SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

Electric valve actuator VA-7200

Файл за старою адресою не зберігся. Нижче — документ виробника на те саме обладнання.

Вид документаКаталожна сторінка
ВиробникJCI
МоделіVA-7200-1001, VA-7202-1001, VA-7200-8201, VA-7202-8201
Група обладнанняvalves
Мова документаанглійська
Розмір файлу0.1 МБ

Про документ

The VA-720x Series synchronous motor driven actuator provides floating or proportional control of valves with up to 19 mm stroke in heating, ventilation and air conditioning applications. This compact, non-spring return actuator has a 1000 N nominal force and responds to a variety of input signals. It can be field mounted or ordered factory coupled to VG7000, VG8000, VG9000 and VGS8000 Series valves.

Ключові дані

Actuator force1000 N +30% / -20%
Stroke20 mm maximum; 8, 10, 13, 19 mm selectable
Supply voltage24 V ±15%, 50…60 Hz
Control signalFloating or proportional (0…10 VDC or 0(4)…20 mA)
Nominal speed at 50 Hz (60 Hz)4 (3.2) s/mm
Enclosure protectionIP 42 (EN 60529)
Ambient operating condition-5 to +55 °C, non condensing
Net weight1.0 kg

Застосування

  • Floating or proportional control of valves in HVAC applications
  • Factory-fitted combinations with VG7000 Series Cast Bronze Valves
  • Combinations with VG8000 Series PN16 and PN25 Flanged Valves
  • Combinations with VG9000 Series PN6 and PN10 Flanged Valves
  • Combinations with VGS8000 Series Male Threaded Valves
  • Sequential operation of several actuators from one 0…10 V controller output (minimum adjustable span 2 V enables up to 5 sequenced devices)

Особливості

  • 1000 N force output compact unit — covers a wide range of applications with one actuator
  • Magnetic clutch provides constant output force for positive close-off of valves and protects motor in stall conditions
  • "Signal fail" safe position: safety position after control signal failure; up/down selectable in-situ
  • Selectable stroke via jumpers: 8 mm, 10 mm, 13 mm, 19 mm
  • Direct/reverse action selectable via jumper
  • Voltage/current input signal selection via jumper

Технічні дані

Parameter Value
Models Floating: VA-7200-xx01; Proportional: VA-72x2-xx01
Type of motor Synchronous / reversible
Supply voltage (50/60 Hz) 24 V ± 15%, 50…60 Hz
Actual power 5 W
Apparent power 5.6 VA at 50 Hz / 6.7 VA at 60 Hz
Electronic positioner ratings 2 VA
Positioner input impedance 100 kΩ (0…10 VDC); 500 Ω (0…20 mA)
Actuator force 1000 N +30% -20%
Stroke 20 mm maximum; 8, 10, 13, 19 mm selectable
Nominal speed at 50 Hz (60 Hz) 4 (3.2) s/mm
Enclosure protection IP 42 (EN 60529)
Enclosure material Self extinguishing VO-UL 94 ABS + PC
Hand wheel material Self extinguishing nylon PA
Yoke material Die cast aluminium
Ambient operating condition -5 to +55 °C, non condensing
Ambient storage condition -20 to +65 °C, non condensing
Electrical connections 2.5 mm² (floating), 1.5 mm² (proportional)
Net weight 1.0 kg

Варіанти замовлення

For VG7000 Series Valves:

  • VA-7200-1001 — Floating control, 24 VAC supply
  • VA-7202-1001 — Proportional control (0…10 VDC / 0(4)…20 mA), 24 VAC supply

For VG8000, VG9000 and VGS8000 Series Valves:

  • VA-7200-8201 — Floating control, 24 VAC supply
  • VA-7202-8201 — Proportional control (0…10 VDC / 0(4)…20 mA), 24 VAC supply

Factory-fitted valve-actuator combination: add "+M" to the end of the actuator ordering code (e.g. VG7203AT + VA-7202-1001+M).

Factory settings: 19 mm stroke, 0…10 V input signal, direct action, fail-safe position "fully up", starting point 1 V, span 8 V.

Допуски та стандарти

  • EMC directive 89/336 EEC: EN 61000-6-2, EN 61000-6-3

Позиції каталогу з цим документом

Текст документа

                                                                European Electronic Controls Catalogue
                                                                                     Catalogue Section E
                                                                                      Product Bulletin VA-7200
                                                                                            Issue Date 1005


                                        VA-7200
                                Electric Valve Actuator




I ntroduction
The VA-720x Series synchronous motor driven
actuator provides floating or proportional control of
valves, with up to 19mm stroke in heating,
ventilation and air conditioning applications.
This compact, non-spring return actuator has a
1000N nominal force and responds to a variety of
input signals.
The VA-7200 Series can be easily field mounted
or ordered factory coupled to VG7000, VG8000,
VG9000 and VGS8000 Series valves in
accordance with the specified maximum close-off
pressure ratings (see pertinent valve bulletins).




                                                                                  VA-7200



                                        Features and Benefits
 ‰ 1000N Force Output compact unit                      Covers a wide range of applications with one actuator

 ‰ Magnetic clutch                                      Provides constant output force for positive close-off of
                                                        valves, and protects motor in stall conditions

 ‰ “Signal fail” safe position                          Valve safety position after control signal failure, the
                                                        safety position, up / down, is selectable in-situ




© 2005 Johnson Controls, Inc.                                                                                     E11
  Order No. 10.736 E
VA-7200                                                                                                           2



O rdering data
For VG7000 Series Valves
                                                          O rdering procedure
                                                          The actuator can be ordered as a separate unit or
                                                          a factory fitted valve-actuator combination. Should
Item Code         Control, Power Supply                   the latter be requested, please just add “+M” to the
                                                          end of the actuator ordering code.
VA-7200-1001      Floating control, 24 VAC supply
                                                          For example:
VA-7202-1001      Proportional control (0…10 VDC /
                  0(4)…20 mA), 24 VAC supply              Item 1 VG7203AT                   (valve body)
For VG8000, VG9000 and VGS8000 Series Valves              Item 2 VA-7202-1001               (actuator)
                                                          Alternatively, to order a factory fitted combination.
Item Code         Control, Power Supply                   Item 1 VG7203AT                   (valve body)
VA-7200-8201      Floating control, 24 VAC supply         Item 2 VA-7202-1001+M             (actuator)
VA-7202-8201      Proportional control (0…10 VDC /
                  0(4)…20 mA), 24 VAC supply




A ctuator / valve combinations                            M ounting instructions
The VA-7200 can be combined with the following            When mounting the actuator on a valve, please
valve ranges:                                             follow the instructions below:
•     VG7000 Series Cast Bronze Valves                    • It is recommended that the valves be mounted
                                                            upright in an easily accessible location. When
•     VG8000 Series PN16 and PN25 Flanged                   mounted horizontally, the yoke should be fitted
      Valves                                                such that the stanchions are aligned vertically,
•     VG9000 Series PN6 and PN10 Flanged                    one above the other.
      Valves
•     VGS8000 Series Male Threaded Valves                                           OK
For complete ordering information, please refer to              90° Max
the relevant product bulletin
                                                                     OK
O peration
Floating control models
    Connections     Actuator Stem         “Signal fail”
                                          safe position
        1-2             extends                N/A
        1-3             retracts               N/A

Proportional control models                               • The actuator must be protected against
(0…10 V or 0…20 mA)                                         dripping water, which could enter the housing
                                                            and damage the mechanism or motor.
Jumper Input control Actuator “Signal fail”
function   signal      Stem    safe position              • Do not cover with insulating material.
  Direct increases   extends    selectable                • Sufficient clearance must be allowed for
 action  decreases    retracts  selectable                  actuator removal (refer to the dimension
Reverse  increases    retracts  selectable                  drawings).
 action  decreases   extends    selectable                • The valve must be installed so that the plug
“Signal Fail” safe position (only for Voltage input)        seats against the flow, as indicated by the
                                                            arrows on the valve.
A signal failure on proportional models will cause
the actuator to automatically move the stem to a
(via jumper) pre-selected position (100% extended
or 100% retracted).

                                                                                                            E11
VA-7200                                                                                            3


W iring instructions                                      WARNING

• All wiring must be in accordance with local        Shock Hazard
  regulations and national electrical codes and
  should be carried out by authorised personnel      Disconnect the power supply before wiring
  only.                                              connections are made to prevent personal injury.
• Make sure that the line power supply is in         Equipment Damage Hazard
  accordance with the power supply specified on      Make and check all wiring connections before
  the device.                                        applying power to the system. Short circuited or
• See also the       instructions   in   paragraph   improperly connected wires may result in
  “Application”.                                     permanent damage to the unit.




Wiring Diagrams:
Floating model 24 VAC




VA-7200-xx01




Proportional model




   VA-7202-xx01




                                                                                                 E11
VA-7200                                                                                                                  4


 A djustments for proportional models
The adjustment procedure varies depending on
                                                                2. Set the direct / reverse action jumper (J1) so
                                                                   that the valve stem travels in the desired
whether voltage or current control is used, taking                 direction (as per changes in control signal)
this into account, to adjust please carry out the                   •   DA (J1 top jumper) stem extends on signal
following instructions:                                                 increase.
1. Set the stroke jumper to match the valve                         •   RA (J1 bottom jumper) stem retracts on
   stroke, this setting is approximate. Jumper                          signal increase.
   location is as depicted below:
                                                                3. Select voltage (V) or current (mA) input signal
Stroke selection jumpers (J5):                                     to match the controller output (if the input
        Jumper 8:      8mm                                         signal selection jumper is removed the
        Jumper 10: 10mm                                            actuator defaults to voltage input).
        Jumper 13: 13mm
        Jumper 19: 19mm                                             Note: When mA input is selected, multiply
                                                                    the “start” and “span” scales by two.
Stroke fine adjustment Starting point Span value                4. Set the signal fail default position to “fully up”,
                                                                   or “fully down”, if the actuator control signal is
           J5           8              4           6

 STROKE
                                                                   lost i.e. an open connection, the actuator will
                       10      2           64               8
                                                                   default to this pre-designated position.
                       13
                       19                                           Note: When mA input is selected, the
                               0           8 2           10         actuator will default to the “low” input signal
                                   START         SPAN               position.
          Action selection
                                                    DA          5. Adjust the potentiometers to the nominal
                                V        A                         values. Set the stroke fine adjustment to
                              J3          J1        RA
                                          J2                       midpoint. Set the starting point (offset) to the
                             J7                                    “low” input signal using the scale printed on
                                      DOWN        UP               the PCB as a reference. Set the span value to
                     1 2 3 4        Failsafe input signal          the “high” input signal minus the offset; see
                                                                   table below. Use the scales for reference.
                            0/10 VDC
                            0/20 mA                             6. Apply the voltage specified by application
                24                                 LED             (RA / DA) requirements to drive the actuator to
                        Com                                        the “fully up” position using the following table.
                 24 Com                                            (If mA input is selected, multiply all values by
                                                                   two).

                                                                Calibration values
VA-72x2 PCB Components                                          Actual                       Reference
                                                                Minimum       Maximum        Minimum         Maximum
The V / A jumper (J3) allows selection of the input             0             10             1               9
signal type as follows:                                         0             5              1               4
                                                                5             10             6               9
                       Volts

                       mA                                           Note: Using the calibration values (± 0.5 V) will
                                                                    ensure proper close-off throughout the life of
                                                                    the valve (takes seat wear into account).

When the voltage input range (J3) is set the                            If the application requires values other
DOWN / UP jumper (J2) allows selection of the                           than those given, use the
actuator “failsafe” stem position as follows:                           minimum actual value + 1 V and the
                                                                        maximum actual value - 1 V
                       DOWN                                             to determine the reference values.
                                                                        •    DA: “fully up” (min. voltage)
                       UP
                                                                        •    RA: “fully up” (max. voltage)
                                                                        When the actuator is in operation the LED
                                                                        will illuminate.
Note: Disconnecting J7 from PCB, the power
supply is interrupted. Therefore the plug must be
in place for actuator operation.



                                                                                                                   E11
   VA-7200                                                                                                                                            5
                                                                                 12. If the “fully down” position cannot be achieved,
   7. Slowly turn the starting point potentiometer
                                                                                     return the stroke potentiometer to the nominal
      clockwise until the valve stem reaches stroke
                                                                                     position and then slowly turn the span
      limit, when the valve stem is in the “fully up”
                                                                                     potentiometer anti-clockwise until “fully down”
      position (the LED will be illuminated and there
                                                                                     is achieved. Repeat step 11.
      should be no gear movement).
                                                                                 13. Adjust the voltage to drive the actuator to “fully
   8. Slowly turn the starting point potentiometer
                                                                                     up” position. Verify starting point adjustment.
      anti-clockwise, stop when the LED flashes or
      goes out.                                                                  14. Check for proper operation using the min. and
                                                                                     max. operating voltages. Allow the actuator to
         Note:       The actuator electronics contain a
                                                                                     complete several operating cycles.
         time-out feature. If calibration takes longer
         than 3…10 minutes, the LED will extinguish,                                 Note:    The LED will remain illuminated for
         falsely indicating a satisfactory condition.                                3…10 minutes after the actuator has
         Should this occur, cycle the power to the                                   completed its operation cycle.
         actuator and readjust the starting point.
                                                                                 15. Refit the cover and secure the screws.
   9. Apply the input voltage requirements specified                                 The unit is now ready for operation.
      by the application (RA / DA) to drive the valve
      stem to the “fully down” position as per chart in                          Factory Settings
      step 6.
                                                                                 The VA-7200 is delivered with the following factory
   10. To ensure that the valve stem is in the “fully                            settings:
       down” position, slowly turn the stroke                                             19 mm stroke
       potentiometer clockwise until the valve stem                                       0…10 V input input signal
       reaches stroke limit (the LED will be on and                                       Direct action
       there should be no gear movement).                                                 Fail safe position “fully up”
                                                                                          Starting point 1 V
   11. Slowly turn the stroke potentiometer anti-
                                                                                          Span            8V
       clockwise, until the LED extinguishes.
                                                                                 The sequencing and action of the actuator are
   A     pplications                                                             individually adjustable on each positioner. Each
                                                                                 positioner has its own adjustment for starting point
   Actuators with built-in positioner for controllers                            between 0…10 V and span between 2…10 V.
   with 0…10V output is sequential operation.                                    Using the minimum adjustable span of 2 V
                                                                                 therefore enables a maximum of 5 sequenced
                                                                                 devices; further sequencing can be accomplished




                                                          To further actuators
                 24V
          24VAC Com Com 0...10V                                                  by using additional controller outputs. Each
      0...10 V
                                                                                 positioner can be switched for direct or reverse
0...10 V Com                                                                     action.
24 VAC Com
      24 VAC

             1 2 3 4              1 2 3 4   1 2 3 4
             Y1                     Y2       Y3


   The controller output 0…10 V can operate several
   actuators with built-in electronic positioner. The                                           Starting   Span    Starting + Span   Positioner
                                                                                                 Point              Point             Action
   electrical wiring for parallel and sequenced
   operation is identical.                                                                         1V       8V           9V             DA
                                                                                                                                             *    * Factory
                                                                                                   1V       3,5V         4,5V          DA         calibration
                                                                                                   5,5V     3,5V         9V            RA




                                                                                          Example of adjustments




                                                                                                                                                    E11
VA-7200                                                                        6



D imensions (in mm)

                                                  0
                                                  0       106
                                                  1




                                                  0
                                                  2
                                                  1




                       8                          8
                       7                          7



          Lock screw                 Lock screw



   VA-7200 for VG7000 Valve Series   VA-7200 for VG8000, VG9000 and VGS8000
               (section)                           Valve Series




                                                                              E11
VA-7200                                                                                                                                  7



S pecifications
                                    Models:                     Floating                         Proportional
                                                                                          0…10 VDC or 0…20 mA
                       Type of motor:                                     Synchronous / reversible
            Supply voltage (50/60 Hz):                         24 V ± 15%                          24 V ± 15%
                                                               50…60 Hz                            50…60 Hz
                           Motor ratings:
                            Actual power                                                       5W
                          Apparent power                                   5.6 VA at 50 Hz          6.7 VA at 60 Hz
        Electronic positioner ratings:                                                                            2 VA
                                                                                                         100 kΩ input impedance
                                                                      -                                       (0…10 VDC)
                                                                                                         500 Ω input impedance
                                                                                                               (0…20 mA)
                   Actuator force:                                          1000 N + 30% - 20%
                           Stroke:                                20 mm maximum; 8, 10, 13, 19 mm selectable
    Nominal speed at 50 Hz (60 Hz):                                            4 (3.2) s / mm
                   Enclosure protection:                                             IP 42 (EN 60529)

                         Materials:
                        Enclosure:                                        Self extinguishing VO-UL 94 ABS + PC
                       Hand wheel:                                               Self extinguishing nylon PA
                             Yoke:                                                   Die cast aluminium
       Ambient Operating condition:                                            -5 to +55, °C, non condensing
        Ambient Storage condition:                                             -20 to +65 °C, non condensing
                 Electrical connections:              2.5 mm2                  2.5 mm2                          1.5 mm2

                                Net weight:                                1.0 kg
                              Compliance: EMC directive 89/336 EEC: EN 61000-6-2, EN 61000-6-3

The performance specifications are nominal and conform to acceptable industrial standards. For application at conditions beyond these
specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products.




Johnson Controls International, Inc.
Headquarters:                            Milwaukee, Wisconsin, USA
European Customer Service Center:        Westendhof 3, D-45143 Essen, Germany
European Factories:                      Essen (Germany), Leeuwarden (The Netherlands) and Lomagna (Italy)
Branch Offices                           Principal European Cities.




                                                                                                                                        E11
