2 Particular
                                                                                Requirements for Electric Actuators
                                         Canada                                 UL Listed, CCN XAPX7, File E27734; to UL 60730-1:02-CAN/CSA: July 2002, 3rd Ed.,
                                                                                Automatic Electrical Controls for Household and Similar Use; and CSA C22.2 No. 24-93
                                                                                Temperature Indicating and Regulating Equipment
                                         Europe                                 CE Mark – Johnson Controls, Inc., declares that this product is in compliance with the essential
                                                                                requirements and other relevant provisions of the EMC Directive 2004/108/EC and
                                                                                Low Voltage Directive 2006/95/EC.
                                         Australia and New Zealand              C-Tick Mark, Australia/NZ Emissions Compliant
 Shipping Weight                                                                1.25 lb (0.55 kg)




The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2011 Johnson Controls, Inc.                  www.johnsoncontrols.com

                                                                                       2 of 2
