F93 Series Air Volume Controls for Deep Wells
Product/Technical Bulletin
                                                                                     Part No. 24-7664-3000, Rev. A
                                                                                                 Issued October 2018

The F93 Series Air Volume Controls for Deep Wells
control the amount of air in the residential water
storage tanks of deep well water systems. Deep wells
are more than 25 ft (7.6 m) deep.
F93 Series Controls automatically maintain air volume
in the storage tanks of deep well water systems by
allowing air to escape from the tank and into the
surrounding room when the water level in the tank
drops (increase of air volume).
F93 deep well controls open the air valve on a fall in
tank water level to bleed excess air from the tank at
pressures up to 100 psig (690 kPa).
The F93H has a minimum pressure release valve to                        Figure 1: F93B Air Volume Control
avoid lowering tank pressure below 25 psig (172 kPa).                             for Deep Wells
Use this model on applications where water may be
rapidly drained.

Table 1: Features and benefits
 Features                                                    Benefits
 Sturdy Noryl (high performance thermoplastic) body          Resists mechanical damage and corrosion.
 Brass internal operating parts                              Minimize corrosion.
 Pressure tested plastic float                               Provides long operating life.
 Optional pressure gauge tapping                             Allows mounting of a pressure gauge.
 Certification for Federal Safe Drinking Water Act           Meets the US Federal standards of the Reduction of Lead in
                                                             Drinking Water Act.

                     F93 Series Air Volume Controls for Deep Wells Product/Technical Bulletin

                                                         1
Application                                                          Install the control in the tank as follows:
                                                                     1. If you are using Teflon® thread sealing tape, wrap
    IMPORTANT: Use this F93 Series Air Volume
                                                                        the 1-1/4 in. NPT threads on the control. Overlap
    Control for Deep Wells only as an operating control.
                                                                        the tape half its width to make two layers, and
    Where failure or malfunction of the F93 Series Air
                                                                        continue to where the thread ends at the large end.
    Volume Control could lead to personal injury or
                                                                        If you are using pipe sealant instead of Teflon tape,
    property damage to the controlled equipment or
                                                                        apply a generous amount of sealant to the male
    other property, additional precautions must be
                                                                        threads.
    designed into the control system. Incorporate and
    maintain other devices, such as supervisory or                   2. Using a wrench on the flat sides of the control
    alarm systems or safety or limit controls, intended to              body, screw the control into a tank opening located
    warn of or protect against failure or malfunction of                about 2/3 of the way up.
    the F93 Series Air Volume Control.
                                                                     Note: The tank must have a diameter of at least 9 in.
                                                                     (229 mm) to allow room for the float to operate.
Water storage tanks in residential water systems rely
on a volume of air in the tank to provide system
                                                                      IMPORTANT: Tighten (not overly tight) with the air
pressure, making it important to control the amount of
                                                                      valve and assembly pointed down. Ensure that the
air in the tank:
                                                                      wrench does not slip and damage the air valve
•     Too little air in the tank results in rapid pump cycling        casing assembly.
      - a problem common in shallow well systems (less
      than 25 ft [7.6 m] deep).                                      F93B and F93H models
                                                                     The F93B and F93H models have a 1/4 in. tapped
•     Too much air in the tank results in air entering the
                                                                     opening for a pressure port at the top of the control.
      distribution system - a problem common in deep
      well systems (more than 25 ft [7.6 m] deep).                   When you install a gage into this pressure port, wrap
                                                                     two turns of Teflon thread sealing tape around the male
For information on air volume controls for shallow
                                                                     threads of the gage. Overlap the tape half its width to
wells, refer to the F92 Series Air Volume Controls for
                                                                     make two layers. If you are using pipe sealant instead
Shallow Wells Product/Technical Bulletin
                                                                     of Teflon tape, apply a generous amount of sealant to
(Part No. 24-7664-2993).
                                                                     the male threads.
Installation
    IMPORTANT: Use only Teflon® thread sealing tape
    or pipe sealant that is compatible with plastic. Pipe
    sealant meant for use with metal may corrode the
    plastic body, causing it to crack.
              1-1/4
              (32)

                                                                                                                       FIG:F93_dmnsns
                                                                                   6-11/16
                                                                                    (171)

                                                                                             1-3/8 (35)            2-11/16
                                                                                             Diameter                (68)
                                  1/4
                                  (6)
                                                    1-3/16
                                           13/16
                                                     (30)
                                            (21)

             1-11/16
                                                                                                  3-1/2
               (43)
                                                                                                  (89)

                      Figure 2: F93 Series Air Volume Control for Deep Wells Dimensions, in. (mm)

                          F93 Series Air Volume Controls for Deep Wells Product/Technical Bulletin

                                                                 2
                                                                                                         To system

                                Tank Air
                                Escapes
                                into Room                          Tank Air
                                                                   Escapes
                                                                   into Room

                                                    Check and Snifter Valve

                                                 Drain Fitting

                                                                                                               FIG:F93_applcn
                                                 Submersible Pump

                     Figure 3: F93 Series Air Volume Control for Deep Well Application
If you do not install a gage, install a standard                 Setup and adjustments
1/4 in. pipe plug in the opening. Wrap two turns of
                                                                 On initial start up, the tank is full of air at atmospheric
Teflon thread sealing tape around the male threads of
                                                                 pressure. This allows the float to drop, holding the air
the plug or gage. Overlap the tape half its width to
                                                                 valve in the open position. Pressure does not build up
make two layers. If you are using pipe sealant instead
                                                                 in the tank until sufficient water is pumped into the tank
of Teflon tape, apply a generous amount of sealant to
                                                                 to raise the float and close the valve.
the male threads.
                                                                 The volume of air stabilizes after several cycles.
Note: Do not overtighten. 5 lb·ft (6.8 N•m) of torque is
adequate to seal the threads.                                    If the pump short-cycles after several days of
                                                                 operation, the supply of air in the tank is insufficient.
 IMPORTANT: Do not use the gage opening to                       Open the air inlet valve on the pump so that more air
 connect the pressure switch controlling the                     can enter the system.
 operating pump. It must only be used for a pressure
                                                                 Air volume controls require no oiling or adjustments.
 gage because the opening can become plugged.
                                                                 Checkout procedure
                                                                 Before leaving the installation, observe at least three
                                                                 complete operating cycles to be sure all components
                                                                 are functioning correctly.

                    F93 Series Air Volume Controls for Deep Wells Product/Technical Bulletin

                                                            3
Ordering information
To order, specify the complete product code number.
Table 2: Selection chart for F93 Series Air Volume Controls for Deep Wells
 Product        Description
 code
 number
 F93A-1C        Air Volume Control for Deep Wells, opens on pressure drop, no gage tap, no pressure release valve
 F93B-1C        Air Volume Control for Deep Wells, opens on pressure drop, 1/4-18 PTF SAE short gage tap, no pressure
                release valve
 F93H-1C        Air Volume Control for Deep Wells, opens on pressure drop, 1/4-18 PTF SAE short gage tap, with
                25 PSIG (172 kPa) minimum air pressure release valve. Use this model in applications where water may be
                rapidly drawn from the system.

Repair information
Do not make field repairs. Repair parts are not available. If an F93 Series Air Volume Control for Deep Wells
malfunctions, replace the control. Contact your nearest Johnson Controls®/PENN® distributor or sales
representative to purchase a replacement.
Technical specifications
F93 Series Air Volume Control for Deep Wells
 Body material                          30% glass-filled Noryl thermoplastic
 Float material                         Plastic with brass rod
 Maximum tank pressure                  100 psig (690 kPa)
 Shipping weight                        Individual: 0.19 kg (0.42 lb)
 Tank connector size                    1-1/4 in. Male NPT
 Compliance                             United States Federal Safe Drinking Water Act (SDWA) Compliant,
                                        Underwriters Laboratories Classified in Accordance with NSF/ANSI 372 (File MH59894)
The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these
specifications, consult Johnson Controls/PENN application engineering at 1-414-524-5535 or 1-800-275-5676. Johnson Controls shall not be
liable for damages resulting from misapplication or misuse of its products. © 2018 Johnson Controls.

                                                                                                             www.penncontrols.com

                                           ® Johnson Controls and PENN are registered trademarks of Johnson Controls in the
                              United States of America and/or other countries. All other trademarks used herein are the property
                                          of their respective owners. © Copyright 2018 by Johnson Controls. All rights reserved.