Product Bulletin     Medium User Interface (MUI)
                                                                             Issue Date       October 21, 2009

                                  Medium User Interface (MUI)
                                          Version 3

The MUI is a remote user interface device for the FX          The format of the MUI is fully configurable using the
Platform that supports FX06, FX07, FX14, FX15, FX16,          FX Builder software package.
and FXVMA controllers. You can use the MUI as a
                                                              The MUI is a cost-effective solution for monitoring,
portable hand held unit, or permanently mount it in a
                                                              commissioning, and servicing your building control
panel or on the wall.
                                                              system installation.
The MUI provides an easy way for the building operator
or maintenance engineer to monitor and adjust the
operation of the FX field controller. You can configure
the MUI to receive event and alarm messages, to
change time schedules, and to display event and trend
log data. Access to data and operating commands are
controlled by passwords.
With the FXVMA, the MUI functions as an airflow
balancing tool to support the commissioning of Variable
Air Volume (VAV) units.
The MUI presents data in a text format on a
4-line x 26-character backlit Liquid Crystal Display          Figure 1: Medium User Interface (MUI) Version 3
(LCD) and on an array of Light-Emitting Diodes (LEDs)
for quick recognition of equipment operating status.

                                              Features and Benefits
       ‰ Menu Driven Operation             Provides an easy and intuitive operation – you select from a list of
                                           options to monitor and control the system.

       ‰ Password Access Control           Provides protection against unauthorized use.

       ‰ Event Summary                     Provides a quick overview of currently active or non-acknowledged
                                           event and alarm conditions.

       ‰ Event History                     Provides a list of the latest events and alarms with time and date of
                                           occurrence.

       ‰ Trend Log                         Allows the viewing of trend data from selected points for monitoring
                                           and diagnostic purposes.

       ‰ Time Scheduling                   Allows you to view and adjust the time schedules in the connected
                                           FX controller for the switching of the supervised equipment.

       ‰ VAV Box Air Balancing             Provides access to automatic test routines and data in the FXVMA
                                           controller to quickly verify correct operation, or identify mechanical
                                           system problems.

       ‰ Fully Programmable                Enables customization of the MUI for each project using a design
                                           template in the FX Builder software configuration tool.

       ‰ Local Panel Mounting              Provides power from the controller with the connection cable –
                                           available for order with the MUI unit.

       ‰ Remote Mounting                   Provides universal 12-24 VAC or 9-48 VDC power supply and isolated
                                           communications interface for mounting in panel or surface mounting up
                                           to 300 m (1,000 ft) from the controller.

© 2009 Johnson Controls, Inc.                                                                                          1
  Code No. LIT-12011578                                                                           www.johnsoncontrols.com
Product Overview
                                                           Account Password Protection
MUI Features                                               The MUI has a user account system that is protected by
The MUI has an array of 10 LEDs, a state-of-the-art        passwords that are defined in FX Builder. Three security
backlit LCD display screen, and 6 operating keys. The      levels of account protection prevent access by
LCD display screen shows 4 lines of up to 26               unauthorized users. The MUI prompts you to log in for
alpha-numeric characters.                                  any password-protected operation.
                                                                          LOG-IN REQUIRED
                                                                  User: Supervisor
                                                                  Code: ****
                                                                      Figure 4: Account Log-In Prompt

     Figure 2: MUI LEDs, Screen, and Control Keys          Time Schedulers
You can configure the LEDs to indicate summary data        You can view the time schedule programs in the
from the monitored and controlled equipment. The LEDs      FX controller on the MUI. Users with the proper level of
provide a quick overview of the status without using the   account access can log in with their password and
operating keys.                                            change the execution times and exception dates.
Detailed information is organized into data pages that             OFFICES ZONE 1 - WEEKDAY
you select from a menu page. The display of data                  ►08:00 Occupied
pages, and the position of the cursor on the screen, are           12:30 Standby
                                                                   13:30 Unoccupied
controlled by the four direction keys (  ,   ,    , and
   ), and actions are confirmed or cancelled by the                 Figure 5: Occupancy Scheduler Page
and     keys.
                                                                  ←      OCT – 2009                 →
                                                                  TH 14 – Normal
                SETPOINTS                                         FR 15 - Holiday
       ►Entrance Hall     19.0°C                                  SA 16 – Alternate                ↓
        Conference Room   20.5°C
        Offices Floor 1   21.0°C ↓                                         Figure 6: Calendar Page

                 Figure 3: Data Points                     Trend Data
                                                           The MUI enables you to view trend data that the
FX Controller Support                                      FX controller collects, and add and delete data points
The MUI connects to the FX06, FX07, FX14, FX15,            from the trend log table. You select Trends in the main
FX16, and FXVMA field controllers. An FX controller        menu and then select the variable you want to view. The
with an integral display supports one MUI, either the      data appears in the order and time range that you
local panel mount version or the remote mount version.     select, and you scroll through the data using the
An FX controller without an integral MUI supports one or   direction keys.
two MUIs. One of the MUIs can be the local panel
                                                                        SELECT VARIABLE
version and can be powered by the controller. When                ►Zone_1_Temp
connected to an FXVMA controller, the MUI functions as             Zone_2_Temp
an air balancing tool for commissioning the Variable Air           Zone 2 Humidity                   ↓
Volume (VAV) box.
                                                                    Figure 7: Selecting the Trend Variable
Communication with FX Controllers
The MUI connects to the Remote Display port of the                  10/12/2009 17:34                 ↑
FX controller. The MUI is a slave network device of the               → 20.7 °C
                                                                    10/12/2009 17:24
FX controller, and receives and sends information over                → 20.9 °C                      ↓
the serial communication bus. This constant
communication keeps the MUI and controller databases                    Figure 8: Viewing Trend Data
fully synchronized for monitoring of (and access to) all
system functions and information available from the
controlled equipment.

2 Medium User Interface (MUI) Version 3 Product Bulletin
Event Notification and Management                               Programming
When the FX controller detects an event or alarm                You program the MUI along with the control application
condition, the LCD screen of the MUI displays the name          for the FX controller using the FX Builder software
of the event and the status (the buzzer may be activated        package. You select and enter data point names and
for events that require acknowledgment).                        status values in the application configuration program
                                                                for the MUI. You also define the status values
The event then appears in the EVENT SUMMARY as
                                                                associated with the LEDs, and any special functions for
long as it is active, or has not been acknowledged by an
                                                                the control keys. Event acknowledgement key(s) must
authorized user (if an acknowledgement is required).
                                                                be defined in FX Builder.
The event summary page provides an overview of all
                                                                As the MUI application is built in FX Builder, you view
points that are currently active or in alarm, in order of
                                                                the display format in a configuration panel on the
priority.
                                                                computer screen.
               EVENT SUMMARY
        Ø   Zone_1_Temp    Low
        O ♪ Supply_Fan     Fail
          ♪ Supply_Filter Dirty ↓
               Figure 9: Event Summary
From the EVENT SUMMARY you can view the details of
an active event, including the date and time of
occurrence, the acknowledgement status, and account
name.
        12/10/2009        16:06:00
         Supply_Fan
         Ø ♪Fail
         Event Priority: 3       ↓
        12/10/2009        16:15:34                                        Figure 13: MUI Configuration Panel
         Event Acknowledged
         Supervisor                                             This enables you to fully configure the MUI at design
                                                                time before the MUI and FX controller are available for
                Figure 10: Event Details                        downloading and testing.
The EVENT HISTORY file stores recent events. Details
of past events can appear with the date and time of             FXVMA Support
occurrence and, by scrolling left, you can view the user        When connected to the FXVMA controller, the MUI
name and time of acknowledgement.                               provides information and command capabilities needed
        12/10/2009     17:34:12             ↑                   for monitoring and commissioning the FXVMA controller,
              Supply_Filter                                     and air balancing the VAV box.
                Ø Clean
        ◄                                   ↓                   The point data, command capabilities, and navigation
                                                                structures are defined in the FXVMA application
             Figure 11: Event History Details                   software using FX Builder.

Communications Parameters                                                      Flow Calibration
                                                                         Flow Override        Auto
You can view and modify the communication
                                                                         Flow Hood Value      800#
parameters and message destinations from the MUI,
when the FX controller is configured as a stand-alone                    Supply Flow            0# ↓
device (to send out event messages over its serial port).                Calculate Gain         No
Access is protected by the account password feature.                     Calculate Gain Status ---
                                                                         Calc Pickup Gain     0.0#
                        MENU                                             Supply Area         0.50#
         Modem
         SMS                                                             Damper Position        0%
         E-Mail                             ↓                            Altitude               0#
         WEB                                                             Gain Settle Time      10S

   Figure 12: Access to Communication Parameters                      Figure 14: FXVMA Flow Calibration Details
                                                                The MUI can also be connected to the FX controller via
                                                                the Network Room Module (NRM) that senses room
                                                                temperature and setpoint adjustment.

                                                Medium User Interface (MUI) Version 3 Product Bulletin    3
Dimensions
Wall mounting requires a minimum of 45 mm (1.8 in.)          Panel mounting requires a minimum of 45 mm (1.8 in.)
free space in front of the mounting surface for clearance    free depth behind the panel for the plug-in connectors at
from nearby objects, such as sliding doors or movable        the rear.
panels, or for clearance within a protective enclosure or
cover.

                                                                                          5 7)
                                                                                  4 0 (1 .

                            72 (2.83)

                                                                              )
                                                                    ( 7. 28
                                                             1 85

                                                            Wall Mounting

                                                                                                7   )
                                                                                       40 ( 1. 5

                                                                                   58 (2.28)

                           72 (2.83)

                                                                                                        FIG: mui_dimensions
                                                                        .64 )
                                                              19 4 (7

                                                            Panel Mounting

                                        Figure 15: MUI Dimensions, mm (in.)

4 Medium User Interface (MUI) Version 3 Product Bulletin
Ordering Codes
Table 1: Ordering Codes
 Item Code                  Description
 LP-DIS60P20-0C             Medium User Interface (MUI) Version 3 (non-isolated version); can be mounted up to
                            3 m (9.8 ft) from the FX controller and includes panel mounting hardware.
 LP-DIS60P21-0C             Medium User Interface (MUI) Version 3 (isolated version); can be mounted up to
                            300 m (1,000 ft) from the FX controller and includes panel and wall mounting hardware.
                            Link cable for the connection of the MUI Version 3 LP-DIS60P20-0C (non-isolated panel
 LP-KIT007-000C             mount version) to the FX07, FX14, FX15, and FX16 controller – 3 m (9.8 ft).
                            Link cable for the connection of the MUI Version 3 LP-DIS60P20-0C (non-isolated panel
 LP-KIT007-005C             mount version) to the FX06 controller – 3 m (9.8 ft).
                            MUI Panel Mount Kit. Contains the mounting hardware (bezel, gaskets, clips, and
 LP-KIT060-000C             connector) for one MUI as spare parts.
                            All parts included with MUI Version 3.

Technical Specifications
Table 2: Technical Specifications
 Product                             Medium User Interface (MUI) Version 3
                                     LP-DIS60P20-0C — Powered from the FX controller
 Power Requirements                  LP-DIS60P21-0C — Universal power supply: 9 to 48 VDC, or 12 to 24 VAC
                                     Safety Extra-Low Voltage — SELV (Europe) or Class 2 supply (North America)
 Power Consumption                   200 mA or 2.5 W maximum at 9 to 48 VDC
                                     3.5 VA maximum at 12 to 24 VAC
 Ambient Operating                   -20 to +60°C (-4 to +140°F)
 Conditions                          10 to 90%; RH (noncondensing)
 Ambient Storage                     -20 to +70°C (-4 to +158°F)
 Conditions                          10 to 90%; RH (noncondensing)
 Display and Keypad                  LCD: 4 lines x 26 characters backlit
                                     Keypad: 6 buttons
                                     LEDs: 2 x 5 array
 Shipping Weight                     0.4 kg (0.9 lb)
 Housing Protection                  IP30 for hand-held and wall mounting applications
                                     IP54 for panel mounting applications
 Housing Material                    Polycarbonate + ABS (GE CYCOLOY),
                                     self-extinguishing UL94V-0
 Dimensions (H x W x D)              72 x 194 x 40 mm (2.83 x 7.64 x 1.57 in.)
                                     Width = 185 mm (7.28 in.) without panel mount bezel
 CE and UL Compliance                 Europe       – 2004/108/EC, EMC Directive: EN 61000-6-3, EN 61000-6-1
                                      Canada       – UL Listed (PAZX7), CAN/CSA C22.2 No. 205, Signal Equipment
                                                   – Industry Canada, ICES-003
                                      United       – UL Listed (PAZX), UL 916, Energy Management Equipment
                                      States       – FCC compliant to CFR 47, Part 15, Subpart B, Class A

The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond
these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from
misapplication or misuse of its products.

                                                        Medium User Interface (MUI) Version 3 Product Bulletin                    5
                                                                                                     Building Efficiency
                                                                            507 E. Michigan Street, Milwaukee, WI 53202

                                                     Johnson Controls® is a registered trademark of Johnson Controls, Inc.
                             All other marks herein are the marks of their respective owners. © 2009 Johnson Controls, Inc.

6 Medium User Interface (MUI) Version 3 Product Bulletin

Позиції каталогу з цим документом

Документ виробника, опублікований як довідковий матеріал на обладнання, яке ми постачаємо. Правовласник може попросити прибрати його — приберемо.