Code No. LIT-1922335
                                                                                                                                                  Issued February 1, 2009

F61 Series
Flow Switch (Standard Flow Rate – SPDT)
Description                                                    Series F61
The F61 Series Flow Switches are
Single-Pole, Double-Throw                                      B
(SPDT) flow switches used on
fluid lines carrying water, ethylene
glycol, or other fluids not classified
as hazardous. They can be wired                                Y
to energize one device and de-
energize another device powered                                R                       f61.eps
from the same source when fluid
flow either exceeds or drops                             Action on Increase
below the set flow rate.                                      of Flow
The F61MG type flow switches           F61 Series Action Diagram
are used for low-energy loads to
operate small relays, solenoid valves, and electronic control circuits.
These flow switches have gold-plated contacts for improved electrical
performance in low voltage, low current circuits.                                                                F61KB-11                                            F61MB-1

Features                                                                                         Applications
•   stainless steel paddle has three segments for use in pipes from 1 in.                        •   use on lines carrying water or ethylene glycol
    to 3 in. (25 mm to 75 mm) diameter                                                           •   not for use with hazardous fluids or in hazardous atmospheres
•   paddle segments can be removed or trimmed as needed
•   F61KB-11 and F61MB-1 include a 6 in. (152 mm) paddle for pipes
    4 in. to 6 in. (102 mm to 152 mm)
•   gold-plated contacts on F61MG-1 reduce intermittent contact
    problems in low-voltage and low-current circuits

Selection Charts
F61 Series Flow Switch (Standard Flow Rate – SPDT)
Code Number Enclosure Bellows             Paddle
F61KB-11C             NEMA 1            Phosphor Bronze Stainless Steel; 3-piece Paddle (3 in., 2 in., and 1 in. Segments) Installed; 6 in. Paddle Supplied Uninstalled
F61LB-1C              NEMA 3R           Phosphor Bronze Stainless Steel; 3-piece Paddle (3 in., 2 in., and 1 in. Segments) Installed
F61MB-1C              NEMA 3R           Phosphor Bronze Stainless Steel; 3-piece Paddle (3 in., 2 in., and 1 in. Segments) Installed; 6 in. Paddle Supplied Uninstalled
F61MB-5C              NEMA 3R           Stainless Steel        Stainless Steel; 3-piece Paddle (3 in., 2 in., and 1 in. Segments) Installed; 6 in. Paddle Supplied Uninstalled
F61MG-1C 1            NEMA 3R           Phosphor Bronze Stainless Steel; 3-piece Paddle (3 in., 2 in., and 1 in. Segments) Installed; 6 in. Paddle Supplied Uninstalled
1. Gold-Plated Contacts

Replacement Kits
Code Number Description
KIT21A-600             Stainless Steel 3-piece Paddle (3 in., 2 in., and 1 in. Segments)
KIT21A-601             Stainless Steel 6 in. Paddle
PLT52A-600R            Stainless Steel 3-piece Paddle (3 in., 2 in., and 1 in. Segments) and 6 in. Paddle
CVR62A-600R            Replacement Cover Assembly for F61MB-1, F61MB-5, and F61MG-1

Technical Specifications
                                                           F61 Series Standard Flow Rate Switch (Part 1 of 2)
Maximum Fluid Pressure                                      160 psig (1103 kPa)
Fluid                          Minimum                      F61KB, F61LB: 32°F (0°C)
Temperature                                                 F61MB, F61MG: -20°F (-29°C)
                               Maximum                      250°F (121°C) for all models
Wiring Connections                                          F61KB, F61LB: Screw Type Terminal
                                                            F61MB, F61MG: Four Color-coded No. 14 AWG Solid Conductor Wire Leads, 7 in. (178 mm) Long
Pipe Connector                                              1 in. 11-1/2 NPT Threads
Conduit Connection                                          F61KB: One 7/8 in. (22 mm) Hole for 1/2 in. Conduit with 1-3/32 in. (28 mm) Knockout Ring for 3/4 in. Conduit
                                                            F61LB, F61MB, F61MG: Female Hub for 1/2 in. Conduit, 1/2-14 NPSM Threads
Paddle                                                      Installed Stainless Steel 3-piece Paddle (3 in., 2 in., and 1 in. Segments);
                                                            Stainless Steel 6 in. Paddle Supplied w/ F61MB and F61KB
Switch                                                      SPDT Snap-acting Pennswitch

The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2009 Johnson Controls, Inc.                  www.johnsoncontrols.com

                                                                                       1 of 2
Flow Switch (Standard Flow Rate – SPDT) (Continued)

Technical Specifications (Continued)
                                                           F61 Series Standard Flow Rate Switch (Part 2 of 2)
Enclosure                      Case                          F61KB: 0.062 in. (1.57 mm) Steel
                                                             F61LB, F61MB, F61MG: 0.062 in. (1.57 mm) Cold Drawn Steel
                               Cover                         F61KB: 0.028 in. (0.7 mm) Steel (NEMA 1)
                                                             F61LB: 0.062 in. (1.57 mm) Cold Drawn Steel, (NEMA 3R)
                                                             F61MB, F61MG: 0.062 in. (1.57 mm); Cold Drawn Steel, Gasketed (NEMA 3R Rain-tight)
Agency                         UL Listed                     All models: E5368, CCN NMFT
Listings                       CSA Certified                 F61KB: LR948, Class 3211 06,Class 4813 02, Class 1222 01
                                                             F61LB: Not CSA Certified
                                                             F61MB, F61MG: LR948, Class 3211 06
Shipping Weight                                              2.8 lb (1.3 kg)

Electrical Ratings for F61KB, F61LB, and F61MB Models                                              Electrical Ratings for F61MG Models
Electrical Ratings     120 VAC 208 VAC 240 VAC 277 VAC                                             Electrical Ratings         120 VAC
Horsepower                     1             1               1               -                     Full Load Amperes                     1
Full Load Amperes              16.0          8.8             8.0             -                     Locked Rotor Amperes                  6
Locked Rotor Amperes           96.0          52.8            48.0            -                     Non-inductive Amperes                 2
Non-inductive Amperes          16.0          16.0            16.0            16.0                  Pilot Duty                            125 VA at 24/277 VAC
Pilot Duty                     125 VA at 24/277 VAC

Typical Flow Rates for Switches with 1 to 3 in. paddles
 GPM (m3/hr) Required to Actuate Switch
 Pipe Size (in.)                              1              1-1/4 1         1-1/2        2        2-1/2 2       3              43             53             63            83
                                                         F61KB, F61LB, and F61MB Models, 1 to 3 in. Paddles
 Minimum             Flow Increase            4.2            5.8             7.5          13.7     18.0          27.5           65.0           125.0          190.0         375.0
 Adjustment          (R to Y Closes)          (0.95)         (1.32)          (1.70)       (3.11)   (4.09)        (6.24)         (14.8)         (28.4)         (43.2)        (85.2)
                     Flow Decrease            2.5            3.7             5.0          9.5      12.5          19.0           50.0           101.0          158.0         320.0
                     (R to B Closes)          (0.57)         (0.84)          (1.14)       (2.16)   (2.84)        (4.32)         (11.4)         (22.9)         (35.9)        (72.7)
 Maximum             Flow Increase            8.8            13.3            19.2         29.0     34.5          53.0           128.0          245.0          375.0         760.0
 Adjustment          (R to Y Closes)          (2.0)          (3.02)          (4.36)       (6.6)    (7.84)        (12.0)         (29.1)         (55.6)         (85.2)        (172.6)
                     Flow Decrease            8.5            12.5            18.0         27.0     32.0          50.0           122.0          235            360.0         730.0
                     (R to B Closes)          (1.93)         (2.84)          (4.09)       (6.13)   (7.27)        (11.4)         (27.7)         (53.4)         (81.8)        (165.8)
                                                                           F61MG Models, 1 to 3 in. Paddles
 Minimum             Flow Increase            3.8            5.3             6.9          12.7     16.7          24.3           61.0           118.0          183.0         362.0
 Adjustment          (R to Y Closes)          (0.9)          (1.2)           (1.6)        (2.88)   (3.79)        (5.52)         (13.8          (26.80)        (41.56)       (82.22)
                     Flow Decrease            2.5            3.7             5.0          9.5      12.5          19.0           50.0           101.0          158.0         320.0
                     (R to B Closes)          (0.6)          (0.8)           (1.1)        (2.2)    (2.84)        (4.32)         (11.4)         (22.94)        (35.88)       (72.68)
 Maximum             Flow Increase            8.7            13.1            18.8         28.9     33.7          52.1           126.0          243.0          372.0         753.0
 Adjustment          (R to Y Closes)          (2.0)          (2.98)          (4.27)       (6.56)   (7.65)        (11.8)         (28.62)        (55.19)        (84.49)       (171.0)
                     Flow Decrease            8.5            12.5            18.0         27.0     32.0          50.0           122.0          235.0          360.0         730.0
                     (R to B Closes)          (1.9)          (2.84)          (4.09)       (6.13)   (7.27)        (11.4)         (27.71)        (55.37)        (81.76)       (165.8)
1. Flow rates for two inch paddle trimmed to fit pipe.
2. Flow rates for three inch paddle trimmed to fit pipe.
3. Flow rates are calculated for factory-installed set of one, two, and three inch paddles.

Typical Flow Rates for Switches with 6 in. paddles (Part 1 of 2)                                   Typical Flow Rates for Switches with 6 in. paddles (Part 2 of 2)
GPM (m3/hr) Required to Actuate Switch                                                             GPM (m3/hr) Required to Actuate Switch
Pipe Size (in.)                                4         5             6              8            Pipe Size (in.)                              4         5             6          8
           F61KB, F61LB, and F61MB Models, 6 in. Paddles                                                                  F61MaaG Models, 6 in. Paddles
Minimum              Flow Increase             37.0      57.0          74.0           205.0        Minimum             Flow Increase            35.0      53.0          69.0       197.0
Adjustment           (R to Y Closes)           (8.40)    (12.9)        (16.81)        (46.56)      Adjustment          (R to Y Closes)          (7.95)    (12.0)        (15.7)     (44.74)
                     Flow Decrease             27.0      41.0          54.0           170.0                            Flow Decrease            27.0      41.0          54.0       170.0
                     (R to B Closes)           (6.13)    (9.31)        (12.26)        (38.61)                          (R to B Closes)          (6.13)    (9.31)        (12.3)     (38.61)
Maximum              Flow Increase             81.0      118.0         144.0          415.0        Maximum             Flow Increase            80.0      116.0         142.0      412.0
Adjustment           (R to Y Closes)           (13.4)    (26.80)       (32.70)        (94.26)      Adjustment          (R to Y Closes)          (18.2)    (26.34)       (32.25)    (93.58)
                     Flow Decrease             76.0      111.0         135.0          400.0                            Flow Decrease            76.0      111.0         135.0      400.0
                     (R to B Closes)           (17.3)    (25.21)       (30.66)        (90.85)                          (R to B Closes)          (17.3)    (25.21)       (30.66)    (90.85)

Note:     Flow rates for these sizes are calculated. Where paddle size is larger than pipe size, flow rates are for 6 in. paddle trimmed to fit pipe.

The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2009 Johnson Controls, Inc.                  www.johnsoncontrols.com

                                                                                          2 of 2