The YORK® YLPA is a third-generation air-to-water scroll heat pump available in High Efficiency (HE) and Standard Efficiency (SE) model ranges, with multiple scroll compressors per unit. It provides both cooling and heating with Eurovent A-Class certified full load efficiency and is specifically designed for HFC-410A refrigerant.
Ключові дані
| Refrigerant | HFC-410A |
|---|
| Sound pressure at 10 m | as low as 54 dB(A) |
|---|
| Cooling capacity range | 342 … 647 kW |
|---|
| Heating capacity range | 351 … 666 kW |
|---|
| Full load efficiency (EER) | up to 3.27 |
|---|
| Part load efficiency (ESEER) | up to 4.6 |
|---|
| Extended operating envelope | down to -10 °C ambient, hot water above 45 °C |
|---|
| Energy efficiency class | Eurovent Class A |
|---|
Застосування
- Air-to-water heating and cooling for commercial buildings
- New builds and retrofit upgrades where floor space is limited
- Systems where a support boiler should be minimised (extended envelope down to -10 °C with hot water above 45 °C)
- Fan-coil / standard air-con systems without buffer tank (minimum water volume requirement)
- BMS-supervised installations via Metasys®, Bacnet, Modbus, N2 or Lonworks
Особливості
- Eurovent A-Class certified full load efficiency in cooling and heating modes; part load efficiency exceeds full load efficiency
- Optimised defrost cycle: optimised liquid distribution through coils, coil module design and fan control to prevent moisture accumulation, auto-adaptive defrost controls
- Very quiet operation: compressors in one acoustically sealed enclosure, aerodynamically efficient fans in separate compartments; options include variable fan speeds and compressor sound attenuation
- Zero ODP refrigerant HFC-410A, compliant with European Commission 2020 renewables targets
- Plug-and-play installation: single point power connection, optional hydronic kit, integrated hydronic components
- Microprocessor controller with 40-character plain-language display (temperatures, pressures, operating hours, number of starts, start/stop holiday times); compressor lead/lag control, system safety protection, integral circulating pumps
- Every unit fully factory tested before shipment
Технічні дані
| Parameter |
Value |
| Refrigerant |
HFC-410A |
| Sound pressure at 10 m (Eurovent conditions) |
54 – 56 dB(A) depending on model |
| Cooling capacity (Eurovent: water 12°C/7°C, ambient 35°C) |
342 – 647 kW |
| Heating capacity (Eurovent: water 40°C/45°C, ambient 7°C) |
351 – 666 kW |
| EER (cooling, full load) |
3.26 / 3.24 / 3.23 / 3.11 / 3.02 (HE models); 3.08 / 3.01 / 3.00 / 2.96 / 2.97 (SE models) |
| ESEER (cooling, part load) |
4.5 / 4.5 / 4.6 / 4.4 / 4.4 (HE models); 4.0 / 4.1 / 4.1 / 3.9 / 3.9 (SE models) |
| Heating COP |
3.27 / 3.22 / 3.20 / 3.24 / 3.23 (HE models); 3.11 / 3.18 / 3.19 / 3.17 / 3.10 (SE models) |
| Length |
4937 mm / 5854 mm / 6971 mm depending on model |
| Width |
2246 mm |
| Height |
2501 mm |
| Operating weight |
4600 – 6695 kg depending on model |
| Extended operating envelope |
Operation down to -10 °C with hot water temperature above 45 °C |
| BMS communication |
Bacnet, Modbus, N2, Lonworks; Metasys® preconfigured |
Model table — High Efficiency Models
| Model |
Cooling capacity [kW] |
EER |
ESEER |
Heating capacity [kW] |
COP |
Sound pressure [dB(A)] |
Length [mm] |
Width [mm] |
Height [mm] |
Weight [kg] |
| 0355HE |
359 |
3.26 |
4.5 |
369 |
3.27 |
55 |
4937 |
2246 |
2501 |
4750 |
| 0425HE |
444 |
3.24 |
4.5 |
460 |
3.22 |
55 |
5854 |
2246 |
2501 |
5400 |
| 0505HE |
526 |
3.23 |
4.6 |
554 |
3.20 |
55 |
6971 |
2246 |
2501 |
6100 |
| 0570HE |
590 |
3.11 |
4.4 |
600 |
3.24 |
56 |
6971 |
2246 |
2501 |
6495 |
| 0640HE |
647 |
3.02 |
4.4 |
666 |
3.23 |
56 |
6971 |
2246 |
2501 |
6695 |
Model table — Standard Efficiency Models
| Model |
Cooling capacity [kW] |
EER |
ESEER |
Heating capacity [kW] |
COP |
Sound pressure [dB(A)] |
Length [mm] |
Width [mm] |
Height [mm] |
Weight [kg] |
| 0340SE |
342 |
3.08 |
4.0 |
351 |
3.11 |
54 |
4937 |
2246 |
2501 |
4600 |
| 0415SE |
424 |
3.01 |
4.1 |
439 |
3.18 |
55 |
4937 |
2246 |
2501 |
5000 |
| 0495SE |
513 |
3.00 |
4.1 |
527 |
3.19 |
56 |
4937 |
2246 |
2501 |
5200 |
| 0560SE |
568 |
2.96 |
3.9 |
581 |
3.17 |
55 |
5854 |
2246 |
2501 |
5695 |
| 0610SE |
636 |
2.97 |
3.9 |
666 |
3.10 |
56 |
6971 |
2246 |
2501 |
6235 |
Варіанти замовлення
- Two ranges: High Efficiency (HE) models 0355HE–0640HE and Standard Efficiency (SE) models 0340SE–0610SE
- Options: variable fan speeds, compressor sound attenuation, optional hydronic kit
Допуски та стандарти
- Eurovent A-Class certification program (full load efficiency, cooling and heating modes)
- European Commission 2020 renewables targets compliant
- Montreal Protocol aligned (HFC-410A, zero ODP)
Текст документа
York YLPA Heat Pump
Air to water.
Naturally.
Sound
Ease of installation
Noise pollution as low as 54 dBA*
Plug and play solution
Efficiency
Sustainability Class A energy efficiency
Zero ODP
*Sound pressure at 10 metres according to Eurovent conditions.
Introducing Introducing YLPA
the new YLPA
Heat Pump.
Everyone is looking for a heat pump that is energy efficient, easy
to install, quiet to run, and supported by a comprehensive and skilled
backup service. Welcome to the reality of the YLPA Heat Pump.
Efficiency
Eurovent A-Class certified full load efficiency, high part load
efficiency, improved defrost cycle, extended operating envelope.
Sound
Designed for incredibly quiet operation.
Sustainability
European Commission 2020 renewables targets compliant,
specifically designed for HFC-410A.
Ease of installation
Quick and easy to install, compact design, Metasys® ready.
Reliability
Our third generation of fully factory tested scroll heat pumps.
And thanks to our extensive service solutions and support,
minimal maintenance is assured.
It is simple, quiet, efficient – and all you need.
Efficiency
Designed,
built and tested
for efficiency.
The YORK® YLPA is our third generation of scroll heat pumps, and
our design engineers now have an extensive knowledge of the
technology, continually honing the design to achieve high
performance while maintaining excellent reliability and increasing
energy efficiency.
Full and part load efficiency
The incorporation of multiple scroll compressors results in high full
load efficiency – up to EER 3.17 – and part load efficiency - up to
ESEER 4.4 – in cooling mode.
Full load efficiency levels exceed the requirements of the Eurovent
A-Class certification program, in both cooling and heating modes.
The operation at part load exceeds full load efficiency, driving
down operating costs and further increasing efficiency.
Designing for defrost
The YLPA development process focussed on minimising the impact
of the defrost cycle on the overall efficiency of the pump through:
• Optimising liquid distribution through the coils in heating mode
• Coil module design and fan control to prevent moisture
accumulation on the coil fins
• Auto-adaptive controls to optimise the frequency and duration
of the defrost cycle itself.
Less need for a boiler
The extended envelope enables operation down to -10°C with
production of hot water temperature above 45°C, thus minimising
the need for operating a support boiler.
Tested all over
Global collaboration has also allowed us to gain invaluable experience
thanks to extensive test programs in our state-of-the-art laboratories
across the globe, as well as in real working situations on a number of
field trial sites before production begins.
Sound
Sound
investment.
Generally with heat pumps you have a choice: efficient, or quiet.
The YORK® YLPA offers the best of both worlds.
The YORK® YLPA has been designed not only to meet sound level
requirements during the day, when background noise levels often
mask unit sound levels, but also at night, when background levels
are lower.
It’s been specifically designed for low sound operation by arranging all
the compressors together in one acoustically sealed enclosure, and
aerodynamically efficient fans in separate compartments prevent air
recirculation and reduce wasteful and noisy stop/start operation.
It runs so quietly, at sound levels as low as 54 dB(A), you can have
an undisturbed conversation standing right next to it.
It’s also flexible, with a variety of options like variable fan speeds
and compressor sound attenuation so you can tailor it to your site’s
requirements.
Sustainability
The
sustainable
solution.
The YORK® YLPA is not only an energy-saving tool, it’s also
renewable energy technology, considerably reducing CO 2 emissions
and complying with European Commission 2020 renewables
targets.
It’s specifically designed for HFC-410A, which has zero ozone-
depletion potential (ODP) and is aligned with the Montreal Protocol.
The European Partnership for Energy and the Environment (EPEE),
the de facto voice of the heating, cooling and refrigeration industry
in Europe, has stated that heat pumps of the calibre of the YORK®
YLPA can help European Member States achieve their renewables
targets, and should be included in their National Renewable Energy
Action Plans, as well as in their National Energy Efficiency Action
Plans.
Ease of installation
Plug
and play.
The York YLPA is straightforward to install, a simple ‘plug and play’
unit with single point power connection and optional hydronic kit.
YLPA requires a minimum water volume to satisfy only one minute
of unit operation at minimum cooling or heating capacity, so on
standard air-con systems, such as Fan-Coil for example, a buffer
tank is not required.
The pump is very compact in design, with all necessary hydronic
components integrated, so there’s no requirement for additional
floor space. This makes it ideal both for saving floor space in new
builds, or squeezing into retrofit upgrades.
Either way, with the support of our fully trained technicians during
the commissioning period, installation is a breeze.
Metasys systems have been preconfigured to automatically
communicate with the York YLPA, so supervision through Metasys
could not be easier. It’s also natively capable of communicating with
BMS systems through Bacnet, Modbus, N2 and Lonworks protocols.
YLPA has a microprocessor controller with a 40 character ‘plain
language’ display of temperatures, pressures, operating hours,
number of starts and start/stop holiday times. Control functions
include accurate liquid temperature, compressor lead/lag, system
safety protection and integral circulating pumps.
Every YLPA pump is fully factory tested before shipment in order
to ensure it’s in perfect working order, and ready for trouble free
installation.
Why YLPA?
Why choose
YLPA?
Our machines are subjected to rigorous pre-production testing and
extensive trials, but it doesn’t stop there. Every machine is additionally
fully tested before being shipped out to make sure that, on arrival,
installation can be carried out on time and everything is up and
running to schedule, hassle free.
Once it’s running, we are there to keep it running. To ensure maximum
usage and minimum worry, our service and parts network offers regular
Planned Service Agreements (PSA) for the York YLPA, making it easy to
keep your system in optimum condition – there’s no one better placed
to maintain your equipment than its original manufacturers.
In the long run, regular maintenance will save you money, and also help
you do your bit to contribute to a sustainable world, ensuring equipment
will be operating as energy efficiently as possible.
For more information, visit www.johnsoncontrols.co.uk
Technical specifications
Technical
specifications.
High Efficiency Models
He Ca pa ci
at ty
Ca
ing EE [kW ]2
So R 3
Co pa un d Pr
ci Le es su
ol ty
ng th re [d B(
in
[m m A)
[k W ] ]5
g
id th
EE W [m m
]1
He ig ]
ES R3 ht [m m
Co He O pe ra ]
olin EE at in
t in g W
R4
ei gh
g g t[kg ]
0355HE 359 3.26 4.5 369 3.27 55 4937 2246 2501 4750
0425HE 444 3.24 4.5 460 3.22 55 5854 2246 2501 5400
0505HE 526 3.23 4.6 554 3.20 55 6971 2246 2501 6100
0570HE 590 3.11 4.4 600 3.24 56 6971 2246 2501 6495
0640HE 647 3.02 4.4 666 3.23 56 6971 2246 2501 6695
Standard Efficiency Models
He Ca pa ci
at ty
Ca
ing EE [kW ]2
So R 3
Co pa un d Pr
ci Le es su
ol ty
ng th re [d B(
in
[m m A)
[k W ] ]5
g
id th
EE W [m m
]1
He ig ]
ES R3 ht [m m
Co He O pe ra ]
olin EE atin
t in g W
R4
ei gh
g g t[kg ]
0340SE 342 3.08 4.0 351 3.11 54 4937 2246 2501 4600
0415SE 424 3.01 4.1 439 3.18 55 4937 2246 2501 5000
0495SE 513 3.00 4.1 527 3.19 56 4937 2246 2501 5200
0560SE 568 2.96 3.9 581 3.17 55 5854 2246 2501 5695
0610SE 636 2.97 3.9 666 3.10 56 6971 2246 2501 6235
1: Cooling Capacity at Eurovent Conditions, entering/leaving chilled water temperature 12°C/7°C, ambient temperature 35°C
2: Heating Capacity at Eurovent Conditions, entering/leaving hot water temperature 40°C/45°C, ambient temperature 7°C
3: Energy Efficiency Ratio
4: European Seasonal Energy Efficiency Ratio
5: Sound Pressure at 10 metres according to Eurovent conditions. LS models
6: Subject to change without prior notice
For smartphone.
Energy solutions / Large tonnage chillers / Small tonnage chillers
Fire & security solutions / Industrial refrigeration solutions
Residential & commercial HVAC solutions / Building Management Systems
HVAC control products / Global WorkPlace Solutions
HVAC service, parts & retrofit solutions
© Johnson Controls, 2010 PUBL-6569
Johnson Controls Inc, Building Efficiency, De Kleetlaan 3, Diegem Zuid - Pegasus Park, Brussels, Belgium B-1831.
Johnson Controls reserve the right, in line with continuing research and development, to amend or change specifications without notice.
Документ виробника, опублікований як довідковий матеріал на обладнання, яке ми постачаємо. Правовласник може попросити прибрати його — приберемо.