Текст документа

Code No. LIT-1900401
                                                                                                                                                  Issued November 13, 2015

                         A419 Electronic Thermostat for Temporary Installations
                         (Drop Cord Electrical Connection)

Description
Sturdy compact electronic thermostat designed especially for
temporary installations.
Refer to the A419 Series Electronic Temperature Controls with Display
and NEMA 1 or NEMA 4X Watertight Enclosures Product Bulletin
(LIT-125188) for important product application information.

Features
•   6 ft (1.8 m) extension cord with plug
•   NEMA 1 enclosure
•   easy-to-read LCD display
•   easily configured for heating or cooling applications
•   6-1/2 ft (2.0 m) sensor leads
•   surface or DIN rail mounting
•   lockable front panel touchpad
•   120 VAC line voltage

Applications
•   on/off control of portable space heaters
•   on/off control of coolers and freezers                                                                           A419ABG-3 Electronic Thermostat
•   agriculture
•   home brewing

Repair Information
If the A419 Electronic Thermostat for Temporary Installations (Drop Cord
Electrical Connection) fails to operate within its specifications, replace
the unit. Contact the nearest Johnson Controls® representative.

Selection Chart
Product Code Number                             Switch Action                                   Range °F (°C)                                  Differential F° (C°)
A419ABG-3C                                      Single-Pole, Single-Throw (SPST)                -30 to 212 (-34 to 100)                        1 to 30 (1 to 30)

Technical Specifications
Electrical Ratings
Motor Ratings VAC                                                                                                   120
AC Full Load Amperes                                                                                                 12
AC Locked Rotor Amperes                                                                                              72

The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2015 Johnson Controls, Inc.                  www.johnsoncontrols.com