F93 Series Air Volume Controls for Deep Wells
Product/Technical Bulletin
Part No. 24-7664-3000, Rev. A
Issued October 2018
The F93 Series Air Volume Controls for Deep Wells
control the amount of air in the residential water
storage tanks of deep well water systems. Deep wells
are more than 25 ft (7.6 m) deep.
F93 Series Controls automatically maintain air volume
in the storage tanks of deep well water systems by
allowing air to escape from the tank and into the
surrounding room when the water level in the tank
drops (increase of air volume).
F93 deep well controls open the air valve on a fall in
tank water level to bleed excess air from the tank at
pressures up to 100 psig (690 kPa).
The F93H has a minimum pressure release valve to Figure 1: F93B Air Volume Control
avoid lowering tank pressure below 25 psig (172 kPa). for Deep Wells
Use this model on applications where water may be
rapidly drained.
Table 1: Features and benefits
Features Benefits
Sturdy Noryl (high performance thermoplastic) body Resists mechanical damage and corrosion.
Brass internal operating parts Minimize corrosion.
Pressure tested plastic float Provides long operating life.
Optional pressure gauge tapping Allows mounting of a pressure gauge.
Certification for Federal Safe Drinking Water Act Meets the US Federal standards of the Reduction of Lead in
Drinking Water Act.
F93 Series Air Volume Controls for Deep Wells Product/Technical Bulletin
1
Application Install the control in the tank as follows:
1. If you are using Teflon® thread sealing tape, wrap
IMPORTANT: Use this F93 Series Air Volume
the 1-1/4 in. NPT threads on the control. Overlap
Control for Deep Wells only as an operating control.
the tape half its width to make two layers, and
Where failure or malfunction of the F93 Series Air
continue to where the thread ends at the large end.
Volume Control could lead to personal injury or
If you are using pipe sealant instead of Teflon tape,
property damage to the controlled equipment or
apply a generous amount of sealant to the male
other property, additional precautions must be
threads.
designed into the control system. Incorporate and
maintain other devices, such as supervisory or 2. Using a wrench on the flat sides of the control
alarm systems or safety or limit controls, intended to body, screw the control into a tank opening located
warn of or protect against failure or malfunction of about 2/3 of the way up.
the F93 Series Air Volume Control.
Note: The tank must have a diameter of at least 9 in.
(229 mm) to allow room for the float to operate.
Water storage tanks in residential water systems rely
on a volume of air in the tank to provide system
IMPORTANT: Tighten (not overly tight) with the air
pressure, making it important to control the amount of
valve and assembly pointed down. Ensure that the
air in the tank:
wrench does not slip and damage the air valve
• Too little air in the tank results in rapid pump cycling casing assembly.
- a problem common in shallow well systems (less
than 25 ft [7.6 m] deep). F93B and F93H models
The F93B and F93H models have a 1/4 in. tapped
• Too much air in the tank results in air entering the
opening for a pressure port at the top of the control.
distribution system - a problem common in deep
well systems (more than 25 ft [7.6 m] deep). When you install a gage into this pressure port, wrap
two turns of Teflon thread sealing tape around the male
For information on air volume controls for shallow
threads of the gage. Overlap the tape half its width to
wells, refer to the F92 Series Air Volume Controls for
make two layers. If you are using pipe sealant instead
Shallow Wells Product/Technical Bulletin
of Teflon tape, apply a generous amount of sealant to
(Part No. 24-7664-2993).
the male threads.
Installation
IMPORTANT: Use only Teflon® thread sealing tape
or pipe sealant that is compatible with plastic. Pipe
sealant meant for use with metal may corrode the
plastic body, causing it to crack.
1-1/4
(32)
FIG:F93_dmnsns
6-11/16
(171)
1-3/8 (35) 2-11/16
Diameter (68)
1/4
(6)
1-3/16
13/16
(30)
(21)
1-11/16
3-1/2
(43)
(89)
Figure 2: F93 Series Air Volume Control for Deep Wells Dimensions, in. (mm)
F93 Series Air Volume Controls for Deep Wells Product/Technical Bulletin
2
To system
Tank Air
Escapes
into Room Tank Air
Escapes
into Room
Check and Snifter Valve
Drain Fitting
FIG:F93_applcn
Submersible Pump
Figure 3: F93 Series Air Volume Control for Deep Well Application
If you do not install a gage, install a standard Setup and adjustments
1/4 in. pipe plug in the opening. Wrap two turns of
On initial start up, the tank is full of air at atmospheric
Teflon thread sealing tape around the male threads of
pressure. This allows the float to drop, holding the air
the plug or gage. Overlap the tape half its width to
valve in the open position. Pressure does not build up
make two layers. If you are using pipe sealant instead
in the tank until sufficient water is pumped into the tank
of Teflon tape, apply a generous amount of sealant to
to raise the float and close the valve.
the male threads.
The volume of air stabilizes after several cycles.
Note: Do not overtighten. 5 lb·ft (6.8 N•m) of torque is
adequate to seal the threads. If the pump short-cycles after several days of
operation, the supply of air in the tank is insufficient.
IMPORTANT: Do not use the gage opening to Open the air inlet valve on the pump so that more air
connect the pressure switch controlling the can enter the system.
operating pump. It must only be used for a pressure
Air volume controls require no oiling or adjustments.
gage because the opening can become plugged.
Checkout procedure
Before leaving the installation, observe at least three
complete operating cycles to be sure all components
are functioning correctly.
F93 Series Air Volume Controls for Deep Wells Product/Technical Bulletin
3
Ordering information
To order, specify the complete product code number.
Table 2: Selection chart for F93 Series Air Volume Controls for Deep Wells
Product Description
code
number
F93A-1C Air Volume Control for Deep Wells, opens on pressure drop, no gage tap, no pressure release valve
F93B-1C Air Volume Control for Deep Wells, opens on pressure drop, 1/4-18 PTF SAE short gage tap, no pressure
release valve
F93H-1C Air Volume Control for Deep Wells, opens on pressure drop, 1/4-18 PTF SAE short gage tap, with
25 PSIG (172 kPa) minimum air pressure release valve. Use this model in applications where water may be
rapidly drawn from the system.
Repair information
Do not make field repairs. Repair parts are not available. If an F93 Series Air Volume Control for Deep Wells
malfunctions, replace the control. Contact your nearest Johnson Controls®/PENN® distributor or sales
representative to purchase a replacement.
Technical specifications
F93 Series Air Volume Control for Deep Wells
Body material 30% glass-filled Noryl thermoplastic
Float material Plastic with brass rod
Maximum tank pressure 100 psig (690 kPa)
Shipping weight Individual: 0.19 kg (0.42 lb)
Tank connector size 1-1/4 in. Male NPT
Compliance United States Federal Safe Drinking Water Act (SDWA) Compliant,
Underwriters Laboratories Classified in Accordance with NSF/ANSI 372 (File MH59894)
The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these
specifications, consult Johnson Controls/PENN application engineering at 1-414-524-5535 or 1-800-275-5676. Johnson Controls shall not be
liable for damages resulting from misapplication or misuse of its products. © 2018 Johnson Controls.
www.penncontrols.com
® Johnson Controls and PENN are registered trademarks of Johnson Controls in the
United States of America and/or other countries. All other trademarks used herein are the property
of their respective owners. © Copyright 2018 by Johnson Controls. All rights reserved.