Graphics+ Catalog Page
MS-GGT-0, MS-GGT-6 Code No. LIT-1900689
Software Release 1.3
Issued December 5, 2014
Graphics+ is a data visualization software package designed for • Summary Data of Multiple Buildings in a Single Graphical View
Metasys® system customers who are looking for a quick way to create with Navigational Aids
interactive building data representations, thus empowering them to • Ability to Quickly and Easily Switch from Tabular to Graphical Views
visualize, analyze, and respond to problems faster. The Graphics+
software package comprises two components: the Graphic Generation • Stand-Alone Graphic Generation Tool
Tool (GGT) and the Graphics+ Viewer. • Extensive Library of Prebuilt Dynamic Symbols and Templates
The Graphic Generation Tool is a simple yet powerful diagramming • Dynamic Symbol Capabilities, Including Commanding, Flashing,
tool that helps designers create compelling representations of their Changing Color, Showing and Hiding Elements, Navigation, and
building equipment and floor plans and bind them to Metasys data Context Menus, for Enhanced User Experience
objects. The tool includes an extensive library of pre-built symbols and • HVAC Library Elements Pre-Populated with Aliased Binding Strings
templates, shortcut keys, and right-click functions, giving designers • Historical Trend Information Available Directly within a Graphic
the ability to assemble graphics faster. The tool also provides
• Computer Aided Drafting (CAD) File Import Capability
flexibility to create customized graphics using a rich set of effects
known as behaviors. Behaviors allow users to command, navigate, • Right-Click Functions, Short-Cut Keys, and User-Configurable
change color, apply flash, set visibility, and display a context menu for Symbols Properties
bound Metasys objects. You can save these graphics directly to a • Comprehensive Representation of Facility Support Systems
supported Metasys Host, such as a Site Director or a System
• Multiple Language Support
Configuration Tool (SCT) archive database.
• Optimal Graphics Display Performance
With the GGT, you can easily create a graphic of status summaries for
each monitored system or space (for example, building, floor, or floor
group). The graphic uses color to summarize the overall condition of Figure 1: Graphics+ Example
monitored points. In one quick glance, you can view the number of
warnings, alarms, or offline items across your entire facility or campus.
By clicking any one of these spaces or systems, you can see a detailed
view of the monitored equipment. You can also open historical data for
any trended point within the graphic using the Trend Module. The Trend
Module can show trend data for up to four points at once for system
diagnosis and comparison purposes. Additionally, using the predefined
set of gauges, you can create an energy dashboard graphic that quickly
conveys the current state of energy savings in your facility.
The Graphics+ Viewer is integrated with the Site Management Portal
(SMP), SCT, and Ready Access Portal, allowing users to show,
command, or update in real time all the data linked objects that were
created in the GGT. The graphical display gives you a three-dimensional
view of your facility, offering an intuitive way to manage the daily events
of your buildings or campus.
Refer to the Graphics+ Feature Product Bulletin (LIT-12011698) for
important product application information.
Features
• Thermographic Display of Temperature Conditions of a Floor
• Easy and Consistent Access to Room Information
Technical Specifications
Table 1: Graphic Generation Tool System Requirements
Product MS-GGT-0 (new Graphic Generation Tool software)
MS-GGT-6 (upgrade Graphic Generation Tool software)
Recommended Computer Platform
1 Intel® Core™ 2 Duo E6700 or better (Intel Core 2 Duo E4300 minimum)
100 MB recommended free hard disk space available
DVD drive
Memory 4 GB RAM recommended (2 GB RAM minimum)
Graphics+ Catalog Page 1
Table 1: Graphic Generation Tool System Requirements
Operating System Windows 8.1 and Windows 8.1 Enterprise Editions (64-bit)
Windows 8 and Windows 8 Enterprise Editions (64-bit)
Windows® 7 Professional, Enterprise, or Ultimate Editions with SP1 (32-bit and 64-bit)
Windows Server 2012 R2 (64-bit)
Windows Server 2012 (64-bit)
Windows Server 2008 R2 with SP1 (64-bit)
Windows Server 2008 with SP2 (32-bit)
Other Software Microsoft .NET Framework 4.0 (required for creating Graphics+ graphics; included on the GGT product disk)
Note: We recommend you install the full version of Microsoft .NET Framework 4.0.
Communication Ethernet network interface card 10/100/1,000 Mbps (100 Mbps network recommended)
Note: We recommend a wired connection.
Wireless 802.11 connection
1 Our computer platform and memory recommendations are not meant to imply that older or slower machines are not usable. Refer to the Network and IT Guidance
for the BAS Professional Technical Bulletin (LIT-12011279) for more information regarding computer/server recommendations.
Table 2: Graphics+ Viewer System Requirements
Product Graphics+ Viewer built into Site Management Portal UI, SCT UI, and Ready Access Portal UI
Recommended Computer Platform
12 Intel® Core™ 2 Duo E6700 or better (Intel Core 2 Duo E4300 minimum)
Memory 4 GB RAM recommended (2 GB RAM minimum)
Operating System Windows 8.1 and Windows 8.1 Enterprise Editions (64-bit)
Windows 8 and Windows 8 Enterprise Editions (64-bit)
Windows® 7 Professional, Enterprise, or Ultimate Editions with SP1 (32-bit and 64-bit)
Windows Server 2012 R2 (64-bit)
Windows Server 2012 (64-bit)
Windows Server 2008 R2 with SP1 (64-bit)
Windows Server 2008 with SP2 (32-bit)
Apple® OS X® 10.8 Mountain Lion
Apple® OS X® 10.9 Mavericks
Note: Apple operating systems are supported for Metasys client computers only.
Note: In OS X, you cannot view Graphics+ graphics in the Site Management Portal UI.
Other Software Windows Internet Explorer® Version 8, 9, 10, or 11
Note: In Internet Explorer 11, select the Use Microsoft compatibility lists option, found under Tools > Compatibility View
Settings, to ensure that websites appear and function correctly.
Microsoft Silverlight 5.0 or higher (available as a free download from Microsoft Corporation.)
Apple® Safari version 6.0.5 and 7.0
(Other browsers, such as Google® Chrome and Mozilla Firefox, may also be used but are not fully supported.)
Communication Ethernet network interface card 10/100/1,000 Mbps (100 Mbps network recommended)
Note: We recommend a wired connection.
Wireless 802.11 connection
1 For large graphics, rendering the image is CPU intensive. In general, a higher performing CPU with multiple cores is recommended.
2 Our computer platform and memory recommendations are not meant to imply that older or slower machines are not usable. Refer to the Network and IT Guidance
for the BAS Professional Technical Bulletin (LIT-12011279) for more information regarding computer/server recommendations.
Building Efficiency
507 E. Michigan Street, Milwaukee, WI 53202
Metasys® and Johnson Controls® are registered trademarks of Johnson Controls, Inc.
All other marks herein are the marks of their respective owners.© 2014 Johnson Controls, Inc.
Published in U.S.A. www.johnsoncontrols.com
Graphics+ Catalog Page 2Позиції каталогу з цим документом
Документ виробника, опублікований як довідковий матеріал на обладнання, яке ми постачаємо. Правовласник може попросити прибрати його — приберемо.