FX16 Master Controller Product Bulletin
Issued May 8 2007
FX16 Master Controller
The FX16 Master Controller is a high performance The FX16 Master Controller is fully configurable or
field controller in the Facility Explorer platform. The programmable, using the FX Tools software package,
FX16 is designed for commercial Heating, Ventilating, for a wide range of commercial HVAC and
Air Conditioning, and Refrigeration (HVACR) refrigeration applications.
applications, such as chillers, rooftop units, packaged
air conditioning units, Air Handling Units (AHUs), and N2 Open or LONWORKS® communication cards are
close control units, as well as small distributed control available with the FX16 Master Controller for the
systems with terminal units. integration of the controller into a compatible Building
Automation System (BAS).
The FX16 has 27 physical inputs and outputs and
supports a wide range of temperature sensors and
actuator devices. Up to 64 additional physical inputs
and outputs can be added using XT/XP expansion
modules. The FX16 can manage a distributed control
application with up to 16 slave FX controllers (FX05,
FX06, FX07, FX14, or FX15). The FX16 can also
monitor and control a number of N2 Open compatible
devices through its gateway feature. Parameters in a
distributed control application can be displayed and
modified from optional integral or remote user
interfaces.
The FX16 also features communications services to
transmit event notification text messages via Short Figure 1: FX16 Master Controller
Messaging Service (SMS) or by e-mail. With its
onboard Web server, you can browse and make
adjustments to the application from a remote location.
Features and Benefits
Optional Integral or Remote User Provide a clear presentation of control system data on a
Interfaces (UIs) menu-driven, scrolling, 4 line by 26 character Liquid Crystal
Display (LCD) with backlight.
Distributed Control Application Provides the ability to control complex systems by coordinating the
activities of multiple controllers in a single application.
Embedded Web Server Allows remote access to the data in the control system via a Web
browser and modem connection to the FX16 Master Controller.
Communication Services Provide automatic reporting of events and alarms by e-mail or by
Short Message Service (SMS) with optional acknowledgement.
Network Communications Provide a cost effective method for stand-alone or networked
Options – N2 Open and operation.
LONWORKS Protocol
Continued on next page . . .
© 2007 Johnson Controls, Inc. 1
Code No. LIT-12011084
Features and Benefits (Cont.)
Freely Programmable or Is suitable for a wide range of applications for environmental and
Configurable Using FX Tools refrigeration control using the extensive programming features of
the FX Tools software package.
Onboard Trend and Event Provide the necessary information for analyzing the control system
Logging performance and diagnosing fault conditions.
Analog Input Types Selected in Allows choice of temperature and other sensors according to the
Software control range and application.
2 FX16 Master Controller Product Bulletin
The FX16 Master Controller provides the formatted
Onboard Inputs and Outputs (I/Os) data for the requested pages starting with a home
Up to 27 physical inputs and outputs can be page from which other pages can be requested. Each
connected to the FX16 Master Controller, including: page may contain graphic images, links to the other
pages, and data windows for the display of live data
• 6 Analog Inputs (AIs) – software configurable from the control system.
• 8 Digital (Binary) Inputs (DIs) – for voltage free The active values are transmitted by the embedded
contacts Web server in the FX16 Master Controller to the
screen of the computer. Typically up to 16 values can
• 9 Digital (Binary) Outputs (DOs)
be continuously updated on one page and the user
− 9 relays with 230 VAC contacts or may adjust or override values on the screen. Access
to the Web pages is protected by a password system
− 4 relays and 5 opto-isolated Triacs for 24 VAC to prevent unauthorized data access and control
• 4 Analog Outputs (AOs) – 0 to10 VDC actions.
In summary, the Web server interface provides the
Scalable I/O Expansions following features from any computer directly
The input/output capacity of the FX16 Master connected to the FX16 Master Controller or has
Controller may be extended by connecting up to four access to the telephone system. The Web server
XT extension modules via the Local Link Bus. interface:
Expansion Modules (XPs) provide input and output • displays live variables in the monitored control
capabilities for the XT extension modules, as follows: system
• XT91D00 Processor/Communication Module • adjusts and commands variables in the control
system
• XP91D02 6 universal AIs + 2 AOs
• displays and acknowledges active alarms
• XP91D03 8 DOs (triacs)
• displays the event history log
• XP91D04 4 DIs + 4 DOs (triacs)
• displays trended data values and copy/paste to
• XP91D05 8 DIs Microsoft Excel spreadsheet for storage and
further processing
• XP91D06 4 DOs (relays) 230 VAC (Europe only)
• enables and disables trend logs
• XP91D07 4 DOs (relays) 24 VAC
(North America only) • reads and modifies communication parameters
including e-mail addresses, telephone numbers,
Embedded Web Server and Web and others
Page Access
The FX16 Master Controller features an embedded
Web server that enables a local or remote user to
establish communication with the FX16 Master
Controller from a computer and to browse live control
data, active alarms and events, trend data, and
configuration parameters. This feature provides an
effective, low-cost monitoring system without the need
for any special or proprietary supervisory software.
The Web pages are accessed using a direct serial line
or telephone modem connection and the Point-to-Point
Protocol (PPP) from any computer with Microsoft®
Internet Explorer software that serves as a Web
browser. Figure 2: Web Page with Trend Data
FX16 Master Controller Product Bulletin 3
Communication Services Alternatively, if the user has access to a computer with
Web browser and modem connection, the control
The FX16 Master Controller can be programmed to system can be viewed on the Web pages that have
send out e-mail and/or Short Message Service (SMS) been generated in the FX16 Master Controller.
text messages when connected to a modem and
telephone line or to a GSM modem with an You can also use the e-mail service to periodically
appropriate transmitter and antenna. E-mail messages send trend log data to a remote e-mail receiver for
are directed to an Internet Service Provider (ISP) that electronic storage and to prevent the loss of data in
offers an e-mail forwarding service. SMS messages the FX16 Master Controller when the trend buffer
can be sent to a service center or directly to a mobile is full.
telephone. Messages are sent when an event goes
into the active or alarm state and can be directed to a
prioritized list of destinations.
Figure 3: Communication Services
4 FX16 Master Controller Product Bulletin
Another benefit of a distributed application is the ability
Distributed Application to combine FX controllers to achieve the inputs and
A distributed application is a control strategy managed outputs required for the physical equipment interface.
by the FX16 Master Controller but is executed The application is automatically distributed and
concurrently in the FX16 Master Controller and in up to executed in the individual controllers forming a single
16 FX slave controllers connected to the Local Link control system.
Bus. The communication between the controllers is
defined by network variables in the distributed Gateway Feature
application and the FX16 Master Controller executes
The latest versions of the FX16X Master Controller
the communication in the most effective way to
feature a Gateway object. The Gateway object allows
maintain the performance of the entire control system.
the FX16 to monitor up to 16 N2 Open devices (that
Distributed applications are used for the coordinated are not slaves in a Distributed Application) on the
control of a central plant and the remote equipment Local Link Bus. These devices can be FX controllers
that it serves. For example, a distributed application fitted with an N2 Open communication card, Metasys®
could be applied to an FX16 Master Controller Application Specific Controllers (ASCs) (UNT, VAV,
controlling an air handling unit, an FX14 controller AHU), Metasys compatible N2 Open Vendor (VND)
controlling a chiller unit, and a number of FX07 devices, or System 91 N2 devices (DX-9100 and
controllers controlling zone terminal units or fan coil TC-910x).
units.
Figure 4: Distributed Application
Supervisory Options LONWORKS Network
When fitted with a LONWORKS Communication Card,
You can integrate the FX16 Master Controller into a
the FX16 can communicate peer-to-peer with other
supervisory Building Automation System (BAS) for
LONWORKS compatible devices and provide data
continuous monitoring of the control system. The FX16
access to a supervisory system.
Master Controller supports two methods of integration:
N2 Open and LONWORKS network.
N2 Open Network
When fitted with an N2 Open Communication Card,
the FX16 can connect to an N2 Open compatible BAS,
providing access to control system variables and
parameters.
FX16 Master Controller Product Bulletin 5
Time Scheduling When an event goes into the active state, it is entered
into the table of active events and the event history log
The FX16 Master Controller has an embedded
with the time and date of occurrence, and a message
real-time clock that supports all real-time functions
window appears on the display screen. The event can
including the time and date display on the integral and
also be configured to send a text message to one or
remote displays, the time stamping of events, and
more of the following:
trend data. The real-time clock also enables the time
scheduling of start, stop, and occupancy commands • E-mail Message Server
for the plant being monitored and controlled. • Mobile Telephone with Short Message Service
Scheduled commands may be configured to execute (SMS)
on one or more days of the week, and an exception
day calendar allows for alternative time schedules on The system only removes the events from the table of
holidays or during special periods in the year. active events when you acknowledge the event and
the event returns to an inactive or normal state. You
Time schedules may be displayed and edited on the can acknowledge events from any of the connected
available user interfaces or in a Web page on a Web user interfaces. Displays and the Web page have
browser screen. The real-time clock is battery backed password protection. You can view the table of active
with an average battery life of more than 2 years. events and the event history log on the integral or
remote displays or on the Web browser screen.
Data Trend Logging
The FX16 Master Controller can be configured to
record data samples at a defined interval for up to
40 variables within the control application. The sample
interval is defined for each variable and can be set
from every minute to once per day. In the latest
LP-FX16X Rev. A version, the onboard memory can
store trend log samples from 40 variables at 15 minute
Figure 5: Occupancy Schedule Definition
intervals for up to 100 days.
Alarm and Event Management You can view trend data for each variable within a
specified time period in text format on the connected
The FX16 Master Controller manages and records
user displays. You can also view trend log data from a
events or errors that are generated by the operating
Web browser; this allows you to copy and paste trend
system and events or alarms that are associated with
information into a spreadsheet application, such as
data points or variables in the control application.
Excel for further processing and electronic storage.
System events indicate to the user that the control
You can transmit trend logs at regular intervals, from
system requires some attention and include events
1 hour to every day via the telephone modem
such as:
connection to an e-mail server. You can also upload
• system power up Trend data with FX CommPro. FX CommPro then
• trend buffer full converts the data into a standard format for transfer to
a computer.
• communication message failure (E-mail, SMS)
A system event message is generated if the trend
• device communication error
buffer is not configured in the circular recording mode
• application or display diagnostic error and the buffer becomes full.
Application events or alarms indicate to the user that
the controlled equipment requires attention or that the User Interfaces
controlled conditions are not within the expected limits. The FX16 Master Controller supports two user
For example: interfaces, which can be integral and remote. These
• Analog value is outside of a desired range. user interfaces feature a 4 line by 26 character Liquid
Crystal Display (LCD), 6 push buttons, and 10 discrete
• Status value represents a condition that is not status Light-Emitting Diodes (LEDs). The display and
normal. navigation menus are fully programmable within the
control application using FX Builder.
6 FX16 Master Controller Product Bulletin
The integral Medium User Interface (MUI) is built into FX Tools Software
the front face of the FX16, allowing direct access to
the control system’s points. FX16 models are available The FX Tools software suite is used to program,
with and without the Integral MUI. download, test, and commission the FX devices,
including the FX16. FX Tools is available on CD in two
Two versions of the remote Medium User Interface are versions: FX Tools Pro and FX Tools Express
available for panel or wall mounting: (North America only).
• LP-DIS60P20-0C: You can mount this MUI within
FX Tools Pro CD includes:
a panel up to 3 m (10 ft) from the FX16. This user
interface is powered by the FX16. The LP-KIT007- • FX Builder – used to fully program an FX16.
000C is a flat telephone cable needed to connect FX Builder provides complete flexibility in
a power supply and data communications to the programming the FX16.
FX16.
• FX CommPro N2 – used to download, test, and
• LP-DIS60P21-0C: You can mount this MUI within commission an FX16 on an N2 Open network
a panel or on a wall surface up to 300 m (1,000 ft)
from the FX16. This user interface must be • FX CommPro LON – used to download, test, and
independently powered. The data communication commission an FX16 on a LONWORKS network
requires a 3-wire shielded cable (not provided) • FX Builder Express – used to select an FX16
connected to the FX16’s Remote Display application and configure it using graphical
connection. plug-ins (North America only).
The FX Builder Express CD does not include
FX Builder (North America only).
Application Upload/Download
With the FX16, you can download and upload a full
application file to and from the latest LP-FX16X Rev. A
version using a computer with the FX CommPro N2
Figure 6: Medium User Interface tool software. This way, the controller contains all the
information for you to retrieve, view, and modify the
application in FX Builder if the archived version of the
Multi-language Database file is not available. You can only download earlier
All the text on the available User Interfaces is fully versions of the controller with the application operating
programmable and can be entered in up to five code using FX CommPro, and the full application file
different languages. remains in the FX Builder archive.
The user is then able to select the preferred language
from the display menu when logging into the system.
This feature has been designed for systems intended
for installation in many countries in the world or for
areas where more than one language is spoken.
FX16 Master Controller Product Bulletin 7
Dimensions in mm (in.)
215 (8.46) 49 (1.93)
For Omega Rail DIN/EN 50022 Mounting
142 (5.59) 122 (4.8) DIN RAIL
B B
FX16-003_09 2003
Figure 7: FX16 Master Controller Dimensions
8 FX16 Master Controller Product Bulletin
Ordering Codes
Table 1: FX16 Master Controller - Standard Temperature Range Ordering Information
Product Code Description
LP-FX16D00-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (9 relays), no communications card
LP-FX16D01-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (9 relays), N2 Open communications card
LP-FX16D02-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (9 relays), LON communications card
LP-FX16D03-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (9 relays), RS-232 communications card
LP-FX16D10-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (4 relays, 5 triacs), no communications card
LP-FX16D11-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (4 relays, 5 triacs), N2 Open communications card
LP-FX16D12-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (4 relays, 5 triacs), LON communications card
LP-FX16D13-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (4 relays, 5 triacs), RS-232 communications card
Table 2: FX16 Master Controller - Extended Temperature Range Controllers (Rev. A) Ordering Information
Product Code Description
LP-FX16X00-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (9 relays), no communications card
LP-FX16X01-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (9 relays), N2 Open communications card
LP-FX16X02-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (9 relays), LON communications card
LP-FX16X03-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (9 relays), RS-232 communications card
LP-FX16X50-000C FX16, with display, 6 AIs, 8 DIs, 4 AOs, 9 DOs (9 relays), no communications card
LP-FX16X51-000C FX16, with display, 6 AIs, 8 DIs, 4 AOs, 9 DOs (9 relays), N2 Open communications card
LP-FX16X52-000C FX16, with display, 6 AIs, 8 DIs, 4 AOs, 9 DOs (9 relays), LON communications card
LP-FX16X53-000C FX16, with display, 6 AIs, 8 DIs, 4 AOs, 9 DOs (9 relays), RS-232 communications card
LP-FX16X10-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (4 relays, 5 triacs), no communications card
LP-FX16X11-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (4 relays, 5 triacs), N2 Open communications card
LP-FX16X12-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (4 relays, 5 triacs), LON communications card
LP-FX16X13-000C FX16, 6 AIs, 8 DIs, 4 AOs, 9 DOs (4 relays, 5 triacs), RS-232 communications card
LP-FX16X60-000C FX16, with display, 6 AIs, 8 DIs, 4 AOs, 9 DOs (4 relays, 5 triacs), no communications card
LP-FX16X61-000C FX16, with display, 6 AIs, 8 DIs, 4 AOs, 9 DOs (4 relays, 5 triacs), N2 Open communications card
LP-FX16X62-000C FX16, with display, 6 AIs, 8 DIs, 4 AOs, 9 DOs (4 relays, 5 triacs), LON communications card
LP-FX16X63-000C FX16, with display, 6 AIs, 8 DIs, 4 AOs, 9 DOs (4 relays, 5 triacs), RS-232 communications card
FX16 Master Controller Product Bulletin 9
Table 3: FX16 Communications Cards (for Upgrade or Replacement) Ordering Information
Product Code Description
LP-NET151-010C N2 Open communication card for LP-FX16D and LP-FX16X (not Rev. A) controllers
LP-NET161-000C N2 Open communication card for LP-FX16X Rev. A controllers
LP-NET152-010C LON communication card for LP-FX16 controllers
LP-NET163-000C RS-232 communication card for LP-FX16 controllers
Table 4: User Interfaces Ordering Information
Product Code Description
LP-DIS60P20-0C Medium User Interface for FX16 (non-isolated version); Can be mounted up to 3 m (10 ft) from the
FX16 and includes panel mounting hardware.
LP-DIS60P21-0C Medium User Interface for FX16 (isolated version); Can be mounted up to 300 m (1,000 ft) from the
FX16 and includes panel and wall mounting hardware.
Table 5: Accessories Ordering Information
Product Code Description
LP-KIT007-000C Interface cable 3 m (9.8 ft) for Medium User Interface (LP-DIS60P20-0C) to FX16
LP-KIT007-001C Interface cable for standard modem to FX16
LP-KIT007-013C Null modem cable, 3 m (9.8 ft)
LP-KIT007-014C Null modem cable, 15 m (49 ft)
Table 6: FX16 Accessories - Only Available in Europe Ordering Information
Product Code Description
LP-KIT007-002C Interface Cable (1.5 m/4.9 ft) for GSM modem to FX16 and Master Display
LP-KIT090-000C GSM 900/1800 FastTrack Modem
LP-KIT090-001C GSM Modem Plug-in Antenna
LP-KIT090-003C GSM Modem Magnetic Mount Antenna with 2.5 m Cable
LP-KIT090-004C GSM Modem Panel Mount Antenna with 5 m Cable
LP-KIT090-005C GSM Modem Power Adapter, 230 VAC/12 VDC, Wall Plug
LP-KIT015-001C Kit of Female Cage Clamp Connectors
Table 7: FX16 Demonstration Cases Ordering Information
Product Code Description
LP-FX16DEM-051C Demo Case with FX16 Master Controller, display, 9 relays, N2 Open card – 230 VAC power
LP-FX16DEM-052C Demo Case with FX16 Master Controller, display, 9 relays, LON card – 230 VAC power
LP-FX16DEM-053C Demo Case with FX16 Master Controller, display, 9 relays, RS-232 card – 230 VAC power
LP-FX16DEM-061C Demo Case with FX16 Master Controller, display, 9 relays, N2 Open card – 120 VAC power
LP-FX16DEM-062C Demo Case with FX16 Master Controller, display, 9 relays, LON card – 120 VAC power
LP-FX16DEM-063C Demo Case with FX16 Master Controller, display, 9 relays, RS-232 card – 120 VAC power
10 FX16 Master Controller Product Bulletin
Table 8: Expansion I/O Modules Ordering Information
Product Code Description
LP-XT91D00-000C Facility Explorer Extension Module
LP-XP91D02-000C Facility Explorer Expansion Module - 6 AI, 2 AO
LP-XP91D03-000C Facility Explorer Expansion Module - 8 DO (triacs)
LP-XP91D04-000C Facility Explorer Expansion Module - 4 DI, 4 DO (triacs)
LP-XP91D05-000C Facility Explorer Expansion Module - 8 DI
LP-XP91D06-000C Facility Explorer Expansion Module - 4 relays, 230 VAC 3 A (Europe Only)
LP-XP91D07-000C Facility Explorer Expansion Module - 4 relays, 24 V 3 A (North America Only)
Table 9: Software Tools Ordering Information
Product Code Description
LP-FXTPRO-0 FX Tools Pro CD (FX Builder, FX Builder Express, FX CommPro N2, LON) - New User
LP-FXTPRO-6 FX Tools Pro CD (FX Builder, FX Builder Express, FX CommPro N2, LON) - Upgrade
LP-FXTEXP-0 FX Tools Express CD (FX Builder Express, FX CommPro N2) (North America only)
FX16 Master Controller Product Bulletin 11
Technical Specifications
Table 10: I/O Details
Terminal Block Channel Type Remark/Application
Analog Input (AI)
TB1 AI1, AI2, AI3, See following table. Software configurable
AI4, AI5, AI6 16 bit resolution Application: temperature, humidity, and pressure
EXT-VDC +16 V, 80 mA 0-10 V sensors or max. 4 0/4 - 20 mA sensors
AVPS/EXT- AVPS = +5 V, Directly power ratiometric sensors with AVPS, or
VDC 20 mA 0-10 V, 0/4 - 20 mA sensors with EXT-VDC
EXT-VDC = +16 V, AVPS or EXT-VDC selected by jumpers.
80 mA
Digital Input (DI)
TB2 DI1, DI2, DI3, Potential free Transition counter at 50 Hz max.
DI4, DI5, DI6, contacts Minimum time ON: 10 ms. Minimum time OFF: 10 ms
DI7, DI8 Prescaler function: max. division by 100
DI V~ Hot 24 VAC FX16 (not Rev. A): for isolation of DIs from the
DI V~ Com microprocessor, a separate 24 VAC power supply is required.
Digital Output (DO)
TB3 DO1, DO2, SPST 8(3)A power Max. switching power (relays):
DO3 relays Motor: 240 W, 0.5 hp, 250 VAC
Rating (resistive): 8A 125 VAC
8A 30 VDC
8A 250 VAC
UL tested life (min. operations): 30,000 operations
(at 360 operations x hour)
Dielectric strength coil-contacts: 4000 V RMS for 1 minute
TB4 DO4, DO5 SPST 5(3)A power Max. switching power (relays):
relays or Motor: 150 W, 0.25 hp, 250 VAC
0.5 A/24 VAC triacs Rating (resistive): 5 A 125 VAC
TB5 DO6, DO7, SPST 5(3)A power 5 A 30 VAC
DO8 relays or 5 A 250 VDC
0.5 A/24 VAC triacs UL tested life (min. operations): 30,000 operations
(at 360 operations x hour)
Dielectric strength coil-contacts: 4000 V RMS for 1 minute
TB6 DO9 SPDT NC 8(3)A Same as TB3 relays
250 V relay Fail relay for enhanced security. The relay returns to its
Network Controller (NC) position not only at power fail but also
in case the microprocessor should fail: for example, watch-dog
or brown-out.
Analog Output (AO)
TB7 AO1, AO2 0 -10 VDC Used to drive analog actuators, frequency drives; 16 bit
FX16D/FX16X: resolution.
1.5 mA
FX16X Rev. A: 5 mA
TB8 AO3, AO4 0 -10 VDC Used to drive analog actuators, frequency drives; 16 bit
FX16D/FX16X: resolution.
1.5 mA
FX16X Rev. A: 5 mA
AO V~ Hot 24 VAC FX16 (not Rev. A): for isolation of AOs from the
microprocessor a separate 24 VAC power supply is required.
12 FX16 Master Controller Product Bulletin
AO V~ Com
Table 11: Analog Sensor Types
Sensor Type Linearization Range Accuracy at 20°C (68° F)
Ambient
Ni1000 JCI -45°C (-49°F) to 120°C (248°F) ±0.5°C (±1°F)
Ni1000 JCI Extended Range 20°C (68°F) to 287°C (548.6°F) ±0.5°C (±1°F)
Ni1000 Siemens® (L&G) -50°C (-58°F) to 160°C (320°F) ±0.5°C (±1°F)
Ni1000 DIN -60°C (-76°F) to 180°C (356°F) ±0.5°C (±1°F)
Pt1000 -50°C (-58°F) to 605°C (1,121°F) ±0.5°C (±1°F)
A99 -50°C (-58°F) to 110°C (230°F) ±0.5°C (±1°F)
NTC 2.25 k -40°C (-40°F) to 150°C (302°F) ±0.5°C (±1°F)
NTC 10 k -40°C (-40°F) to 150°C (302°F) ±0.5°C (±1°F)
0 to 5 VDC Ratiometric 10 to 90% of supply voltage (0.5 to 4.5 V ±0.05 VDC
nominal)
Active 0 to 10 VDC 0 to 10 Volts ±0.05 VDC
Active 0 to 20 mA 0 to 20 mA ±0.1 mA
FX16 Master Controller Product Bulletin 13
FX16 Master Controller Standard and Extended Range Models
Product FX16D Master Controller
FX16X Rev. A Master Controller Extended Temperature Range
Power Supply Requirements 24 VAC ±15%, 50/60 Hz - Class 2 Power Supply – Safety Extra-Low Voltage (SELV)
in Europe
Power Consumption 15 VA at max. load
Internal Fuse 2 A, 250 V
Protection Class IP 20
Ambient Operating Conditions FX16D: -20°C (-4°F) to +50°C (122°F) ,10 to 95% RH (noncondensing)
FX16X Extended Temperature Range: -40°C (-40°F) to +60°C (140°F) ,10 to 95%
RH (noncondensing) (Integral Display may not operate below -20°C [-4°F])
Ambient Storage Conditions -40°C (-40°F) to +70°C (158°F), 10 to 95% RH (noncondensing)
Dimensions (H x W x D) 142 x 215 x 49 mm (5.6 x 8.5 x 1.9 in.)
Weight (with package) 0.74 kg (1.6 lb)
Connection Terminals for Signals Screw terminals for max 1 x 1.5 mm2 (16 AWG) wires
and Power Supply
2
N2 Open Bus Connection Screw terminals, cable size 0.5 mm to 1.5 mm , 24 AWG to 16 AWG, Belden cable,
Terminals 4-core twisted pair with shield
2
LON Network Connection Screw terminals, cable size 0.5 mm to 1.5 mm , 24 AWG to 16 AWG, Belden cable,
Terminals 2-core twisted pair with shield
2
Connection for Extension Bus Screw terminals, cable size 0.5 mm to 1.5 mm , 24 AWG to 16 AWG, Belden cable,
and Remote Display 4-core twisted pair with shield
Compliance Europe – 89/336/EEC, EMC Directive: EN 61000-6-3, EN 61000-6-1
– 72/23/EEC, Low Voltage Directive: EN 60730
Canada – UL Listed (PAZX7), CAN/CSA C22.2 No. 205, Signal Equipment
– UL Recognized (XAPX8), CAN/CSA C22.2 No. 24, Temperature
Indicating and Regulating Equipment
– Industry Canada, ICES-003
United – UL Listed (PAZX), UL 916, Energy Management Equipment
States – UL Recognized (XAPX2), UL 873, Temperature Indicating and
Regulating Equipment
– FCC compliant to CFR 47, Part 15, Subpart B, Class A
The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these
specifications, contact a Facility Explorer technical support resource. Johnson Controls, Inc. shall not be liable for damages resulting from
misapplication or misuse of its products.
Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the interference at his/her own expense.
Industry Canada (IC) Statement
This Class (A) digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la Classe (A) respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Controls Group Global Headquarters
507 E. Michigan Street
P.O. Box 423 Published in U.S.A. and Europe
Milwaukee, WI 53201
14 FX16 Master Controller Product BulletinПозиції каталогу з цим документом