MS-FEC1611-0 — Metasys Field Equipment Controller FEC/FAC

Вид документаТехнічний паспорт
ВиробникJCI
МоделіMS-FEC1611-0, MS-FEC1621-0, MS-FEC2611-0, MS-FEC2621-0, MS-FAC2611-0, MS-FAC2612-1, MS-FAC2612-2
Група обладнанняautomation
Мова документаанглійська
Розмір файлу0.1 МБ

Про документ

The Metasys® Field Equipment Controllers (FEC) are a family of BACnet® compatible field controllers for HVAC control applications, built on the ASHRAE building automation standard. The range includes the 10-point FEC1600 and 17-point FEC2600 models plus FAC Series advanced application controllers with integral real-time clock for time-based tasks (schedules, calendars, alarms, trends), all integrated with the Metasys® building management system. Optional LCD display available on some models.

Ключові дані

Supply voltage (FEC)24 VAC (nominal, 20 VAC minimum/30 VAC maximum), 50/60 Hz, SELV (Europe)
Supply voltage (MS-FAC2612-2)100 to 250 VAC, 50/60 Hz
Communications busBACnet® MS/TP, RS-485; 3-wire FC Bus, 4-wire SA Bus with 15 VDC bus supply
Operating conditions0 to 50°C; 10 to 90% RH noncondensing
Storage temperature-40 to 80°C; 5 to 95% RH noncondensing
Analog resolutionAnalog input: 16-bit; Analog output: 16-bit and ±200 mV in 0–10 VDC applications
Protection classIP20 (IEC529)
BACnet listingBTL 135-2004 Listed BACnet Application Specific Controller (B-ASC) / Advanced Application Controller (B-AAC)

Застосування

  • Wide range of HVAC control applications
  • VAV application specific control (via application specific controllers in the family)
  • Time-based monitoring and control of schedules, calendars, alarms and trends (FAC models)
  • Integration with Metasys® building management system, network sensors and other sensor/actuator devices

Особливості

  • Supports peer-to-peer communications
  • Continuous tuning adaptive control reduces manual intervention
  • Advanced diagnostics for failure detection, resolution and prevention
  • Standard packaging and terminations simplify installation
  • Tested by BACnet Testing Labs (BTL); certified as BACnet Application Specific Controllers
  • FAC models feature integral real-time clock with on-board time schedules, calendars, trends and alarms; BTL certified as BACnet Advanced Application Controllers (B-AAC)
  • Optional integral LCD display on selected models

Технічні дані

Parameter Value
Supply voltage (FEC1611/FEC2611) 24 VAC (nominal, 20 VAC minimum/30 VAC maximum), 50/60 Hz, Safety Extra-Low Voltage (SELV) (Europe)
Supply voltage (FEC1621/FEC2621) 24 VAC (nominal, 20 VAC minimum/30 VAC maximum), 50/60 Hz, Safety Extra-Low Voltage (SELV) (Europe)
Power consumption (FEC16, no display) 14 VA maximum
Power consumption (with integral display) 20 VA maximum
Supply voltage (FAC2611-0, FAC2612-1) 24 VAC (nominal, 20 VAC minimum/30 VAC maximum), 50/60 Hz, SELV (Europe)
Supply voltage (MS-FAC2612-2) 100 to 250 VAC, 50/60 Hz
Power consumption (FAC) 25 VA maximum
Peripheral device power note BOs/COs can consume up to 12 VA each; possible additional total 84 VA maximum
Operating conditions 0 to 50°C; 10 to 90% RH noncondensing
Storage conditions -40 to 80°C; 5 to 95% RH noncondensing
Controller addressing DIP switch set; valid field controller device addresses 4–127 (addresses 0–3 and 128–255 reserved)
Communications bus BACnet® MS/TP, RS-485: 3-wire FC Bus (supervisory controller ↔ field controllers); 4-wire SA Bus (field controller, network sensors, other devices) with lead sourcing 15 VDC supply power
Processor H8SX/166xR Renesas® microcontroller
Memory (FEC) 1 MB flash memory and 512 KB RAM
Memory (FAC) 4 MB Flash Memory and 1 MB RAM
Point counts FEC16 2 UI, 1 BI, 3 BO, 4 CO
Point counts FEC26/FAC2611 6 UI, 2 BI, 3 BO, 2 AO, 4 CO
Point counts FAC2612 5 UI, 4 BI, 4 CO, 5 RO
Universal inputs 0–10 VDC voltage mode; 4–20 mA current mode; resistive mode 0–2k ohm, RTD (1k NI [Johnson Controls], 1k PT, A99B SI), NTC (10k type L, 2.252k type 2); binary dry contact maintained mode
Binary inputs Dry contact maintained mode; pulse counter/accumulator mode (high speed), 100 Hz
Analog outputs 0–10 VDC voltage mode or 4–20 mA current mode
Configurable outputs 0–10 VDC voltage mode or 24 VAC triac binary output mode
Relay outputs (FAC2612) 240 VAC maximum voltage; 1/3 hp 125 VAC, 1/2 hp 250 VAC; 400 VA Pilot Duty at 240 VAC; 200 VA Pilot Duty at 120 VAC; 3 A Noninductive 24-240 VAC
Analog input/output resolution and accuracy Analog input: 16-bit resolution; analog output: 16-bit resolution and ±200 mV in 0–10 VDC applications
Terminations Input/output: fixed screw terminal blocks (pluggable on FAC2612); FC Bus, SA Bus and power supply: 3-wire and 4-wire pluggable screw terminal blocks; FC Bus and SA Bus: RJ-12 6-pin modular jacks
Mounting Horizontal on single 35 mm DIN rail (preferred) or screw mount on flat surface with three integral mounting clips
Housing Enclosure material: ABS and polycarbonate UL94 5VB; self-extinguishing, plenum-rated. Protection class: IP20 (IEC529)
Dimensions FEC16 models 150 x 164 x 53 mm including terminals and mounting clips
Dimensions FEC26/FAC2611 models 150 x 190 x 53 mm including terminals and mounting clips
Dimensions FAC2612-x models 150 x 164 x 53 mm including terminals and mounting clips
Weight FEC16 models 0.4 kg
Weight FEC26/FAC models 0.5 kg

Варіанти замовлення

Ordering code Description
MS-FEC1611-0 10-Point Field Equipment Controller with 2 UI, 1 BI, 3 BO and 4 CO; 24 VAC; SA Bus
MS-FEC1621-0 10-Point Field Equipment Controller with 2 UI, 1 BI, 3 BO and 4 CO; 24 VAC; SA Bus; Integral display
MS-FEC2611-0 17-Point Field Equipment Controller with 6 UI, 2 BI, 3 BO, 2 AO and 4 CO; 24 VAC; SA Bus
MS-FEC2621-0 Field Equipment Controller Cover with 6 UI, 2 BI, 3 BO, 2 AO and 4 CO; 24 VAC; SA Bus; Integral display
MS-FAC2611-0 17-Point Advanced Application Field Equipment Controller with 6 UI, 2 BI, 2 AO, 3 BO and 4 CO; 24 VAC; SA Bus
MS-FAC2612-1 18-Point Advanced Application Field Equipment Controller with 5 UI, 4 BI, 4 CO and 5 RO; 24 VAC; SA Bus; Pluggable Terminals
MS-FAC2612-2 18-Point Advanced Application Field Equipment Controller with 5 UI, 4 BI, 4 CO and 5 RO; 120-240 VAC; SA Bus; Pluggable Terminals

Accessories:

Ordering code Description
MS-DIS1710-0 Local Controller Display for FEC1610 and FEC2610 Models
MS-BTCVT-1 BlueTooth wireless commissioning adaptor
MS-BTCVTCBL-700 Cable replacement set for the MS-BTCVT-1, includes retractable 5M cable
AP-TBK4SA-0 Replacement MS/TP SA Bus Terminal, 4-Position Connector, Brown, Bulk Pack
AP-TBK4FC-0 Replacement MS/TP FC Bus Terminal, 4-Position Connector, Blue, Bulk Pack
AP-TBK3PW-0 Replacement Power Terminal, 3-Position Connector, Grey, Bulk Pack
MS-TBKLV03-0 FAC2612, 3 Position Line Voltage Terminal Block. Includes 3 pieces (Grey)
MS-TBKRO02-0 FAC2612, 2 Position Relay Output Terminal Block. Includes 9 pieces, 3 of each position (Red)
MS-TBKRO03-0 FAC2612, 3 Position Relay Output Terminal Block. Includes 6 pieces, 3 of each position (Red)
MS-TBKCO04-0 FAC2612, 4 Position Configurable Output Terminal Block. Includes 6 pieces, 3 of each position (Black)
MS-TBKUI04-0 FAC2612, 4 Position Universal Input Terminal Block. Includes 9 pieces, 3 of each position (White)
MS-TBKUI05-0 FAC2612, 5 Position Universal Input Terminal Block. Includes 3 pieces (White)
MS-ZFR1810-0 Wireless Field Bus Coordinator, 10 mW Transmission Power. Functions with NAE35xx, NAE45xx, NAE55xx, and NCE25xx models
MS-ZFR1811-0 Wireless Field Bus Router, 10 mW Transmission Power. Functions with Metasys BACnet FECs, VMA1600s, and WRZ-TTx Series Wireless Mesh Room Temperature Sensors
MS-ZFRCBL-0 Wire Harness for use with ZFR1811 Router. Allows ZFR1811 Router to function with FEC1621; and with FEC1611, VMA1610, or VMA1620 controllers in conjunction with NS Series Sensors, Wireless Commissioning Converter, or DIS1710 Local Controller Display

Допуски та стандарти

  • CE Mark — EMC Directive 2004/108/EC, in accordance with EN 61000-6-3 (2007) Generic Emission Standard for Residential and Light Industry and EN 61000-6-2 (2005) Generic Immunity Standard for Heavy Industrial Environment
  • For FEC26 models, conducted RF immunity within EN 61000-6-2 meets performance criteria B
  • BACnet Testing Laboratories™ (BTL) 135-2004 Listed BACnet Application Specific Controller (B-ASC) — FEC models
  • BACnet Testing Laboratories™ (BTL) 135-2004 Listed BACnet Advanced Application Controller (B-AAC) — FAC models

Позиції каталогу з цим документом

Текст документа

                                                                                                                         bas controllers
                                                                                                                           Field Controllers

MSEA Controllers
FEC/FAC
Field Equipment Controller

The Metasys® Field Equipment Controllers (FEC) are a complete family
of BACnet® compatible field controllers and accessories designed with
the flexibility to meet a wide range of your HVAC control applications.
Built on the ASHRAE standard for building automation system control
and communication, these controllers support Johnson Controls
commitment to open communication standards and greater control
options for you.
The FEC family includes the 10-point FEC1600 and the 17-point FEC2600,
as well as I/O expandability and VAV application specific controllers, all
seamlessly integrated with the Metasys® building management system.
FEC controllers are available with optional LCD display.
FAC Series controllers feature an integral real-time clock and support
time-based tasks, which enables these field controllers to monitor
and control schedules, calendars, alarms and trends.

Features
zz Supports peer-to-peer communications
zz Continuous tuning adaptive control provides more efficient control
   and reduces level of manual intervention
zz Advanced diagnostics for failure detection, resolution and prevention
zz Standard packaging and terminations simplify installation
zz Field Equipment Controllers have been tested by the BACnet Testing
   Labs (BTL) and are certified as BACnet application specific controllers
zz FAC models feature a integral real time clock with on-board time
   schedules, calendars, trends and alarms and are BTL certified
   as BACnet Advanced Application Controllers (B-AAC)

Point Type Counts per Model
Point Types                    Signals Accepted                                                                           FEC16   FEC/FAC2611   FAC2612
                               Analog input, voltage mode, 0–10 VDC
                               Analog input, current mode, 4–20 mA1
Universal Input (UI)           Analog input, resistive mode, 0–2k ohm, RTD (1k NI [Johnson Controls], 1k PT, A99B SI),      2          6              5
                               NTC (10k type L, 2.252k type 2)
                               Binary input, dry contact maintained mode
                               Dry contact maintained mode
Binary Input (BI)                                                                                                           1          2              4
                               Pulse counter/accumulator mode (high speed), 100 Hz
                               Analog output, voltage mode, 0–10 VDC
Analog Output (AO)                                                                                                          0          2              0
                               Analog output, current mode, 4–20 mA
Binary Output (BO)             24 VAC triac                                                                                 3          3              0
                         Analog output, voltage mode, 0–10 VDC
Configurable Output (CO)                                                                                                    4          4              4
                         Binary output mode, 24 VAC triac
                               240 VAC maximum voltage
                               1/3 hp 125 VAC, 1/2 hp 250 VAC                                                                                        5
Relay Outputs (RO)             400 VA Pilot Duty at 240 VAC                                                                 0          0        (2 x SPDT)
                               200 VA Pilot Duty at 120 VAC                                                                                     (3 x SPST)
                               3 A Noninductive 24-240 VAC
Note:
Analog input, current mode is set by hardware for the FEC/FAC26 and as software for the FEC16.



The European Products Catalogue 2012
For further information and additional models see Product Bulletin                                                                              133
 bas controllers
 Field Controllers

FEC/FAC
Field Equipment Controller

Ordering Codes     Description
MS-FEC1611-0       10-Point Field Equipment Controller with 2 UI, 1 BI, 3 BO and 4 CO; 24 VAC; SA Bus
MS-FEC1621-0       10-Point Field Equipment Controller with 2 UI, 1 BI, 3 BO and 4 CO; 24 VAC; SA Bus; Integral display
MS-FEC2611-0       17-Point Field Equipment Controller with 6 UI, 2 BI, 3 BO, 2 AO and 4 CO; 24 VAC; SA Bus
MS-FEC2621-0       Field Equipment Controller Cover with 6 UI, 2 BI, 3 BO, 2 AO and 4 CO; 24 VAC; SA Bus; Integral display
MS-FAC2611-0       17-Point Advanced Application Field Equipment Controller with 6 UI, 2 BI, 2 AO, 3 BO and 4 CO; 24 VAC; SA Bus
MS-FAC2612-1       18-Point Advanced Application Field Equipment Controller with 5 UI, 4 BI, 4 CO and 5 RO; 24 VAC; SA Bus; Pluggable Terminals
MS-FAC2612-2       18-Point Advanced Application Field Equipment Controller with 5 UI, 4 BI, 4 CO and 5 RO; 120-240 VAC; SA Bus; Pluggable Terminals


Accessories
Ordering Codes     Description
MS-DIS1710-0       Local Controller Display for FEC1610 and FEC2610 Models
MS-BTCVT-1         BlueTooth wireless commissioning adaptor
MS-BTCVTCBL-700    Cable replacement Set for the MS-BTCVT-1 includes retractable 5M cable.
AP-TBK4SA-0        Replacement MS/TP SA Bus Terminal, 4-Position Connector, Brown, Bulk Pack
AP-TBK4FC-0        Replacement MS/TP FC Bus Terminal, 4-Position Connector, Blue, Bulk Pack
AP-TBK3PW-0        Replacement Power Terminal, 3-Position Connector, Grey, Bulk Pack
MS-TBKLV03-0       FAC2612, 3 Position Line Voltage Terminal Block. Includes 3 pieces (Grey)
MS-TBKRO02-0       FAC2612, 2 Position Relay Output Terminal Block. Includes 9 pieces, 3 of each position (Red)
MS-TBKRO03-0       FAC2612, 3 Position Relay Output Terminal Block. Includes 6 pieces, 3 of each position (Red)
MS-TBKCO04-0       FAC2612, 4 Position Configurable Output Terminal Block. Includes 6 pieces, 3 of each position (Black)
MS-TBKUI04-0       FAC2612, 4 Position Universal Input Terminal Block. Includes 9 pieces, 3 of each position (White)
MS-TBKUI05-0       FAC2612, 5 Position Universal Input Terminal Block. Includes 3 pieces (White)
MS-ZFR1810-0       Wireless Field Bus Coordinator, 10 mW Transmission Power. Functions with NAE35xx, NAE45xx, NAE55xx, and NCE25xx models.
                   Wireless Field Bus Router, 10 mW Transmission Power. Functions with Metasys BACnet FECs, VMA1600s, and WRZ-TTx Series Wireless
MS-ZFR1811-0
                   Mesh Room Temperature Sensors.
                   Wire Harness for use with ZFR1811 Router. Allows ZFR1811 Router to function with FEC1621; and with FEC1611, VMA1610, or VMA1620
MS-ZFRCBL-0
                   controllers in conjunction with NS Series Sensors. Wireless Commissioning Converter, or DIS1710 Local Controller Display.




                                                                                    The European Products Catalogue 2012
  134                                                                                  For further information and additional models see Product Bulletin
                                                                                                                      bas controllers
                                                                                                                        Field Controllers

FEC/FAC
Field Equipment Controller

FEC - Technical Specifications
 Supply Voltage                     24 VAC (nominal, 20 VAC minimum/30 VAC maximum), 50/60 Hz, Safety Extra-Low Voltage (SELV) (Europe)
 Power Consumption                  14 VA maximum for FEC1611 and FEC2611 (no integral display)
                                    20 VA maximum for FEC1621 and FEC2621 (with integral display)
                                    Note: VA ratings do not include any power supplied to the peripheral devices connected to Binary Outputs (BOs)
                                    or Configurable Outputs (COs), which can consume up to 12 VA for each BO or CO, for a possible total consumption
                                    of an additional 84 VA (maximum).
 Ambient Conditions
                        Operating 0 to 50°C; 10 to 90% RH noncondensing
             Storage Temperature -40 to 80°C; 5 to 95% RH noncondensing
 Controller Addressing              DIP switch set; valid field controller device addresses 4–127
                                    (Device addresses 0–3 and 128–255 are reserved and not valid field controller addresses.)
 Communications Bus                 BACnet® MS/TP, RS-485:
                                    3-wire FC Bus between the supervisory controller and field controllers
                                    4-wire SA Bus between field controller, network sensors, and other sensor/actuator devices,
                                    includes a lead to source 15 VDC supply power (from field controller) to bus devices.
 Processor                          H8SX/166xR Renesas® microcontroller
 Memory                             1 MB flash memory and 512 KB Random Access Memory (RAM)
 Input and Output Capabilities
                    FEC16 Models 2 - Universal inputs: Defined as 0–10 VDC, 4–20 mA, 0–600k ohm or binary dry contact
                                    1 - Binary inputs: Defined as dry contact maintained or pulse counter/accumulator mode
                                    3 - Binary outputs: Defined as 24 VAC triac (selectable internal or external source power)
                                    4 - Configurable outputs: Defined as 0–10 VDC or 24 VAC triac BO
                    FEC26 Models 6 - Universal inputs: Defined as 0–10 VDC, 4–20 mA, 0–600k ohm or binary dry contact
                                    2 - Binary inputs: Defined as dry contact maintained or pulse counter/accumulator mode
                                    3 - Binary outputs: Defined as 24 VAC triac (selectable internal or external source power)
                                    4 - Configurable outputs: Defined as 0–10 VDC or 24 VAC triac BO
                                    2 - Analog outputs: Defined as 0–10 VDC or 4–20 mA
 Analog Input/Analog Output         Analog input: 16-bit resolution
 Resolution and Accuracy            Analog output: 16-bit resolution and ±200 mV in 0–10 VDC applications
 Terminations                       Input/output: Fixed screw terminal blocks
                                    FC Bus, SA Bus and power supply: 3-wire and 4-wire pluggable screw terminal blocks
                                    FC Bus and SA Bus: RJ-12 6-pin modular jacks
 Mounting                           Horizontal on single 35 mm DIN rail mount (preferred) or screw mount on flat surface with three integral
                                    mounting clips on controller
 Housing                            Enclosure material: ABS and polycarbonate UL94 5VB; Self-extinguishing, plenum-rated protection class: IP20 (IEC529)
 Dimensions (H x W x D)
                    FEC16 Models 150 x 164 x 53 mm including terminals and mounting clips
                    FEC26 Models 150 x 190 x 53 mm including terminals and mounting clips
                                    Note: Mounting space for FEC16 and FEC26 models requires an additional 50 mm space on top, bottom, and front face
                                    of controller for easy cover removal, ventilation and wire terminations.
 Weight
                    FEC16 Models 0.4 kg
                    FEC26 Models 0.5 kg
 Compliance
                           Europe CE Mark, EMC Directive 2004/108/EC, in accordance with EN 61000-6-3 (2007) Generic Emission Standard for Residential
                                    and Light Industry and EN 61000-6-2 (2005) Generic Immunity Standard for Heavy Industrial Environment
                                    Note: For FEC26 models, conducted RF immunity within EN 61000-6-2 meets performance criteria B.
             BACnet International BACnet Testing Laboratories (BTL) 135-2004 Listed BACnet Application Specific Controller (B-ASC)


The European Products Catalogue 2012
For further information and additional models see Product Bulletin                                                                                135
 bas controllers
 Field Controllers

FEC/FAC
Field Equipment Controller

FAC - Technical Specifications
Supply Voltage
    FAC2611-0 and FAC2612-1 24 VAC (nominal, 20 VAC minimum/30 VAC maximum), 50/60 Hz, Safety Extra-Low Voltage (SELV) (Europe)
                MS-FAC2612-2 100 to 250 VAC, 50/60 Hz
Power Consumption                25 VA maximum
                                 Note: VA ratings do not include any power supplied to the peripheral devices connected to Binary Outputs (BOs) or Configurable
                                 Outputs (COs), which can consume up to 12 VA for each BO or CO; for a possible total consumption of an additional 84 VA (maximum).
Ambient Conditions
                     Operating 0 to 50°C; 10 to 90% RH noncondensing
                       Storage -40 to 80°C; 5 to 95% RH noncondensing
Controller Addressing            DIP switch set; valid field controller device addresses 4–127
                                 (Device addresses 0–3 and 128–255 are reserved and not valid field controller addresses)
Communications Bus               BACnet® MS/TP, RS-485:
                                 3-wire FC Bus between the supervisory controller and field controllers.
                                 4-wire SA Bus between field controller, network sensors, and other sensor/actuator devices,
                                 includes a lead to source 15 VDC supply power (from field controller) to bus devices.
Processor                     H8SX/166xR Renesas® microcontroller
Memory                        4 MB Flash Memory and 1 MB Random Access Memory (RAM)
Input and Output Capabilities
                    FAC2611-0 6 - Universal Inputs: Defined as 0–10 VDC, 4–20 mA, 0–600k ohm, or Binary Dry Contact
                                 2 - Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode
                                 2 - Analog Outputs: Defined as 0–10 VDC or 4–20 mA
                                 3 - Binary Outputs: Defined as 24 VAC Triac (selectable internal or external source power)
                                 4 - Configurable Outputs: Defined as 0–10 VDC or 24 VAC Triac BO
     FAC2612-1 and FAC2612-2 5 - Universal Inputs: Defined as 0–10 VDC, 4–20 mA, 0–600k ohm, or Binary Dry Contact
                                 4 - Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode
                                 4 - Configurable Outputs: Defined as 0–10 VDC or 24 VAC Triac BO
                                 2 - Relay Outputs: (Single-Pole, Double-Throw) Rated as:
                                 240 VAC maximum voltage
                                 1/3 hp 125 VAC, 1/2 hp 250 VAC
                                 400 VA Pilot Duty at 240 VAC
                                 200 VA Pilot Duty at 120 VAC
                                 3 A Noninductive 24-240 VAC
                                 3 - Relay Outputs: (Single-Pole, Single-Throw) Rated as:
                                 240 VAC maximum voltage
                                 1/3 hp 125 VAC, 1/2 hp 250 VAC
                                 400 VA Pilot Duty at 240 VAC
                                 200 VA Pilot Duty at 120 VAC
                                 3 A Noninductive 24-240 VAC
Analog Input/Analog Output Analog Input: 16-bit resolution
Resolution and Accuracy    Analog Output: 16-bit resolution and ±200 mV in 0–10 VDC applications
Terminations               Input/Output: Fixed Screw Terminal Blocks (FAC2611) Pluggable Terminal Blocks (FAC2612)
                                 FC Bus, SA Bus, and Supply Power: 3-Wire and 4-Wire Pluggable Screw Terminal Blocks
                                 FC Bus and SA Bus: RJ-12 6-Pin Modular Jacks
Mounting                         Horizontal on single 35 mm DIN rail mount (preferred), or screw mount on flat surface with three integral mounting clips on controller
Housing                          Enclosure material: ABS and polycarbonate UL94 5VB; Self-extinguishing, Plenum Rated. Protection Class: IP20 (IEC529)
Dimensions (H x W x D)
                    FAC2611-0 150 x 190 x 53 mm including terminals and mounting clips
                    FAC2612-x 150 x 164 x 53 mm including terminals and mounting clips
                                 Note: Mounting space for FAC26 models requires an additional 50 mm space on top, bottom, and front face of controller for
                                 easy cover removal, ventilation, and wire terminations.
Weight                           0.5 kg
Compliance
                        Europe CE Mark – Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other
                                 relevant provisions of the EMC Directive 2004/108/EC.
          BACnet International BACnet Testing Laboratories™ (BTL) 135-2004 Listed BACnet Advanced Application Controller (B-AAC)


                                                                                           The European Products Catalogue 2012