SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

Encapsulated pressure switch, P100 Series

Вид документаТехнічний паспорт
ВиробникJCI
МоделіP100AP-201C, P100AP-2C, P100AP-3C, P100AP-4C, P100AC-1C, P100AC-2C, P100CP-1C, P100CP-2C
Група обладнанняpressure
Мова документаанглійська
Розмір файлу0.1 МБ

Про документ

P100 Series switches are encapsulated, nonadjustable, SPST, direct mount switches for use with noncorrosive refrigerants. They are available with automatic reset in both open low and open high configurations and manual reset with open high action.

Ключові дані

Electrical ratingAC FLA 5.8 A at 120 VAC / 2.9 A at 240 VAC; AC LRA 34.8 A at 120 VAC / 15.0 A at 240 VAC
Pilot duty375 VA at 120/240/277 VAC; 2 amps at 28 VAC/VDC
Switch actionSPST, nonadjustable, encapsulated; automatic reset (open low and open high) and manual reset with open high action
Process connection1/4 in. female flare fitting with built-in Schrader type depressor
Setting range low side5 … 170 psig (34 … 1172 kPa)
Setting range high side275 … 475 psig (1896 … 3275 kPa)
Leads48 in. leads

Застосування

  • Low limit, high limit, and fan cycling control in commercial refrigeration
  • Ice machines
  • Food service equipment

Особливості

  • Compact size and light weight allow for direct mounting
  • Use with all non-corrosive refrigerants
  • 1/4 in. female flare fitting with built-in Schrader type depressor is standard
  • Encapsulated switch, dust tight
  • Trip-free manual reset (manual reset models): contacts cannot be overridden by continued depression of the reset button
  • Electrical connections are made to 48 in. leads

Технічні дані

Parameter Value
Switch configuration SPST, encapsulated, nonadjustable
Reset options Automatic reset (open low / open high), manual reset open high
AC Full Load Amps (FLA), 120 VAC 5.8
AC Full Load Amps (FLA), 240 VAC 2.9
AC Locked Rotor Amps (LRA), 120 VAC 34.8
AC Locked Rotor Amps (LRA), 240 VAC 15.0
Pilot Duty 375 VA at 120/240/277 VAC; 2 amps at 28 VAC/VDC
Process connection 1/4 in. female flare fitting with built-in Schrader type depressor
Leads 48 in. leads
Media Noncorrosive refrigerants

Варіанти замовлення

Code Number Switch Action / Application Opens – psig (kPa) Closes – psig (kPa) Replaces Gemline® Replaces Ranco® Replaces Robertshaw® Replaces Saginomiya®
P100AP-201C Open on pressure drop, low cutout 10 (69) 32 (221) MPL-7011 3100-050
P100AP-2C Open on pressure drop, fan cycling 35 (241) 60 (414) MPF-7004 3100-004
P100AP-3C Open on pressure drop, fan cycling 150 (1034) 225 (1551) MPF-7008 ABC-AA01
P100AP-4C Open on pressure drop, fan cycling 170 (1172) 250 (1724)
P100AC-1C¹ Open on pressure rise, automatic reset, low cutout 5 (34) 20 (138) MPL-7001
P100AC-2C¹ Open on pressure rise, automatic reset, low cutout 15 (103) 30 (207) MPL-7002
P100CP-1C High cutout 400 (2758) 300 (2068) PC151 MPH-7107 3100-151
P100CP-2C High cutout 425 (2930) 325 (2241) PC100 MPH-7108 3100-100
P100CC-9C¹ Open on pressure rise, manual reset 275 (1896) 175 (1207) 3100-112
P100DA-1C¹ Open on pressure rise, manual reset, lockout 410 (2827) PC103 3100-103
P100DA-2C High limit 475 (3275) 3100-106
P100DA-35C² 350 (2413)
P100DC-3C² 375 (2586)
  1. Includes conduit clamp (shown above)
  2. In conduit box

Текст документа

                                                                                                                                                  Code No. LIT-1927275
                                                                                                                                                  Issued March 1, 2006

P100 Series
Encapsulated Pressure Switches
Description                                                     Features
P100 Series switches are encapsulated,                          •    compact size and light weight allow for
nonadjustable, SPST, direct mount switches                           direct mounting
for use with noncorrosive refrigerants. The                     •    use with all non-corrosive refrigerants
switches are available with automatic reset in                  •    1/4 in. female flare fitting with built-in
both open low and open high configurations                           Schrader type depressor is standard
and manual reset with open high action.                         •    encapsulated switch, dust tight
                                                                •    trip-free manual reset (manual reset
Technical Specifications                                             models)...contacts cannot be overridden
Electrical Ratings                     120        240                by continued depression of the reset
                                       VAC        VAC                button
AC Full Load Amps (FLA)                   5.8        2.9        •    electrical connections are made to 48 in.
                                                                     leads
AC Locked Rotor Amps (LRA)                34.8       15.0
Pilot Duty – 375 VA at 120/240/277 VAC;                           Applications
2 amps at 28 VAC/VDC
                                                                •    low limit, high limit, and fan cycling control                                      P74EA-8
                                                                     in commercial refrigeration
                                                                •    ice machines
                                                                •    food service equipment

Selection Chart
Code                  Switch            Application             Setting – psig (kPa)                    Replaces:
Number                Action                                    Opens                Closes             Gemline®             Ranco®                Robertshaw® Saginomiya
P100AP-201C                                                     10 (69)              32 (221)                    –           MPL-7011              3100-050                       –
                                        Low Cutout
P100AP-2C                                                       35 (241)             60 (414)                    –           MPF-7004              3100-004                       –
P100AP-3C             Open On                                   150 (1034)           225 (1551)                  –           MPF-7008                       –           ABC-AA01
                      Pressure          Fan Cycling
P100AP-4C             Drop                                      170 (1172)           250 (1724)                  –                     –                    –                     –
P100AC-1C 1                                                     5 (34)               20 (138)                    –           MPL-7001                       –                     –
                                        Low Cutout
P100AC-2C 1                                                     15 (103)             30 (207)                    –           MPL-7002                       –                     –
P100CP-1C                                                       400 (2758)           300 (2068)         PC151                MPH-7107              3100-151                       –
P100CP-2C                               High Cutout             425 (2930)           325 (2241)         PC100                MPH-7108              3100-100                       –
P100CC-9C 1                                                     275 (1896)           175 (1207)                  –                     –           3100-112                       –
                      Open On
P100DA-1C             Pressure                                  410 (2827)           Lockout            PC103                          –           3100-103                       –
                      Rise                                                           Manual Reset
P100DA-2C                                                       475 (3275)                                       –                     –           3100-106                       –
                                        High Limit
P100DA-35C                                                      350 (2413)                                       –                     –                    –                     –
               2
P100DC-3C                                                       375 (2586)                                       –                     –                    –                     –
1. Includes conduit clamp (shown above)
2. In conduit box




The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2006 Johnson Controls, Inc.                  www.johnsoncontrols.com

                                                                                       1 of 1


Документ виробника, опублікований як довідковий матеріал на обладнання, яке ми постачаємо. Правовласник може попросити прибрати його — приберемо.